REM.S.RA...
TYPE ELECTRONIC REGULATORS
                                                      SINGLE SOLENOID PROPORTIONAL CONTROL VALVES
                                                      Supply voltage (stabilized)                                                12 VDC ÷ 28 VDC
                                                      Supply voltage (Maximum)                                                               30 VDC
                                                      Max. power                                                                                 40W
                                                      Maximum output current                                                                    2.8 A
                                                      External pontetiometer supply (output)                                       +5V / I max 10 mA
                                                      Reference (input)                        0V ÷ +2V       0V ÷ +5V     0V ÷ +10V 0 ÷ 20 mA
                                                      Polarization current adjustment (I. min)                                          0 ÷ 50% Imax
                                                      Ramp time adjustment                                                                0 ÷ 10 sec
                                                      Output signal test point (Valve Current)                              1 Volt = 1 Ampere ±5%
                                                      Ambient operating temperature                                                       0 ÷ +70°C
                                                      Weight                                                                                 0,15 Kg
                     REM.S.RA...
                                                      The electronic control card type REM.S.RA has been designed to drive the “XD.*.A, XDP.3.A,
    CALIBRATION PROCEDURE            CH. IX PAGE 3
                                                      XP.3, XQ.3, XQP.*. and CXQ.3” series ARON single solenoid proportional valves without
    OVERALL DIMENSIONS               CH. IX PAGE 6    integral position transducer. The control card is enclosed in an “OCTAL” type housing, a typical
    MOUNTING BASES                   CH. IX PAGE 6    relay mounting standard. The output stage operates on the pulse width modulation principle
                                                      (P.W.M.) and is provided with current feedback in order to obtain a solenoid output current
                                                      proportional to the reference input signal. Output short circuit and supply polarity inversion
                                                      protection is provided.
                                                      Gain, minimum current and rise and fall ramp time adjustments are possible through the
                                                      corresponding front panel trimming potentiometers, while the output current to the solenoid
           ORDERING CODE                              can be measured via the Valve Current test points, and the ramp operation can be excluded.
                                                      Pay attention please: electronic regulators must be used in dampness and water
     REM        Miniaturized electronic               protected places.
                regulator in Octal
                type container                                                                        ADJUSTMENT      PANEL
      S         Single solenoid
                                                                                    Supply                           12VDC ÷ 28VDC (green led)
     RA         Asymmetrical ramp                                                   Overload                Protection against overload (red led)
                                                                                    Ramp off                                     Ramp off (red led)
                                                                                    Output                 Output (current at solenoid, yellow led)
       *        Maximum output                                                      I. min.                          Minimum current adjustment
                current I MAX. (A)                                                  Gain                                  Ramp down adjustment
                X = 0.88 A                                                          Ramp up                             Rump up adjustment time
                Y = 1.76 A                                                          Ramp down                        Rump down adjustment time
                Z = 2.8 A                                                           Valve Current          Current test point at solenoid (1V =1A)
       *        Input
                reference (V)                         If any field is missing from the ordering code the standard setting is as follows:
                2 = 0÷ + 2 V                                                 - Dither 100Hz
                                                                             - Imin. = continuous
                5 = 0÷ + 5 V
                                                                             - Input ref. = 0÷5V
                0 = 0÷ + 10 V                                                - Imax. = 0.8A
                A = 0 ÷ 20 mA
                                                              ELECTRICAL CIRCUIT AND CONNECTIONS
       *        Frequency Dither
                1 = 100 Hz (standard)                   Sup (2-7)                Power supply
                                                        Out (1-4)                Output for external potentiometer
                2 = 330 Hz (for XP.3)
                                                        Ref(3)                   Reference
                                                        SO (5-6)                 Output at solenoid
       *        Minimum initial current                 DR (8)                   Ramp off (contact closed = exclusion)
                G = step (normally for                  Pot                      External reference potentiometer
                                                        CS                       Feedback current
                XD.*. and XDP.3 valves)
                                                        PS                       Final stage
                C = continuous (normally                SC                       Cable screen
                for XP.3, XQ.3, XQP.*.                  VC                       Current measure test point at solenoid
                and CXQ.3 valves)                       PWM                      Pulse width     modulate wave
      00        No variant
9     3         Serial No.
            registered mark for industrial environ-
    ment
           with reference to the electromagnetic
    compatibility.
             European norms:
           - EN50082-2 general safety norm - in-
    dustrial environment
           - EN 50081-1 emission general norm -
    residential environment
    File: EREMS003                                                      IX • 2                                                              03/2000/e
REM.S.RA... TYPE ELECTRONIC REGULATORS
SINGLE SOLENOID PROPORTIONAL CONTROL VALVES
Calibration procedure
Connect the card in the proper way following the previous page diagram but without powering it. Turn completely anticlockwise the 4 trimming
potentiometers and position the reference potentiometer on zero. Before powering the card, ensure that any unforseen hydraulic system
movement cannot cause material damage or injury to people. Power now the card; the green LED should light up.
Minimum current or polarization current adjustment
Turn slowly the minimum current trimming potentiometer clockwise (Imin) until an actuator movement can be visually detected. Turn slowly
anticlockwise the potentiometer: the minimum current setting will be adjusted correctly when the actuator movement stops. For the REM model
with minimum initial threshold current, turn the reference potentiometer up to a Vref. of 50 mV.
Maximum current GAIN adjustment
Turn first the ramp time trimming potentiometers clockwise by at least 10 turns, if the system could be damaged by a too fast solenoid operation
(evaluate the application carefully). The maximum actuator speed can now be adjusted. Turn the (reference signal) potentiometer to its maximum
setting and rotate slowly the GAIN trimming potentiometer (GAIN) until the maximum required speed is obtained. The speed can now be varied
by moving the potentiometer. The GAIN setting could change the Imin current setting. For this reason it’s better to recheck the Imin after GAIN setting
Ramp time adjustment
The ramp time is the time taken to pass from the minimum to the maximum current value, and vice versa. It’s adjustable from a minimum of 0s
up to a maximum of 10s (to reach the maximum current value setted). Turning clockwise the trimming potentiometer, the ramp time increases.
Notes:
- The ramp fall time affects the actuator stop position. Moving the reference potentiometer to zero Volt, the actuator goes on moving till the setted
ramp time is elapsed. Therefore it’s necessary to adjust it properly.
- When the overload red LED lights up, it will be necessary to switch off the power to the card, switching it on again after having eliminated the
cause of overload.
DIP switch table
Six miniature switches are mounted internally on one of the REM sides. The REM configuration to suit any particular application can be
implemented by setting these switches, which can be reached through the unit ventilating slots.
PWM frequency (100 to 330 Hz), minimum (continuous or step) current, reference voltage range and maximum current (Imax) can thus be adjusted.
For our proportional valves are recommended the following settings:
C     XD.3.A          DITHER =100Hz               Imax.   = 2.35A   with 9V coil
C     XQ.3            DITHER =100Hz               Imax.   = 2.35A   with 9V coil
C     XQP.3           DITHER =100Hz               Imax.   = 2.33A   with 9V coil
C     CXQ.3           DITHER =100Hz               Imax.   = 2.35A   with 9V coil
G     XD.3.A          DITHER =100Hz               Imax.   = 1.76A   with 12V coil
G     XD.5.A          DITHER =100Hz               Imax.   = 2.5A    with 12V coil
G     XDP.3.A         DITHER =100Hz               Imax.   = 1.76A   with 12V coil
C     XQ.3            DITHER =100Hz               Imax.   = 1.76A   with 12V coil
C     XQP.3           DITHER =100Hz               Imax.   = 1.76A   with 12V coil
C     XQP.5           DITHER =100Hz               Imax.   = 2.5A    with 12V coil
C     XP.3            DITHER =330Hz               Imax.   = 1.25A   with 12V coil
C     CXQ.3           DITHER =100Hz               Imax.   = 1.76A   with 12V coil
G     XD.3.A          DITHER =100Hz               Imax.   = 0.88A   with 24V coil
G     XD.5.A          DITHER =100Hz               Imax.   = 1.25A   with 24V coil
G     XDP.3.A         DITHER =100Hz               Imax.   = 0.88A   with 24V coil
C     XQ.3            DITHER =100Hz               Imax.   = 0.88A   with 24V coil
C     XQP.3           DITHER =100Hz               Imax.   = 0.88A   with 24V coil                         TYPICAL CONNECTIONS
C     XQP.5           DITHER =100Hz               Imax.   = 1.25A   with 24V coil
C     XP.3            DITHER =330Hz               Imax.   = 0.68A   with 24V coil
C     CXQ.3           DITHER =100Hz               Imax.   = 0.88A   with 24V coil
                                                                                                                                                                            9
 Incorrect use of the products described in this catalogue may cause harm to personnel and
equipment. The technical information given for each product in this catalogue may be
subject to variation, and the manufacturer reserves the right to make constructional
modifications without giving prior notice. Each product presented, its data, features and
technical specifications must therefore be examined and checked by members of the                    With external reference         With external reference value
user's staff (possessing suitable technical knowledge) taking into consideration the                  potentiometer bank          generator, e.g. by a PLC or in case of
intended use of product. The user must, in particular, assess the operating conditions of
each product in relation to the application that he intends to use it for, analyzing the data,                                          courrent input reference
features and technical specifications in view of the proposed applications, and ensuring
that, in use in the product, all of the conditions relating to the safety of personnel and         • The connection between REM and the solenoid must be direct
equipment, also in the event of breakdown, are respected.
                                                                                                   • The common one of return to proportional solenoid mustn't be shared
                    ARON SPA - REGGIO EMILIA (ITALIA)
                                                                                                   between other valve connections or electrical equipment worker.
           TEL (+39) 0522 50.58 - FAX (+39) 0522 50.58.56
          E-MAIL: [email protected] - WEB PAGES: WWW.ARON.IT
File: EREMS003                                                                                   IX • 3                                                         03/2000/e