0% found this document useful (0 votes)
165 views8 pages

IMI Herion 97105 NAMUR Electromagnetic Valve

The document discusses NAMUR spool valves that are electromagnetic actuated and indirectly controlled. It provides technical specifications for the valves including materials used, temperature and pressure ratings, flow rates and certifications. It also includes ordering information and diagrams of the different valve models.

Uploaded by

Sina Mahmoudi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
165 views8 pages

IMI Herion 97105 NAMUR Electromagnetic Valve

The document discusses NAMUR spool valves that are electromagnetic actuated and indirectly controlled. It provides technical specifications for the valves including materials used, temperature and pressure ratings, flow rates and certifications. It also includes ordering information and diagrams of the different valve models.

Uploaded by

Sina Mahmoudi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

2

97105 NAMUR
5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled
G 1/4, 1/4 NPT, G 1/2, 1/2 NPT, flanged with NAMUR interface

For single and double operated actuators


VALVES

Closed - crossover design


Rectified solenoid coils
Add-on manual override
Suited for outdoor use under critical
environment conditions (see solenoid list)
Ex e mb, Ex d mb, Ex mb, Ex ia for zones 1 &
2 (gas), 21 & 22 (dust), ATEX cat. II 2GD
International approvals: IEC Ex, FM, CSA
others on request

Approval
depends on
DIN EN 61508 magnetic
IEC 61508 system

Technical data
Medium: Fluid/Ambient temperature: Materials:
Filtered, non-lubricated and dried Valve: Body: Aluminum 3.0615 with
compressed air, instrument air, -40 ... +65°C (SNBR) surface treatment for rough
nitrogen and other non-flammable (-40...+149°F) environmantal conditions.
neutral, dry fluids -25 ... +80°C (HNBR) Approved according to DIN
Operating pressure: (-13...+176°F) 50018: Condensate test with
2,5 ... 8 (36 ... 116 psi) Depending on solenoid system. alternating temperatures in
with internal air supply Air supply must be dry enough to avoid sulphuric atmosphere, DIN 50021/
0 ... 8 bar (0 ... 116 psi) ice formation at temperatures below +2°C ASTM B117-73: Salt spray test
(+35°F).
with external air supply with different sodium chloride
(G1/2, 1/2 NPT or low power pilot For outdoor installations all solutions, tested in ammonia
system only) connections must be protected atmosphere). Stainless steel
against the penetration of 1.4404 (316 L)
moisture and a solenoid with IP66 Seals: SNBR (special NBR) or
protection must be used! HNBR

The solenoid valves are used


in ATEX zones, resulting from
Protection Class Atex-category of
solenoids (see table of solenoids).

VAL-432
For further information www.norgren.com
2
97105 NAMUR
5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled
G 1/4, 1/4 NPT, G 1/2, 1/2 NPT, flanged with NAMUR interface

Housing: Aluminum anodized, Pilot flange: SNBR -40...+65C *3)

VALVES
Symbol Valve Port size Actuation/ Operating Flow *4) Test certificate
model *1) 1, 3, (5) 2, 4 Return pressure (l/min) IEC 61508 *2)
(bar)

9710505* G 1/4 Flange Solenoid/Spring 2.5 ... 8 1300 x

4 2 4 2 9710515* 1/4 NPT Flange Solenoid/Spring 2.5 ... 8 1300 x


V-32spec-EM-F V-52-EM-F
5 13 513 9710595* G 1/2 Flange Solenoid/Spring 2.5 ... 8 2600

4 2 4 2
9710596* 1/2 NPT Flange Solenoid/Spring 2.5 ... 8 2600
V-32spec-EMH-F V-52-EMH-F
5 13 513
4 2 9711505* G 1/4 Flange Solenoid/Solenoid 2.5 ... 8 1300
4 2
4 2 4 2
V-32spec-EM-EM V-52B-EM
5 13 V-32spec-EMR-F 9711515*
V-52-EMH-F 1/4 NPT Flange Solenoid/Solenoid 2.5 ... 8 1300
513
521 3 513
4 4 2
Order example: To order a series 97105 NAMUR valve, aluminum, G ¼” port with a 24 Vdc, IP65, DIN Form A coil, Model Number: 9710505076302400.
V-32spec-EMH-EMH
Valve model code 9710505 + Coil code 076302400 = Model Number: 9710505076302400.
V-52B-EMH
5 13
To order the valve only, replace the * after the
5 1Valve
3 model code from the table with 9 zero’s, i.e. 9710505000000000.
4 2
4 2
V-32spec-EMR-EMR
5 13 V-52B-EMR
513

Housing: Stainless steel, Pilot flange: SNBR -40...+65C *3)


Symbol Valve Port size Actuation/ Operating Flow *4) Test certificate
model *1) 1, 3, (5) 2, 4 Return pressure (l/min) IEC 61508 *2)
(bar)

9710705* G 1/4 Flange Solenoid/Spring 2.5 ... 8 1300 x


4 2 4 2
V-32spec-EM-F V-52-EM-F
9710715* 1/4 NPT Flange Solenoid/Spring 2.5 ... 8 1300 x
5 13 513

9711705* G 1/4 Flange Solenoid/Solenoid 2.5 ... 8 1300


4 4 2 2 44 22
V-32spec-EMH-F
V-32spec-EM-EM V-52-EMH-F
V-52B-EM
9711715* 1/4 NPT Flange Solenoid/Solenoid 2.5 ... 8 1300
5 153 1 3 55
1133
4 4 2 2 44 22
*1 Order example: To order aV-32spec-EMH-EMH
series 97105 NAMUR valve, stainless steel, G ¼” port with a 24 Vdc, IP65, DIN Form A coil, Model Number: 9710705076302400.
V-32spec-EMR-F V-52-EMH-F
Valve model code 9710705 + Coil code 076302400 = Model V-52B-EMH
Number: 9710705076302400.
5 13
To order the valve 5only,
1 3replace the * after the
55 1
3 3 model code from the table with 9 zero’s, i.e. 9710705000000000.
1 Valve
4 2
1/4 NPT Flange Solenoid/spring Aluminum 4 2 2.5… 8 1300 0.45 4 9710219 G 1/4 Flange Solenoid/solenoid Aluminum 2.5…
V-32spec-EMR-EMR
*2) Since May 2008, Date code A8192
5 1 3 V-52B-EMR
*3)For operation in plants according to IEC 61511/61508 -40 ... +40°C see test certificate (on request)
513
*4) Flow characteristics conforms to ISO6358 [6 » 5 bar]
Note for *4): Connecting pipe / Fitting: ​In order to ensure and a pressure collapse avoid the flow, the supply air cross section shouldwith 1/4:
≥ 8 mm; with 1/2: ≥≥ 10 mm. With smaller cross section the inlet (A1) should more largely, however at least equally large line at the port (A2; A1).

VAL-433
For further information www.norgren.com
2
97105 NAMUR
5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled
G 1/4, 1/4 NPT, G 1/2, 1/2 NPT, flanged with NAMUR interface

Solenoid operators
VALVES

Power consumption Rated current Ex- Protection Class Temperature Electrical Order Coil code
Protection (ATEX-Category) Ambient/ connection separate
24 VDC 230 VAC 24 VDC 230 VAC Nominal resistance Medium (°C)
(W) (VA) (m A) (m A) (according to EN60529)
1.9 11 - IP00 without Connector -25 ... +60 DIN EN 175 301-803 0000000076302400 076302400
IP65 (with Connector) Form A *5) *6)
2.1 *5) 78 0000000076323050 076323050

0.8 - 38 - II2G Ex e mb IIC T5/T6 Gb -40 ... +80 T5 M20 X 1.5 *6) 0000000420002400 420002400
-40 ... +70 T6
II2D Ex tb IIIC T130°C Db -40 ... +80
IP 66 (with cable gland)
- 1.3 - 6 II2G Ex e mb IIC T5/T6 Gb -40 ... +80 T5 M20 X 1.5 *6) 0000000420123050 420123050
-40 ... +70 T6
II2D Ex tb IIIC T130°C Db -40 ... +80
IP 66 (with cable gland)
0.8 - 33 - II2G Ex d mb IIC T5/T6 Gb -40 ... +80 T5 1/2 NPT *6) 0000000460002400 460002400
Ex e mb IIC T5/T6 Gb -40 ... +70 T6
II2D Ex tb IIIC T130°C Db -40 ... +80
IP 66 (with cable gland)
0.8 - 33 - II2G Ex d mb IIC T5/T6 Gb -40 ... +80 T5 M20 X 1.5 *6) 0000000460202400 460202400
Ex e mb IIC T5/T6 Gb -40 ... +70 T6
II2D Ex tb IIIC T130°C Db -40 ... +80
IP 66 (with cable gland)
- 1.3 - 6 II2G Ex d mb IIC T5/T6 Gb -40 ... +80 T5 1/2 NPT *6) 0000000460123050 460123050
Ex e mb IIC T5/T6 Gb -40 ... +70 T6
II2D Ex tb IIIC T130°C Db -40 ... +80
IP 66 (with cable gland)
- 1.3 - 6 II2G Ex d mb IIC T5/T6 Gb -40 ... +80 T5 M20 X 1.5 *6) 0000000460323050 460323050
Ex e mb IIC T5/T6 Gb -40 ... +70 T6
II2D Ex tb IIIC T130°C Db -40 ... +80
IP 66 (with cable gland)
0.8 – 33 – II2G Ex mb d IIC T4/T6 Gb -40 ... +50 T4 M20 X 1.5 *6) 0000000480202400 480202400
Ex mb e II T4/T6 Gb -40 ... +40 T6
Stainless Steel
IP 66 (with cable gland)

1.3 – 6 II2G Ex mb d IIC T4/T6 Gb -40 ... +50 T4 M20 X 1.5 *6) 0000000480323050 480323050
Ex mb e II T4/T6 Gb -40 ... +40 T6
IP 66 (with cable gland)

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design Attention: The protection class for coil series 46xx and 48xx is determined by the choice of
according to VDE 0580, EN 50014/50028. 100% duty cycle. cable gland.
*5) Required connector: model 0570275 for V DC; model 0663303 for V AC, to be ordered
Solenoid Voltage 200V DC! Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the
*6) Connector cable gland not supplied, see table »Accessories« solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of
proteciton is used, the solenoid will have protection class Ex e mb.

Approvals
Model Approvals
ATEX IECEx
42xx KEMA 98 ATEX 4452 X IECEx KEM 09.0068X
46xx PTB 02 ATEX 2085 X IECEx PTB 11.0094X
48xx PTB 06 ATEX 2054 X IECEx PTB 07.0039X

VAL-434
For further information www.norgren.com
2
97105 NAMUR
5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled
G 1/4, 1/4 NPT, G 1/2, 1/2 NPT, flanged with NAMUR interface

Solenoid actuators for intrinsically-safe circuits

VALVES
Nominal- Min. required Resistance Required Protection Class *1) Temperature Order separate Coil code
resistance RN switching RW 60 Coil voltage- (ATEX-Categorie) Ambient/Medium
coil current (Ω) at terminal IP-Protection*1) (°C)
(Ω) (mA) Rw 60 (V) (class according to EN60529)
200 33 240 8 II2G Ex ia IIC T6 Gb -40 ... +60 0000000205000000 205000000
II2G Ex ia IIC T4 Gb -40 ... +80
II2D Ex iaD 21 T80°C Db -40 ... +60
II2D Ex iaD 21 T100°C Db -40 ... +80
IP 66 (with cable gland)
391 24 460 11 II2G Ex ia IIC T6 Gb -40 ... +60 0000000205100000 205100000
II2G Ex ia IIC T4 Gb -40 ... +80
II2D Ex iaD 21 T80°C Db -40 ... +60
II2D Ex iaD 21 T100°C Db -40 ... +80
IP 66 (with cable gland)
736 17 880 15 II2G Ex ia IIC T6 Gb -40 ... +60 0000000205200000 205200000
II2G Ex ia IIC T4 Gb -40 ... +80
II2D Ex iaD 21 T80°C Db -40 ... +60
II2D Ex iaD 21 T100°C Db -40 ... +80
IP 66 (with cable gland)
1220 13 1460 19 II2G Ex ia IIC T6 Gb -40 ... +60 0000000205300000 205300000
II2G Ex ia IIC T4 Gb -40 ... +80
II2D Ex iaD 21 T80°C Db -40 ... +60
II2D Ex iaD 21 T100°C Db -40 ... +80
IP 66 (with cable gland)
IP-Protection class *1) (to EN 60529) T When selecting an intrinsically safe power supply, the Ui = 45 V Ii = 500 mA according to Tab. A. 208x PTB 06
*1) Ex protection classes and temperature values are valid for permissible maximum values according to the Certificate of ATEX 2001U — — N/en 7.1.540
all solenoid. Conformity should be taken into account.

Accessories
Cable gland Model Thread Cable Ø Material Protection Connector
Protection Ex e, Ex d (ATEX), class
Nickel plated brass/ (ATEX)
stainless steel
0588819000000000 M 20x1.5 5.0...8.0 mm Nickel plated brass II2GD Ex e

0588851000000000 M 20x1.5 10...14 mm Nickel plated brass II2GD Ex d

0588925000000000 1/2-14-NPT 7.5...11.9 mm Nickel plated brass II2GD Ex d

0589385000000000 M 20x1.5 9.0...13 mm Model Approvals 1.4571 (316 Ti) II2GD Ex e

0589395000000000 M 20x1.5 7.0...12 mm Model Approvals 1.4571 (316 Ti) II2GD Ex d 0570275000000000

0589387000000000 M 20x1.5 10...14 mm Model Approvals 1.4571 (316 Ti) II2GD Ex d 0663303000000000 (with rectifier)

Adaptor complete Silencer Silencer Exhaust guard Filter cartridge Add-on manual override Add-on manual override
(Adaptor, inlet filter (plastic) (stainless steel) *2) (for start-up only)
and seal ring) *1) *1)

0613487000000000 M/S2 (G1/4) 0014613000000000 (G 1/4) 0613422000000000 (1/4") 0681173000000000 (1/4") 0553886000000000 0613379000000000
(without detent) (without detent)
C/S2 (1/4 NPT) 0613678000000000 (1/4 NPT) 0613423000000000 (1/2") 0553887000000000
(with detent)
M/S4 (G1/2) 0014813000000000 (G 1/2)

C/S4 (1/2 NPT) 0613679000000000 (1/2 NPT)

*1) For indoors use only


*2) For outdoors use ~ 0,2 (bar)

Approvals
Model Approvals
ATEX IECEx FM
205x PTB 07 ATEX 2019 X IECEx PTB 07.0017 —

VAL-435
For further information www.norgren.com
2
97105 NAMUR
5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled
G 1/4, 1/4 NPT, G 1/2, 1/2 NPT, flanged with NAMUR interface

Valves
VALVES

5 1 3 5 1 3

1 2 3.76
4.88
2.81

0.14

0.14
4 2
1.77

1.26

4 2

1.77

1.26
6 0.60
6 0.60
0.78
0.78
2.01 0.94

3
3
4.17

1.61 0.87

4.17
0.18

1.81
0.53
1.08

0.53

1.08

0.53
5/2
5/2
5.43
0.28

0.28

2.42
6
3.29

5 1 3 4.15
6.38
4.47

3 3.52
0.14
1.77

4 2
1.26

6 0.60
0.78

3
4.17
0.18
1.08

0.53

5/2
0.28

3.11
6 3 Port G 1/4 or 1/4 NPT
3.98
4.84 6 NAMUR connection plate 3/2 or 5/2 way function
6.91

Dimensions in inches

VAL-436
For further information www.norgren.com
2
97105 NAMUR
5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled
G 1/4, 1/4 NPT, G 1/2, 1/2 NPT, flanged with NAMUR interface

Solenoid operators

VALVES
3.41
3 5 6 2
2.11 1
4.21
1.93

0.67

1.60
1.61
1.60

1.69

2.54
1.06
3.25
3.50

10 ± 0,2
M16 x 1.5 0.47 5

1.65
1.30
1.34
1.69

1.10

2.15
0.77
1.06 2.50
2.87

2.78 2

2
7 8 1/2 - 14 NPT
1.63

2.09

1.59
0.79

3 2.32

3.31
2.48 0.08
2.20

1.69
1.32

1.14 1.69
4.80
1.02 4

2
4.21
17
1.60
2.54
~ 3.60

1.06
0.4 ± 0.008

M 20 x 1.5

1 Connector 4 x 90° turnable


1.65
2 Ø 13 (with spacer tube)
3 M20 x 1.5 or 1/2 - 14 NPT
4 Flying leads 450 mm long
2.15

5 M20 x 1.5

Dimensions in inches

VAL-437
For further information www.norgren.com
2
97105 NAMUR
5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled
G 1/4, 1/4 NPT, G 1/2, 1/2 NPT, flanged with NAMUR interface

Circuit diagrams
VALVES

1 4 5 7

10 20 21

T T

NAMUR hole pattern (driving side)


Port size G1/4
32
M5 4

2 2 Port 2 (A)
3 Hole for coding stud
24

4 M5 (10 deep)
2 3
5 Port 3 (R)
3

Conversion instructions of 5/2 into


3/2 way function

5/2 way function (original mode of supply) 3/2 way function

5/2 3/2

7 6 7 6

Conversion from 5/2 to 3/2 function may be achieved 6 Arrow Dimensions in mm


by swapping or turning enclosed adaptor plates. 7 Marker
Make sure Marker and Arrow match as shown
on above drawing.

VAL-438
For further information www.norgren.com
2
97105 NAMUR
5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled
G 1/4, 1/4 NPT, G 1/2, 1/2 NPT, flanged with NAMUR interface

Manual override

VALVES
Model: 0553886 (without detent) Model: 0553887 (with detent)

14 14

~11 ~11
M10 x 0,5

M10 x 0,5
Cable gland
A B C øD Model
C C
M20 x 1.5 9 36 5 to 8 22 0588819000000000
B D B D
M20 x 1.5 6.5 27.5 9 to 13 22 0589385000000000
M20 x 1.5 14 39 10 to 14 24 0588851000000000
1/2-14 NPT 15 58 7.5 to 11.9 24 0588925000000000
A

M20 x 1.5 14 39 7 to 12 24 0589395000000000


M20 x 1.5 10 34 10 to 14 24 0589387000000000
0588925 only

Dimensions in mm

VAL-439
For further information www.norgren.com

You might also like