Residential Solar PV Solutions
S6-GR1P(2.5-6)K-S
Solis Single Phase Inverters
     Models:
     S6-GR1P2.5K-S              S6-GR1P4.6K-S
     S6-GR1P3K-S                S6-GR1P5K-S
     S6-GR1P3.6K-S              S6-GR1P6K-S
     S6-GR1P4K-S
          Features:
          •   String current up to 16A            •   Light weight with compact design for easy
                                                      installation
          •   Integrated with zero export power
              control function                    •   2 MPPT design with precise MPPT algorithm
                                                                                                                                     Residential Solar PV Solutions
DATASHEET                                                                                                  S6-GR1P(2.5-6)K-S
Models                                                  2.5K              3K                      3.6K                  4K                    4.6K              5K                6K
Input DC
Recommended max. PV power                              3.75 kW          4.5 kW                   5.4 kW                6 kW                  6.9 kW           7.5 kW             9 kW
Max. input voltage                                                                                                     550 V
Rated voltage                                           250 V                                                                      330 V
Start-up voltage                                         60 V                                                                      100 V
MPPT voltage range                                    50-550 V                                                                    90-550 V
Max. input current                                                                                                  16 A / 16 A
Max. short circuit current                                                                                          22 A / 22 A
MPPT number/Max. input strings number                                                                                   2/2
Output AC
Rated output power                                     2.5 kW            3 kW                    3.6 kW                4 kW                  4.6 kW            5 kW              6 kW
Max. apparent output power                             2.5 kVA           3 kVA                   3.6 kVA               4 kVA                 4.6 kVA           5 kVA             6 kVA
Max. output power                                      2.5 kW            3 kW                    3.6 kW                4 kW                  4.6 kW            5 kW              6 kW
Rated grid voltage                                                                                             1/N/PE, 220 V / 230 V
Rated grid frequency                                                                                               50 Hz / 60 Hz
Rated grid output current                           11.4 A / 10.9 A   13.6 A / 13 A            16 A / 15.7 A       18.2 A / 17.4 A         20.9 A / 20 A   22.7 A / 21.7 A   27.3 A / 26.1 A
Max. output current                                     11.4 A           13.6 A                    16 A                18.2 A                 20.9 A           22.7 A            27.3 A
Power factor                                                                                              >0.99 (0.8 leading - 0.8 lagging)
                                                                                                                               y
THDi                                                                                                                    <3%
                                                                                                                             r
DC injection current                                                                                                 <0.5% In
                                                                                                                           a
Efficiency
                                                                                    n
Max. efficiency                                         97.3%                     97.3%                                            97.6%                                97.7%
                                                                                  i
EU efficiency                                           96.5%                     96.6%                                            97.1%                                97.1%
Protection
                                              i                                 m
DC reverse-polarity protection                                                                                          Yes
                                            l
Short circuit protection                                                                                                Yes
                                          e
Output over current protection                                                                                          Yes
                                         r
Surge protection                                                                                                        Yes
                                       P
Grid monitoring                                                                                                         Yes
Anti-islanding protection                                                                                               Yes
Temperature protection                                                                                                  Yes
Integrated AFCI (DC arc-fault circuit protection)                                                                       Yes (1)
Integrated DC switch                                                                                                    Yes
General Data
Dimensions (W*H*D)                                                                                               330*371*161 mm
Weight                                                                                8.2 kg                                                                    9 kg
Topology                                                                                                          Transformerless
Self-consumption (night)                                                                                               <1 W
Operating ambient temperature range                                                                                 -25 ~ +60°C
Relative humidity                                                                                                     0-100%
Ingress protection                                                                                                      IP66
Noise emission (typical)                                                                                             <20 dB(A)
Cooling concept                                                                                                 Natural convection
Max. operation altitude                                                                                               4000 m
Grid connection standard                                                 IEC 61683, IEC 60068, IEC 61727, IEC 62116, EN 50530, IS 16169 / IS 16221(BIS)
Safety/EMC standard                                                                                    IEC 62109-1/-2, IEC 61000-6-2/-3
Features
DC connection                                                                                                     MC4 connector
AC connection                                                                                                  Quick connection plug
Display                                                                                                             LED + APP
Communication                                                                                         RS485, USB, Optional: Wi-Fi, GPRS
(1) Activation required.