0% found this document useful (0 votes)
1K views103 pages

Dialux Illumination Project Report

The document is a report on an illumination project conducted using Dialux software. It includes a table of contents listing sections on project description, luminaire specifications, lighting plans and calculations for three bedrooms in a building on a site. The report provides lighting design details for different areas of a multi-room building project modeled in Dialux illumination design software.

Uploaded by

fancyreymart
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views103 pages

Dialux Illumination Project Report

The document is a report on an illumination project conducted using Dialux software. It includes a table of contents listing sections on project description, luminaire specifications, lighting plans and calculations for three bedrooms in a building on a site. The report provides lighting design details for different areas of a multi-room building project modeled in Dialux illumination design software.

Uploaded by

fancyreymart
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 103

Date 12/13/2023

Dialux Illumination Project

BISU-MC BSEE 4A GROUP 8

Created with DIALux


Dialux Illumination Project

Preface

Notes on planning:

The energy consumption quantities do not take into account light


scenes and their dimming levels.
Dialux Illumination Project

Table of Contents

Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6. . . . . . . . . . . . . . . . . . . . . . . . . . .
Images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8. . . . . . . . . . . . . . . . . . . . . . . . . . .

Product data sheets


Zero - Allright Ceiling 180mm (Aluminum) (1x LED 3000K) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Zero - Allright Ceiling 400mm (Dark Grey) (1x LED 3000K) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 .............................
Zero - Allright Wall 365mm (Dark Grey) (1x LED 3000K) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .............................
11
Zero - Fisherman Pendant 650mm (Orange) (1x TC-TELI 42W/830) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 .............................
Zero - Lens Pendant 180mm (Black) (1x LED 3000K) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 ............................
Zero - XM Ceiling (White) (1x LED 3000K) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
.............................

Site 1
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 .............................
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
............................

Site 1

Building 1
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
............................

Site 1 - Building 1

Storey 1
Room list / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 .............................
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24............................
Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25............................

Site 1 - Building 1 - Storey 1

BEDROOM 1
Summary / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 .............................
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .............................
29
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................
31
Dialux Illumination Project

Table of Contents

Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32............................


Working plane (BEDROOM 1) / Light scene 1 / Perpendicular illuminance . . . . . . . . . . . . . . . . . . . . . . . . . . . 34. . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
(adaptive)

Site 1 - Building 1 - Storey 1

BEDROOM 2
Summary / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 .............................
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 .............................
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 ............................
Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40 ............................
Working plane (BEDROOM 2) / Light scene 1 / Perpendicular illuminance . . . . . . . . . . . . . . . . . . . . . . . . . . . 42. . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
(adaptive)

Site 1 - Building 1 - Storey 1

BEDROOM 3
Summary / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 .............................
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 .............................
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
47 ............................
Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
48 ............................
Working plane (BEDROOM 3) / Light scene 1 / Perpendicular illuminance . . . . . . . . . . . . . . . . . . . . . . . . . . . 50. . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
(adaptive)

Site 1 - Building 1 - Storey 1

BEDROOM 4
Summary / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 .............................
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .............................
53
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................
55
Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56............................
Working plane (BEDROOM 4) / Light scene 1 / Perpendicular illuminance . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 .............................
(adaptive)

Site 1 - Building 1 - Storey 1

COMFORT ROOM 2
Summary / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 .............................
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .............................
61
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................
63
Dialux Illumination Project

Table of Contents

Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64


............................
Working plane (COMFORT ROOM 2) / Light scene 1 / Perpendicular illuminance . . . . . . . . . . . . . . . . . . . . . 66. . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
(adaptive)

Site 1 - Building 1 - Storey 1

CR 1
Summary / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 .............................
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69 .............................
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71 ............................
Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
72 ............................
Working plane (CR 1) / Light scene 1 / Perpendicular illuminance (adaptive) . . . . . . . . . . . . . . . . . . . . . . . . . 74. . . . . . . . . . . . . . . . . . . . . . . . . . . .
.

Site 1 - Building 1 - Storey 1

LAUNDY, HALLWAY, LIVING, DINING ROOM


Summary / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 .............................
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .............................
77
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................
86
Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87............................
Working plane (LAUNDY, HALLWAY, LIVING, DINING ROOM) / Light scene 1 / . . . . . . . . . . . . . . . . . . . . . . . . 89. . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
Perpendicular illuminance (adaptive)

Site 1 - Building 1 - Storey 1

MASTER BEDROOM
Summary / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 .............................
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .............................
92
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................
94
Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95............................
Working plane (MASTER BEDROOM) / Light scene 1 / Perpendicular illuminance . . . . . . . . . . . . . . . . . . . . .97 .............................
(adaptive)

Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
.............................
Dialux Illumination Project

Description

This is the Residential Building at 0020 Lower Santo Niño St.

6
Dialux Illumination Project

Images

Project

Project

Project

7
Dialux Illumination Project

Luminaire list

Φtotal Ptotal Luminous efficacy


23119 lm 384.0 W 60.2 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

16 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm 63.0 lm/W

1 Zero 7407398 Allright Ceiling 400mm (Dark Grey) 26.0 W 1884 lm 72.5 lm/W

2 Zero 7421398 Allright Wall 365mm (Dark Grey) 11.0 W 510 lm 46.4 lm/W

4 Zero 8081101 XM Ceiling (White) 17.0 W 1065 lm 62.7 lm/W

2 Zero 8102106 Lens Pendant 180mm (Black) 9.0 W 475 lm 52.8 lm/W

1 Zero 8187341 Fisherman Pendant 650mm (Orange) 42.0 W 1838 lm 43.8 lm/W

8
Dialux Illumination Project

Product data sheet

Zero - Allright Ceiling 180mm (Aluminum)

Article No. 7407138

P 13.0 W

ΦLuminaire 819 lm

Luminous efficacy 63.0 lm/W

CCT 3000 K

CRI 80 Polar LDC

Takarmatur i naturanodiserad aluminium, natur, mörkgrå- eller


bronslackerad. Bländskydd av prismatisk akryl. LED information: LED
info: Systemeffekt 13W. Armaturlumen 816LM. Korrelerad
färgtemperatur 3000K. Färgtolerans SDCM 3. Färgåtergivning RA 80

Finish: Anodized aluminium, natural, bronze or dark grey painted and


white painted steel. Diffuser in prismatic acrylic.
LED info: System power: 13W. Luminaire Luminous Flux: 816LM. CCT
3000K. SDCM 3. CRI 80.
Installation: Ceiling-installation.
Connection: Terminal block. D108 mm 3x4mm2. . D400 mm 5x4mm2,
two entry holes.
Design: Per Sundstedt

UGR diagram (SHR: 0.25)

9
Dialux Illumination Project

Product data sheet

Zero - Allright Ceiling 400mm (Dark Grey)

Article No. 7407398

P 26.0 W

ΦLuminaire 1884 lm

Luminous efficacy 72.5 lm/W

CCT 3000 K

CRI 80 Polar LDC

Dikt tak. Takarmatur i natureloxerad aluminium, natur alt. brons eller


mörkgrå lackerad. Prismatisk avbländningsskiva. Närvarosensor och
nödljus finns som tillbehör.

Finish: Anodized aluminium, natural, bronze or dark grey painted and


white painted steel. Diffuser in prismatic acrylic.
LED info: System power: 17W or. 26W. Luminaire Luminous Flux:
1400LM or 1937LM. CCT 3000K. SDCM 3. CRI 80.
Installation: Ceiling-installation.
Connection: Terminal block. D108 mm 3x4mm2. . D400 mm 5x4mm2,
two entry holes

UGR diagram (SHR: 0.25)

10
Dialux Illumination Project

Product data sheet

Zero - Allright Wall 365mm (Dark Grey)

Article No. 7421398

P 11.0 W

ΦLuminaire 510 lm

Luminous efficacy 46.4 lm/W

CCT 3000 K

CRI 80 Polar LDC

Anodized aluminium, natural or painted in bronze or dark grey color.


Prismatic diffuser.

Finish: Anodized aluminium, natural, bronze or dark grey painted and


white painted steel. Diffuser in prismatic acrylic.
Installation: Wall installation.
Connection: Terminal block 3x4mm2.
LED info: System power: 11W. Luminaire Luminous Flux: see above.
CCT 3000K. SDCM 3.
Design: Per Sundstedt

11
Dialux Illumination Project

Product data sheet

Zero - Fisherman Pendant 650mm (Orange)

Article No. 8187341

P 42.0 W

ΦLamp 3200 lm

ΦLuminaire 1838 lm

η 57.44 %

Luminous efficacy 43.8 lm/W Polar LDC

CCT 3000 K

CRI 85

Finish: Shade in opal UV-stable polyethene. Handmade net in white,


orange or natural. Other colors on request.
Installation: Pendant, 1,9 m cable and rope.
Connection: Terminal block 3x2,25mm2 ,. When HFF 5x4mm2.
Design: Mattias Ståhlbom 2011.

UGR diagram (SHR: 0.25)

12
Dialux Illumination Project

Product data sheet

Zero - Lens Pendant 180mm (Black)

Article No. 8102106

P 9.0 W

ΦLuminaire 475 lm

Luminous efficacy 52.8 lm/W

CCT 3000 K

CRI 80 Polar LDC

Finish: Structure painted aluminum and matt acrylic.


Installation: Ceiling-hook.
Connection: Terminal block 3x2,25mm when HFF cable without plug.
LED info: System power: 21W. Luminaire Luminous Flux: 973LM. CCT
3000K. SDCM 3. CRI 80.
Design: Jens Fager 2010

UGR diagram (SHR: 0.25)

13
Dialux Illumination Project

Product data sheet

Zero - XM Ceiling (White)

Article No. 8081101

P 17.0 W

ΦLuminaire 1065 lm

Luminous efficacy 62.7 lm/W

CCT 3000 K

CRI 80 Polar LDC

Ceiling/wall Base in white painted aluminium. Matt opal glass and


shade in expanded metal, white, black or copper. Motion detector
available as accessory. Terminal block 5x4mm2.

Finish: Base in white painted aluminium. Matt opal glass and shade in
expanded metal, white, black or copper.
Installation: Ceiling or wall.
Connection: Terminal block 5x4mm2.
Design: Joel Karlsson, Krook & Tjäder Design 2011.

UGR diagram (SHR: 0.25)

14
Dialux Illumination Project

Site 1
Luminaire layout plan

15
Dialux Illumination Project

Site 1
Luminaire layout plan

Manufacturer Zero P 13.0 W

Article No. 7407138 ΦLuminaire 819 lm

Article name Allright Ceiling


180mm (Aluminum)

Fitting 1x LED 3000K

1 x Zero Allright Ceiling 180mm (Aluminum)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 13.742 m / 2.254 m /
3.440 m 13.742 m 2.254 m 3.440 m 1

X-direction 1 pcs., Centre - centre,


0.450 m

Y-direction 1 pcs., Centre - centre,


0.500 m

Arrangement A1

1 x Zero Allright Ceiling 180mm (Aluminum)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 2.821 m / -1.368 m /
2.900 m 2.821 m -1.368 m 2.900 m 2

X-direction 1 pcs., Centre - centre,


0.450 m

Y-direction 1 pcs., Centre - centre,


0.500 m

16
Dialux Illumination Project

Site 1
Luminaire layout plan

Arrangement A2

17
Dialux Illumination Project

Site 1
Luminaire list

Φtotal Ptotal Luminous efficacy


1632 lm 26.0 W 62.8 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

2 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm 63.0 lm/W

18
Dialux Illumination Project

Building 1
Luminaire list

Φtotal Ptotal Luminous efficacy


21487 lm 358.0 W 60.0 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

14 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm 63.0 lm/W

1 Zero 7407398 Allright Ceiling 400mm (Dark Grey) 26.0 W 1884 lm 72.5 lm/W

2 Zero 7421398 Allright Wall 365mm (Dark Grey) 11.0 W 510 lm 46.4 lm/W

4 Zero 8081101 XM Ceiling (White) 17.0 W 1065 lm 62.7 lm/W

2 Zero 8102106 Lens Pendant 180mm (Black) 9.0 W 475 lm 52.8 lm/W

1 Zero 8187341 Fisherman Pendant 650mm (Orange) 42.0 W 1838 lm 43.8 lm/W

19
Dialux Illumination Project

Building 1 · Storey 1 (Light scene 1)


Room list

20
Dialux Illumination Project

Building 1 · Storey 1 (Light scene 1)


Room list

BEDROOM 1

Ptotal ARoom Lighting power density Ēperpendicular (Working plane)


13.0 W 9.38 m² 1.39 W/m² = 4.82 W/m²/100 lx (Room) 28.8 lx

pcs. Manufacturer Article No. Article name P ΦLuminaire

1 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm

BEDROOM 2

Ptotal ARoom Lighting power density Ēperpendicular (Working plane)


13.0 W 6.93 m² 1.88 W/m² = 6.06 W/m²/100 lx (Room) 31.0 lx

pcs. Manufacturer Article No. Article name P ΦLuminaire

1 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm

BEDROOM 3

Ptotal ARoom Lighting power density Ēperpendicular (Working plane)


17.0 W 7.03 m² 2.42 W/m² = 6.64 W/m²/100 lx (Room) 36.4 lx

pcs. Manufacturer Article No. Article name P ΦLuminaire

1 Zero 8081101 XM Ceiling (White) 17.0 W 1065 lm

21
Dialux Illumination Project

Building 1 · Storey 1 (Light scene 1)


Room list

BEDROOM 4

Ptotal ARoom Lighting power density Ēperpendicular (Working plane)


17.0 W 5.06 m² 3.36 W/m² = 8.47 W/m²/100 lx (Room) 39.6 lx

pcs. Manufacturer Article No. Article name P ΦLuminaire

1 Zero 8081101 XM Ceiling (White) 17.0 W 1065 lm

COMFORT ROOM 2

Ptotal ARoom Lighting power density Ēperpendicular (Working plane)


26.0 W 3.36 m² 7.74 W/m² = 10.84 W/m²/100 lx (Room) 71.4 lx

pcs. Manufacturer Article No. Article name P ΦLuminaire

2 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm

CR 1

Ptotal ARoom Lighting power density Ēperpendicular (Working plane)


13.0 W 2.36 m² 5.51 W/m² = 9.61 W/m²/100 lx (Room) 57.3 lx

pcs. Manufacturer Article No. Article name P ΦLuminaire

1 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm

22
Dialux Illumination Project

Building 1 · Storey 1 (Light scene 1)


Room list

LAUNDY, HALLWAY, LIVING, DINING ROOM

Ptotal ARoom Lighting power density Ēperpendicular (Working plane)


242.0 W 64.59 m² 3.75 W/m² = 4.25 W/m²/100 lx (Room) 88.1 lx

pcs. Manufacturer Article No. Article name P ΦLuminaire

9 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm

1 Zero 7407398 Allright Ceiling 400mm (Dark Grey) 26.0 W 1884 lm

2 Zero 7421398 Allright Wall 365mm (Dark Grey) 11.0 W 510 lm

1 Zero 8081101 XM Ceiling (White) 17.0 W 1065 lm

2 Zero 8102106 Lens Pendant 180mm (Black) 9.0 W 475 lm

1 Zero 8187341 Fisherman Pendant 650mm (Orange) 42.0 W 1838 lm

MASTER BEDROOM

Ptotal ARoom Lighting power density Ēperpendicular (Working plane)


17.0 W 9.81 m² 1.73 W/m² = 4.56 W/m²/100 lx (Room) 38.0 lx

pcs. Manufacturer Article No. Article name P ΦLuminaire

1 Zero 8081101 XM Ceiling (White) 17.0 W 1065 lm

23
Dialux Illumination Project

Building 1 · Storey 1
Luminaire list

Φtotal Ptotal Luminous efficacy


21487 lm 358.0 W 60.0 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

14 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm 63.0 lm/W

1 Zero 7407398 Allright Ceiling 400mm (Dark Grey) 26.0 W 1884 lm 72.5 lm/W

2 Zero 7421398 Allright Wall 365mm (Dark Grey) 11.0 W 510 lm 46.4 lm/W

4 Zero 8081101 XM Ceiling (White) 17.0 W 1065 lm 62.7 lm/W

2 Zero 8102106 Lens Pendant 180mm (Black) 9.0 W 475 lm 52.8 lm/W

1 Zero 8187341 Fisherman Pendant 650mm (Orange) 42.0 W 1838 lm 43.8 lm/W

24
Dialux Illumination Project

Building 1 · Storey 1 (Light scene 1)


Calculation objects

25
Dialux Illumination Project

Building 1 · Storey 1 (Light scene 1)


Calculation objects

Working planes

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (CR 1) 57.3 lx 42.2 lx 68.6 lx 0.74 0.62 WP1


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Working plane (BEDROOM 4) 39.6 lx 23.8 lx 52.4 lx 0.60 0.45 WP2


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Working plane (COMFORT ROOM 2) 71.4 lx 8.50 lx 86.5 lx 0.12 0.098 WP3
Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Working plane (MASTER BEDROOM) 38.0 lx 14.0 lx 72.8 lx 0.37 0.19 WP4
Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Working plane (BEDROOM 1) 28.8 lx 12.9 lx 45.3 lx 0.45 0.28 WP5


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Working plane (BEDROOM 2) 31.0 lx 14.1 lx 45.0 lx 0.45 0.31 WP6


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Working plane (BEDROOM 3) 36.4 lx 18.2 lx 54.3 lx 0.50 0.34 WP7


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Working plane (LAUNDY, HALLWAY, LIVING, DINING 88.1 lx 14.6 lx 474 lx 0.17 0.031 WP8
ROOM) (≥ 500 lx) (≥ 0.60)
Perpendicular illuminance (adaptive)
Height: 0.800 m, Wall zone: 0.000 m

26
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 1 (Light scene 1)


Summary

Ground area 9.38 m² Clearance height 3.485 m

Reflection factors Ceiling: 70.0 %, Mounting height 3.383 m


Walls: 13.7 %,
Floor: 80.8 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.000 m

27
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 1 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 28.8 lx ≥ 500 lx WP5

Uo (g1 ) 0.45 ≥ 0.60 WP5

Glare valuation(1) RUG, max 22 ≤ 19

Energy estimation(2) Consumption [20.27 - 32.17] kWh/a max. 350 kWh/a

Room Lighting power density 1.39 W/m² –

4.82 W/m²/100 lx –

(1) Based on a rectangular space of 3.500 m x 2.680 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Zero 7407138 Allright Ceiling 180mm (Aluminum) 21 13.0 W 819 lm 63.0 lm/W

28
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 1


Luminaire layout plan

29
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 1


Luminaire layout plan

Manufacturer Zero P 13.0 W

Article No. 7407138 ΦLuminaire 819 lm

Article name Allright Ceiling


180mm (Aluminum)

Fitting 1x LED 3000K

1 x Zero Allright Ceiling 180mm (Aluminum)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 1.651 m / 1.396 m /
3.383 m 1.651 m 1.396 m 3.383 m 1

X-direction 1 pcs., Centre - centre,


0.450 m

Y-direction 1 pcs., Centre - centre,


0.500 m

Arrangement A1

30
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 1


Luminaire list

Φtotal Ptotal Luminous efficacy


816 lm 13.0 W 62.8 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

1 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm 63.0 lm/W

31
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 1 (Light scene 1)


Calculation objects

32
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 1 (Light scene 1)


Calculation objects

Working planes

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (BEDROOM 1) 28.8 lx 12.9 lx 45.3 lx 0.45 0.28 WP5


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

33
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 1 (Light scene 1)


Working plane (BEDROOM 1)

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (BEDROOM 1) 28.8 lx 12.9 lx 45.3 lx 0.45 0.28 WP5


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

34
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 2 (Light scene 1)


Summary

Ground area 6.93 m² Clearance height 3.485 m

Reflection factors Ceiling: 70.0 %, Mounting height 3.383 m


Walls: 13.7 %,
Floor: 80.8 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.000 m

35
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 2 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 31.0 lx ≥ 500 lx WP6

Uo (g1 ) 0.45 ≥ 0.60 WP6

Glare valuation(1) RUG, max 22 ≤ 19

Energy estimation(2) Consumption [20.27 - 32.17] kWh/a max. 250 kWh/a

Room Lighting power density 1.88 W/m² –

6.06 W/m²/100 lx –

(1) Based on a rectangular space of 3.500 m x 1.981 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Zero 7407138 Allright Ceiling 180mm (Aluminum) 21 13.0 W 819 lm 63.0 lm/W

36
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 2


Luminaire layout plan

37
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 2


Luminaire layout plan

Manufacturer Zero P 13.0 W

Article No. 7407138 ΦLuminaire 819 lm

Article name Allright Ceiling


180mm (Aluminum)

Fitting 1x LED 3000K

1 x Zero Allright Ceiling 180mm (Aluminum)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 1.714 m / 0.966 m /
3.383 m 1.714 m 0.966 m 3.383 m 1

X-direction 1 pcs., Centre - centre,


0.450 m

Y-direction 1 pcs., Centre - centre,


0.500 m

Arrangement A1

38
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 2


Luminaire list

Φtotal Ptotal Luminous efficacy


816 lm 13.0 W 62.8 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

1 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm 63.0 lm/W

39
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 2 (Light scene 1)


Calculation objects

40
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 2 (Light scene 1)


Calculation objects

Working planes

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (BEDROOM 2) 31.0 lx 14.1 lx 45.0 lx 0.45 0.31 WP6


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

41
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 2 (Light scene 1)


Working plane (BEDROOM 2)

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (BEDROOM 2) 31.0 lx 14.1 lx 45.0 lx 0.45 0.31 WP6


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

42
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 3 (Light scene 1)


Summary

Ground area 7.03 m² Clearance height 3.061 m – 3.205 m

Reflection factors Ceiling: 70.0 %, Mounting height 3.100 m


Walls: 13.7 %,
Floor: 80.8 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.000 m

43
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 3 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 36.4 lx ≥ 500 lx WP7

Uo (g1 ) 0.50 ≥ 0.60 WP7

Glare valuation(1) RUG, max 18 ≤ 19

Energy estimation(2) Consumption 42.1 kWh/a max. 250 kWh/a

Room Lighting power density 2.42 W/m² –

6.64 W/m²/100 lx –

(1) Based on a rectangular space of 3.300 m x 2.130 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Zero 8081101 XM Ceiling (White) 17 17.0 W 1065 lm 62.7 lm/W

44
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 3


Luminaire layout plan

45
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 3


Luminaire layout plan

Manufacturer Zero P 17.0 W

Article No. 8081101 ΦLuminaire 1065 lm

Article name XM Ceiling (White)

Fitting 1x LED 3000K

Individual luminaires

X Y Mounting Luminaire
height

1.566 m 1.175 m 3.100 m 1

46
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 3


Luminaire list

Φtotal Ptotal Luminous efficacy


1080 lm 17.0 W 63.5 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

1 Zero 8081101 XM Ceiling (White) 17.0 W 1065 lm 62.7 lm/W

47
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 3 (Light scene 1)


Calculation objects

48
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 3 (Light scene 1)


Calculation objects

Working planes

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (BEDROOM 3) 36.4 lx 18.2 lx 54.3 lx 0.50 0.34 WP7


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

49
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 3 (Light scene 1)


Working plane (BEDROOM 3)

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (BEDROOM 3) 36.4 lx 18.2 lx 54.3 lx 0.50 0.34 WP7


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

50
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 4 (Light scene 1)


Summary

Ground area 5.06 m² Clearance height 3.205 m

Reflection factors Ceiling: 70.0 %, Mounting height 3.176 m


Walls: 13.7 %,
Floor: 80.8 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.000 m

51
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 4 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 39.6 lx ≥ 500 lx WP2

Uo (g1 ) 0.60 ≥ 0.60 WP2

Glare valuation(1) RUG, max 18 ≤ 19

Energy estimation(2) Consumption [26.51 - 42.08] kWh/a max. 200 kWh/a

Room Lighting power density 3.36 W/m² –

8.47 W/m²/100 lx –

(1) Based on a rectangular space of 2.200 m x 2.300 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Zero 8081101 XM Ceiling (White) 17 17.0 W 1065 lm 62.7 lm/W

52
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 4


Luminaire layout plan

53
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 4


Luminaire layout plan

Manufacturer Zero P 17.0 W

Article No. 8081101 ΦLuminaire 1065 lm

Article name XM Ceiling (White)

Fitting 1x LED 3000K

1 x Zero XM Ceiling (White)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 1.160 m / 1.191 m /
3.176 m 1.160 m 1.191 m 3.176 m 1

X-direction 1 pcs., Centre - centre,


0.772 m

Y-direction 1 pcs., Centre - centre,


0.718 m

Arrangement A1

54
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 4


Luminaire list

Φtotal Ptotal Luminous efficacy


1080 lm 17.0 W 63.5 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

1 Zero 8081101 XM Ceiling (White) 17.0 W 1065 lm 62.7 lm/W

55
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 4 (Light scene 1)


Calculation objects

56
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 4 (Light scene 1)


Calculation objects

Working planes

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (BEDROOM 4) 39.6 lx 23.8 lx 52.4 lx 0.60 0.45 WP2


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

57
Dialux Illumination Project

Building 1 · Storey 1 · BEDROOM 4 (Light scene 1)


Working plane (BEDROOM 4)

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (BEDROOM 4) 39.6 lx 23.8 lx 52.4 lx 0.60 0.45 WP2


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

58
Dialux Illumination Project

Building 1 · Storey 1 · COMFORT ROOM 2 (Light scene 1)


Summary

Ground area 3.36 m² Clearance height 3.243 m

Reflection factors Ceiling: 70.0 %, Mounting height 3.171 m


Walls: 13.7 %,
Floor: 80.8 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.000 m

59
Dialux Illumination Project

Building 1 · Storey 1 · COMFORT ROOM 2 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 71.4 lx ≥ 500 lx WP3

Uo (g1 ) 0.12 ≥ 0.60 WP3

Glare valuation(1) RUG, max 22 ≤ 19

Energy estimation(2) Consumption [40.55 - 64.35] kWh/a max. 150 kWh/a

Room Lighting power density 7.74 W/m² –

10.84 W/m²/100 lx –

(1) Based on a rectangular space of 3.170 m x 1.060 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

2 Zero 7407138 Allright Ceiling 180mm (Aluminum) 21 13.0 W 819 lm 63.0 lm/W

60
Dialux Illumination Project

Building 1 · Storey 1 · COMFORT ROOM 2


Luminaire layout plan

61
Dialux Illumination Project

Building 1 · Storey 1 · COMFORT ROOM 2


Luminaire layout plan

Manufacturer Zero P 13.0 W

Article No. 7407138 ΦLuminaire 819 lm

Article name Allright Ceiling


180mm (Aluminum)

Fitting 1x LED 3000K

2 x Zero Allright Ceiling 180mm (Aluminum)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 0.829 m / 0.548 m /
3.171 m 0.829 m 0.548 m 3.171 m 1

X-direction 2 pcs., Centre - centre, 2.344 m 0.548 m 3.171 m 2


1.515 m

Y-direction 1 pcs., Centre - centre,


0.880 m

Arrangement A1

62
Dialux Illumination Project

Building 1 · Storey 1 · COMFORT ROOM 2


Luminaire list

Φtotal Ptotal Luminous efficacy


1632 lm 26.0 W 62.8 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

2 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm 63.0 lm/W

63
Dialux Illumination Project

Building 1 · Storey 1 · COMFORT ROOM 2 (Light scene 1)


Calculation objects

64
Dialux Illumination Project

Building 1 · Storey 1 · COMFORT ROOM 2 (Light scene 1)


Calculation objects

Working planes

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (COMFORT ROOM 2) 71.4 lx 8.50 lx 86.5 lx 0.12 0.098 WP3
Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

65
Dialux Illumination Project

Building 1 · Storey 1 · COMFORT ROOM 2 (Light scene 1)


Working plane (COMFORT ROOM 2)

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (COMFORT ROOM 2) 71.4 lx 8.50 lx 86.5 lx 0.12 0.098 WP3
Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

66
Dialux Illumination Project

Building 1 · Storey 1 · CR 1 (Light scene 1)


Summary

Ground area 2.36 m² Clearance height 2.989 m

Reflection factors Ceiling: 70.0 %, Mounting height 2.951 m


Walls: 13.7 %,
Floor: 80.8 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.000 m

67
Dialux Illumination Project

Building 1 · Storey 1 · CR 1 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 57.3 lx ≥ 500 lx WP1

Uo (g1 ) 0.74 ≥ 0.60 WP1

Glare valuation(1) RUG, max 22 ≤ 19

Energy estimation(2) Consumption [20.27 - 32.17] kWh/a max. 100 kWh/a

Room Lighting power density 5.51 W/m² –

9.61 W/m²/100 lx –

(1) Based on a rectangular space of 1.650 m x 1.430 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Zero 7407138 Allright Ceiling 180mm (Aluminum) 21 13.0 W 819 lm 63.0 lm/W

68
Dialux Illumination Project

Building 1 · Storey 1 · CR 1
Luminaire layout plan

69
Dialux Illumination Project

Building 1 · Storey 1 · CR 1
Luminaire layout plan

Manufacturer Zero P 13.0 W

Article No. 7407138 ΦLuminaire 819 lm

Article name Allright Ceiling


180mm (Aluminum)

Fitting 1x LED 3000K

1 x Zero Allright Ceiling 180mm (Aluminum)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 0.828 m / 0.717 m /
2.951 m 0.828 m 0.717 m 2.951 m 1

X-direction 1 pcs., Centre - centre,


0.380 m

Y-direction 1 pcs., Centre - centre,


0.420 m

Arrangement A1

70
Dialux Illumination Project

Building 1 · Storey 1 · CR 1
Luminaire list

Φtotal Ptotal Luminous efficacy


816 lm 13.0 W 62.8 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

1 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm 63.0 lm/W

71
Dialux Illumination Project

Building 1 · Storey 1 · CR 1 (Light scene 1)


Calculation objects

72
Dialux Illumination Project

Building 1 · Storey 1 · CR 1 (Light scene 1)


Calculation objects

Working planes

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (CR 1) 57.3 lx 42.2 lx 68.6 lx 0.74 0.62 WP1


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

73
Dialux Illumination Project

Building 1 · Storey 1 · CR 1 (Light scene 1)


Working plane (CR 1)

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (CR 1) 57.3 lx 42.2 lx 68.6 lx 0.74 0.62 WP1


Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

74
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM (Light scene 1)


Summary

Ground area 64.59 m² Clearance height 3.329 m

Reflection factors Ceiling: 70.0 %, Mounting height 1.700 m – 3.241 m


Walls: 13.7 %,
Floor: 80.8 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.000 m

75
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 88.1 lx ≥ 500 lx WP8

Uo (g1 ) 0.17 ≥ 0.60 WP8

Glare valuation(1) RUG, max 28 ≤ 19

Energy estimation(2) Consumption [451.56 - 598.95] kWh/a max. 2300 kWh/a

Room Lighting power density 3.75 W/m² –

4.25 W/m²/100 lx –

(1) Based on a rectangular space of 9.201 m x 11.050 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

9 Zero 7407138 Allright Ceiling 180mm (Aluminum) 25 13.0 W 819 lm 63.0 lm/W

1 Zero 7407398 Allright Ceiling 400mm (Dark Grey) 21 26.0 W 1884 lm 72.5 lm/W

2 Zero 7421398 Allright Wall 365mm (Dark Grey) – 11.0 W 510 lm 46.4 lm/W

1 Zero 8081101 XM Ceiling (White) 23 17.0 W 1065 lm 62.7 lm/W

2 Zero 8102106 Lens Pendant 180mm (Black) 25 9.0 W 475 lm 52.8 lm/W

1 Zero 8187341 Fisherman Pendant 650mm (Orange) 28 42.0 W 1838 lm 43.8 lm/W

76
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM


Luminaire layout plan

77
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM


Luminaire layout plan

Manufacturer Zero P 13.0 W

Article No. 7407138 ΦLuminaire 819 lm

Article name Allright Ceiling


180mm (Aluminum)

Fitting 1x LED 3000K

1 x Zero Allright Ceiling 180mm (Aluminum)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 2.468 m / 6.814 m /
2.952 m 2.468 m 6.814 m 2.952 m 9

X-direction 1 pcs., Centre - centre,


0.530 m

Y-direction 1 pcs., Centre - centre,


0.560 m

Arrangement A2

4 x Zero Allright Ceiling 180mm (Aluminum)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 6.020 m / 4.675 m /
3.159 m 6.020 m 9.025 m 3.159 m 5

X-direction 2 pcs., Centre - centre, 10.870 m 9.025 m 3.159 m 6


Distances not equal
6.020 m 4.675 m 3.159 m 7

10.870 m 4.675 m 3.159 m 8

78
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM


Luminaire layout plan

Y-direction 2 pcs., Centre - centre,


Distances not equal

Arrangement A3

4 x Zero Allright Ceiling 180mm (Aluminum)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 0.332 m / 1.099 m /
2.859 m 0.332 m 5.299 m 2.859 m 11

X-direction 2 pcs., Centre - centre, 4.478 m 5.299 m 3.038 m 12


Distances not equal
0.332 m 1.099 m 2.859 m 13

Y-direction 2 pcs., Centre - centre, 4.478 m 1.099 m 3.038 m 14


Distances not equal

Arrangement A6

79
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM


Luminaire layout plan

Manufacturer Zero P 26.0 W

Article No. 7407398 ΦLuminaire 1884 lm

Article name Allright Ceiling


400mm (Dark Grey)

Fitting 1x LED 3000K

1 x Zero Allright Ceiling 400mm (Dark Grey)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 8.342 m / 6.941 m /
3.241 m 8.342 m 6.941 m 3.241 m 4

X-direction 1 pcs., Centre - centre,


0.750 m

Y-direction 1 pcs., Centre - centre,


0.800 m

Arrangement A5

80
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM


Luminaire layout plan

Manufacturer Zero P 11.0 W

Article No. 7421398 ΦLuminaire 510 lm

Article name Allright Wall 365mm


(Dark Grey)

Fitting 1x LED 3000K

1 x Zero Allright Wall 365mm (Dark Grey)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 8.272 m / 2.883 m /
1.796 m 8.272 m 2.883 m 1.796 m 15

X-direction 1 pcs., Centre - centre,


Distances not equal

Y-direction 1 pcs., Centre - centre,


Distances not equal

Arrangement A8

1 x Zero Allright Wall 365mm (Dark Grey)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 8.272 m / 0.736 m /
1.796 m 8.272 m 0.736 m 1.796 m 16

X-direction 1 pcs., Centre - centre,


Distances not equal

81
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM


Luminaire layout plan

Y-direction 1 pcs., Centre - centre,


Distances not equal

Arrangement A9

82
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM


Luminaire layout plan

Manufacturer Zero P 17.0 W

Article No. 8081101 ΦLuminaire 1065 lm

Article name XM Ceiling (White)

Fitting 1x LED 3000K

1 x Zero XM Ceiling (White)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 4.389 m / 7.409 m /
3.029 m 4.389 m 7.409 m 3.029 m 3

X-direction 1 pcs., Centre - centre,


0.800 m

Y-direction 1 pcs., Centre - centre,


0.750 m

Arrangement A4

83
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM


Luminaire layout plan

Manufacturer Zero P 9.0 W

Article No. 8102106 ΦLuminaire 475 lm

Article name Lens Pendant 180mm


(Black)

Fitting 1x LED 3000K

2 x Zero Lens Pendant 180mm (Black)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 5.280 m / 7.941 m /
1.700 m 5.280 m 8.541 m 1.700 m 1

X-direction 1 pcs., Centre - centre, 5.280 m 7.941 m 1.700 m 2


0.550 m

Y-direction 2 pcs., Centre - centre,


0.600 m

Arrangement A1

84
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM


Luminaire layout plan

Manufacturer Zero P 42.0 W

Article No. 8187341 ΦLuminaire 1838 lm

Article name Fisherman Pendant


650mm (Orange)

Fitting 1x TC-TELI 42W/830

1 x Zero Fisherman Pendant 650mm (Orange)

Type Field Arrangement X Y Mounting Luminaire


height
1st luminaire (X/Y/Z) 2.350 m / 3.391 m /
2.755 m 2.350 m 3.391 m 2.755 m 10

X-direction 1 pcs., Centre - centre,


1.100 m

Y-direction 1 pcs., Centre - centre,


1.250 m

Arrangement A7

85
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM


Luminaire list

Φtotal Ptotal Luminous efficacy


14167 lm 242.0 W 58.5 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

9 Zero 7407138 Allright Ceiling 180mm (Aluminum) 13.0 W 819 lm 63.0 lm/W

1 Zero 7407398 Allright Ceiling 400mm (Dark Grey) 26.0 W 1884 lm 72.5 lm/W

2 Zero 7421398 Allright Wall 365mm (Dark Grey) 11.0 W 510 lm 46.4 lm/W

1 Zero 8081101 XM Ceiling (White) 17.0 W 1065 lm 62.7 lm/W

2 Zero 8102106 Lens Pendant 180mm (Black) 9.0 W 475 lm 52.8 lm/W

1 Zero 8187341 Fisherman Pendant 650mm (Orange) 42.0 W 1838 lm 43.8 lm/W

86
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM (Light scene 1)


Calculation objects

87
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM (Light scene 1)


Calculation objects

Working planes

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (LAUNDY, HALLWAY, LIVING, DINING 88.1 lx 14.6 lx 474 lx 0.17 0.031 WP8
ROOM) (≥ 500 lx) (≥ 0.60)
Perpendicular illuminance (adaptive)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

88
Dialux Illumination Project

Building 1 · Storey 1 · LAUNDY, HALLWAY, LIVING, DINING ROOM (Light scene 1)


Working plane (LAUNDY, HALLWAY, LIVING, DINING ROOM)

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (LAUNDY, HALLWAY, LIVING, DINING 88.1 lx 14.6 lx 474 lx 0.17 0.031 WP8
ROOM) (≥ 500 lx) (≥ 0.60)
Perpendicular illuminance (adaptive)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

89
Dialux Illumination Project

Building 1 · Storey 1 · MASTER BEDROOM (Light scene 1)


Summary

Ground area 9.81 m² Clearance height 3.396 m

Reflection factors Ceiling: 70.0 %, Mounting height 2.740 m


Walls: 13.7 %,
Floor: 80.8 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.000 m

90
Dialux Illumination Project

Building 1 · Storey 1 · MASTER BEDROOM (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 38.0 lx ≥ 500 lx WP4

Uo (g1 ) 0.37 ≥ 0.60 WP4

Glare valuation(1) RUG, max 18 ≤ 19

Energy estimation(2) Consumption 42.1 kWh/a max. 350 kWh/a

Room Lighting power density 1.73 W/m² –

4.56 W/m²/100 lx –

(1) Based on a rectangular space of 3.430 m x 2.860 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Zero 8081101 XM Ceiling (White) 17 17.0 W 1065 lm 62.7 lm/W

91
Dialux Illumination Project

Building 1 · Storey 1 · MASTER BEDROOM


Luminaire layout plan

92
Dialux Illumination Project

Building 1 · Storey 1 · MASTER BEDROOM


Luminaire layout plan

Manufacturer Zero P 17.0 W

Article No. 8081101 ΦLuminaire 1065 lm

Article name XM Ceiling (White)

Fitting 1x LED 3000K

Individual luminaires

X Y Mounting Luminaire
height

1.710 m 1.451 m 2.740 m 1

93
Dialux Illumination Project

Building 1 · Storey 1 · MASTER BEDROOM


Luminaire list

Φtotal Ptotal Luminous efficacy


1080 lm 17.0 W 63.5 lm/W

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

1 Zero 8081101 XM Ceiling (White) 17.0 W 1065 lm 62.7 lm/W

94
Dialux Illumination Project

Building 1 · Storey 1 · MASTER BEDROOM (Light scene 1)


Calculation objects

95
Dialux Illumination Project

Building 1 · Storey 1 · MASTER BEDROOM (Light scene 1)


Calculation objects

Working planes

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (MASTER BEDROOM) 38.0 lx 14.0 lx 72.8 lx 0.37 0.19 WP4
Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

96
Dialux Illumination Project

Building 1 · Storey 1 · MASTER BEDROOM (Light scene 1)


Working plane (MASTER BEDROOM)

Properties Ē E min E max U o (g 1) g2 Index


(Target) (Target)

Working plane (MASTER BEDROOM) 38.0 lx 14.0 lx 72.8 lx 0.37 0.19 WP4
Perpendicular illuminance (adaptive) (≥ 500 lx) (≥ 0.60)
Height: 0.800 m, Wall zone: 0.000 m

Utilisation profile: DIALux presetting (5.26.2 Standard (office))

97
Dialux Illumination Project

Glossary

A Formula symbol for a surface in the geometry

Background area The background area borders the direct ambient area according to DIN EN 12464-1 and
reaches up to the borders of the room. In larger rooms, the background area is at least
3 m wide. It is located horizontally at floor level.

CCT (Engl. correlated colour temperature)


Body temperature of a thermal radiator which serves to describe its light colour. Unit:
Kelvin [K]. The lesser the numerical value the redder; the greater the numerical value the
bluer the light colour. The colour temperature of gas-discharge lamps and semi-
conductors are termed "correlated colour temperature" in contrast to the colour
temperature of thermal radiators.

Allocation of the light colours to the colour temperature ranges acc. to EN 12464-1:

Light colour - colour temperature [K]


warm white (ww) < 3,300 K
neutral white (nw) ≥ 3,300 – 5,300 K
daylight white (dw) > 5,300 K

Clearance height The designation for the distance between upper edge of the floor and bottom edge of
the ceiling (in the completely furnished status of room).

Control group A group of luminaires that are dimmed and controlled together. For each lighting scene,
a control group provides its own dimming value. All luminaires within a control group
share this dimming value. The control groups with their luminaires are automatically
determined by DIALux on the basis of the created light scenes and their luminaire
groups.

CRI (Engl. colour rendering index)


Designation for the colour rendering index of a luminaire or a lamp acc. to DIN 6169:
1976 or CIE 13.3: 1995.

The general colour rendering index Ra (or CRI) is a dimensionless figure that describes
the quality of a white light source in regards to its similarity with the remission spectra of
defined 8 test colours (see DIN 6169 or CIE 1974) to a reference light source.

98
Dialux Illumination Project

Glossary

Daylight autonomy Describes what percentage of the daily working time the required illuminance is met by
daylight. The nominal illuminance is used from the room profile, unlike described in EN
17037. The calculation is not done in the centre of the room but at the placed sensor
measuring point. A room is considered sufficiently supplied with daylight if it achieves at
least 50% daylight autonomy.

Daylight factor Ratio of the illuminance achieved solely by daylight incidence at a point in the inside to
the horizontal illuminance in the outer area under an unobstructed sky.

Formula symbol: D (Engl. daylight factor)


Unit: %

Daylight quotient effective area A calculation surface within which the daylight quotient is calculated.

Energy evaluation Based on an hourly calculation procedure for daylight in indoor spaces, considering the
project geometry and any existing daylight control systems. Orientation and location of
the project are also considered. The calculation uses the specified system power of the
luminaires to determine the energy demand. A linear relationship between power and
luminous flux in the dimmed state is assumed for daylight-controlled luminaires. Times
of use and nominal illuminance are determined from the usage profiles of the spaces.
Switched-on luminaires that are explicitly excluded from control also consider the
specified times-of-use. The daylight control systems use a simplified control logic that
closes them at an outdoor horizontal illuminance of 27,500lx.

The calendar year 2022 is used as a reference only. It is not a simulation of this year. The
reference year is only used to assign the days of the week to the calculated results. The
changeover to summer time is not considered. The reference sky type used is the
average sky described in CIE 110 without direct sunlight.

The method was developed together with the Fraunhofer Institute for Building Physics
and is available for review by the Joint Working Group 1 ISO TC 274 as an extension of
the previous annual regression-based method.

Eta (η) (light output ratio)


The light output ratio describes what percentage of the luminous flux of a free radiating
lamp (or LED module) is emitted by the luminaire when installed.

Unit: %

99
Dialux Illumination Project

Glossary

g1 Often also Uo (Engl. overall uniformity)


Designates the overall uniformity of the illuminance on a surface. It is the quotient from
Emin to Ē and is required, for instance, in standards for illumination of workstations.

g2 Actually it designates the "non- uniformity" of the illuminance on a surface. It is the


quotient of Emin to Emax and is generally only relevant for certifying the emergency
lighting acc. to EN 1838.

Illuminance Describes the ratio of the luminous flux that strikes a certain surface to the size of this
surface (lm/m² = lx). The illuminance is not tied to an object surface. It can be
determined anywhere in space (inside or outside). The illuminance is not a product
feature because it is a recipient value. Luxometers are used for measuring.

Unit: Lux
Abbreviation: lx
Formula symbol: E

Illuminance, adaptive For the determining of the middle adaptive illuminance on a surface, this is rastered
"adaptively". In the area of large illuminance differences within the surface, the raster is
subdivided finer; within lesser differences, a rougher classification is made.

Illuminance, horizontal Illuminance that is calculated or measured on a horizontal (level) surface (this can be for
example a table top or the floor). The horizontal illuminance is usually identified by the
formula letter Eh .

Illuminance, perpendicular Illuminance that is calculated or measured plumb-vertical to a surface. This needs to be
taken into account for tilted surfaces. If the surface is horizontal or vertical, then there is
no difference between the perpendicular and the horizontal or vertical illuminance.

Illuminance, vertical Illuminance that is calculated or measured on a vertical surface (this can be for example
the front of some shelves). The vertical illuminance is usually identified by the formula
letter Ev.

LENI (Engl. lighting energy numeric indicator)


Lighting energy numeric indicator acc. to EN 15193

Unit: kWh/(m² * a)

100
Dialux Illumination Project

Glossary

LLMF (Engl. lamp lumen maintenance factor)/acc. to CIE 97: 2005


Lamp flux maintenance factor that takes the luminous flux reduction into account of a
luminaire or an LED module in the course of the operating time. The lamp flux
maintenance factor is specified as a decimal digit and can have a maximum value of 1
(no luminous flux reduction existing).

LMF (Engl. luminaire maintenance factor)/acc. to CIE 97: 2005


Luminaire maintenance factor that takes the soiling into account of the luminaire in the
course of the operating time. The luminaire maintenance factor is specified as a decimal
digit and can have a maximum value of 1 (no soiling existing).

LSF (Engl. lamp survival factor)/acc. to CIE 97: 2005


Lamp survival factor that takes the total failure into account of a luminaire in the course
of the operating time. The lamp survival factor is specified as a decimal digit and can
have a maximum value of 1 (no failures existing within the time concerned or prompt
replacement after the failure).

Luminance Dimension for the "brightness impression" that the human eye has of a surface. The
surface itself can emit light thereby or light striking it can be reflected (emitter value). It is
the only photometric value that the human eye can perceive.

Unit: Candela per square metre


Abbreviation: cd/m²
Formula symbol: L

Luminous efficacy Ratio of the emitted luminous flux Φ [lm] to the absorbed electrical power P [ W] Unit:
lm/W.

This ratio can be formed for the lamp or LED module (lamp or module light output), the
lamp or module with control gear (system light output) and the complete luminaire
(luminaire light output).

Luminous flux Dimension for the total light output that is emitted from one light source in all directions.
It is thus an "emitter value" that specifies the entire emitting output. The luminous flux of
a light source can only be determined in a laboratory. A difference is made between the
lamp or LED module luminous flux and the luminaire luminous flux.

Unit: Lumen
Abbreviation: lm
Formula symbol: Φ

101
Dialux Illumination Project

Glossary

Luminous intensity Describes the intensity of the light in a certain direction (emitter value). The luminous
intensity is a matter of the luminous flux Φ that is emitted in a certain spherical angle Ω.
The radiation characteristics of a light source are presented graphically in a light
distribution curve (LDC). The luminous intensity is an SI base unit.

Unit: Candela
Abbreviation: cd
Formula symbol: I

Maintenance factor See MF

MF (Engl. maintenance factor)/acc. to CIE 97: 2005


Maintenance factor as decimal number between 0 and 1 that describes the ratio of the
new value of a photometric planning parameter (e.g. of the illuminance) to a
maintenance value after a certain time. The maintenance factor takes into account the
soiling of luminaires and rooms as well as the luminous flux reduction and the failure of
light sources.
The maintenance factor is taken into account either overall or determined in detail acc.
to CIE 97: 2005 by the formula RMF x LMF x LLMF x LSF.

P (Engl. power)
Electric power consumption

Unit: watt
Abbreviation: W

R(UG) max Measure of the psychological glare in indoor spaces.


In addition to the luminance of luminaires, the level of the R(UG) value also depends on
the observer position, the viewing direction and the ambient luminance. The calculation
is made according to the table method, see CIE 117. Among other things, EN 12464-
1:2021 specifies maximum permissible R( UG)- values R(UGL) for various indoor workplaces.

Reflection factor The reflection factor of a surface describes how much of the striking light is reflected
back. The reflection factor is defined by the colour of the surface.

102
Dialux Illumination Project

Glossary

RMF (Engl. room maintenance factor)/acc. to CIE 97: 2005


Room maintenance factor that takes the soiling into account of the space encompassing
surfaces in the course of the operating time. The room maintenance factor is specified
as a decimal digit and can have a maximum value of 1 (no soiling existing).

Surrounding area The ambient area directly borders the area of the visual task and should be planned with
a width of at least 0.5 m according to DIN EN 12464-1. It is at the same height as the
area of the visual task.

UGR (max) (unified glare rating)


Measure for the psychological glare effect in interiors.
In addition to luminaire luminance, the UGR value also depends on the position of the
observer, the viewing direction and the ambient luminance. Among other things, EN
12464- 1 specifies maximum permissible UGR values for various indoor workplaces.

UGR observer Calculation point in the room, for the DIALux the UGR value is determined. The location
and height of the calculation point should correspond to the typical observer position
(position and eye level of the user).

Visual task area The area that is needed for carrying out the visual task in accordance with DIN EN 12464
-1. The height corresponds with the height at which the visual task is executed.

Wall zone Circumferential area between working plane and walls which is not taken into account
for the calculation.

Working plane Virtual measuring or calculation surface at the height of the visual task that generally
follows the room geometry. The working plane may also feature a wall zone.

103