Two-Storey Residential Floor Plan

This document contains a structural drawing of a roof beam design for a building. The drawing shows dimensions and materials used for the roof trusses, purlins, collar plates, king posts, and other structural elements. Notes specify that column tie spacing should be closer as indicated in the column schedule. The drawing provides details for the roof truss design and connections.

Uploaded by

raymunddublin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
1K views1 page

Two-Storey Residential Floor Plan

This document contains a structural drawing of a roof beam design for a building. The drawing shows dimensions and materials used for the roof trusses, purlins, collar plates, king posts, and other structural elements. Notes specify that column tie spacing should be closer as indicated in the column schedule. The drawing provides details for the roof truss design and connections.

Uploaded by

raymunddublin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

REPUBLIC OF THE PHILIPPINES

OFFICE OF THE BUILDING


OFFICIAL
ROOF BEAM
0 733
733 0
2400

Y
CAGAYAN DE ORO CITY
3 SETS TIES
DISTRICT/CITY/MUNICIPALITY

SPLICED
SPLICING SHOULD

2850
BE LOCATED AT LAND USE AND ZONING
2050 900 900 900 900 900 900 900 900 2050
1250
6900 6900
1250 MID-HEIGHT OF
13800 COLUMN OR AT
11300 1/3 OF COLUMN
HEIGHT
TRUSS 2 (6 UNITS) LINE AND GRADE

Y
FLOOR LINE
RIDGE ROLL ROOF
2" x 3" x 1.5mm STEEL C-PURLINS FLOOR BEAM ACHITECTURAL
2" x 6" x 1.5mm STEEL TUBE KING POST
2" x 6" x 1.5mm STEEL TUBE
3 SETS TIES

Y
2" x 4" x 1.5mm STEEL TUBE COLLAR PLATE
BOTTOM CHORD
RIB TYPE LONG SPAN ROOFING
STRUCTURAL/CIVIL

2950
733
0 2" x 4" x 1.5mm STEEL TUBE NOTE :
WEB MEMBERS " Y " - CLOSER SPACING
2" x 6" x 1.5mm STEEL TUBE
TOP CHORD
OF COLUMN TIES PER
SET AS SPECIFIED IN
THE COLUMN SCHEDULE LINE AND GRADE

Y
WOOD FASCIA
FLOOR LINE PLUMBING
1/4" THK. MARINE
PLYWOOD RB
RB 13800

Y
TRUSS 2 DETAIL ELECTRICAL

Y
10mm Ø REINFORCEMENT MECHANICAL
10mm Ø TOP AND BOT. REINFORCEMENT
SPACED @ 250mm O.C. B.W.
SPACED @ 250mm O.C. B.W.
100 150

FB FIRE DEPARTMENT
ELEVATION OF TIED COLUMN
LEAN CONCRETE
ELECTRONICS

GEODETIC

SIGNATURE AND SEAL: APPROVED BY: SHEET TITLE: DRAWN BY: SHEET NO:
RGB
DUBLIN
RAYMUND R. DUBLIN SHEET CONTENT:
PROJECT
PROPOSED TWO-STOREY RESIDENTIAL
PRC NO: VALIDITY: BUILDING DATE: 09/30/23
A
IAPOA: O.R. NO: DATE: CADD BY:
FLOOR PLAN RGB
PTR NO: DATE: HAYES ST. CAMAMAN-AN, CAGAYAN DE ORO CITY, JUAN P. DE LA CRUZ JR.
PLACE: TIN NO:
LOCATION
MISAMIS ORIENTAL 9000 OWNER DATE: 09/30/23