HANDHELD LASER DISTANCE METER
USER MANUAL EnglishIntroduction
Firstly thank you for your choice on our handheld laser distance
meter.
Please carefully read the safety instructions and the user manual
before using this product, otherwise it may result in hazardous
laser radiation and electric shock. The person responsible for the
equipment must ensure that all users understand these directions
and adhere to them.
Safety Instructions
4.This product is a class II laser product. Please DO NOT stare
into beam at any time when operating this product!
2.Please DO NOT looking directly into the beam with optical aids
(e.g. binoculars, telescopes)!
3.Please DO NOT remove any safety labels on this product!
Caution:
4.Please avoid kids to use the meter.
2.Do not open the meter without allow from professional person.
3.Please keep the manual, it is useful when you use it.
Unpacking inspection
1,Mainframe
one unit
2,User manual one piece
3,AAA battery(2*1.5V) two pieces
4,holding rope one pieceBasic Functions
Single Measurement
Max. / Min. Measurement
Continuous Measurement
Area / Volume / Pythagoras
Plus and Minus
Meter/Ft/In Switch
Measuring Reference
Buzzer Indicator
Historical Data Records
Data Clean up
Error Message Code
Battery Indicator
Digital Level(angle measuring)
Laser Auto. Switch off
Instrument Auto. Switch off 180s
Telemeasuring height directly, even though there are some
barriers in front of target. =
Be.
8Technical Parameters:
F
Measuring Range 0.05m~40m 4
0.05m~60m
0.05m~80m 2
0.05m~100m 3
0.05m~120m 4
0.05m~150m S
Measuring Accuracy £1.5mm 5
Measuring Unit ™,ft,in zg
Laser type 620~690nm
Laser Class I class,<1mw LC
Single Measurement Time 0.25s
Operating Temperature 0~+40C
Storage Temperature -20~+65C
Batteries AAA(Alkaline), 2x1.5V
Measurements Per Battery Set >8000
Weight (Without Batteries) Approximately 82g
Dimensions (LxWxH) 115 x 50 X 23mm
Comment:
* The deviation occurs under unfavorable conditions such as
bright sunlight or when measuring too poorly reflecting or very
rough surfaces, the environment temperature is too high or too
low.
™ When measuring distance within 10m, measurement pos
_1s £1.5mm; more than 10m, measurement accuracy is eas
ollows: +1.5mm + 0.05* (D-10) (D: Measuring Distance.Forbidden
4, Opening the equipment by using
without allow.
. Measuring to sun
Others measuring out of appointed range.
immersing the equipment in water.
Cleaning the lens using alcohol or any other organic solvent.
. Wiping the lens directly with fingers or other rough surfaces.
. Powering the equipment beyond the rated DC voltage.
tools (screwdrivers, etc.)
NOObhwoN
LCD Indicator
Laser indication and reference
Continue measuring
Area volume measuring
Pythagoras measuring
Error indication rorya | Hi: (eee a
ahahaha) a
nO cr"
Power indication
Max and min indication
Date storage
Unit indication
Angle indication
Current measurement
Caculation displayKeyboard Indicator
Switch on/Measuring
Measuring Reference
Historical Data/ Unit Switch
Clean up/Switch off
FOeEle
Function Switch
Plus/forward
Minus/Backward
qStart-up
1 Battery Installation con Corps iid.
ccording to figures, remove battery iment =
> aa paneries with correct polarity according to battery
indications
c. Close the battery compartment lid
figure A
*Caution:
1. Please do not mix new and old batteries, Use alkaline
batteries or rechargeable batteries only.
2. Please replace batteries when the symbol flashes
permanently in the display
3. Please remove the batteries before any long period of
non-use
4. Out of power batteries must not be disposed of with
household, care for the environment and take them to the
collection points provided in accordance with national or local
regulationsOperation
Switch on/off
Short-time press button to switch on
the equipment, indication as shown as
figure A.
figure A
Change Measurement Reference
Default measuring reference is the bottom of meter, short-time
Press (4 )to change the measuring reference to the top of meter.
Short-time press &, laser reflection signal indication will display,
meanwhile battery intensity indication display as shown as figure B;
figure BLong-time press & to switch off the equipment.
The laser will be switched off automatically after 30 seconds a
equipment will be powered off after 3 minutes without any ope’
Clear Button
Short-time pressing & button to clear the last command o
displayed data one by one;
Measurement
Single-mode Measurement
When equipment is switched on, short-time press @ will activate
the laser, then aim the laser onto target and press @ again will
trigger single-mode measurement, the result is will results displayed
immediately as shown in figure D.Continuous-mode Measurement
When the equipment is switched on, long-lime pressing @> button
will trigger continuous-mode measurement .
MIN; MINIMUM VALUE
MAX: MAXIMUM VALUE
Current measurement value is displayed in LCD bottom line as sh
Own
in figure E.
figureE
Functions
Area, Volume. Indirect Mea:
s isurem
ee ine ent (Pythagorean Theorem)
wi : figure F
hen the €quipment is switched on, Press @ro switch
me:
‘@Surement functions one by one. Select corresponding function
4nd begin the measurement
9Measurement Levey aT)
Measuring Area
Q
ch
Measuring Volume
Telemeasuring height
directly(Pythagoras)
IN
auring height 5 Z|
(twice Phthagoras plus) : Nl
Telmeauring height directly A
twice Phthagoras minus) 1
Plus and Minus Functions
When the status is single-mode Measurement.
Press + the meter can calculate the last measurement a
Current measurent.
Press -, the meter can calculate the last measurement minus
the current measurent.figure G
2
eon
maT R) H
SHE
nan itty
10Storage
1)Storage m'
data records.
and Recall of Measurements
easurements: press the to review historical
2)Press + or — buttons to scroll through the measurements.
Message Code | Possible cause
Battery too low
Out of range
figure |
Remedy
Change batteries
Measure target within the range
Received signal
too weak
Background
brightness too high
Out of display
Use light color target;
Hold Quick Measure
more stead!
Use dark colored target