Technical Data Sheet
TD_812
pneum. Multi-Spring-Actuator
General Data
Series 812
Diaphragm effective area MFI: 320 cm² / MFIII: 720 cm²
Stroke 20 - 60 mm
Control signal 6 bar max.
Actuator housing: 1.0332 powder coated (option: stainless steel 1.4301)
Diaphragm plate: MFI-1.0332 galvanized, MFIII-1.0037 galvanized
Yoke: 1.6220 (option: stainless steel 1.4308)
Materials Stem: 1.4122 (option: Duplex 1.4462)
Springs: 1.1230 plastic-covered
Diaphragm: NBR fabric-reinforced (moulded)
Sealing element: high-quality, special polyurethane
Spring chamber Optionally with instrument air purge
Operating temperature -20°C to +80°C (Option -40°C to + 80°C)
No. of springs MFI: 3-7 / MFIII: 3-12
Air connections Connection Z1: G⅛; Connection Z2: MFI: G⅛ / MFIII: G¼
Control force spring max. 4,8 – 22 kN
Control force air max. 14,4 – 35,2 kN
Functional description
The ARCAPAQ is a pneumatic multi-spring diaphragm actuator
with spring return (fail safe) and is used to actuate linear valves. splash-proof
The actuator positions the valve plug in dependence of the signal protective cap
pressure acting upon the actuator diaphragm, which in turn is con-
trolled by a pneumatic or electro-pneumatic positioner. These ac- Actuator housing
tuators can be operated in the "air to open" function or with the re-
verse action "air to close". Spring
The actuator has a compact design with a low installed height.
Various spring sets with different bench ranges ensure good Diaphragm
adaptation to the particular operating conditions.
A fabric-reinforced rolling-diaphragm ensures smooth conver- Diaphragm plate
sion of the pneumatic signal pressure into the linear motion of
the actuator stem. The diaphragm (4), supported by the dia- Slide bearing
phragm plate (5), is connected to the actuator stem (8) and
separates the actuator housing (2) into pressure and spring Special sealing
chamber. If the force of the pneumatic signal pressure ex- element
ceeds the opposing spring force (3), the actuator stem (8)
Actuator stem
moves and actuates the reciprocating valve.
The signal pressure is routed to the diaphragm chamber via Stroke indicator
internal channels in the yoke (10). The air vent of the spring
chamber is done by means of the protective cap (1), which is Yoke
impermeable to splash water. Optionally the spring chamber
can be purged with instrument air from the positioner either
through internal channels or by outside tubing.
The yoke (10) connects the actuator to the control valve. The
actuator stem (8) is connected to the valve stem via the cou-
pling (9), which also acts as a stroke indicator, and is securely
guided in the slide bearing (6) and sealed with a special seal-
ing element (7) with wiper ring.
© ARCA Regler GmbH Kempener Straße 18 D-47918 Tönisvorst
Tel.: +49-(0)2156-7709-0 Fax: +49-(0)2156-7709-55
[email protected] www.arca-valve.com
TD_812_en_05-2023 - Subject to technical modifications - Page 1 of 5
Technical Data Sheet
TD_812
pneum. Multi-Spring-Actuator
Control forces and control ranges
Opening function (air to open - spring to close)
Diaphragm Control range Control Force
No. of Stroke
Size surface Type force diagram
springs (mm) from (bar) to (bar
(cm²) (kN) (page 4)
812-213.. 3 0,75 1,5 2,4
MFI-20 IA
812-223.. 6 1,5 3,0 4,8
3 20 1,0 1,5 3,2
MFI-20(v) 320 812-224.. 6 2,0 3,0 6,4 IB
7 2,3 3,5 7,4
3 0,75 1,5 2,4
MFI-30 812-234.. II
6 1,5 3,0 4,8
3 0,7 1,5 5
6 1,5 3,0 10
MFIII-30 812-334.. IIIA
9 1,8 3,7 13
30
12 2,2 4,4 16
3 1,1 1,5 7,5
6 2,2 3,0 15
MFIII-30(v) 720 812-336.. IIIB
9 2,7 3,6 19
12 3,2 4,3 22
3 0,7 1,5 5
6 1,4 3,0 10
MFIII-60 812-346.. 60 IV
9 1,7 3,6 12
12 2,0 4,3 14
Closing function (air to close - spring to open)
Control Control force (kN)
Diaphragm
No. of Stroke pressure depending on control pressure
Size surface Type
springs (mm) min. 2,0 3,0 4,0 5,0 6,0
(cm²)
bar bar bar bar bar bar
812-213.. 3 1,5 1,6 4,8 8,0 11,2 14,4
MFI-20
812-223.. 6 3,0 - - 3,2 6,4 9,6
3 20 1,5 - 4,8 8,0 11,2 14,4
MFI-20(v) 320 812-224.. 6 3,0 - - 3,2 6,4 9,6
7 3,5 - - 1,6 4,8 8,0
3 1,5 1,6 4,8 8,0 11,2 14,4
MFI-30 812-234..
6 3,0 - - 3,2 6,4 9,6
3 1,5 3,6 10,8 18 25,2 32,4
6 3,0 - - 7,2 14,4 21,6
MFIII-30 812-334..
9 3,7 - - 2,2 9,4 16,6
30
12 4,4 - - - 4,3 11,5
3 1,1 6,4 13,6 20,8 28 35,2
6 2,2 - 5,7 12,9 20,1 27,3
MFIII-30(v) 720 812-336..
9 2,6 - 2,8 10 17,2 24,4
12 3,1 - - 6,4 13,6 20,8
3 1,5 3,6 10,8 18 25,2 32,4
6 3,0 - - 7,2 14,4 21,6
MFIII-60 812-346.. 60
9 3,6 - - 2,9 10,1 17,3
12 4,3 - - - 5,0 12,2
Caution: The actuator forces and spring ranges listed above are for actuator without valve at nominal stroke only
© ARCA Regler GmbH Kempener Straße 18 D-47918 Tönisvorst
Tel.: +49-(0)2156-7709-0 Fax: +49-(0)2156-7709-55
[email protected] www.arca-valve.com
TD_812_en_05-2023 - Subject to technical modifications - Page 2 of 5
Technical Data Sheet
TD_812
pneum. Multi-Spring-Actuator
Dimensions and weights
M2=Thread of
particular valve
stem
Diaphragm
No. of Stroke ØD M1 Ød S A B H HV ØR
Size surface Type Weight
springs (mm) (mm) actuator (mm) (mm) (mm) (mm) (mm) (mm) (mm)
(cm²)
3
812-213.. 40
6
MFI-20 14 20 361 508
3
812-223..
6 20 120 180
220
320 3 270 M14 48
MFI-20(v) 812-224.. 15 6 20 381 528
7
3
MFI-30 812-234.. 16 203 404 551
6
3
40
6
MFIII-30 812-334.. 489 651
9
42 30 56 25 142
12
251
3
42
6
MFIII-30(v) 720 812-336.. 400 M20x1,5 551 814 335
9
44
12
3
45
6
MFIII-60 812-346.. 60 72 30 192 309 625 888
9
47
12
© ARCA Regler GmbH Kempener Straße 18 D-47918 Tönisvorst
Tel.: +49-(0)2156-7709-0 Fax: +49-(0)2156-7709-55
[email protected] www.arca-valve.com
TD_812_en_05-2023 - Subject to technical modifications - Page 3 of 5
Technical Data Sheet
TD_812
pneum. Multi-Spring-Actuator
Force diagrams
IA MFI-20 IB MFI-20(v)
5 5
15 15
Air pressure (bar)
Air pressure (bar)
Thrust force (kN)
Thrust force (kN)
4 4
12 12
gs
7 Sprin
9 3 3
gs 9
6 Spr in s
6 S pring
6 2 6 2
3 S prings 3 Springs
3 1 3 1
0 0 0 0
0 5 10 15 20 0 5 10 15 20
Stroke (mm) Stroke (mm)
IIIA MFIII-30
II MFI-30 40
5 5
Air pressure (bar)
Thrust force (kN)
15
30
Air pressure (bar)
Thrust force (kN)
s
4 p rin g 4
12 12 S
in gs
9 Spr
3 3
9 gs 20
6 Spr in gs
6 Spr in
6 2 2
3 S prings 10
3 1 3 Springs 1
0 0 0 0
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Stroke (mm) Stroke (mm)
IIIB MFIII-30(v) IV MFIII-60
40 40
5 5
Air pressure (bar)
Air pressure (bar)
Thrust force (kN)
Thrust force (kN)
30 gs 30
12 S prin s
4 pr ing 4
9 Sprin s
g 12 S
rin gs
3 9 Sp 3
20 20
6 Springs gs
2 6 Sprin
2
10 10
3 Springs 1 3 Springs 1
0 0 0 0
0 5 10 15 20 25 30 0 10 20 30 40 50 60
Stroke (mm) Stroke (mm)
Caution: The actuator forces and spring ranges listed above are for actuator without valve at nominal stroke only
© ARCA Regler GmbH Kempener Straße 18 D-47918 Tönisvorst
Tel.: +49-(0)2156-7709-0 Fax: +49-(0)2156-7709-55
[email protected] www.arca-valve.com
TD_812_en_05-2023 - Subject to technical modifications - Page 4 of 5
Technical Data Sheet
TD_812
pneum. Multi-Spring-Actuator
Type code 812 -2 2 3 3 N- O B 0 -HV
Series
Actuator size
2 MFI diaphragm surface 320 cm²
3 MFIII diaphragm surface 720 cm²
Yoke (ø = adapter in mm)
0 1 2 3 4 9
w/o ø40 ø48 ø56 ø72 special
Hub
3 4 6
20 mm 30 mm 60 mm
Spring set
3 6 7 9 0
3 springs 6 springs 7 springs 9 springs 12 springs
Material of diaphragm chamber
N = diaphragm head steel / yoke steel
A = diaphragm head steel / yoke stainless steel
V = diaphragm head stainless steel / yoke stainless steel
Function
O = springs move the stem downwards (air to open)
S = springs move the stem upwards (air to close)
Execution
B = actuator reversible, w/o spring chamber purge
E = actuator reversible, with integrated spring chamber purge
Extra equipment
0 = w/o
1 = stroke limitation in the opening direction
4 = low temperature -40° C
5 = air connection G 1/2"
6 = screws stainless steel (long)
AP = outer parts in stainless steel passivated
B = stroke limitation adjustable for both direction O/S
EXG = Explosion-proof version Gas (Zone 1 & 2)
EXD = Explosion-proof version Dust + Gas (Zone 21 & 22 + Zone 1 & 2)
FG = spring cover 180° rotated
S = on/off actuator
SD = stem 1.4462 (Duplex) (incl. 6)
V = actuator preloaded
VB = for VDI/VDE-mounting (incl. 6 + FG)
X = peripheral bolting XYLAN coated
Z = peripheral bolting ASME design
Handwheel
= w/o
HV = with handwheel (can not be combined with 1 and B
© ARCA Regler GmbH Kempener Straße 18 D-47918 Tönisvorst
Tel.: +49-(0)2156-7709-0 Fax: +49-(0)2156-7709-55
[email protected] www.arca-valve.com
TD_812_en_05-2023 - Subject to technical modifications - Page 5 of 5