Hydraulic Pressure Switch Guide

This document provides specifications for electro-mechanical hydraulic pressure switches with adjustable and fixed switching pressure differences ranging from 3 to 420 bar. The switches feature microswitches with gold-plated contacts, robust metal housings, and electrical connections according to DIN EN 175 301-803. They are designed for intrinsically safe operation with hydraulic oils and other non-inflammable fluids.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views4 pages

Hydraulic Pressure Switch Guide

This document provides specifications for electro-mechanical hydraulic pressure switches with adjustable and fixed switching pressure differences ranging from 3 to 420 bar. The switches feature microswitches with gold-plated contacts, robust metal housings, and electrical connections according to DIN EN 175 301-803. They are designed for intrinsically safe operation with hydraulic oils and other non-inflammable fluids.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

20D

Electro-mechanical hydraulic pressure switches


> 3 ... 420 bar > Electrical connection:
Port size: G1/4 connector acc. to
> High accuracy DIN EN 175 301-803,
form A or M20x1,5
> Microswitch with gold (DIN 46320)
plated contacts
> Intrinsically safe
operation
> Robust metal housing

Technical features
Medium: Media viscosity: Degree of protection: Material:
Hydraulic oil, oiled compressed Up to 1000 mm2/s IP65 for DIN EN 175301-803 Housing: Aluminium diecast
air and other non-inflammable Sealing: (DIN 43650) form A connection Sensor: Brass or stainless steel
fluids with sliding properties ≤10-7 mbar x l x s-1 IP66 with cable gland Sealing: steel piston with NBR,
Operating pressure: Pulsation: Electrical connection: lip seal or o-ring
3 ... 420 bar (44 ... 6091) Not permitted DIN EN 175301-803 (DIN 43650)
Operation: Switching pressure difference: form A or cable gland
Softseal piston, stainless steel Optional: fixed or adjustable Shock-/vibrationproof:
bellow Switching element: 4 g max. (sinusoidal)/5 Hz max
Repeatability: Microswitch with gold plated Switching cycles:
±1% of final value contacts 20/min. maximum
(depending on regulating pres- Mounting position: Ambient/Media temperature:
sure) Vertical down 0 ... +80°C (0 ... +176°F)
Port size: Air supply must be dry enough to avoid ice
formation at temperatures below +2°C
G1/4 (+35°F).

Technical data - fixed switching pressure difference


Symbol Differential pressure range *2) Final value *1) Switching pressure difference (typical) Model
pvu min ... pvo max. (VDI 3283) Lower rang Upper range
(bar) (bar) (bar) (bar)
3 ... 40 300 5 9 1816200
5 ... 63 300 6 13 1816300
5 ... 100 300 6 16 1816400
5 ... 160 300 7 19 1816500
10 ... 220 300 10 25 1816600 0000 001 00
10 ... 420 550 18 42 1816700 0000 002 00

Technical data - adjustable switching pressure difference


Symbol Differential pressure range *2) Final value *1) Switching pressure difference (typical) Model
pvu min ... pvo max. (VDI 3283) Lower range Upper range
minimum maximum
(bar) (bar) (bar) (bar) (bar)
3 ... 40 300 8 13 25 1806200
5 ... 63 300 10 16 40 1806300
5 ... 100 300 11 16 80 1806400
5 ... 160 300 13 22 120 1806500
10 ... 220 300 14 28 120 1806600 0000 001 00
10 ... 420 550 20 40 330 1806700 0000 002 00
*1) In case of vibrations, please install a surgr damper; even short-term pressure peakes are not allowed to exceed this limit value during operation. Operative
utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure.
*2) Reference pressure is the atmospheric air pressure

Our policy is one of continued research and development. We therefore reserve the right to amend, 6/15
without notice, the specifications given in this document. (1996 - 5291c) © 2015 Norgren GmbH en 5.11.120.01
Option selector 18˙˙˙˙˙

Switching pressure Substitute Electrical connection Substitute


difference Interface for DIN EN 00
Adjustable 0 175301-803 form A
connector *1)
Fixed 1
Pressure range (bar) Substitute Cable gland 05
*1) Connector is not in scope of delivery
3 ... 40 62
5 ... 63 63
5 ... 100 64
5 ... 160 65
10 ... 220 66
10 ... 420 67

Accessories Accessories
Surge damper Pressure port – Brackets Connector Connector with LED
reducing nipple DIN EN 175301-803

Page 4 Page 4 Page 4 Page 4


0553258 (stainless steel G1/4) 0550083 (G1/4 » G1/2) 0574772 (steel) 0570110 (Form A) 0585418
0574773 (brass/steel G1/4) 0574765 (G1/4 » 1/4 NPT) 0553908 (stainless steel)

Switching function
Connector
DIN EN 175301-803,
form A
2 3 Microswitch SPDT
p Terminals 1 - 3:
Contacts close
1 on rising pressure.
Terminals 1 - 2:
Contacts open
on rising pressure.

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 5.11.120.02 without notice, the specifications given in this document. (1996 - 5291c) © 2015 Norgren GmbH 6/15
Switching capacity
Commutator with gold plated contacts
Load level Current Load type *2) Max. permissible persistent current Imax [A] at U *1) Electrical life-time
type M20 x 1,5
30 V 250 V
Standard *3) a.c. Ohmic 7 5
(contractors, solenoids) a.c. Inductive, cos φ ≈ 0,7 3 0,03
≥ 2 x 105 Switching cycles
d.c. Ohmic 7 0,4
d.c. Inductive, L/R ≈ 10 ms 3 0,03
Reference number: 20/min, Reference temperature: +20°C. *1) Higher currents (5 A max) will cause a reduction of the durability of the micro-
Spark quenching with diode with DC and inductive load: switch contacts. Futhermore additional measures has to be taken to fulfil the
I min = 1 mA; I max = 1,5 x I max of table EMV regulation 2004/108/EG by the manufacturer
Creepage and air paths correspond to insulation group B according to *2) Spark quenching/overload protection will be necessary using inductive loads.
VDE Reg. 0110 (except contact clearance of microswitch). *3) Gold-plating not required as it would decay.
Max. perm. in-rush current (appr. 30 ms) I AC = max. 15 A

Recommended circuit + (a.c.)

Spark quenching and EMV intrinsically safe


1. Diode D in parallel to inductive load. p
Observance of correct polarity (positive pole to cathode).
Dimensioning specifications for quenching diode:
Us
Rated voltage at diode: UD ≥ 1,4 x Us RL
D R
Rated current at diode: IN ≥ ILoad IL
Selection of a quick switching diode (recovery time trr ≤ 200 ms) C

2. RC link in parallel to load in parallel to switching contact. - (a.c.)


Dimensioning principles:
RL in Ω ≈ 0,2 x RLoad in Ω RL = Load resistance
C in [μF] ≈ ILoad in [A] IL = Load current

Dimensions 43,5
Dimensions in mm
Projection/First angle
22
115,5 19 5,8 104

C
22

C
1
50,5

70
81

D D
~ 66

G1/4 19
47

1 M4 x 10 deep

Our policy is one of continued research and development. We therefore reserve the right to amend,
6/15 without notice, the specifications given in this document. (1996 - 5291c) © 2015 Norgren GmbH en 5.11.120.03
Surge damper Pressure port/reducing nipple Dimensions in mm
Projection/First angle
Model: Model: 0550083 (stainless steel Model: 0574765 (brass)
0574773 (brass) 1.4305 AISI 303/304 S)
0553258 (stainless steel
1.4301 AISI 304)
G1/4 G1/4 G1/4

12

12
30
22 22 22

43,5
46

22,5
34

1/4 NPT

6,5
ø 20
G1/2
G1/4
ø 21,5

Brackets (2 brackets and 4 screws) 141


129
Model:
0574772 (steel) 104
0553908 (stainless steel 1.4301 AISI 304)

5,8
12

3
14
118
Connectors (black) with
light indicator 3-pin +
protective conductor
Connection acc. to
DIN EN 175301-803 (form A)
Voltage: 12 ... 28 V d.c./a.c.
Model: 0585418
34

70
39

Warning
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes of
systems only. Do not use these products where pressures and all component parts used in fluid power systems and to provide
temperatures can exceed those listed under »Technical features/ adequate safeguards to prevent personal injury or damage to
data«. equipment in the event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in the
for non-industrial applications, life-support systems or other system instructional manual if protection against a failure mode
applications not within published specifications, cannot be adequately provided.
consult Norgren. System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in fluid warnings found in instruction sheets packed and shipped with
power systems can fail in various modes. these products.

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 5.11.120.04 without notice, the specifications given in this document. (1996 - 5291c) © 2015 Norgren GmbH 6/15