0% found this document useful (0 votes)
78 views4 pages

Data Sheet: Vpu Ac I 4 R 275/25 LCF S

This document provides product information for a VPU AC I 4 R 275/25 LCF S surge protection device. It lists technical specifications including dimensions, weights, temperature ranges, connection data, ratings, standards, and classifications. The device effectively reduces interference from transient surge voltages and provides surge protection for power supply systems according to its voltage and network type classifications.

Uploaded by

asadsaeed726
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views4 pages

Data Sheet: Vpu Ac I 4 R 275/25 LCF S

This document provides product information for a VPU AC I 4 R 275/25 LCF S surge protection device. It lists technical specifications including dimensions, weights, temperature ranges, connection data, ratings, standards, and classifications. The device effectively reduces interference from transient surge voltages and provides surge protection for power supply systems according to its voltage and network type classifications.

Uploaded by

asadsaeed726
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Data sheet

VPU AC I 4 R 275/25 LCF S Weidmüller Interface GmbH & Co. KG


Klingenbergstraße 26
D-32758 Detmold
Germany

www.weidmueller.com

Product image

Abb.ähnlich
Weidmüller VPU I (Type I), VPU II (Type II) and VPU III General ordering data
(Type III) surge protection products effectively reduce
the interference coupling that can occur due to transient Version Surge voltage arrester, Low voltage, Surge
surge voltages, even significantly below the limits protection, Leakage-current-free, with remote
contact, TN-C-S, TN-S
prescribed by insulation co-ordination according to
Order No. 2726790000
EN 60664-3 / DIN VDE 0110-3. This means that the Type VPU AC I 4 R 275/25 LCF S
whole installation is exposed to fewer malfunctions. GTIN (EAN) 4050118802498
The arresters are co-ordinated using technical means. Qty. 1 pc(s).
This means that decoupling between Types I, II and III Replacement parts 2730860000 2855300000

is unnecessary. The arresters are tested according to


product standard IEC 61643-11 / DIN EN 61643-11 and
can be installed in systems according to IEC 61643-12 /
VDE 0675-6-12 and IEC 62305-4 / VDE 0185-4.
This lightning and surge protection device is suited for
installation in power supply systems. Weidmüller offers
different products depending on the particular mains
network type and voltage level. A special Type I and
Type II protective device is even available for photovoltaic
applications.

Creation date March 19, 2024 7:03:44 AM CET

Catalogue status 09.03.2024 / We reserve the right to make technical changes. 1


Data sheet
VPU AC I 4 R 275/25 LCF S Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
D-32758 Detmold
Germany

www.weidmueller.com
Technical data
Dimensions and weights

Depth 91 mm Depth (inches) 3.583 inch


Height 104.5 mm Height (inches) 4.114 inch
Width 72 mm Width (inches) 2.835 inch
Net weight 676 g

Temperatures

Storage temperature -40 °C...85 °C Operating temperature -40 °C...85 °C


Humidity 5 - 95% rel. humidity

Connection data, remote alert

Connection type Cross-section for connected wire, solid


PUSH IN core, max. 1.5 mm²
Cross-section for connected wire, solid Stripping length
core, min. 0.14 mm² 8 mm

General data

Colour Design Installation housing; 4TE,


orange, black Insta IP 20
Operating altitude Optical function display green = OK; red = arrester
≤ 2000 m is defective - replace
Protection degree IP20 in installed state Rail TS 35
Segment Power distribution UL 94 flammability rating V-0
Version Surge protection, Leakage-
current-free, with remote
contact

Insulation coordination acc. to EN 50178

Pollution severity 2 Surge voltage category IV

Rated data IEC / EN

Discharge current Imax (8/20µs) wire-PE 65 kA Discharge current In (8/20µs) wire-PE 25 kA


Energy coordination (≤10 m) Follow-on current extinguishing
Type I, Type II, Type III capability Ifi 50 kA
Frequency range, max. 60 Hz Frequency range, min. 50 Hz
Fuse No Fuse neccessary ≤315 Leakage current at Un
A gL 1 µA
Lightning test current Iimp (10/350 µs) Low voltage network
(L-PE) 25 kA TN-C-S, TN-S
Mains voltage 230 V / 400 V Max. continuous voltage, Uc (AC) 275 V
Note follow current capability No tripping of a 16 A gG Number of poles
fuse up to prospective 50
kAeff 3
PE conductor current IPE 1 µA Protection level Up at IN (L/N-PE) ≤ 1.5 kV
Rated voltage (AC) Requirements category acc. to IEC
230 V 61643-11 Type I, Type II
Requirements class, acc. to EN Response time
61643-11 T1, T2 < 100 ns
Short-circuit current rating ISCCR 50 kA Signalling contact 250 V 1A 1CO
Standards IEC 61643-11, EN Temporary surge voltage (over-voltage) -
61643-11 TOV 442 V
Voltage type AC

Creation date March 19, 2024 7:03:44 AM CET

Catalogue status 09.03.2024 / We reserve the right to make technical changes. 2


Data sheet
VPU AC I 4 R 275/25 LCF S Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
D-32758 Detmold
Germany

www.weidmueller.com
Technical data
Connection data

Stripping length 15 mm Wire connection method Screw connection


Type of connection Screw connection Stripping length, rated connection 15 mm
Tightening torque, min. 2.5 Nm Tightening torque, max. 4.5 Nm
Clamping range, rated connection 16 mm² Clamping range, min. 4 mm²
Clamping range, max. 35 mm² Wire cross-section, solid, min. 2.5 mm²
Wire cross-section, solid, max. Wire connection cross section, finely
35 mm² stranded, min. 2.5 mm²
Wire connection cross section, finely Conductor cross-section, flexible, AEH
stranded, max. 35 mm² (DIN 46228-1), min. 2.5 mm²
Conductor cross-section, flexible, AEH Connection cross-section, stranded, min.
(DIN 46228-1), max. 35 mm² 2.5 mm²
Connection cross-section, stranded,
max. 35 mm²

Guarantee

Time interval 5 years

Classifications

ETIM 6.0 EC000941 ETIM 7.0 EC000941


ETIM 8.0 EC000941 ETIM 9.0 EC000941
ECLASS 9.0 27-13-08-05 ECLASS 9.1 27-13-08-05
ECLASS 10.0 27-13-08-05 ECLASS 11.0 27-13-08-05
ECLASS 12.0 27-17-90-90 ECLASS 13.0 27-17-90-90

Important note

Product information For use in DC applications, please use the fuse of SIBA Type NH2XL aR/aSF DC 1500 V

Approvals

Approvals

ROHS Conform

Downloads

Approval/Certificate/Document of
Conformity EU_Konformitätserklärung / EU_Declaration_of_Conformity
Engineering Data CAD data -- STEP
Tender specification Ausschreibungstext DE
Tenderspecification EN
User Documentation Beipackzettel / Instruction sheet
Catalogues Catalogues in PDF-format

Creation date March 19, 2024 7:03:44 AM CET

Catalogue status 09.03.2024 / We reserve the right to make technical changes. 3


Data sheet
VPU AC I 4 R 275/25 LCF S Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
D-32758 Detmold
Germany

www.weidmueller.com