The document provides order codes and accessories for Universal Relays P3U10, P3U20 and P3U30. It lists the order code structures for the different relay models, which include fields to specify the application, current and voltage inputs, supply voltage, digital inputs, communication options and region. It notes that the power supply range should be checked from the device label and that all circuit boards are conformally coated.

Uploaded by

Loo Kl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
629 views3 pages

P3U Order Form

The document provides order codes and accessories for Universal Relays P3U10, P3U20 and P3U30. It lists the order code structures for the different relay models, which include fields to specify the application, current and voltage inputs, supply voltage, digital inputs, communication options and region. It notes that the power supply range should be checked from the device label and that all circuit boards are conformally coated.

Uploaded by

Loo Kl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Universal Relays P3U10, P3U20 and P3U30 12 Order codes and accessories

12 Order codes and accessories

12.1 Order codes


When ordering, state:
• Order code of the relay
• Quantity
• Accessories (see the order codes in section Accessories)

Figure 230 - P3U10 order code

X1 X1 X2 X5 X4

Easergy P3U10 - A A A A Protection relay

Application
U10 = Feeder & Motor, 4xI, 1xU. 2DI, 5DO

Phase currents & voltage input, X1


5 = 1A/5A & 1V (100/110V), pluggable clamp connector
6 = 1A/5A & 1V (100/110V), pluggable ring lug connector

Ground fault current input,X1


A = 1A/5A
B = 0.2A/1A

Nominal Supply Voltage [V], X2


A = Power A 48-230 V (range: 38.4... 253 Vac/dc)
B = Power B 24-48 V (range: 19.2... 57.6 Vdc) (1

Future option
A = None

DI treshhold voltage (V)


1 = 24 Vdc/ac
2 = 110 Vdc/ac
3 = 220 Vdc/ac

Voltage measurements + I/O, X5


A = None

I/O with comms, X4


A = None

Product version
A = Version 2.1, newest FW

Region
A = English, IEC
B = English, ANSI X1=6

1) Always check the power supply range from the device's serial number label.

NOTE: All PCBA cards are conformally coated.

410 P3U/en M/J006


12 Order codes and accessories Universal Relays P3U10, P3U20 and P3U30

Figure 231 - P3U20 order code


X1 X1 X2 X5 X4

Easergy P3U20 - A A A Protection relay

Application
U20 = Feeder & Motor, 4xI, 1xU. 2DI, 5DO

Phase currents & voltage input, X1


5 = 1A/5A (pluggable clamp) & 1U (100/110V)
6 = 1A/5A (pluggable ringlug) & 1U (100/110V)

Earth-fault current input, X1


A = 1A/5A
B = 0.2A/1A

Nominal Supply Voltage [V], X2


A = Power A 48 - 230 V
B = Power B 24 - 48V (1

Future option
A = None

Nominal DI voltage (voltage withstand)


1 = 24Vdc/ac (255 Vdc/ac)
2 = 110 Vdc/ac (255 Vdc/ac)
3 = 220 Vdc/ac (255 Vdc/ac)
4 = DI1-2: 24 Vdc/ac, DI3-10: 110 Vdc/ac (255 Vdc/ac)
5 = DI1-2: 24 Vdc/ac, DI3-10: 220 V dc/ac (255 Vdc/ac)

Voltage measurements + I/O, X5


A = None

I/O with comms, X4


B = RS-485 + 8DI
C = 2 x RJ-45 + 8DI
D = 2 x LC + 8DI
E = RJ + 232 + 8DI with IRIG-B
F = LC + 232 + 8DI with IRIG-B
G = RS485 + 6DI + 3DO
H = 2 x RJ45 + 6DI + 3DO
I = 2 x LC + 6DI + 3DO

Product version
A = Version 2.1, newest FW
B = FW30.108

Region
A = English, IEC
B = English, ANSI X1=6

1) Always check the power supply range from the device's serial number label.

NOTE: All PCBA cards are conformally coated.

P3U/en M/J006 411


Universal Relays P3U10, P3U20 and P3U30 12 Order codes and accessories

Figure 232 - P3U30 order code


X1 X1 X2 X5 X4

Easergy P3U30 - A A Protection relay

Application
U30 = Feeder & Motor, 4xI, 4xU. 2DI, 5DO

Phase currents & voltage input, X1


5 = 1A/5A & 1V (100/110V), pluggable clamp connector X5 = B
6 = 1A/5A & 1V (100/110V), pluggable ring lug connector X5 = B

Ground fault current input,X1


A = 1A/5A
B = 0.2A/1A

Nominal Supply Voltage [V], X2


A = Power A 48-230 V (range: 38.4... 253 Vac/dc)
B = Power B 24-48 V (range: 19.2... 57.6 Vdc) (1

Future option
A = None

DI treshhold voltage (V)


1 = 24 Vdc/ac
2 = 110 Vdc/ac
3 = 220 Vdc/ac
4 = 24 Vdc/ac for DI -DI2, 110 Vdc/ac for DI3-DI16 (255 Vdc/ac)
5 = 24 Vdc/ac for DI1-DI2, 220 Vdc/ac for DI3-DI16 (255 Vdc/ac)

Voltage measurements + I/O, X5


B = 3V (100/110V) + 6DI + 3DO X1 = 5 or 6

I/O with comms, X4


B = RS-485 + 8DI
C = 2 x RJ-45 + 8DI
D = 2 x LC + 8DI
E = RJ + 232 + 8DI with IRIG-B
F = LC + 232 + 8DI with IRIG-B
G = RS-485 + 6DI + 3DO X1 = 5 or 6
H = 2 x RJ-45 + 6DI + 3DO X1 = 5 or 6
I = 2 x LC + 6DI + 3DO X1 = 5 or 6

Product version
A = Version 2.1, newest FW
B = FW30.108
Region
A = English, IEC
B = English, ANSI X1 = 6

1) Always check the power supply range from the device's serial number label.

NOTE: All PCBA cards are conformally coated.

12.2 Accessories
Table 148 - Accessories for Easergy P3 Standard

Product reference Description REL code P3U10 P3U20 P3U30

VIO12AASE RTD module, 12pcs RTD inputs, Optical Tx REL52811 X X

VIO12ABSE RTD module, 12pcs RTD inputs, RS485 REL52812 X X

VIO12ACSE RTD module, 12pcs RTD inputs, mA in/out REL52813 X X

VIO12ADSE RTD module, 12pcs RTD inputs, mA in/out REL52814 Y X

VPA3CGSE Profibus interface module REL52815 X X

Bluefer Nomad wireless adapter REL52850 X X X

VSE001-GGSE Fiber optic module (Glass - Glass) REL52816 X X

VSE001-GPSE Fiber optic module (Glass - Plastic) REL52817 X X

412 P3U/en M/J006