0% found this document useful (0 votes)
631 views8 pages

Liebert PCW Brochure English

The document summarizes the VertivTM Liebert® PCW chilled water perimeter unit. It provides cooling for data centers from 25 to 220 kW. It emphasizes cooling continuity, energy efficiency, flexibility, and smart control features. These include dual circuit redundancy, pressure independent valves, multiple coil options, and the Liebert® iCOMTM control system.

Uploaded by

ktp070
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
631 views8 pages

Liebert PCW Brochure English

The document summarizes the VertivTM Liebert® PCW chilled water perimeter unit. It provides cooling for data centers from 25 to 220 kW. It emphasizes cooling continuity, energy efficiency, flexibility, and smart control features. These include dual circuit redundancy, pressure independent valves, multiple coil options, and the Liebert® iCOMTM control system.

Uploaded by

ktp070
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Vertiv™ Liebert® PCW

Chilled Water Perimeter Unit


from 25 to 220 kW
Vertiv™ Liebert® PCW | Chilled Water Perimeter Unit

Liebert® PCW is Designed to Lead the Thermal Management Liebert® PCW Versions
Market for Chilled Water Perimeter Units for All Data Center
Configurations Configurations
•• From 25 to 220 kW
Liebert® PCW, thanks to its well-established design, minimizes running costs for the •• From 1 to 4 fans
entire cooling system. All components and control strategies are enhanced to provide •• Single or Dual Circuit
an extremely efficient solution for infrastructures facing the challenges of modern IT
•• More than 4 air delivery
applications. configurations
Liebert® PCW, due to new advanced technologies, matches requirements for cooling
continuity coming from the most trusted and approved certification authorities for Main Options:
data center design and operation. The Liebert® PCW ensures precise and constant •• Touch Screen Display
control of airflow, temperature, and humidity under all working conditions. Cooling •• Pressure Independent Control
continuity and reliability are key factors for Liebert® PCW and mission critical Valves
infrastructures. •• Dual power supply with Control
Power Continuity
Liebert® PCW adapts perfectly to each data center’s room air condition and water
temperature requirement. A wider operating range allows users to remain a step •• Electrical/Water heating
system
ahead of new challenges posed by data center requirements and climate change.
Liebert® PCW is an extremely flexible unit able to adapt to different site needs. •• Electrode, Infrared or
Ultrasonic humidifier
Liebert® PCW uses algorithms developed and perfected over fifty years of business •• Air Economizer for Direct
experience and comes now with a new 7” touch screen display for quicker and easier Freecooling
data readability. •• Damper and Extension Hood

Value of Liebert® PCW Range

Features How You Benefit


•• Latest generation of EC fans •• Powerful fans increase the
cooling capacity at the same
unit footprint.
•• Eurovent certified performance •• Delivers performance rating
accuracy, certified by an
independent organization.

•• Pressure independent control •• System energy efficiency


valve increased due to a better water
distribution.

•• Multiple enhanced coils •• Ad-hoc coils to best suit the new


data center market trends.

•• Cooling override function •• Even in case of a control failure,


the unit can guarantee cooling
continuity.

•• Virtual Display •• Through a web browser, all the


functionalities of the standard
display can be replicated.
Cooling Continuity Energy Efficiency
Liebert® PCW maximizes cooling continuity and Liebert® PCW is designed to set new efficiency
reliability, matching the requirements coming from standards on chilled-water cooling systems for data
the most trusted and adopted certification authorities centers. The unit’s internal design combines market-
for data center design and operation. leading technologies and optimize the aerodynamic
impact of all the internal components.

Flexibility Smart Liebert® iCOMTM Control


Liebert® PCW perfectly adapts to each data center’s The Liebert® iCOMTM control manages and optimizes
room air condition and water temperature the overall system. It is fully-programmable via an
requirements. This unit is extremely flexible, with advanced and user-friendly touch display and can be
regards to airflow configurations, chilled water linked with common BMS protocols, allowing remote
connections type, and electrical arrangements. supervision.
Vertiv™ Liebert® PCW | Chilled Water Perimeter Unit

Energy Efficiency
yyThe unit design minimizes the aerodynamic impact of all the internal parts; any detail like coil shape,
coil size, coil angle, electrical panel design, fan separator has been optimized, ensuring a significant
10% reduced internal air pressure drop that immediately becomes a benefit in terms of reduced unit
power consumption.
yyEurovent certified performance guarantees independent testing, thus delivering rating accuracy and
enhancing the unit’s reliability. The new IT Cooling program updates performance tolerance,
introducing stricter values than previous ones.*
yyAs a result of the latest evolution of the EC fans technology, unit energy efficiency improves; utilizing
powerful fans, unit cooling capacity increases more than 5% with the same unit footprint.
yyPressure independent control valves regulate and maintain a constant flow to the unit as water
pressure in the system varies. Delivering better water distribution and thus increasing overall system
energy efficiency.

Cooling Continuity
yyDual circuit units integrate in the same frame two independent chilled water circuits, which can be
connected to two different water loops. In case the first circuit fails, the second one can substitute
and provide the necessary cooling back up.
yyThe cooling override function is the best answer to increase the unit reliability, in case of control failure
and during the re-booting time, limiting cooling interruptions to the IT equipment.
yyThe airflow continuity is guaranteed until the last unit fan is able to run.
yyIn case of control sensor failure, the unit automatically adapts in order to grant the necessary cooling/
airflow continuity. A redundant sensor can be installed and activated only if the first one breaks or is
missing.

Flexibility
yyMultiple enhanced coils permit to best suit the different market trends, in terms of room air conditions
and water temperature requirements, adapting perfectly to each data center’s working condition.
yyMore than 4 airflow configurations, chilled water connections provided in three different positions with
different terminals allow the units to adapt to any data center layout and configuration.
yyElectrically, units can be fed with two power sources combined with an ATS for full back-up or with
two separate lines, one for the main devices and the other for the auxiliaries. Control power continuity
can keep the CPU and BMS on for at least 1 minute during a power outage.
yyThe maximum return air working temperature is up to 45°C, this permits the infrastructures facing the
challenges of modern IT applications to develop an extremely efficient environment.

Smart Control
yyReady for Teamwork of up to 32 units with optimization based on installation type, furthermore it
allows for advanced control functionality (sharing sensor’s data, standby rotation, lead-lag, cascade
operation and rotating master function).
yyThe Liebert® iCOMTM software embeds a comprehensive algorithm library with more than 10 different
strategies to control temperature/humidity & airflow developed for adapting perfectly to the different
data center solutions.
yyA virtual display can replicate, through a web browser, all the functionalities of the standard display,
either remotely or connecting a laptop on the ethernet port directly to the frontal door.
yyUnit power consumptions and cooling gross capacity can be calculated thanks to specific algorithms
and the direct communication between the control, sensors and the EC fans motor. This allows the
monitoring of the unit energy efficiency through the BMS system.

* Check ongoing Eurovent certification validity: www.eurovent-certification.com


Rely on a Higher Level of Service Expertise for Thermal Management in Your Data Center
Supporting Your Business Around
Who is better prepared to meet the service needs for your
the Globe
thermal management system than the company that
We bring our combination of strengths
pioneered the precision air conditioning market? We’re a to life on a global scale, ensuring that
world leader in research and development of innovative we’re able to serve you wherever you do
business. Vertiv has the largest factory-
products that protect mission-critical thermal applications trained service force with more than
and have supported data centers around the world for 2,700 field engineers together with the
capability to support you remotely with a
decades. comprehensive range of remote Services
and Software Solutions. Our service
team members are located in virtually
After all, there’s a vast difference in the expertise necessary to address the comfort
every major country across the globe
cooling needs of a normal building and the thermal management needs of your
and are backed by more than 330
sensitive and sophisticated data center. An incorrect repair procedure by improperly
technical support/response personnel.
trained technicians, or the use of non-genuine parts, can have a profound effect on
This means that no matter where you
your equipment performance, your data center availability, and your energy costs.
operate, you are covered by the most
The factory trained and certified technicians of Vertiv know the difference. We are knowledgeable engineers and
equipped to maximize the performance and efficiency of your thermal management technicians available, giving you relief
system as no one else can. from any concern.

Our Presence

Global Presence
Manuf. and Assembly Locations 28
Service Centers 250+
Service Field Engineers 2,650+
Technical Support/Response 300+
Customer Experience Centers/Labs 16

US and Canada Latin America Europe, Middle East And Africa Asia Pacific
Manuf. and Assembly Locations 13 Manuf. and Assembly Locations 1 Manuf. and Assembly Locations 9 Manuf. and Assembly Locations 5
Service Centers 100+ Service Centers 20+ Service Centers 70+ Service Centers 60+
Service Field Engineers 850+ Service Field Engineers 240+ Service Field Engineers 590+ Service Field Engineers 970+
Technical Support/Response 120+ Technical Support/Response 20+ Technical Support/Response 90+ Technical Support/Response 80+
Customer Experience Centers/Labs 4 Customer Experience Centers/Labs 2 Customer Experience Centers/Labs 5 Customer Experience Centers/Labs 5
Vertiv™ Liebert® PCW | Chilled Water Perimeter Unit

Liebert® PCW - Standard Height PW025 PW030 PW035 PW040 PW045 PW060 PW070 PW080 PW095 PW110 PW145 PW170

Net Sensible Cooling Capacity kW 29 34.3 38.1 44 47.9 68.5 74.6 87.2 105.4 120.6 144 170.9
Legacy Coil

Single Circuit Net Sensible Cooling Capacity kW - 35.7 - 45.8 - 77.2 - 91.6 - 126 143 170.4
Cooling Capacity Smart Coil

Net Sensible Cooling Capacity kW 28.4 - 39.2 - 51.5 68 76.1 - 104.6 - - -


Eco Coil

Dual Circuit Net Sensible Cooling Capacity kW* - - - 35.3 - 52.7 - 63.7 - 87.2 99.7 119.3
Cooling Capacity Legacy Coil

Power input kW 1.39 1.83 1.45 1.69 1.56 2.85 2.67 3.63 4.2 5.37 6 7.39

2600 2900 3400 3400 5300 5400 6700 7200 9000 10300 12000 13000
Airflow Range [%] m3/h
12000 12000 16000 16000 18000 27000 30400 30000 41000 42000 50000 55000

Spare Capacity % 25 15 20 20 20 20 25 15 20 20 15 20

Length mm 844 844 1200 1200 1750 1750 2050 2050 2550 2550 2950 3350

Dimension Width mm 890 890 890 890 890 890 890 890 890 890 890 890

Height mm 1970 1970 1970 1970 1970 1970 1970 1970 1970 1970 1970 1970

Down Flow UP
Fans Over the Raised Floor • • • • • • • • • • • •

Up Flow • • • • • • • • • •
Unit
Configuration
Frontal • • • • • • • • • •
Downflow Down
Fans in Raised Floor • • • • • • • • • •

Operating Modes
Legacy - RAT 26°C 40% RH; Water I/O 10°C - 15°C; ESP 20Pa; Downflow Up; EC Fan Advance - HE
Smart - RAT 35°C 30% RH; Water I/O 18°C - 26°C; ESP 20Pa; Downflow Up; EC Fan Advance - HE
Eco - RAT 30°C 30% RH; Water I/O 8°C - 15°C; ESP 20Pa; Downflow Up; EC Fan Advance - HE
* with one circuit running
Liebert® PCW - Extended Height PW046 PW066 PW091 PW136 PW161 PW201

Net Sensible Cooling Capacity kW 49.4 75.9 95.9 134.9 164.3 206
Single Circuit Legacy Coil
Cooling Capacity Net Sensible Cooling Capacity
Smart Coil kW 53.9 61.7 73.1 103.2 119.2 147.3

Dual Circuit Net Sensible Cooling Capacity kW* 39.9 61.7 73.1 103.2 119.2 147.3
Cooling Capacity Legacy Coil

Power input kW 2.22 2.41 3.15 4.95 6.48 9.23

Airflow Range [%] m3/h 4600 - 18000 7600 - 31000 8300 - 33000 12000 - 47000 13000 - 50000 14600 - 61000

Spare Capacity % 10 30 20 20 10 10

Length mm 1200 1750 2050 2550 2950 3350

Dimension Width mm 890 890 890 890 890 890

Height: Coil + Fan mm 1970 + 600 1971 + 600 1972 + 600 1973 + 600 1974 + 600 1975 + 600

Down Flow UP
Fans Over the Raised Floor • • • • • •
Down Flow UP
Frontal air Delivery • • • • • •
Down Flow UP
Back air Delivery • • • • • •
Unit
Configuration
Up Flow • • •
Downflow Down
Fans in Raised Floor • • • • • •
Downflow Down
Back air Delivery • • • • • •

Operating Modes
Legacy - RAT 26°C 40% RH; Water I/O 10°C - 15°C; ESP 20Pa; Downflow Up; EC Fan Advance - HE
Smart - RAT 35°C 30% RH; Water I/O 18°C - 26°C; ESP 20Pa; Downflow Up; EC Fan Advance - HE
* with one circuit running

Liebert® PCW - Hight Chilled Water DT PW51W PW50W PW60W PW70W

Single Circuit Net Sensible Cooling Capacity kW 111,4 135,7 152,3 173,7
Cooling Capacity High Technology Coil
Dual Circuit Circuit Net Sensible Cooling Capacity kW* - 99.5 112.7 128.3
Cooling Capacity High Technology Coil

Power input kW 4,78 4,99 5,47 6,7

Airflow Range [%] m3/h 15000 - 47500 15000 - 47500 15000 - 50000 15000 - 60200

Spare Capacity % 25 15 10 15

Length mm 2550 2550 2950 3200

Dimension Width mm 1050 1050 1050 1050

Height: Coil + Fan mm 2351 + 600 2350 + 600 2352 + 600 2353 + 600

Downflow Down
Fans in Raised Floor • • • •
Unit
Configuration Downflow Down
Back air Delivery • • • •

Operating Modes
High Temperature - RAT 35°C 30% RH; Water I/O 20°C - 32°C; ESP 20Pa; Downflow Down - Open Door; EC Fan Advance - HE
* with one circuit running
Vertiv.com | Vertiv Infrastructure Limited, George Curl Way, Southampton, SO18 2RY, VAT Number: GB188146827
© 2020 Vertiv Group Corp. All rights reserved. Vertiv™ and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While
every precaution has been taken to ensure accuracy and completeness here, Vertiv Group Corp. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications, rebates and other
promotional offers are subject to change at Vertiv’s sole discretion upon notice.

MKA4L0UKPCWPW – Rev.1 – 10/2020

You might also like