0% found this document useful (0 votes)
43 views5 pages

3LD30540TK51 Datasheet en

1) This document provides data and specifications for the Load disconnector 3LD3, Iu 16 A Main switch 3-pole from Siemens. 2) It is rated for 7.5kW at 400V AC-23 and has a central hole mounting with a front plate and rotating black drive of 66 x 66 mm. 3) Key specifications include 16A rated current, IP65 protection class, 0.5W power loss per pole, and 100,000 cycle mechanical life.

Uploaded by

claus.skjoeth
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views5 pages

3LD30540TK51 Datasheet en

1) This document provides data and specifications for the Load disconnector 3LD3, Iu 16 A Main switch 3-pole from Siemens. 2) It is rated for 7.5kW at 400V AC-23 and has a central hole mounting with a front plate and rotating black drive of 66 x 66 mm. 3) Key specifications include 16A rated current, IP65 protection class, 0.5W power loss per pole, and 100,000 cycle mechanical life.

Uploaded by

claus.skjoeth
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Data sheet 3LD3054-0TK51

Load disconnector 3LD3, Iu 16 A Main switch 3-pole Rated operating capacity at


AC-23 A at 400V 7.5kW Front plate mounting Basic switch with Central hole
mounting 22.5mm Rotating drive black 66 x 66 mm

Model
product brand name SENTRON
product designation Switch disconnector
design of the product Main switch
display version for switch position indicator manual operation 1 ON - 0 OFF
type of switch front mounted
design of the actuating element Short rotary knob
color of the actuating element black
design of handle rotary operating mechanism, black
type of the driving mechanism motor drive No
General technical data
number of poles 3
number of poles note 3
mechanical service life (operating cycles) typical 100 000
electrical endurance (operating cycles)
● at AC-23 A at 690 V 6 000
operating frequency maximum 50 1/h
degree of pollution 3
Voltage
insulation voltage rated value 690 V
surge voltage resistance rated value 6 kV
operating voltage
● at AC rated value 690 V
operating frequency rated value
● minimum 50 Hz
● maximum 60 Hz
Protection class
protection class IP IP65
degree of protection NEMA rating 1, 3R, 4X, 12
protection class IP on the front IP65
Dissipation
power loss [W] for rated value of the current at AC in hot 0.5 W
operating state per pole
Main circuit
operational current
● at AC-21 at 690 V rated value 16 A
● at AC-21 A at 240 V rated value 16 A
● at AC-21 A at 400 V rated value 16 A
● at AC-21 A at 440 V rated value 16 A
● at AC-23 A at 400 V rated value 16 A

3LD30540TK51 Subject to change without notice


3/21/2024
Page 1/5 © Copyright Siemens
operating power
● at AC-23 A at 240 V rated value 3 kW
● at AC-23 A at 400 V rated value 8 kW
● at AC-23 A at 440 V rated value 7.5 kW
● at AC-23 A at 690 V rated value 8 kW
● at AC-3 at 240 V rated value 3 kW
● at AC-3 at 400 V rated value 6 kW
● at AC-3 at 690 V rated value 5.5 kW
Auxiliary circuit
number of CO contacts for auxiliary contacts 0
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
operating voltage of auxiliary contacts at AC maximum 500 V
continuous current of the auxiliary contact rated value 10 A
Suitability
suitability for use
● main switch Yes
● switch disconnector Yes
● EMERGENCY OFF switch No
● safety switch Yes
● maintenance/repair switch Yes
Product details
special product feature Can be locked in zero position
product feature can be locked into OFF position Yes
accessories
product extension optional
● motor drive No
● voltage trigger No
number of connectable NC contacts for auxiliary contacts 2
attachable maximum
number of connectable NO contacts for auxiliary contacts 4
attachable maximum
number of connectable CO contacts for auxiliary contacts 0
attachable maximum
number of bracket locks maximum 3
hasp thickness of the bracket locks 4 ... 8 mm
Short circuit
conditional short-circuit current with line-side fuse protection
● at 440 V by gG fuse rated value 10 kA
● at 690 V by gG fuse rated value 6 kA
let-through current with closed switch
● at 240 V for combination switch + gG fuse maximum 3 kA
● at 440 V for combination switch + gG fuse maximum 3 kA
● at 690 V for combination switch + gG fuse maximum 3 kA
permissible
I2t value with closed switch
● at 240 V for combination switch + gG fuse maximum 2.5 kA2.s
● at 440 V for combination switch + gG fuse maximum 2.5 kA2.s
● at 690 V for combination switch + gG fuse maximum 3 kA2.s
design of the fuse link
● for short-circuit protection of the main circuit required fuse gL/gG: 20 A
● for short-circuit protection of the auxiliary switch required fuse gL/gG: 10 A
operational current of upstream fuse rated value 16 A
according UL
operational current at AC according to UL 508/UL 60947-4-1 16 A
rated value
operating voltage at AC at 50/60 Hz according to UL 508/UL 600 V
60947-4-1 rated value
active power [hp] at AC at 480 V according to UL 508/UL 60947- 7.5
4-1 rated value
active power [hp] at AC at 600 V according to UL 508/UL 60947- 10
4-1 rated value
short-time withstand current (SCCR) at 600 V according to UL 5 kA

3LD30540TK51 Subject to change without notice


3/21/2024
Page 2/5 © Copyright Siemens
508/UL 60947-4-1
continuous current of upstream fuse according to UL rated value 50 A
type of fuse according to UL RK5
Connections
AWG number as coded connectable conductor cross section
solid maximum
● 6
● 14
type of connectable conductor cross-sections for copper
conductor
● solid 1x (2.5 to 16 mm²)
● finely stranded with core end processing 1x (2.5...16 mm²)
● stranded 1x (2.5 to 16 mm²)
type of connectable conductor cross-sections for auxiliary
contacts
● solid 2x (0.75 ... 2.5 mm²), 1x 4 mm²
● finely stranded with core end processing 2x (0.75 ... 1.5 mm²), 1x 2.5 mm²
● stranded 2x (0.75 ... 2.5 mm²), 1x 4 mm²
type of electrical connection
● for main current circuit box terminal
● for auxiliary contacts Box terminals
Mechanical Design
height 60 mm
width 36 mm
depth 114 mm
type of device fixed mounting
fastening method Built-in unit fixed-mounted version
fastening method
● 4-hole front mounting No
● front mounting with central attachment Yes
● rail mounting No
net weight 200 g
Environmental conditions
ambient temperature during operation
● minimum -25 °C
● maximum 55 °C
ambient temperature during storage
● minimum -25 °C
● maximum 55 °C
Approvals Certificates
General Product Approval

Confirmation

other Environment

Miscellaneous Confirmation Environmental Con- Environmental Con-


firmations firmations

Further information
Information on the packaging
https://support.industry.siemens.com/cs/ww/en/view/109813875
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/lowvoltage/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3LD3054-0TK51
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3LD3054-0TK51

3LD30540TK51 Subject to change without notice


3/21/2024
Page 3/5 © Copyright Siemens
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3LD3054-0TK51
CAx-Online-Generator
http://www.siemens.com/cax
Tender specifications
http://www.siemens.com/specifications

last modified: 6/20/2023

3LD30540TK51 Subject to change without notice


3/21/2024
Page 4/5 © Copyright Siemens
3LD30540TK51 Subject to change without notice
3/21/2024
Page 5/5 © Copyright Siemens

You might also like