0% found this document useful (0 votes)
1K views13 pages

8BVP0440HW00.000-1 en V1.8

This document provides information about the 8BVP0440HW00.000-1 ACOPOSmulti power supply module. It can supply up to 44A of power with a wide input voltage range and integrated temperature sensor. It has 2 slots for plug-in modules and can regenerate power back to the mains. Key specifications include power factors up to 30kW, switching frequencies of 5-10kHz, and integrated EMC filtering.

Uploaded by

Dorin Serban
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views13 pages

8BVP0440HW00.000-1 en V1.8

This document provides information about the 8BVP0440HW00.000-1 ACOPOSmulti power supply module. It can supply up to 44A of power with a wide input voltage range and integrated temperature sensor. It has 2 slots for plug-in modules and can regenerate power back to the mains. Key specifications include power factors up to 30kW, switching frequencies of 5-10kHz, and integrated EMC filtering.

Uploaded by

Dorin Serban
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

8BVP0440HW00.

000-1

8BVP0440HW00.000-1

1 General information
• Wide input voltage range
• Capable of power regeneration
• Integrated connection for temperature sensor
• 2 slots for ACOPOSmulti plug-in modules

2 Order data
Model number Short description Figure
Wall mounting
8BVP0440HW00.000-1 ACOPOSmulti power supply module, 44 A, HV, wall mounting
Required accessories
Terminal block sets
8BZVP044000.000-1A Screw clamp set for ACOPOSmulti modules
8BVP0220Hx00 and 8BVP0440Hx00: 1x 8TB2106.2010-00, 1x
8TB2108.2010-00, 1x 8TB2104.204A-00, 1x 8TB4104.202L-10
Optional accessories
Accessory sets
8BXB000.0000-00 ACOPOSmulti accessory set for encoder buffering consists of
the following: 1 lithium battery AA 3.6 V, 1 cover for battery com-
partment
Fan modules
8BXF001.0000-00 ACOPOSmulti fan module, replacement fan for ACOPOSmulti
modules (8BxP/8B0C/8BVI/8BVE/8B0K)
Plug-in modules
8BAC0120.000-1 ACOPOSmulti plug-in module, EnDat 2.1 interface
8BAC0120.001-2 ACOPOSmulti plug-in module, EnDat 2.2 interface
8BAC0121.000-1 ACOPOSmulti plug-in module, HIPERFACE interface
8BAC0122.000-1 ACOPOSmulti plug-in module, resolver interface 10 kHz
8BAC0123.000-1 ACOPOSmulti plug-in module, incremental encoder and SSI ab-
solute encoder interface for RS422 signals
8BAC0123.001-1 ACOPOSmulti plug-in module, incremental encoder interface for
5 V single-ended and 5 V differential signals
8BAC0123.002-1 ACOPOSmulti plug-in module, incremental encoder interface for
24 V single-ended and 24 V differential signals
8BAC0124.000-1 ACOPOSmulti plug-in module, SinCos interface
8BAC0125.000-1 ACOPOSmulti plug-in module, SinCos EnDat 2.1/SSI/BiSS in-
terface
8BAC0130.000-1 ACOPOSmulti plug-in module, 2 digital outputs, 50 mA, max.
62.5 kHz, 2 digital outputs, 500 mA, max. 1.25 kHz, 2 digital
inputs 24 VDC
8BAC0130.001-1 ACOPOSmulti plug-in module, 2 digital outputs, 50 mA, max.
62.5 kHz, 4 digital outputs, 500 mA, max. 1.25 kHz
8BAC0132.000-1 ACOPOSmulti plug-in module, 4 analog inputs ±10 V
8BAC0133.000-1 ACOPOSmulti plug-in module, 3 RS422 outputs for ABR en-
coder emulation, 1 MHz
POWERLINK/Ethernet cables
X20CA0E61.00020 POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.2 m
X20CA0E61.00025 POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.25 m
X20CA0E61.00030 POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.3 m
X20CA0E61.00035 POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.35 m
X20CA0E61.00050 POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.5 m
X20CA0E61.00100 POWERLINK/Ethernet connection cable, RJ45 to RJ45, 1 m
Shield component sets
8SCS002.0000-00 ACOPOSmulti shield component set: 1x clamping plate; 2x
clamps D 4-13.5 mm; 4x screws
8SCS005.0000-00 ACOPOSmulti shield component set: 1x slot cover/shield plate
8SCS007.0000-00 ACOPOSmulti shield component set: 1x shield mounting plate
2x 45°, 4x screws
8SCS008.0000-00 ACOPOSmulti shield component set: 1x shield plate 2x type 0,
1x hose clamp, B 9 mm, D 23-35 mm
8SCS010.0000-00 ACOPOSmulti shield component set: 1x ACOPOSmulti holding
plate SK14-20, 1x shield connection clamp SK20
Terminal blocks

Table 1: 8BVP0440HW00.000-1 - Order data

Data sheet V1.8 1


8BVP0440HW00.000-1
Model number Short description Figure
8TB2104.204A-00 4-pin screw clamp, single row, spacing: 5.08 mm, label 4: T- T
+ F- F+, A keying: 0000
8TB2106.2010-00 6-pin screw clamp, single row, spacing: 5.08 mm, label 1: num-
bered serially
8TB2106.2210-00 Push-in terminal block 6-pin, 1-row, spacing: 5.08 mm, label 1:
numbered consecutively
8TB2108.2010-00 8-pin screw clamp, single row, spacing: 5.08 mm, label 1: num-
bered serially
8TB4104.202L-10 4-pin screw clamp terminal block, 1-row, spacing: 10.16 mm,
label 2: PE L3 L2 L1, coding L: 1010

Table 1: 8BVP0440HW00.000-1 - Order data

3 Technical data
Model number 8BVP0440HW00.000-1
General information
B&R ID code 0xA074
Cooling and mounting method Wall mounting
Slots for plug-in modules 2
Certifications
CE Yes
KC Yes
UL cULus E225616
Power conversion equipment
Mains connection
Network configurations TT, TN-S, TN-C-S 1)
Mains input voltage 3x 220 to 3x 480 VAC ±10%
Frequency 50 / 60 Hz ±4%
Installed load 2) Max. 31.1 kW
Inrush current at 400 VAC Max. 67 A
Switch-on interval 3) >300 s
Max. DC bus capacitance depending on mains volt-
age
230 VAC 17.4 mF
400 VAC 5.8 mF
480 VAC 4 mF
Nominal switching frequency 5 kHz
Possible switching frequencies 4) 5 / 10 kHz
Integrated line filter per EN 61800-3, category C3 5) No
Integrated regeneration choke No
Capable of power regeneration Yes
Power factor correction (PFC) Yes
Variant
L1, L2, L3, PE Male connector
PE M5 threaded bolt
Shield connection 6) Yes
Terminal connection cross section
Flexible and fine-stranded wires
With wire end sleeves 0.5 to 16 mm²
Approbation data
UL/C-UL-US 20 to 6 AWG
CSA 20 to 6 AWG
Terminal cable cross section dimension of shield 23 to 35 mm
connection
DC bus connection
Voltage
Nominal 750 VDC
Continuous power (supply and regeneration) 7) 30 kW
Reduction of continuous power depending on
mains input voltage
Mains input voltage <3x 400 VAC 75 W/V * (400 V - Mains input voltage)
Reduction of continuous power depending on DC
bus voltage (UDC)
UDC <750 VDC P * (1 - UDC/750) 8)
Reduction of continuous power depending on
switching frequency 9)
Switching frequency 5 kHz 1.11 kW/K (starting at 40°C) 10)
Switching frequency 10 kHz 0.35 kW/K (starting at -10°C) 11)
Reduction of continuous power depending on in-
stallation elevation
Starting at 500 m above sea level 3 kW per 1000 m
Peak power (supply and regeneration) 60 kW

Table 2: 8BVP0440HW00.000-1 - Technical data

2 Data sheet V1.8


8BVP0440HW00.000-1
Model number 8BVP0440HW00.000-1
Power dissipation depending on switching frequen-
cy 12)
Switching frequency 5 kHz [0.15*P²+10.5*P+40] W
Switching frequency 10 kHz [0.42*P²+16*P+130] W
DC bus capacitance 825 µF
Protective measures
Overload protection Yes
Short circuit and ground fault protection No
Variant ACOPOSmulti backplane
24 VDC power supply
Input voltage 25 VDC ±1.6%
Input capacitance 4.7 µF
Max. power consumption 25 W + PSLOT1 + PSLOT2 + P24 V Out + PFan8BVF...13)
Variant ACOPOSmulti backplane
24 VDC Out
Quantity 2
Output voltage
DC bus voltage (UDC): 260 to 315 VDC 25 VDC * (UDC / 315)
DC bus voltage (UDC): 315 to 800 VDC 24 VDC ±6%
Fuse protection 250 mA (slow-blow) electronic, automatic reset
Filter fan connection
Output voltage 24 V +5.8% / -0.1%
Continuous current 4.2 A
Max. overcurrent limitation 10 A
Protective measures
Overload protection No
Short-circuit proof Yes
Open circuit monitoring No
Undervoltage monitoring No
Trigger inputs
Quantity 2
Wiring Sink
Electrical isolation
Input - Power supply module Yes
Input - Input Yes
Input voltage
Nominal 24 VDC
Maximum 30 VDC
Switching threshold
Low <5 V
High >15 V
Input current at nominal voltage Approx. 10 mA
Switching delay
Rising edge 52 μs ± 0.5 μs (digitally filtered)
Falling edge 53 μs ± 0.5 μs (digitally filtered)
Modulation compared to ground potential Max. ±38 V
Electrical characteristics
Discharge capacitance 0.9 µF
Operating conditions
Permissible mounting orientations
Hanging vertically Yes
Lying horizontally Yes
Standing horizontally No
Installation elevation above sea level
Nominal 0 to 500 m
Maximum 14) 4000 m
Pollution degree per EN 61800-5-1 2 (non-conductive pollution)
Overvoltage category per EN 61800-5-1 III
Degree of protection per EN 60529 IP20
Environmental conditions
Temperature
Operation
Nominal 5 to 40°C
Maximum 15) 55°C
Storage -25 to 55°C
Transport -25 to 70°C
Relative humidity
Operation 5 to 85%
Storage 5 to 95%
Transport Max. 95% at 40°C

Table 2: 8BVP0440HW00.000-1 - Technical data

Data sheet V1.8 3


8BVP0440HW00.000-1
Model number 8BVP0440HW00.000-1
Mechanical properties
Dimensions 16)
Width 106.5 mm
Height 317 mm
Depth
Wall mounting 263 mm
Weight Approx. 5.5 kg
Module width 2

Table 2: 8BVP0440HW00.000-1 - Technical data


1) TT and TN power systems are commonly referred to as "Delta/Wye with grounded wye neutral" in the USA.
2) The specified value already contains the power dissipation of the associated 8BVF line filter and associated 8BVR regeneration choke.
3) At max. loadable DC bus capacitance.
4) B&R recommends operating the module at its nominal switching frequency. Operating the module at a higher switching frequency for application-specific
reasons results in a reduction in continuous power and higher CPU utilization.
5) Limit values from EN 61800-3 C3 (second environment).
6) Cables do not have to be shielded up to a total length of 3 m between the line filter, regeneration choke and power supply module. Please contact B&R
when using cable lengths >3 m.
7) Valid under the following conditions: 3x 400 VAC mains input voltage, DC bus nominal voltage 750 VDC, 5 kHz switching frequency, 40°C ambient temperature,
installation elevation <500 m above sea level, no derating due to cooling type.
8) P ... Actual continuous power available (value adjusted to the actual environmental conditions)
9) Valid in the following conditions: 750 VDC DC bus voltage. The temperature specifications refer to the ambient temperature.
10) Value for the nominal switching frequency.
11) The module cannot supply the full continuous current at this switching frequency. This unusual value for the ambient temperature, at which derating of the
continuous current must be taken into account, ensures that the derating of the continuous current can be determined in the same manner as at other
switching frequencies.
12) Valid for a mains input voltage of 400 VAC and a DC bus voltage of 750 VDC. P ... Continuous power [kW].
13) PSLOT1 ... Max. power consumption P8BAC [W] of the plug-in module in SLOT1 (see the technical data for the respective plug-in module)
PSLOT2 ... Max. power consumption P8BAC [W] of the plug-in module in SLOT2 (see the technical data for the respective plug-in module).
P24 V Out ... Power [W] that is output to connections X2/+24 V Out 1 and X2/+24 V Out 2 on the module (max. 10 W).
PFan8BVF... ... Power [W] that is output to connections X4A/F- and X4A/F+ on the module (see the technical data for the respective 8BVF... line filter).
14) Continuous operation at an installation elevation of 500 m to 4,000 m above sea level is possible taking the specified reduction of continuous current into
account. Requirements that go beyond this must be arranged with B&R.
15) Continuous operation at an ambient temperature of 40°C to max. 55°C is possible taking the specified reduction of continuous torque into account, but this
results in premature aging of components.
16) These dimensions refer to the actual device dimensions including the respective mounting plate. Make sure to leave additional space above and below the
devices for mounting, connections and air circulation.

4 Data sheet V1.8


8BVP0440HW00.000-1

4 Status indicators
Status indicators are located on the black cover of each module.

Encoder SLOT1 Encoder SLOT2

Status of backup battery


Power supply POWERLINK

Power inverter power system

Figure 1: 8BVP power supply modules - Status indicator groups

4.1 LED status indicators


Status indicator group Label Color Function Description
POWERLINK R/E Green/Red Ready/Error see "POWERLINK - LED status indicators" on page 6
L/D1 Green Link/Data activity on port 1
L/D2 Green Link/Data activity on port 2
Power inverter power system RDY Green Ready see "RDY, RUN, ERR (8BVI, 8BVP, 8B0P) - LED status indica-
RUN Orange Run tors" on page 6
ERR Red Error
Status of backup battery BAT Green/Red Ready/Error see "Backup battery - LED status indicators" on page 7
Power supply 24 V Green 24 V OK 24 V internal system voltage supply is within the
tolerance range
Encoder SLOT1 UP Orange Encoder direction of rotation + The encoder position of the connected encoder is changing in
the positive direction. The faster the encoder position changes,
the brighter the LED is lit.
DN Orange Encoder direction of rotation - The encoder position of the connected encoder is changing in
the negative direction. The faster the encoder position changes,
the brighter the LED is lit.
Encoder SLOT2 UP Orange Encoder direction of rotation + See encoder SLOT1.
DN Orange Encoder direction of rotation -

Table 3: 8BVP power supply modules - LED status indicators

Data sheet V1.8 5


8BVP0440HW00.000-1

4.2 RDY, RUN, ERR (8BVI, 8BVP, 8B0P) - LED status indicators
Label Color Function Description
RDY Green Ready Solid green The module is operational and the power stage can be enabled (operating sys-
tem present and booted, no permanent or temporary errors).
Blinking green 1) The module is not ready for operation.
Examples:
• No signal on one or both enable inputs
• DC bus voltage outside the tolerance range
• Overtemperature on the motor (temperature sensor)
• Motor feedback not connected or defective
• Motor temperature sensor not connected or defective
• Overtemperature on the module (IGBT junction, heat sink, etc.)
• Disturbance on network
RUN Orange Run Solid orange The module's power stage is enabled.
ERR Red Error Solid red 1) There is a permanent error on the module.
Examples:
• Permanent overcurrent
• Invalid data in EPROM
Blinking red • LED status "Status changes when starting up the operating system
loader" on page 7

Table 4: RDY, RUN, ERR (8BVI, 8BVP, 8B0P) - LED status indicators
1) Firmware V2.130 and later.

Information:
The ACOPOSmulti drive system has no way of detecting whether the fans in the fan modules of the
mounting plate or the module-internal fans are actually rotating.

4.3 POWERLINK - LED status indicators


Label Color Function Description
R/E Green/Red Ready/Error LED off The module is not supplied with power or network interface initialization has
failed.
Solid red The POWERLINK node number of the module is 0.
Blinking red/green The client is in an error state (drops out of cyclic operation).
Blinking green The client detects a valid POWERLINK frame on the network.
(1x)
Blinking green Cyclic operation on the network is taking place, but the client itself is not yet a
(2x) participant.
Blinking green Cyclic operation of the client is in preparation.
(3x)
Solid green The client is participating in cyclic operation.
Flickering green The client is not participating in cyclic operation and also does not detect any
other stations on the network participating in cyclic operation.
L/D1 Green Link/Data activity Solid green A physical connection has been established to another station on the network.
Port 1 Blinking green Activity on port 1
L/D2 Green Link/Data activity Solid green A physical connection has been established to another station on the network.
Port 2 Blinking green Activity on port 2

Table 5: POWERLINK - LED status indicators

6 Data sheet V1.8


8BVP0440HW00.000-1

4.4 Backup battery - LED status indicators


Label Color Function Description
BAT Green/Red Ready/Error LED off Possible causes:
• The voltage of the installed backup battery is within the tolerance range,
but an EnDat encoder with backup battery is not connected.
• An EnDat encoder with backup battery is connected and registering "Bat-
tery OK", but the module's firmware version does not support EnDat en-
coders with battery backup.
Solid green An EnDat encoder with battery backup is connected and registering "Battery
OK" (voltage of the installed backup battery is within the tolerance range).
Solid red An EnDat encoder with battery backup is connected and registering "Battery not
OK".
Possible causes:
• Voltage of the installed backup battery outside of tolerance range
• No backup battery installed in module

Table 6: Backup battery - LED status indicators

4.5 Status changes when starting up the operating system loader

The following intervals are used for the LED status indicators:
Block size: 50 ms
Repeats after: 3,000 ms
Status LED Display
1. Boot procedure for base hardware RDY
active RUN
ERR
2. Network configuration active RDY
RUN
ERR
3. Waiting for network telegram RDY
RUN
ERR
4. Network communication active RDY
RUN
ERR
5. ACOPOS operating system being RDY
transferred/burned 1) RUN
ERR

Table 7: Status changes when starting up the operating system loader


1) Firmware V2.140 and later.

Data sheet V1.8 7


8BVP0440HW00.000-1

5 Dimension diagram and installation dimensions

Permitted
mounting orientations
3)

1)

Hanging vertically

Lying horizontally

Impermissible
mounting orientations

Standing horizontally
2)

Hanging horizontally

Figure 2: Dimension diagram and installation dimensions


1) n... Number of width units on the mounting plate
2) For sufficient air circulation, a clearance of at least 60 mm must be provided above the mounting plate and below the module.
To ensure that the fan modules in the mounting plate can be replaced easily, at least 250 mm clearance must be available below the module.
3) nnnn indicates the number of slots (e.g. 0160 refers to 16 slots).

8 Data sheet V1.8


8BVP0440HW00.000-1

6 Wiring
6.1 8BVP0220Hx00.000-1, 8BVP0440Hx00.000-1 - Pinout overview

(=8B0C... / X1: COM (5, 6))


(=8B0C... / X1: CR_OK)
+24 V

0V

POWERLINK

POWERLINK
8 7 6 5 4 3 2 1 6 5 4 3 2 1
Slot 1

Slot 2

+24 V Out 1
+24 V Out 2

Trigger1

T-
Trigger2

T+
COM (8)
COM (5)

COM (4)
COM (1)

COM (5, 6)
COM (5, 6)
CR_OK
CR_OK
X3A X3B

X2
X1
X2
X1

X2
X1
1
X3B 1

X3A

Slot2
Slot1

X4A

X4A X5A
X5A

X4A X5A
PE

ACOPOSmulti
L3
L1
L2

PE
T+
F+

T-
F-

8BVP0220Hx00.000-1
4 3 2 1 4 3 2 1 8BVP0440Hx00.000-1

(=8BVF... / X3:F+) (=8BVR... / W2)

(=8BVF... / X3:F-) (=8BVR... / V2)

(=8BVR... / T+) (=8BVR... / U2)

(=8BVF... / X3:T-)

Figure 3: 8BVP0220Hx00.000-1, 8BVP0440Hx00.000-1 - Pinout overview

6.2 Connector X1 - Pinout


X1 Pin Description Function
1
1 T+ Temperature sensor +
2 T- Temperature sensor -
2
3 COM (5, 6) DC bus ready 0 V
4 COM (5, 6) DC bus ready 0 V
3

4 5 CR_OK DC bus ready 1)


5 6 CR_OK DC bus ready 1)
6

Table 8: Connector X1 - Pinout


1) Output CR_OK is only set if the following condition is met:
The charging relay is closed and the DC bus voltage UDC >270 VDC.

Data sheet V1.8 9


8BVP0440HW00.000-1

Danger!
The connections for the temperature sensors are safely isolated circuits. These connections are there-
fore only permitted to be connected to devices or components that have sufficient isolation per IEC
60364-4-41 or EN 61800-5-1.

6.3 Connector X2 - Pinout


X2 Pin Description Function
1
1 Trigger1 Trigger1
2 COM (1) Trigger 1 0 V
2
3 COM (4) +24 V output 1 0 V
4 +24 V Out 1 +24 V output 1
3

4 5 Trigger2 Trigger2
5 6 COM (5) Trigger 2 0 V
6 7 COM (8) +24 V output 2 0 V
7
8 +24 V Out 2 +24 V output 2
8

Table 9: Connector X2 - Pinout

6.4 Connectors X3A, X3B - Pinout


X3A, X3B Pin Description Function
1 RXD Receive signal
2 RXD\ Receive signal inverted
3 TXD Transmit signal
1
4 Shield Shield
5 Shield Shield
6 TXD\ Transmit signal inverted
7 Shield Shield
8 Shield Shield

Table 10: X3A, X3B connectors - Pinout

6.5 Connector X4A - Pinout


X4A Description Function
T- Power system: Temperature sensor -
T+ Power system: Temperature sensor +
F- Power system: Fan -
F+ Power system: Fan +
F+ F- T+ T-

Table 11: Connector X4A - Pinout

Danger!
The connections for temperature sensor and fan are safely isolated circuits. These connections are
therefore only permitted to be connected to devices or components that have sufficient isolation per
IEC 60364-4-41 or EN 61800-5-1.

Warning!
Temperature sensors are only permitted to be connected to the X4A/T+ and X4A/T- connectors on an
ACOPOSmulti module under the following conditions:
• SLOT1 of the ACOPOSmulti module does not contain an ACOPOSmulti plug-in module to which
a temperature sensor is connected on the T+ and T- connections.
Otherwise, the temperature monitoring functions on the ACOPOSmulti module may become ineffec-
tive, which in extreme cases can cause the hardware (e.g. motors) connected to the ACOPOSmulti
module to be destroyed!

10 Data sheet V1.8


8BVP0440HW00.000-1

6.6 Connector X5A - Pinout


X5A Description Function
PE Power system: Protective ground conductor
L3 Power system: Mains connection L3
L2 Power system: Mains connection L2
L1 Power system: Mains connection L1

L1 L2 L3

Table 12: Connector X5A - Pinout

Danger!
Before switching on the module, it is important to make sure that the housing is properly connected
to ground (PE rail). Ground connections must also be established if the module is connected for test
purposes or only being operated for a short period of time!

6.7 Additional protective ground connection (PE)

The protective ground conductor is secured to the M5 threaded bolt provided for this purpose using a cable lug.
Figure Pin Description Function
--- PE Protective ground conductor

Terminal cross section [mm²] AWG


Cable lug for M5 threaded bolt 0.25 - 16 23 - 5

Table 13: Additional protective ground connection (PE)

Danger!
Before switching on the power supply, it must be ensured that the housing of the 8BVP power supply
module is properly connected to ground potential (PE rail). Ground connections must also be estab-
lished if the 8BVP power supply module is connected for test purposes or only being operated for a
short period of time!

6.8 Input/Output circuit diagram

Figure 4: 8B0C - Enable

Data sheet V1.8 11


8BVP0440HW00.000-1

1K

1K

1K

1K

Figure 5: Trigger inputs

Figure 6: 24 VDC out


8BVP0220Hx00.000-1 ≥ Rev. H0
8BVP0440Hx00.000-1 ≥ Rev. L0
8BVP0880Hx00.00x-1 ≥ Rev. D0
8BVP1650Hx00.000-1 ≥ Rev. C0

Figure 7: 8BVF fan - Control

12 Data sheet V1.8


8BVP0440HW00.000-1
T- T+

Plug-in module
8BAC0120.000-1
8BAC0121.000-1
8BAC0122.000-1
8BAC0123.00x-1
8BAC0124.000-1
+5 V 8BAC0125.000-1

Slot 1
3k X4A
2
ADC T+
1
T-
10k

T- T+

Plug-in module
8BAC0120.000-1
8BAC0121.000-1
8BAC0122.000-1
8BAC0123.00x-1
8BAC0124.000-1
+5 V 8BAC0125.000-1

Slot 2
3k X1
1
ADC T+
2
T-
10k

Figure 8: Temperature sensor

Main relay

8 .. 16E

8 .. 16E

8 .. 16E

Figure 9: Power unit

6.9 POWERLINK node number setting

The POWERLINK node number can be set using the two hexadecimal coded rotary switches located behind the
module's black cover.
Figure Coded rotary POWERLINK node number
switches
1 16s position (high)
2 1s position (low)
A change to the POWERLINK node number only takes effect
the next time the ACOPOSmulti drive system is switched on.

Information:
In principle, node numbers between $01 and $FD are
permitted.
However, node numbers between $F0 and $FD are in-
tended for future system expansions. To ensure com-
patibility, these node numbers should be avoided.
Node numbers $00, $FE and $FF are reserved and are
therefore not permitted to be set.

Cover closed Cover open

Table 14: Setting the POWERLINK node number

Data sheet V1.8 13