PRIMER SN - en
PRIMER SN - en
WHERE TO USE
Primer SN has been specifically formulated to carry out preliminary priming treatments on surfaces before applying
epoxy and polyurethane resin systems from the Mapefloor range, self-levelling cementitious mortars from the
Ultratop/Ultratop Living range and of Ultratop Loft, to protect and coat civil and industrial floors, terrazzo floors and
cementitious substrates in general.
TECHNICAL CHARACTERISTICS
Primer SN is a two-component, fillerized epoxy resin-based primer applied with a roller, metal trowel or smooth rake
according to a formula developed in the MAPEI R&D Laboratories.
Coatings made with Primer SN prevent Radon (radioactive natural gas present in the soil) from penetrating inside
buildings.
Compliant with DIN ISO/TS 11665-13 standards, verified and certified by the IAF accredited laboratory for radionuclide
analysis.
Primer SN may be used as it is or mixed with Quartz 0.5 to improve adhesion of resin coating systems and even out
surfaces.
Thanks to its special formulation, Primer SN is characterised by its ability to penetrate into substrates and may even be
applied on moderately damp surfaces.
RECOMMENDATIONS
· Do not apply Primer SN on substrates with rising damp if they are going to be coated with an epoxy or polyurethane
system.
· Do not dilute Primer SN with solvent or water.
· Do not apply Primer SN on dusty, crumbling or weak substrates.
· Do not apply Primer SN on substrates with oil or grease stains or stains in general.
· Do not apply Primer SN on substrates that have not been prepared according to specification.
· Do not mix partial quantities of the components to avoid mixing errors; the product may not harden correctly.
· Do not expose the mixed product to sources of heat.
· If rooms where the product is being used need to be warmed up do not use heaters that burn hydrocarbons, otherwise
the carbon dioxide and water vapour given off into the air will affect the shine on the finish and ruin its appearance. Use
electric heaters only.
· Protect the product from water for at least 24 hours after application.
· Do not apply the product directly on substrates with moisture content higher than 4% and/or with capillary rising damp
(check by testing it with a sheet of polythene).
· The temperature of the substrate must be at least 3°C higher than the dew-point temperature.
APPLICATION PROCEDURE
Preparation of the substrate
The surface of concrete floors must be preferably dry or slightly damp, clean and sound and have no crumbling or
detached portions. The substrate concrete must have a compressive strength of at least 25 N/mm² and a minimum
tensile strength of 1.5 N/mm². The strength of the substrate must also be suitable for its final use and the types of load to
which it will be subjected.
The level of moisture in the substrate must be a maximum of 4% and there must be no capillary rising damp (check by
testing it with a sheet of polythene).
The surface of the floor must be prepared with a suitable mechanical process (e.g. shot-blasting or grinding with a
diamond disk) to remove all traces of dirt, cement laitance and crumbling or detached portions, and to make the surface
slightly rough and absorbent.
Concrete surfaces impregnated with oil and grease must be thoroughly cleaned with a 10% solution of water and soda or
detersive soap and then rinsed several times with plenty of clean water. Remove any water from the surface and wait until
the level of residual moisture is no higher than 4% before applying Primer SN.
If the oil or grease has penetrated deeper into the substrate, on the other hand, all the affected concrete must be removed
by scarifying. The substrate must then be integrated with Mapefloor EP19, a three-component epoxy mortar.
Before applying Primer SN remove all traces of dust from the surface with a vacuum cleaner.
Application of Primer SN
Apply an even coat of neat Primer SN or mixed with Quartz 0.5 on the substrate after it has been prepared as specified
with a straight trowel or rake. Then broadcast with Quartz 0.5 – according to the kind of system to be realized – to ensure
the next coat of resin adheres perfectly. If Ultratop or Ultratop Living is to be applied, use 1.2 mm quartz sand for the
broadcast.
Make sure there are no open pores in the surface of the substrate, otherwise air bubbles could escape from the substrate
and form pinholes in the coating system to be applied. This is particularly important when applying self-levelling resin or
cementitious systems.
CLEANING TOOLS
Clean tools used to prepare and apply Primer SN immediately after use with ethanol. Once hardened, the product may
only be removed mechanically.
CONSUMPTION
0.3-0.7 kg/m² per coat depending on the characteristics of the substrate such as roughness, absorbency, temperature,
etc.
PACKAGING
5 kg kits: component A = 4 kg;
component B = 1 kg.
20 kg kits: component A = 16 kg;
component B = 4 kg.
STORAGE
24 months in its original sealed packaging, in a dry place at a temperature between +5°C and +30°C. Protect from frost.
PRODUCT IDENTITY
component A component B
The times above are for indication purposes only and are influenced by actual site conditions (e.g. temperature of the
surroundings and substrate, relative humidity of the surrounding air, etc.)
FINAL PERFORMANCE
WARNING
Although the technical details and recommendations contained in this product data sheet correspond to the best of our
knowledge and experience, all the above information must, in every case, be taken as merely indicative and subject to
confirmation after long-term practical application; for this reason, anyone who intends to use the product must ensure
beforehand that it is suitable for the envisaged application. In every case, the user alone is fully responsible for any
consequences deriving from the use of the product.
Please refer to the current version of the Technical Data Sheet, available from our website www.mapei.com
LEGAL NOTICE
The contents of this Technical Data Sheet (“TDS”) may be copied into another project-related document, but the
resulting document shall not supplement or replace requirements per the TDS in force at the time of the MAPEI product
installation.
The most up-to-date TDS can be downloaded from our website www.mapei.com.
ANY ALTERATION TO THE WORDING OR REQUIREMENTS CONTAINED OR DERIVED FROM THIS TDS EXCLUDES THE
RESPONSIBILITY OF MAPEI.
2901-3-2022-gb
. Any reproduction of texts, photos and illustrations published here is prohibited and subject to .
prosecution