0% found this document useful (0 votes)
141 views1 page

Mitsubishi FX3G-485-BD Manual

The document provides installation and specification details for the FX3G-485-BD RS-485 communication expansion board. It includes precautions for use, a list of included items, communication functions supported, and specifications for baud rate, communication method, and insulation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
141 views1 page

Mitsubishi FX3G-485-BD Manual

The document provides installation and specification details for the FX3G-485-BD RS-485 communication expansion board. It includes precautions for use, a list of included items, communication functions supported, and specifications for baud rate, communication method, and insulation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

JY997D32201J Side

B
Side
A JAPANESE
Side
B ENGLISH Attention
INSTALLATION Item Specification
This product is designed for use in industrial applications. PRECAUTIONS
1. Outline Communication
Half-duplex
• Use the product within the generic environment specifications described in PLC method
FX3G-485-BD is an expansion board equipped with an European terminal block for RS- main unit manual (Hardware Edition).
485 communication. The FX 3G-485-BD exchanges data with RS-485 devices. For Non-Protocol Communication, Computer Link (dedicated
FX3G-485-BD wiring, specifications, settings, and program examples, refer to the following manual.
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl 2, H 2S, SO2, or NO2), flammable gas, vibration
Communication
format
protocol format 1 and 4), Parallel Link, N:N network, and
→ FX Series User's Manual - Data Communication Edition or impacts, or expose it to high temperature, condensation, or rain and wind. Inverter communication*1
INSTALLATION MANUAL 1.1 Incorporated Items If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur. Non-Protocol Communication, Computer Link
Product RS-485 communication expansion board FX3G-485-BD : 300/600/1200/2400/4800/9600/19200
• Use screwdrivers carefully when performing installation work, thus avoiding
/38400 bps
• M3×8 tapping screws for installation: 2 pcs. accident or product damage.
Manual Number JY997D32201 Baud rate Parallel Link : 115200 bps
Included • Station number labels for linking • When drilling screw holes or wiring, make sure cutting or wire debris does not N:N network : 38400 bps
Revision J items • Side cover enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions. Inverter communication*1
Date June 2018 • Installation Manual (This manual)
: 4800/9600/19200/38400 bps
• Do not touch the conductive parts of the product directly.
1.2 Communication Function Doing so may cause device failures or malfunctions. Insulation Not insulated (Between communication line and CPU)
• Connect expansion board securely to their designated connectors.
This manual describes the part names, dimensions, mounting, and specifications Communication type Function Loose connections may cause malfunctions. *1 The FX3G Series PLC Ver. 1.10 or later in applicable.
of the product. Before use, read this manual and the manuals of all relevant
N:N network Data transfer connecting up to eight FX Series PLCs.
products fully to acquire proficiency in handling and operating the product. Make For the installation, refer to the following manual.
sure to learn all the product information, safety information, and precautions.
Parallel link
Data transfer between two PLCs relationship specifying → FX3S Series User's Manual - Hardware Edition 「电器电子产品有害物质限制使用标识要求」的表示方式
Store this manual in a safe place so that it can be taken out and read whenever master/slave station. → FX3G Series User's Manual - Hardware Edition
necessary. Always forward it to the end user. 3. Specifications
Registration: Data transfer between PLC and computer (specified as the
Computer link STARTUP AND
master station) via dedicated protocol. Note: This symbol mark is for China only.
The company and product names described in this manual are registered MAINTENANCE
trademarks or the trademarks of their respective companies. Non-protocol Serial communication between PLC and RS-485 device via PRECAUTIONS
Effective June 2018 communication non-protocol. 含有有害6物质的名称,含有量,含有部品
• Do not disassemble or modify the PLC.
Specifications are subject to change without notice. Doing so may cause fire, equipment failures, or malfunctions.
本产品中所含有的有害6物质的名称,含有量,含有部品如下表所示。
Inverter Controlling Mitsubishi's FREQROL inverter using Inverter
© 2008 Mitsubishi Electric Corporation communication*1 communication instructions. * For repair, contact your local Mitsubishi Electric representative.
• Do not drop the product or exert strong impact to it.
Safety Precaution (Read these precautions before use.) *1 The FX3G Series PLC Ver. 1.10 or later in applicable. Doing so may cause damage. 产品中有害物质的名称及含量
1.3 External Dimensions and Part Names
This manual classifies the safety precautions into two categories:
DISPOSAL
有害物质
Unit: mm (inches)
and . PRECAUTIONS
[5] 部件名称 多溴
铅 汞 镉 六价铬 多溴联苯
• Please contact a certified electronic waste disposal company for the 二苯醚
Indicates that incorrect handling may cause hazardous [7] Connector cover is environmentally safe recycling and disposal of your device. (Pb) (Hg) (Cd) (Cr(VI)) (PBB)
(PBDE)
51.2 (2.02")

conditions, resulting in death or severe injury. [4] removed

Indicates that incorrect handling may cause hazardous TRANSPORTATION AND 可编程 外壳 ○ ○ ○ ○ ○ ○
[9] STORAGE PRECAUTIONS
conditions, resulting in medium or slight personal injury 控制器 印刷基板 × ○ ○ ○ ○ ○
or physical damage. [3] • The product is a precision instrument. During transportation, avoid impacts
[2]
[6] larger than those specified in the general specifications by using dedicated 本表格依据SJ/T 11364的规定编制。
MASS (Weight): 20 g (0.05 lbs) packaging boxes and shock-absorbing palettes. Failure to do so may cause
Depending on the circumstances, procedures indicated by may
35 (1.38") 15.1 14.1 failures in the product. After transportation, verify operation of the product and ○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572
also cause severe injury. [1] check for damage of the mounting part, etc.
It is important to follow all precautions for personal safety. (0.6") (0.56") 规定的限量要求以下。
Setting terminal Setting no Setting terminal ×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T
Associated Manuals [8] 3.1 Applicable PLC
resistor to 110Ω terminal resistor resistor to 330Ω 26572规定的限量要求。
Manual name Manual No. Description Model name Applicability
110Ω 330Ω 110Ω 330Ω 110Ω 330Ω 基于中国标准法的参考规格:GB/T15969.2
FX3S Series JY997D48601 Explains the FX 3S Series PLC OPEN OPEN OPEN FX 3S Series PLC Ver. 1.00 or later (from first production)
User’s Manual MODEL CODE: specifications for I/O, wiring, Carefully operate the switch not to
damage the circuit board or electronic parts. FX 3G Series PLC Ver. 1.00 or later (from first production)
- Hardware Edition 09R535 installation, and maintenance. This manual confers no industrial property rights or any rights of any other kind,
Before changing over the switch, remove • The number of connectable expansion boards varies depending on the main unit nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
FX3G Series JY997D31301 Explains the FX 3G Series PLC the upper side of the removable terminal.
User’s Manual MODEL CODE: specifications for I/O, wiring, Terminal Layout as follows: held responsible for any problems involving industrial property rights which may
For details, refer to the following manual. FX3S, FX3G-14M , FX3G-24M Main units : 1 unit occur as a result of using the contents noted in this manual.
- Hardware Edition 09R521 installation, and maintenance.
→ FX Series User's Manual-Data Communication Edition FX3G-40M , FX3G-60M Main units : 2 units
RDB
RDA
SDB
SDA
SG

FX3S /FX3G/FX3GC/FX 3U/ Never stack up two or more expansion boards. Warranty
FX3UC Series JY997D16601 Describes PLC programming for For details on the system configuration, refer to the following manual. Exclusion of loss in opportunity and secondary loss from warranty liability
Programming Manual - MODEL CODE: basic/applied instructions and Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
Basic & Applied Instruction 09R517 devices. → FX Series User's Manual - Data Communication Edition
5 poles (1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
Edition 3.2 General Specifications (2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
Explains N:N network, Parallel [1]Terminal resistor changing-over switch Recommended screwdriver to The general specifications are equivalent to the PLC main unit. For general (3) Special damages and secondary damages whether foreseeable or not, compensation for
FX Series User’s Manual - JY997D16901 specifications, refer to the following manuals. accidents, and compensation for damages to products other than Mitsubishi products.
Link, Computer Link, Non- (110Ω/OPEN/330Ω) tighten terminal screws
Data Communication MODEL CODE: However, since the product is not isolated between communication lines and the
Protocol communication by RS [2]Terminal block mounting screws (4) Replacement by the user, maintenance of on-site equipment, start-up test run
Edition 09R715 The end
and RS2 instructions/FX2N-232IF. [3]SD LED: Lighting while sending data CPU of main unit, please do not perform any dielectric withstand voltage tests or and other tasks.
should be insulation resistance tests to this product.
[4]Mounting holes (2-φ3.2) straight
This manual describes the specifications and installation details for the FX3G- [5]Connector cover → FX3S Series User's Manual - Hardware Edition For safe use
485-BD. [6]RD LED: Lighting while receiving data → FX3G Series User's Manual - Hardware Edition
F or w i r i n g w i t h c om mu n i c a ti o n eq ui pm en t , s y s te m c on fi gu r a ti o n , [7]Main unit connector
0.4 mm 2.5 mm 3.3 Communication specifications • This product has been manufactured as a general-purpose part for general
communication settings, and program examples, refer to the "FX Series User's [8]Terminal block to connect RS-485 device
Manual - Data Communication Edition". industries, and has not been designed or manufactured to be incorporated in
(European terminal block) (0.01") (0.09")
Item Specification a device or system used in purposes related to human life.
[9]Memory cassette/Display module connector
How to obtain manuals • Before using the product for special purposes such as nuclear power, electric
For product manuals or documents, consult with the Mitsubishi Electric dealer 2. Installation Transmission power, aerospace, medicine or passenger movement vehicles, consult with
In conformance to RS-485/RS-422
standard
from who you purchased your product. Mitsubishi Electric.
INSTALLATION • This product has been manufactured under strict quality control. However
Maximum
Applicable standards PRECAUTIONS
transmission distance
50 m (164 ft) maximum when installing the product where major accidents or losses could occur if the
FX 3G-485-BD units made in Novem ber, 2008 or later comply with the EC • Make sure to cut off all phases of the power supply externally before attempting product fails, install appropriate backup or failsafe functions in the system.
Directive (EMC Directive). Further information can be found in the following Connection method European terminal block
installation or wiring work.
manual. Failure to do so may cause electric shock or damage to the product. Indication (LED) RD, SD
→ FX3S Series Hardware Manual (Manual No. JY997D48301)
→ FX3G Series Hardware Manual (Manual No. JY997D46001) HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

You might also like