General Notices
for
Pipe Support Design
本文件內容為中鼎工程股份有限公司(中鼎)製作及所有之保密資料,受著
作權等相關法令保護,僅中鼎員工得於其特定職務及契約義務之工作範圍
內存取及使用,未經中鼎事先書面同意,不得將其中一部或全部重製、公
開散布或洩漏予與業務無關之人。
The content of this document is CONFIDENTIAL information made and owned by
CTCI Corporation (CTCI) and is protected by copyright laws and relevant
laws/regulations. Only employees of CTCI are allowed to access and use this
confidential information within the work scope under their specific and respective
duties and obligations required by agreement which is not allowed to copy,
reproduce, distribute publicly or disclose in whole or in part to any non-relevant
person without CTCI’s prior and written consent.
CERTIFIED
PROJ.
MGR DATE
PAGE
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
2 OF 43
REV.
0a
1.0 Specification and Standard
The following specification and standard for each project shall be followed.
2.1 Before starting pipe support design, check the stress list to identify whether the line
is critical line or not. All support location and function shall be based on stress
analysis results.
2.2 All pipe support type shall be selected from “Pipe Support Standard –02-TF1-08-
G01-9000-DE-SP-0006 “, “Pipe Support Standard for Cold Insulation –02-TF1-08-
G01-9000-DE-SP-0007” and refer to para. 3.0 “Application for Pipe Support
Standard ”.
2.3 If pipe supports are complicated or special required, then special support can be
used and drew in AutoCAD format of project specified border.
2.4 The numbering of special support (refer to Pipe Support Standard 02-TF1-08-G01-
9000-DE-SP-0006, P-3)
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
3 OF 43
REV.
0a
2.6 Support for horizontal lines, including insulated and bare lines, shall be furnished
with pipe shoes or saddles of 100mm minimum height for easily maintenance.
For some pipe materials, such as stainless, alloy, the clamped pipe shoe shall be
used.
For sloping lines, height of pipe shoe shall be modified to keep the slope and the
minimum height of pipe shoe (HOPS) shall be 50mm.
For F.F. lines, the distance between spray nozzle and support shall be Min. 400mm
for spray cover range requirement.
Notes:
Usage of clamped shoe & welded shoe shall follow contract specification.
If there is no such specification, then follow CTCI design rule:
˙ Use clamped shoe for 2” and below pipe.
˙ Use U-bolt or SAD-H for 2” and below tubing.
˙ Welded shoe for 3” above pipe.
2.7 For vertical line support, if line is insulated or 8” above bare lines, pipe shoe support
shall be designed. U-bolt is designed for 6” and below vertical bare line.
2.8 Following table shall be used to check or modify the length of pipe shoe(LOPS)
which is sufficient for axial thermal displacements, based on operating
temperature condition** :
2.9 Axial stop is considered if the length of straight pipe is longer than 4 times the
support span. Thermal expansion loop shall be used to keep maximum
displacement less than 200mm as following table
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
4 OF 43
REV.
0a
Length Between Two Axial Stop (m)
Operating Temperature
C.S. / A.S. S.S.
Below 180°C 200 150
180°C ~ 250°C 140 100
250°C and 400°C 80 60
2.10 For 24" and below, support type-52/54 is the first priority for guided support,
whereas type-53/55 is for support lift-off. For pipe size larger than 24”, type-53/55
shall be used both for guided and lift-off support. If type-53/55 is used, the
maximum upward thermal displacement shall be limited to 10mm.
2.11 For 2” & below C.S. lines, or 24”& below S.S, Alloy, PWHT, and Galv. C.S. lines,
clamped pipe shoe( support TYPE-54, 55, 67) is the first priority for resting and
guide support. Please refer to para. 2.35 “ Pipe shoe selection table” can be used
for general support design reference.
2.12 For high pressure steam(pressure rating >=1500#) lines, if graphite slide plate is
required by stress reason, due to graphite slide plate set is 35mm thick, the height
of pipe shoe(HOPS) shall be adjusted as below:
Height of Shoes
Insulation Th’k
(mm) Symbol
(mm)
(Say HOPS)
75 & Lesser 150 A
80 ~ 125 200 B
130 ~ 175 250 C
2.13 To select steel member size of support structure for standard types, para. 4.0
Attachment 1 “Member Size Selection Table” can be referred.
2.14 The maximum allowable deflection (sag) of process / utility lines due to the
sustained loads shall be 6mm / 12mm. General criteria for horizontal line support
on pipe rack is as below:
2.15 The maximum pipe support span in process area for normal case:
For Schedule 40 & STD. WT. or thicker pipe under 12mm deflection:
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
5 OF 43
REV.
0a
Tube For 2” and smaller tubing under 6mm deflection:
Size (in) 1/8” 3/16” 1/4” 3/8” 1/2” 5/8” 3/4” 7/8” 1” ~
Span (m) 0.5 0.9 0.9 0.9 1.5 1.5 1.5 1.5 2
SS
For Schedule 5S & 10S 、 thinner pipe and thicker pipe under 6mm deflection:
Vertical pipe
2.17 The first support of branch line from rack to area shall be resting support in general.
Guide support can be considered on the second support of branch line from rack
to area.
2.18 All stainless steel lines (including vertical line and horizontal or insulation and non-
insulation line) shall be supported with
2.18.1 Horizontal Lines: Clamped pipe shoe is preferred except axial stop which
shall use welded pipe shoe with stainless Reinf. Pad.
2.18.2 Vertical Lines: Clamped pipe shoe is preferred except support taking load.
If welded pipe shoe is used, following rules shall be referred:
A. For 3” & large lines, use stainless Reinf. Pad w/C.S. pipe shoe.
B. For 2” & below lines, use stainless material welded pipe shoe.
2.19 The first support of pump suction/discharge line shall be adjustable and kept close
to nozzle for pipe size 2” and larger (In-Line or free-standing pumps are not
required).
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
6 OF 43
REV.
0a
2.20 If pump (as in-line or free-standing types) is not fixed on foundation or structure, it
is necessary to design an anchor support in upstream of pump suction nozzle and
a guide support in downstream of pump discharge nozzle.
For pipe size 6" and below, one-trunnion support is considered. For 8" and above,
two-trunnions support should be considered. The local stress shall also be checked
according to sheets D-73 & 74 of pipe support standard.
2.22 The direction of trunnion pipe shall be indicated on piping isometric drawing. For
example, mark "North dir." for one trunnion, and "N-S dir." for two trunnions.
2.23 The trunnion pipe cannot be put on platform grating directly. It shall company with
pipe shoe or saddle and the loading shall act on the existing steel beam or support
structure. (For trunnion of TYPE 42, 43, pipe shoe is NOT required.)
2.24 For TYPE-16, 61 combined with frame steel (EX. TYPE-31…) acting on existing
structure:
2.24.1 If main line size is 14” and above, pipe shoe is required to combined with
TYPE-16, 61.
2.24.2 If main line size is 12” and below, pipe shoe is not required to combined
with TYPE-16, 61.
2.25 Support cannot be put on platform grating directly. All supports shall be rested,
guided or fixed on the existing beam or support structure. If there is no structure
beam under the support, it is required to add support structures (for 8” pipe and
below) or provide information to C&B discipline and ask C&B engineer to add a
beam(for 10” pipe and larger or structure span >2000mm).
The rod size M10 shall be used for 3” pipe and below, M12 for 4” & 6”.
The rod size for 8” and larger line shall be decided according to its piping loads.
If installation length(H) is longer than 2000 mm, A turnbuckle shall be provided for
vertical adjustment after erection.
2.27 For two-phase flow line, support shall be added and closed to the location where
pipe direction changed.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
7 OF 43
REV.
0a
2.28 Common support for two or more lines shall be shown on the upward or left side
pipe line on GA and isometric drawing. As illustrated in below figure(the line with
the mark NO.1).
TOS EL. XXX shall be marked on GA DWG. for the support of vertical piping. (Ex.
TYPE-25,26,35,36,37,39,42,43,44,45,46,47)
1.
2.
1. 31-L75-0302 1. 31-L75-0302
3. 66-3B 66-3B
2. 66-3B
3. 66-3B 2. 66-3B
1. 2. 3.
3. 66-3B
2.29 The supports located on the match line of area and pipe rack shall be marked on
the pipe rack arrangement drawing. The supports located on the match line of area
and area shall be marked on the east or north side of arrangement drawing.
NORTH
GA DWG.
EAST
A. Foundation information
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
8 OF 43
REV.
0a
D. Insert plate for concrete structure or steel structure with fireproofing
E. The above information or request shall consider the integral use and
design. For example, a stanchion can be designed to support
pipeline, cable tray, and electrical conduit at same location.
2.31 For all pipe material such as A.S., S.S., C.S., C.S. with PWHT, L.T.C.S., the
support designer has to take off the dummy pipe and reinforcing pad with the same
material as main line and mark on the ISO drawing.
2.32 Top level of a catch basin located at the low point of paving shall not be greater
than150mm below H.P.P. The call out and MTO of dummy pipe shall add 200mm
length to meet this required.(but keep the original 3D length in model)
2.33 Springs shall have a capacity that exceeds the calculated movement by a minimum
of 50%.
2.35 If base type spring loading is larger than 50000N, friction force shall be considered
in horizontal loads(use μ=0.1)
2.36 For pipeline spring support with a horizontal thermal displacement of 75 mm and
higher or a thermal cyclic piping system, use hanger type spring for support design
to reduce horizontal thermal friction force
2.37 For alignment purpose of pump with top-top of suction and discharge nozzle, when
spring support is used as the first support on the vertical pipe, the one(1) spring
design for the pipe size less and equal to 6” should be supported on top elbow of
pipe and two(2) springs for pipe size is larger or equal to 8” should be supported
from vertical pipe section.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
9 OF 43
REV.
0a
2.38 For RFCC plant, Reactor & Regenerator are very critical equipments and should
be careful for the piping stress analysis. The load cases shall include operating,
design and short term conditions which should cover all temperature range for
Reactor & Regenerator temperature in different operating conditions.
Due to large thermal movement of Reactor & Regenerator, the first constant spring
on the connecting pipe for top nozzles of Reactor & Regenerator should consider
40% or 50mm allowance. That is Total Travel = Actual Travel x 1.4 or Actual Travel
+ 50mm ; whichever is the largest
For other constant springs(other than the spring menioned above), 20% or 25mm
allowance (whichever is the largest) should be considered.
2.39 When designing the support of the reciprocating compressor piping, the following
items must be observed to prevent piping vibration.
2.39.1 The main pipes should be arrange to locate on the ground as possible.
So they can be supported from concrete sleepers on the ground.
2.39.3 Pipe should be support near heavy piping components and disconnected
locations, such as valves, because the large mass will reduce the natural
frequency of the piping system and induce vibrating.
2.39.5 The strength and stiffness of piping support must be increase. Do not
share the support with other utility piping to avoid the vibration transfer to
other pipes.
2.39.6 The piping system should use spring supports as less as possible. Using
rigid supports can increase the rigidity of piping system and control
thermal expansion effectively.
2.39.7 The static stress analysis loading and the manufacturer’s vibration
analysis loading must be given to civil department, and remind that this
load is related to the vibration load of the reciprocating compressor, and
an independent structure with sufficient rigidity must be design to support
the piping system to prevent vibration.
2.39.8 The pulsation force caused by fluid pulsation is likely to cause vibration at
the bending location. The initial piping arrangement should minimize the
number of bends. If piping space is allowed, a rigid support should be
installed near the bend to prevent vibration. However, the flexibility of
piping system must also be considered. The extra rigid supports which
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
10 OF 43
REV.
0a
are added to prevent piping vibration due to fluid pulsation will also
increase rigidity of piping system. This is conflict with solving the problem
of thermal expansion stress. It must be adjusted to adequate supports for
both piping flexibility and pulsation analysis.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
11 OF 43
REV.
0a
2.40 Pipe shoe selection table
TYPE HORIZONTAL
MATERIAL PIPE RACK PROCESS AREA
SIZE
Y G A 3-STOP Y G A 3-STOP
~1 1/2" 67 54 85 85 67 54 85 85
2"~12" 66 52/53 80 83 66 52/53 80 83
INSUL.
14"~24" 66 52/53 80+76 83+76 66 52/53 80+76 83+76
C.S. 26"~ 66+76 53+76 80+76 83+76 66+76 53+76 80+76 83+76
~1 1/2" 67 54 85 85 67 54 85 85
~1 1/2" 67 54 85 85 67 54 85 85
2"~12" 67 54/55 80 83 67 54/55 80 83
INSUL.
C.S. 14"~24" 67 54/55 80+76* 83+76* 67 54/55 80+76* 83+76*
GALV.
26"~ 66+76* 53+76* 80+76* 83+76* 66+76* 53+76* 80+76* 83+76*
K.C.S. ~1 1/2" 67 54 85 85 67 54 85 85
PWHT
NON 2"~12" 67 54/55 80 83 67 54/55 80 83
INSUL. 14"~24" 67 54/55 80+76* 83+76* 67 54/55 80+76* 83+76*
A.S. 26"~ 66-(A)+76* 53-(A)+76* 80-(A)+76* 83-(A)+76* 66-(A)+76* 53-(A)+76* 80-(A)+76* 83-(A)+76*
(D.T.<=371℃ ) ~1 1/2" 67 54 85-(A) 85-(A) 67 54 85-(A) 85-(A)
NON 2"~12" 66-(A) 52/53-(A) 80-(A) 83-(A) 66-(A) 52/53-(A) 80-(A) 83-(A)
INSUL. 14"~24" 66-(A) 52/53-(A) 80-(A)+76* 83-(A)+76* 66-(A) 52/53-(A) 80-(A)+76* 83-(A)+76*
A.S. 2"~6" 66-(A) 52/53-(A) 80-(A) 83-(A) 66-(A) 52/53-(A) 80-(A) 83-(A)
INSUL.
(D.T.>371℃ ) 8"~24" 66-(A) 52/53-(A) 80-(A)+76* 83-(A)+76* 66-(A) 52/53-(A) 80-(A)+76* 83-(A)+76*
26"~ 66-(A)+76* 53-(A)+76* 80-(A)+76* 83-(A)+76* 66-(A)+76* 53-(A)+76* 80-(A)+76* 83-(A)+76*
NON 2"~12" 66-(R) 52/53-(R) 80-(R) 83-(R) 66-(R) 52/53-(R) 80-(R) 83-(R)
INSUL. 14"~24" 66-(R) 52/53-(R) 80-(R)+76* 83-(R)+76* 66-(R) 52/53-(R) 80-(R)+76* 83-(R)+76*
26"~ 66-(R)+76 53-(R)+76* 80-(R)+76* 83-(R)+76* 66-(R)+76 53-(R)+76* 80-(R)+76* 83-(R)+76*
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
12 OF 43
REV.
0a
VERTICAL
TYPE
MATERIAL ALL AREA(EXCEPT UTILITY STATION)
SIZE 3-STOP G A
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
13 OF 43
REV.
0a
TYPE VERTICAL
MATERIAL ALL AREA(EXCEPT UTILITY STATION)
SIZE 3-STOP G A
~1 1/2" 59+52-(A) 52-(A) 59+66-(A)
2" 59+52-(A) 52-(A) 59+66-(A)
3"`~6" 59+52-(A) 3"`~6" 52-(A) 3"`~6" 61-T1*
A.S.
INSUL. 8"~12" 42(43)+(59+52-(A))x2 8"~20" 46(47)+52-(A)x2 8"~12" 61-T2*
(D.T.>371℃ ) 3"~24"
14" 42(43)+(59+52-(A)+76*)x2 22"~ SPECIAL 14"~24" 61-T2-(P)*
16"~24" 42(43)+60+(52-(A)+76*)x2
26"~ SPECIAL SPECIAL SPECIAL
~1 1/2" 59+52-(S) 54 59+66-(S)
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
14 OF 43
REV.
0a
B B
B
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
15 OF 43
REV.
0a
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
16 OF 43
REV.
0a
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
17 OF 43
REV.
0a
2.42 Support for Pump Suction Line
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
18 OF 43
REV.
0a
2.43 Support for Pump Discharge Line
Note 1: The adjustable support for line size ≧ 18” shall be designed to special type.
For adjustable support with guide, using support Type -01 and 87.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
19 OF 43
REV.
0a
2.44 Support for Tower Piping
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
20 OF 43
REV.
0a
2.45 Support for Level Gauge
a. When the total vertical length of stand pipe ≦ 2.0m, support is not required.
b. When the total vertical length of stand pipe > 2.0m and ≦ 5m, x, y, z
restrained support shall be provided on the upward 200mm of the stand pipe
center point (support type 26-L75-0203C, 59-*B-B and 57-*B-A).
c. When the total vertical length of stand pipe H > 5.0m, one support (26-L75-
0203C, 59-*B-B and 57-*B-A) on the ¼H vertical distance from top nozzle,
another support (26-L75-0203C and 57-*B-A) on the 1/4H vertical distance
from bottom nozzle.
d. Above support type is used for un-insulated stand pipe. When the line is
insulated, it’s preferred to use pipe shoe instead of U-bolt.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
21 OF 43
REV.
0a
2.46 Support for Heat Exchanger Piping
Case 3: (1) Standard support Type-15 can be provided and extended from top platform
/ floor.
(2) Pipe stanchion or Type-15 (with foundation) can be designed from ground
if no structure nearby.
(3) Hanger support Type-62 can be designed from the bottom of upper
structure.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
22 OF 43
REV.
0a
2.47 Support for Control Set (Case 1)
2” and above
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
23 OF 43
REV.
0a
Support for Control Set (Case 2)
2” and above
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
24 OF 43
REV.
0a
2.48 Support for PSV
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
25 OF 43
REV.
0a
S.S., No Insulation
X X
X X
X X
X X
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
26 OF 43
REV.
0a
3.0 Application for Pipe Support Standard:
3.1 Type-01 is applied to pipes above 2” (including), and can be used as anchor, guide
and resting support. If this type is used for a guide support, the direction of stop
shall be shown in the last letter of support tag( A: axial stop, G: guide, F: Axial stop
& guide).
N
01-4B-06E-F 01-4B-06E-G
* The lower component use foundation type for 14” and above.
3.2 When using Type-01 on pipe lines of all pipe materials such as alloy, stainless
steel, carbon steel, stress relief line…etc., support designer has to inform piping
designer to add a short pipe spool at the supporting point, and the short pipe (of
the same material as main line) has to be included into piping ISO MTO. For the
size of the short pipe, please refer to the description of Type-01 sheet of “Pipe
Support Standard”.
6
2"
3.3 Type-06 is designed for supporting 2” and below pipe. It is assembled by angle
steel that extended from equipment such as drum, tank…etc. Always use Type-06
combined with pipe shoe or Type-57 for guide support.
3.4 Type-09 & 10 are adjustable supports for the purpose of adjusting pipe during
nozzle alignment. They are suitable for support of low temperature pipeline
connected to rotating equipment. Type-09 is for pipe size 2” ~ 4”, and Type-10 is
for 6” ~ 16”. If the adjustable support needs a guide simultaneously, use Type-87
and combined with pipe shoe or dummy pipe support.
TYPE-27 TYPE-27
1500<H≦2500 TYPE-08 TYPE-15+FDN TYPE-15+FDN SPECIAL+FDN
(H125) (H125)
2500<H≦4000 TYPE-15+FDN TYPE-15+FDN TYPE-15+FDN TYPE-15+FDN TYPE-15+FDN STANCHION
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
27 OF 43
REV.
0a
If the height of support over 2500mm,Type-15 is suggested instead of Type-08,27,
because the maximum allowable height for it is up to 4000mm. Foundation is
required if using Type-15 on the ground.
3.6 When small pipe is over supporting span, and no nearby steel for support, support
Type-19 & Type-20 can be used by supporting from adjacent larger pipes.
If there are two or more pipes need be supported, as below figure, both sides need
large pipes to support together (Type-20).
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
28 OF 43
REV.
0a
The equivalent size (refer Attachment 2) also must meet at least two size no.
differential requirement.
3.6.1 C.S. bare pipe is preferred for supporting pipe(large size) and the min.
line size is 3”.
3.6.4 Before Civil pipe rack steel structure drawing IFC and piping design
information delivery deadline:
When the piping engineers design the route of 2" and below pipelines
entering or exiting the pipe rack, piping layout should be considered within
800 mm of both sides of the main beam or middle beam, and the standard
pipe support of the hanging type with L-shaped steel structure should be
designed by the piping engineers. If there are multiple pipelines extering
or exiting the pipe rack and arranged side by side and the horizontal
distance exceeds 800 mm, the loading information should be issued to
Civil engineers to design the supporting steel structures.
3.6.5 After Civil pipe rack steel structure drawing IFC and piping design
information delivery deadlines:
If the pipe route of 2" and below pipelines entering or exiting the pipe rack
are modified, and there are multiple pipelines arranged side by side and
the horizontal distance exceeds 800 mm, piping layout engineers must
actively discuss the pipe routes with piping stress engineers to design
these pipelines with special pipe support.
3.7 Type-21 is used to support 2” and below pipe. It is used for pipes above structure
and deviated from the supporting point.
3.8 Type-22 is used to support 2” and below pipe from the ground.
If the loading is large or the supported pipes are two or more, use Type-27 instead.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
29 OF 43
REV.
0a
3.9 Type-23 is used to support 2” and below pipe. It is used for pipes under structure
and deviated from the supporting point.
3.10 Type-25 is suitable for vertical pipe, and can be combined with U-bolt or pipe shoe
support. If the loading is large, use Type-26 instead.
3.11 For Type-27 (H-shape steel)if the loading exceeds allowable value or height is over
2500mm, use Type-15 with foundation instead.
3.12 For Type-30 to Type-34, the selection of these types in whole area shall be unified.
Try to keep them all support upward or downward for consistency. These support
types can be combined with Type-51 ~ 86.
3.15 For Type-37 ~ 47, there are two angles that can be selected, 30° and 45°. The
exception is when “H” ≦1140mm/1200mm of Type-45~47, the bracing is not
required, e.g. no angle should be selected.
3.16 It is prior for Type-37 ~ 47 to choose 30° for “Ø” value, but interference may exist
between lug plates or reinforced pads as illustrated below. To avoid this problem,
use 45° instead. If the support is from vertical vessel, 45° is the first priority to
reduce shell’s local stress.
INTERFERENCE
3.17 For Type-43, the space “Q” value shall be specified (Q=OD/2 + Insulation Thk +50).
This type shall be used together with other supports, such as Type-66 and 59,
Type-53 and 59, Type-61, Type-61 and 57.
3.18 The value of DIM “H” for Type-35 ~ 36 is in the unit of 100 mm.
The value of DIM “H” for Type-37 ~ 47 is in the unit of 1 mm.
because this “H” have to be exactly matching with the location of lug plate when
installing these support types onto equipment.
3.19 For a pipe with insulation, Type-52 is used for support with guide. The upward
thermal movement of pipe must be checked. If the upward thermal movement is
under 3 mm, use Type-52. If it is between 3 and 10 mm, use Type-53. If it is greater
than 10 mm, special support shall be used.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
30 OF 43
REV.
0a
Hard to keep the gap exactly in site,
"A" "A" use Type-53 to instead.
CV
001A SECTION "A"~"A"
3.20 Type-54 is used as guide for alloy or stainless steel pipe. Type-55 is selected as
the similar function of Type-53. The maximum temperature for the use of Type-54
& 55 is 750°F (400°C).
3.21 Those components denoted “NOT FURNISHED” in the standard should be called
out separately to compose a complete standard type set. For example: U-bolt in
Type-21, 22 is not included.
3.22 The material of down stopper plate in Type-59 is carbon steel (A283GR.C) in
general. If the main line is bare pipe and made of alloy or stainless steel, the down
stopper plate has to be of the same material as main line as illustrated below:
3.23 When using Type-61, please pay attention to the “NOTE” description in the
standard. Loading and bearing stress on trunnion support of Type-61 shall not
exceed allowable value, especially for the stress under hydraulic test case as
illustrated below:
3.24 Type-62 includes various hanger type supports and they can only resist downward
loading. Pay attention for the temperature and pipe size range shown on the table.
3.25 Type-66 is the pipe shoe. The height of pipe shoe varies with insulation thickness
(refer to table A, B). And the material varies with those of main line. For pipe size
24” and below, the reinforced pad is optional; for 26” and larger, the reinforced pad
is mandatory. The pad material shall be marked on piping isometrics if the material
is not carbon steel.
3.26 Type-67 can be selected for the non-welding pipe with temperature below 750°F
(400°C).
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
31 OF 43
REV.
0a
3.27 Type-73 is used for reciprocating compressor pipelines.
3.28 Type-76 is used as reinforcing pad to avoid local stress concentration. Besides,
the bearing stress has to be checked in the meantime.
3.29 Axial stop can be selected between Type-56, 80(Reinforced pad required if Type-
56 is used for pipe on pipe rack ). Refer to Type-66 for pipe shoe data.
3.30 Type-82, 83 are used for x, y, z 3-way stop (Reinforced pad required if Type-56 is
used for pipe on pipe rack ).
Type-85 is used as anchor.(Only in combination with Type-20, and axial stop for 1
1/2” and below).
Type-56 & 82 are used for non-insulation pipe. (Reinforced pad required for special
material pipe such as alloy, stainless steel, and stress relief line…etc.)
3.31 For axial stop Type-80, 83, the pipe shoe HOPS and LOPS shall be specified to
suit the size of beam.
3.32 The combination of Type-87 and other support type has the same function of Type-
9, 10 (refer to 3.4).
3.33 Type 101 Gusset Support has been indicated in the above ground piping standard
(D7TS-100-E, STD. NO. D7TS-100.37A-E), the material is captured by 3D Model
and then summited to the stress group for purchase.
It’s used for the small bore connection (1 1/2” and smaller) to compressor
(centrifugal and reciprocating) suction and discharge lines, from or to the first
equipment item (suction drum, discharge cooler etc.), and the high pressure steam
and BFW system.
3.34.1 Type 102-XB-A, hold down with guide support (3mm gap).
3.34.2 Type 102-XB-B, hold resting support (50mm gap), when use it, should be
confirm lateral displacement small than 50mm.
3.36 Type-104 is used as the first support for the inlet and outlet pipe near compressor.
3.37 Type-105 is used when there is no existing structure steel member available for
supporting. If loads are higher than 1000kg, further review by civil discipline is
necessary.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
32 OF 43
REV.
0a
3.38.1 Slide plate is used for rigid support. The dimension of upper and lower
plate shall be considered as below:
SLIDE PLATE CHOOSING TABLE
BASE PLATE SLIDE PLATE
DUMMY SIZE
LINE SIZE / STEEL /PIPE SHOE
SUPPORT TYPE /STEEL UPPER PLATE LOWER PLATE 最大水平位移量
SIZE (POLS X
WIDTH (AxB) (LxW)
WIDE)
TYPE-01 2"~4" 1 1/2"~3" 150 SQ 120 SQ 70 SQ 25
6"~ 8" 4"~6" 230 SQ 200 SQ 100 SQ 50
10"~16" 8"~10" 330 SQ 300 SQ 200 SQ 50
18"~24" 12" 380 SQ 350 SQ 250 SQ 50
26"~28" 14" 410 SQ 350 SQ 250 SQ 50
30"~32" 16" 460 SQ 400 SQ 300 SQ 50
34"~40" 20" 560 SQ 500 SQ 400 SQ 50
42" 24" 660SQ 600 SQ 400 SQ 50
1. There is a rule for slide plate that is PTFE plate shall not out of upper slide plate edge whenever
installation or operation.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
33 OF 43
REV.
0a
2 Double slide plate sets for 44"~80" pipe shoe shall be installed under vertical rib, please see attached
reference drawing
3.38.2 Slide plate Type-B(M-60A) is used for spring support if spring’s load flange
bonded with PTFE slide plate(supplied by spring by vendor). It should be
double checked for pipe horizontal movement to prevent PTFE plate out
of slide plate’s edge in operation condition.
Below are application guide for standard support type of COLD insulation line:
3.40 In TYPE-01C, it can be selected from SH’T N-9 for function of support: ANCHOR,
SLIDE or GUIDE. This type is suitable for 1-1/2” and smaller lines only.
3.41 TYPE-02C is used for 2”~24” lines, it can be ANCHOR, GUIDE or SLIDE.
3.42 From TYPE-06C to TYPE-10C, the suitable temperature is from -9℃ to -254℃.
The suitable line size is as follows :
3.43 TYPE-08C is used for ANCHOR or GUIDE. (TYPE-08C can not be used for
ANCHOR support if large ANCHOR FORCE of CRITICAL PIPE was considered.)
3.44 TYPE-03C, 04C, 09C and 10C are used for SLIDE and adjustable support only,
not for ANCHOR or GUIDE.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
34 OF 43
REV.
0a
3.45 TYPE-11C and 13C are usually used for the RESTING (SLIDE) support of
horizontal pipes, TYPE-11C is used for 24” and smaller, TYPE-13C for 26” and
above.
3.46 Designer should follow the pipe size and the thickness of cold insulation to decide
the CRADLE NO. of TYPE-11C.It is required to consider the movement of
contraction and choose sufficient CRADLE LENGTH. PRESET also could be used
if the CRADLE LENGTH is insufficient. (It means that install the cradle support at
the opposite direction of the cold contraction).
3.47 TYPE-12C is used for the Horizontal support of pipes without CRADLE SHOE. It
is suitable for the support of Dummy (TRUNNION PIPE).
3.48 TYPE-13C is used for the resting support of 26” and above lines. The length of
CRADEL is A : 400mm or B : 600mm, Please refer to Para 3.46 for other
instructions.
3.49 TYPE-15C is used for the GUIDE support of vertical pipes, and also used on
horizontal lines for SINGLE ROD HANGER(TYPE-120C).
3.50 TYPE-17C is used for the GUIDE SUPPORT of 24” and smaller lines. The
CRADLE NO. is also selected by the INSULATION THICKNESS and PIPE SIZE
in TYPE-11C. Please refer to Para 3.46 for other instructions. Need to extend the
cradle length to avoid the interference between clamp lug and thermal movement.
3.51 TYPE-19C is the TRUNNION SUPPORT used at ELBOW. It includes END PLATE
and TYPE-11C. The material of TRUNNION PIPE should be the same as main
pipe and shown on piping ISO.
3.52 Please follow the table below to select type of support in different situations.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
35 OF 43
REV.
0a
3.53 Load capacity is need to be checked when using TYPE-23C, 24C.
3.54 TYPE-26C is used for the TRUNNION SUPPORT on vertical pipes. It includes
END PLATE and TYPE-12C. The material of TRUNNION PIPE should be the same
as main pipe and shown on piping ISO.
3.55 TYPE-115C is used for GUIDE SUPPORT of vertical lines. It includes TYPE-15C
CRADLE and supporting structure.
3.56 TYPE-121C is use for GUIDE SUPPORT of 26” and above lines.
3.57 Use TYPE-115C and TRUNNION PIPE with END PLATE for AXIAL STOP
SUPPORT. The material of TRUNNION pipe should be the same as main pipe and
shown on piping ISO.
3.58 For C.S. pipe with anti-sweat insulation, use TYPE-131C to TYPE-133C. The
temperature (Ope. and Design) range is 20oC~-20oC, and Insulation TH'K 51mm.
(Corresponding to insulation C4 and N4, Th’k 51mm)
3.59 For S.S. or Galv. C.S.pipe with anti-sweat insulation, use TYPE-137C to TYPE-
138C. The temperature (Ope. and Design) range is 20oC~-20oC, and Insulation
TH'K 51mm. (Corresponding to insulation C4 and N4, Th’k 51mm)
3.60 For L.T.C.S. or S.S. bare pipe on vent or drain line, use TYPE-134C to TYPE-136C,
when short term Temp. <-20 oC, and cold insulation thickness 51mm.
(Corresponding to insulation C4 and N4, Th’k 51mm)
3.61 For all pipe materials such as alloy, S.S., Galv., C.S., and C.S. with PWHT,
L.T.C.S., support designer has to take off the dummy pipe and reinforcing pad
with the same material as main line and mark on the ISO drawing.
3.62 The cradle no of trunnion/dummy pipe shall be chosen from the cold insulation
thickness based on operating temperature of main line.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
36 OF 43
REV.
0a
3.63 Cold and Hot Support Comparison Table
Refer to the following table for choosing cold support type. It should be adjusted
by actual plant design.
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
37 OF 43
REV.
0a
Horizontal pipe support
112C ~ 24" 39 ~24"
(for cold vessel)
Horizontal pipe support
113C ~ 2" 36 ~8"
(for cold vessel)
45 ~24" Riser Guide (for hot
114C ~ 24"
47 ~20" vessel & cold pipe)
44 ~24" Riser Guide (for steel &
115C ~ 24"
46 ~20" cold pipe)
25+(57-
116C ~ 2" ~ 2" Riser Anchor
xB-B)
117C ~ 2" 25 ~ 4" Riser Guide Steel
For support passing
119C
through vessel skirt
120C ~ 24" 62 ~24" Hanger Rod Support
121C 26" ~ 53 ~78" Guide
Resting, anti-sweat(CS
131C ~24" 20°C~-40°C 66 ~78"
pipe), Th’k 51mm use
Guide, anti-sweat(CS
132C ~24" 20°C~-40°C 52,53 ~78"
pipe) , Th’k 51mm use
Anchor, anti-sweat(CS
133C ~24" 20°C~-40°C 85 ~42"
pipe) , Th’k 51mm use
Short term Resting, anti-sweat(SS
134C ~24" 66- -(S) ~78"
below -40°C pipe) , Th’k 51mm use
Short term 52- -(S) ~24" Guide, anti-sweat(SS
135C ~24"
below -40°C 53- -(S) ~78" pipe) , Th’k 51mm use
Short term Anchor, anti-sweat(SS
136C ~24" 85- -(S) ~42"
below -40°C pipe) , Th’k 51mm use
Resting, anti-sweat(Clamp
137C* ~24" 20°C~-40°C 67 ~42"
type) , Th’k 51mm use
54 ~24" Guide, anti-sweat(Clamp
138C* ~24" 20°C~-40°C
55 ~42" type) , Th’k 51mm use
Horizontal pipe axial
Dummy+115C ~24" 83 ~42"
support
Note: * 1. For S.S. pipe, if the piping thickness > Sch 10S and pipe size >=3”, using 134C, 135C replaced for 137C, 138C
2. For S.S. insulation pipe, if the piping thickness <= Sch 10S, and 12”(and) above, using 134C, 135C replaced for 137C, 138C
3. Need to refer to the material specification for piping thickness
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
38 OF 43
REV.
0a
3.64 Cradle Selection Table
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
39 OF 43
REV.
0a
4.0 Attachment:
Attachment 1 Member Size Selection Table
2. TYPE-25
Equivalent Member Size "M"
Line Size L≦800
NPS "D" H≦800 500<H≦1200
3/4 L50 L75
1 L50 L75
1 1/2 L75 L75
2 L75 L75
3 L75 L75
4 L75 L75
3. TYPE-26
Equivalent Member Size "M"
Line Size 500<L≦1000 1000<L≦1500
NPS "D" H≦1000 1000<H≦1500 H≦1000 1000<H≦1500
3/4 X L75 X X
1 X L75 X X
1 1/2 X L75 X X
2 X L75 X X
3 X L75 X X
4 X L75 C125 C125
6 L75 C125 C125 C125
8 L75 C125 C125 C125
Note: The member sizs shall be reconsideration for down stop support.
4. TYPE-27
Equivalent Member Size "M"
Line Size L≦500
NPS "D" H≦500 500<H≦1000 1000<H≦1500 1500<H≦2500
3/4 L50 L75 L75 NOTE 1
1 L50 L75 L75 NOTE 1
1 1/2 L75 L75 L75 NOTE 1
2 L75 L75 L75 NOTE 1
3 L75 L75 L100 NOTE 1
4 L75 L75 L100 NOTE 1
6 L75 L100 L100 H125
8 L100 L100 H125 H125
10 H125 H125 H125 -
12 H125 H125 H125 -
Note 1: Choosing TYPE-08 instead of TYPE-27
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
40 OF 43
REV.
0a
5. TYPE-28 / TYPE-31 / TYPE-32 / TYPE-33 / TYPE-34
Equivalent H (Max)
Member Size "M"
Line Size
NPS "D" L (Max) 500 1000 1500
2 500 L50 L50 L75
3 500 L50 L50 L75
4 500 L75 L75 L75
4 1000 L75 L75 L75
6 500 L75 L75 L75
6 1000 L75 L75 L75
8 500 L75 L75 C125
8 1000 C125 C125 C125
10 500 C125 C125 C125
10 1000 C125 C125 C125
12 500 C125 C125 C150
12 1000 C125 C125 C150
14 500 C125 C125 C150
14 1000 C125 C125 C150
16 1000 C150 C150 C150
16 1500 C150 C150 C150
18 1000 C150 C150 C150
18 1500 C150 C150 C150
20 1000 C150 C150 C150
20 1500 C150 C150 C150
24 1000 C150 C150 X
24 1500 C150 C150 X
6. TYPE-30
Equivalent H (Max)
Member Size "M"
Line Size
NPS "D" L (Max) 500 1000 1500
3/4 500 L50 L50 L75
1 500 L50 L50 L75
1 1/2 500 L75 L75 L75
2 500 L75 L75 L75
3 500 L75 L75 L75
4 500 L75 L75 C150
4 1000 L75 L75 C150
6 500 L75 C150 C150
6 1000 L75 C150 C150
8 500 C150 C150 C150
8 1000 C150 C150 C150
10 500 C150 C150 C150
10 1000 C150 C150 C150
12 500 C150 C150 C150
12 1000 C150 C150 C150
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
41 OF 43
REV.
0a
7. TYPE-35 8. TYPE-37
Equivalent Equivalent
Member Size "M" Member Size "M"
Line Size Line Size
NPS "D" H≦500 500<H≦1000 NPS "D" H≦1000 1000<H≦1500 1500<H≦2000
3/4 L50 L75 3/4 ~ 4 X L75 H100
1 L50 L75 6 X C100 H100
1 1/2 L75 L75 8 X C100 H100
2 L75 L75 10 C125 H100 H125
3 L75 L75 12 C125 H100 H125
4 L75 C100 14 C125 H100 H125
6 C100 C125 16 H100 H125 H150
8 C125 C150 18 H100 H125 H150
20 H100 H125 H150
24 H100 H125 H150
9. TYPE-44 / TYPE-46
Equivalent
Member Size "M"
Line Size
NPS "D" H≦500 500<H≦1000 1000<H≦1500 1500<H≦2000
10 C100 C125 C150 C150
12 C125 C125 C150 C150
14 C125 C150 C150 C150
16 C150 C150 C150 X
18 C150 C150 C150 X
20 C150 C150 X X
24 C150 X X X
23E5220A
General Notices DATE
for Pipe Support Design 07/2023
42 OF 43
REV.
0a
Attachment 2 CALCULATION CHART FOR EQUIVALENT SIZE BY PIPE WEIGHT