Installation Rules Paper 1 August 2019
Installation Rules Paper 1 August 2019
NON-NATIONAL CERTIFICATE:
ENGINEERING CERTIFICATE OF COMPETENCY
INSTALLATION RULES
(First Paper)
(11040412)
3. Number the answers according to the numbering system used in this question
paper.
4. ALL answers must comply with the relevant codes and/or requirements of the
latest SANS publications and the Occupational Health and Safety Act and
Regulations and must show that the candidate fully understands the context
of the relevant question.
7. The candidates must pass PAPER 1 as well as PAPER 2 with 50% each.
Both examination papers may be written during the same examination period.
Candidates need not pass both examination during the same trimester, but
the second examination must be passed within 12 months of the first,
otherwise both examinations must be rewritten. If a candidate obtains
75 marks or more out of 100 in any one of the examinations, he/she will be
permanently exempted from rewriting that examination and a statement will
be issued to this effect. For accreditation purposes ALL candidates must meet
the requirements prescribed by the Department of Labour.
Copyright reserved
(11040412) -3-
1.2 Fully explain the guidelines of Section 5 of this standard regarding planning
and submission of proposals for cable installations. (7)
[10]
2.3 Earth
Complete the following regulations by filling in the missing parts. Write the answer next
to the question number (3.1–3.5) in the ANSWER BOOK:
3.5 The control of all temporary electrical installations on the construction site is … (2)
[10]
Explain the meaning of each IP rating below regarding the protection of persons
against access to hazardous parts with and meaning for the protection against water.
For example IP33 (3) means tool and (3) means limited spraying. Write the answer
next to the question number (4.1–4.5) in the ANSWER BOOK.
4.1 IP 22
4.2 IP 44
4.3 IP X8
4.4 IP 56
4.5 IP 65
(5 × 2) [10]
6.1 State the requirements regarding notices, labels and rating plates in terms of
the code. (4)
6.2 Give any TWELVE topics regarding notices, labels and rating plates as per
TABLE 4.3. (12 × ½) (6)
[10]
7.2 Give THREE methods of protection that can be applied when SELV or PELV
systems are used as means of protection. (3)
[10]
8.2 Give the conditions regarding installation of equipment in a sauna for zone 1
to zone 4. (6)
8.3 Explain which methods of protection against direct contact are not permitted. (2)
[10]
9.1 Complete the following paragraph by filling in the missing word or words.
Write only the word or words next to the question number (9.1.1–9.1.7) in the
ANSWER BOOK.
9.2 Complete the following statement by writing down the missing parts next to
the question number (9.2) in the ANSWER BOOK:
Applied part: part of medical electrical equipment which in normal use … (3)
[10]
10.1 Indicate whether the following statements are TRUE or FALSE. Choose the
answer and write only 'True' or 'False' next to the question number
(10.1.1–10.1.5) in the ANSWER BOOK.
10.1.2 Subclause 7.12 covers, but is not limited to, static UPS systems
that consist of static inverters with batteries as the standby power
source.
10.2 Where an alternative supply system is intended to operate in parallel with the
main supply or where two or more alternate supply systems may operate in
parallel, circulating harmonic currents shall be limited so that the thermal
rating of conductors is not exceeded.
Give FIVE methods that can be applied to reduce the effects of circulating
harmonic currents. (5)
[10]
TOTAL: 100