AST302-Basic Rotary

Supplemental Schematics
Table of Contents
PROCESS & INSTRUMENTATION DIAGRAMS

39899828 M45/M55/M75 P&ID (A/C) …………………………………………………………………………………………. 1

54579081 DIAGRAM, PROCESS AND INSTRUMENTATION AIR COOLED ………………………………………… 2

23972649 DIAGRAM, P & I, STANDARD CONTROL ………………………………………………………………………… 3

48775258 DIAGRAM, PROCESS & INSTRUMENTATION …………………………………………………………………. 5

24230070 P&ID, R4-11KW ……………………………………………………………………………………………………………. 7

24435588 DIAGRAM, P & ID 30-37KW (FS) …………………………………………………………………………………… 9

23700339 DIAGRAM, P & ID (AC/WC) 30-37KW (FSD) ………………………………………………………………….. 12

47531031 DIAGRAM, P&ID RS30-37IE (FSD) ………………………………………………………………………………… 15

23371669 DIAGRAM, P & ID (AC/WC) 90-160 KW (FSD) ……………………………………………………………….. 18

49063217 DIAGRAM, P&ID (AC/WC) RS200-355KW ……………………………………………………………………… 20

ELECTRICAL SCHEMATICS

39899794 DECAL, WIRING SCHEMATIC FULL VOLTAGE ………………………………………………………………… 23

39899786 DECAL, WIRING SCHEMATIC START DELTA …………………………………………………………………… 24

47618055 DECAL, ELECT. SCHEMATIC UP6 5-15HP 1PH & 3PH DOL (N.A.) ……………………………………. 25

24771099 DECAL ELECT. SCHEMATIC UP6 5-15HP DOL THREE PHASE (A.P.) …………………………………. 26

32343956 SCHEMATIC – PEGASUS ELECTRICAL DOL ……………………………………………………………………… 27

32343931 SCHEMATIC – PEGASUS ELECTRICAL S/D ………………………………………………………………………. 28

39878327 DECAL, WIRING SCHEMATIC FULL VOLTAGE …………………………………………………………………. 29

39846589 SCHEMATIC, WIRING START DELTA, PH. MONITOR ………………………………………………………. 30

39878236 DECAL, WIRING SCHEMATIC STAR DELTA ……………………………………………………………………… 31

48775233 SCHEMATIC, ELECTRICAL DIAGRAM Xe-70M (FS-SD) …………………………………………………….. 32

24437675 DECAL, ELECTRICAL WIRING, DOL, Xe-50M …………………………………………………………………… 34

24153595 DECAL, ELECTRICAL WIRING, S/D. Xe-50M ……………………………………………………………………. 36

24437683 DECAL, ELECTRICAL EIRING, S/D, Xe-70M ……………………………………………………………………… 38

24276602 SCHEMATIC, ELECTRICAL WIRING (FS-YD) ………………………………………………………………….…. 41

23603582 SCHEMATIC, ELECTRICAL WIRING (FS-SD) …………………………………………………………………….. 44

49107048 SCHEMATIC, ELECTRICAL WIRING (FS-SD) ARES ……………………………………………………………. 47

48957567 SCHEMATIC, ELECTRICAL WIRING (FS-SD) …………………………………………………………………….. 52


8 7 6 5 4 3 2 1
REVISIONS
ZONE REV ECN DESCRIPTION DATE DRAWN APP'D
A CN-1025182 CHANGE INLET VALVE and air filter 20160106 Junli Renny
B

D D

C C

B B

A A
WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED DO NOT SCALE DRAWING
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO THIRD ANGLE PROJECTION
PROPRIETARY NOTICE ASME Y14.5M - 1994 DRAWN DATE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, JUNLI 2016MAR23
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE TITLE
GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION 2016MAR23
R.CAI
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS APPROVED DATE

2016MAR23
0003 ,' $&
- WELD SYMBOLS TO BE IN ACCORDANCE R.WANG
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION WITH ANSI/AWS A2.4 DRAWING TYPE
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS SIZE DWG NO. REV
Detail Drawing
EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET
INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPYRIGHT @ 2012
Ingersoll Rand
NOMENCLATURE
A1  A
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. ALL RIGHTS RESERVED
SCALE:
1:1 UNIT:
COUGAR SHEET
1 OF 1

8 7 6 5 4 3 2 1
A.1

1
52805.02.05

2
8 7 6 5 4 3 2 1
REVISIONS
NOTES : ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

A 80171 ORIGINAL RELEASE 2011OCT11 P.SADASHIV B.LEWIS


1. FOR CUSTOMER CONNECTION SIZES AND LOCATIONS SEE FOUNDATION PLAN OF UNIT. 2,C6 B 81962 DEFINED DRYER "BYPASS (OPTION)". 2013JUL29 OWANESIAN C.H.FRAZIER
TITLE BLOCKS, "SINGLE PHASE" REMOVED FROM
TITLES.
2. COMPONENTS INSIDE DOUBLE LINES ARE OPTION MODULE. C1 C 82594 SHEET 1, ITEM 39 ADDED TO COMPONENT TABLE. 2014MAR27 M.CURRY
C.H.FRAZIER
T.VINCENT
D5 SHEET 2, IN "AIR RECEIVER (OPTION)", ITEMS 17, 18
AND 39 ADDED.
1D4 D 82790 ADD LINE FROM BLOWDOWN SOL COIL POST 2014MAY21 R. REDMON C. FRAZIER
TO ATMOSPHERIC VENT ON INLET VALVE TO
10 3SV ADDRESS ANY WEEPING FROM BLOW DOWN VALVE;
1C8 AND ADD LINE FROM BLOW DOWN VALVE OUTLET TO
INLET VALVE TO ASSIST CLOSING INLET VALVE.
1C4 CORRECTED VIEW BY ATTACHING RELIEF VALVE TO
D SEP. TANK. UPDATED DRAWING FORMAT. D
1D3 ADDED FILTER SYMBOL AND LINE FOR CONDENSATE, K.CODY
REVISED LINE ROUTE FROM FILTER TO SOL
BLOWDOWN VALVE, ADD FILTER TO TABLE #40
C3 E 1117762 REMOVED FILTER SYMBOL AND FILTER #40 FROM 2016OCT06 H.AVINASH C.FRAZIER
TABLE. REVISED LINE ROUTE FROM MPCV TO
SOL BLOWDOWN VALVE AND SOL LOAD VALVE.

19

20

1SV R
39 VALVE, OUTLET
A 38 RECEIVER, AIR
P
37 VALVE, AUTO DRAIN
36 COMPRESSOR, REFRIGERANT
35 VALVE, HOT GAS BYPASS
C 34 CONDENSER C

12 33 FILTER DRIER, REFRIGERANT


17 11 32 TUBE, CAPILLARY
16 31 VALVE, CONDENSATE
5 30 INDICATOR, DEW POINT
4

M T 29
28
EVAPORATOR
VALVE, CHECK
2
P 27
26
MOISTURE SEPARATOR
VALVE, ISOLATION (OPTION)
1 6 7 25 RECUPERATOR
3 21
24 VALVE, CHECK
8 23 FILTER, HIGH EFFICIENCY AIR
22 FILTER, GENERAL PURPOSE AIR
9 21 GAUGE, PRESSURE
20 VALVE, SOLENOID 1SV LOAD
18 CONTINUED 19 SCREEN, SCAVENGE
ON SHEET 2 18 VALVE, DRAIN
17 VALVE, RELIEF
B B
16 DIFFUSER
15 COOLER, OIL
14 THERMOSTAT
13 FILTER, COOLANT
12 SWITCH, TEMPERATURE
14 T 11 SWITCH, PRESSURE
13 10 VALVE, SOL BLOWDOWN 3SV
9 AFTERCOOLER
8 VALVE, MINIMUM PRESSURE
7 TANK, SEPARATOR - FINE
15 6 TANK, SEPARATOR - COARSE
PIPING LEGEND 5 RELAY, MOTOR OVERLOAD
AIR/COOLANT 4 MOTOR
AIR 3 AIR END ASSEMBLY
COOLANT 2 VALVE, AIR INLET
1 FILTER, AIR
CONDENSATE
DIAGRAM
POSITION DESCRIPTION
COMPONENT
A BOUNDARY KEY TO COMPONENT A
WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED DO NOT SCALE DRAWING
REFRIGERANT BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO THIRD ANGLE PROJECTION
PROPRIETARY NOTICE ASME Y14.5M - 1994 DRAWN DATE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, P.SADASHIV 2011OCT11
R

INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE NAME
GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS
C. FRAZIER
APPROVED
2011OCT11
DATE
DIAGRAM, P & I, STANDARD
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS
- WELD SYMBOLS TO BE IN ACCORDANCE
WITH ANSI/AWS A2.4
B. LEWIS 2011OCT11
DRAWING TYPE
CONTROL D AG
I R M,
A P & I, STA DN ARDC NO TROL

SIZE ESTIMATED WEIGHT DWG NO. REVISION


EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET Detail Drawing
INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPYRIGHT @ 2016
Ingersoll Rand
NOMENCLATURE
A1 DNA 23972649
(KG UNLESS OTHERWISE SPECIFIED)

E 23972649

PART NO.
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. SCALE MODEL SHEET
ALL RIGHTS RESERVED 0.25 SMALL UP 1 OF 2
For Internal Use:Model=23972649|PART|E.0|Avinash HV|06-Oct-16 03:49:07 PM|Open<>Drawing=23972649|DRAW|E.0|Avinash HV|06-Oct-16 03:49:36 PM|Open

8 7 6 5 4 3 2 1
06-Oct-2016 04:20:14 (model E.0/E.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.0

3
8 7 6 5 4 3 2 1

17

D 38 D

39

37

18

AIR RECEIVER (OPTION)

33 34

C C

35
32

26
BYPASS (OPTION) 26
M
36
22 23 29

26
FROM SHEET 1
25

27 30

B B

24

28

31

INTEGRAL DRYER (OPTION)

A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND
DIAGRAM, P & I, STANDARD DIAG
ST ANDA
R A M
,P C
D &
R IONTR
, L
O

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
CONTROL
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 23972649
PART NO.
23972649 E
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 0.25 SHEET 2 OF 2

8 7 6 5 4 3 2 1
06-Oct-2016 04:20:14 (model E.0/E.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.0

4
100314.07.41

18,579
8 7 6 5 4 3 2 1 825,579

REVISIONS

NOTES : ZONE REV ECN DESCRIPTION DATE DWN APV

1. FOR CUSTOMER CONNECTION SIZES AND LOCATIONS SEE FOUNDATION PLAN OF UNIT. A 82169 ORIGINAL RELEASE 2013DEC18 M.WAGENHAUSER S.EATON
2. COMPONENTS INSIDE DOUBLE LINES ARE OPTION MODULE.

3SV

20

D D

6SV
40

MODULATION (OPTION) P
A
R

41
3 5SV
1SV 39 46 VALVE, ISOLATION (AIR RECEIVER)
42
45 MANUAL DRAIN VALVE (AIR RECEIVER)
R R 44 VALVE, SAFETY (AIR RECEIVER)
A A
P 43 TRANSDUCER, PRESSURE (WET SUMP)
P
19 42 VALVE, MODULATION
41 VALVE, SHUTTLE
40 VALVE, SOLENOID 6SV (MODULATION)
39 VALVE, SOLENOID 5SV (MODULATION)
38 VALVE, ISOLATION
C C
37 3 WAY VALVE, BYPASS
36 FILTER, AIR
21 17
35 MOISTURE SEPARATOR
22
34 SENSOR, TEMPERATURE
16
5 43 TRANSDUCER, PRESSURE
33
(PACKAGE DISCHARGE)
M 31 AUTO DRAIN VALVE
8 30 RECEIVER, AIR
29 CONDENSATE DRAIN VALVE
1 6 7 9 28 INDICATOR, DEW POINT
4
27 EXPANSION VALVE
CONTINUED IN SHEET 2 26 FILTER, REFRIGERANT
25 CONDENSER
24 EVAPORATOR
2 34 33 23 REFRIGERANT COMPRESSOR
18 22 INDICATOR, AIR FILTER RESTRICTION
21 ORIFICE
20 VALVE, SOLENOID 3SV (BLOWDOWN)
B B
19 SCREEN, SCAVENGE
18 VALVE, DRAIN
17 VALVE, SAFETY (SEPARATOR TANK)
16 RELAY, MOTOR OVERLOAD
15 COOLER, OIL

13
14 T 14 THERMOSTAT
13 FILTER, COOLANT
9 AFTERCOOLER
8 VALVE, MINIMUM PRESSURE
7 ELEMENT, SEPARATOR - FINE
15 6 TANK, SEPARATOR - COARSE
PIPING LEGEND 5 MOTOR
AIR/COOLANT 4 AIR END ASSEMBLY
3 VALVE, SOLENOID 1SV (LOAD)
AIR
2 VALVE, AIR INLET
COOLANT
1 FILTER, AIR
CONDENSATE DIAGRAM
DESCRIPTION
POSITION
COMPONENT KEY TO COMPONENT A
A
BOUNDARY
402,81 615,81 825,81

WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED DO NOT SCALE DRAWING
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO
REFRIGERANT ASME Y14.5M - 1994
THIRD ANGLE PROJECTION
PROPRIETARY NOTICE DRAWN DATE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, M.WAGENHAUSER 2013DEC18
R

INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE NAME
GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS
M.CAIN
APPROVED
2013DEC18
DATE
DIAGRAM, PROCESS &
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS
- WELD SYMBOLS TO BE IN ACCORDANCE
WITH ANSI/AWS A2.4
S.EATON 2013DEC18
DRAWING TYPE
INSTRUMENTATION D AG
I RM
A , PR OCE SS& IN TS RUME NTAT
O IN

SIZE ESTIMATED WEIGHT DWG NO. REVISION


EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET Detail Drawing
INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPYRIGHT @ 2014
Ingersoll Rand
NOMENCLATURE
A1 0.0 kilogram 48775258
(KG UNLESS OTHERWISE SPECIFIED)

4877525 8

PART NO. A
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. SCALE MODEL SHEET
18,18 402,18
ALL RIGHTS RESERVED 0.20 UP6 20-30HP / UP5 15-22KW 1 OF 2
For Internal Use:Model=48775258|PART|A.0|Wagenhauser, Matthew|18-Dec-13 05:24:51 PM|Open<>Drawing=48775258|DRAW|A.4|Wagenhauser, Matthew|16-Apr-14 04:00:40 PM|Open

8 7 6 5 4 3 2 1
02-Oct-2014 20:51:30 (model A.0/A.4)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED A.4

5
18,579 18,579
8 7 6 5 4 3 2 1 826,579

D D

27 26

C C
44

M
23
35 24 25 30
36
37 38 46

FROM SHEET 1
28
31 45
29

AIR RECEIVER (OPTION)

BYPASS OPTION
B B

INTEGRAL DRYER (OPTION)

A A

636,54 825,54

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, PROCESS & D AG
I RAM
, PR OCE SS
& IN STRU ENT
M TA ON
I

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
INSTRUMENTATION
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 48775258
PART NO.
48775258 A
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 0.20 SHEET 2 OF 2
18,18 18,18 636,18

8 7 6 5 4 3 2 1
02-Oct-2014 20:51:30 (model A.0/A.4)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED A.4

6
8 7 6 5 4 3 2 1
REVISIONS
NOTES :
ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

A 761167 CANCELLED REVISION 2014FEB25 T.RAGHU S.KRIZEK


1. FOR CUSTOMER CONNECTION SIZES AND LOCATIONS SEE FOUNDATION PLAN OF UNIT. B 761167 ORIGINAL RELEASE 2014FEB2014 S.KRIZEK M.KLECH
C 844787 ADDED HELPING LINE FOR REGULATION 2014JUL2014 S.KRIZEK Z.WHITLEY
2. A : SOLENOID VALVE PORT MARKED A 1-D8 D 960610 ADDED NOTE 2. 2014DEC10 N.KESHAVA Z.WHITLEY
I : BLOWDOWN VALVE INLET PORT 1-D4 E 997804 ADDED ORIFICE. 2015AUG20 A.DHANA Z.WHITLEY
P : SOLENOID VALVE PORT MARKED P/ BLOWDOWN VALVE PILOT PORT 1-D5 REMOVED SPRING SYMBOL IN VALVE, BLOWDOWN
(N.O.)
R : SOLENOID VALVE PORT MARKED R

P
D 12 D

I
19

14

R
A

P
13
37 MANUAL DRAIN VALVE
36 AUTO DRAIN VALVE
35 BALL VALVE
C 19 C
34 SAFETY VALVE
33 RECEIVER, AIR
32 BALL VALVE WITH DEAERATING
5 7
31 CONDENSATE DRAIN VALVE
11*
*POSITION IN CASE OF 30 ONE WAY VALVES WITH STRAINER
NO DRYER OPTION
29 ORIFICE
4
28 FILTER, REFRIGERANT

2
M T 27
26
HIGH PRESSURE SWITCH
CONDENSER

1 6 8
9
10
P 25 REFRIGERANT COMPRESSOR
3 24 HF FILTER
23 CONDENSATE SEPARATOR
22 EVAPORATOR
CONTINUED
21 PRE EXCHANGER
ON SHEET 2
20 GP FILTER
19 ORIFICE
18 FILTER, COOLANT
17 COOLER, OIL
B B
16 THERMOSTAT
15 VALVE, DRAIN
15 14 VALVE, SOLENOID 1SV (LOAD)
13 SCREEN, SCAVENGE
16 12 VALVE, BLOWDOWN (N.O.)
T 11 PRESSURE TRANSDUCER
10 AFTERCOOLER
9 VALVE, MINIMUM PRESSURE
8 ELEMENT, SEPARATOR - FINE
7 VALVE, SAFETY
18 17 6 TANK, SEPARATOR - COARSE
5 TEMPERATURE SENSOR
4 MAIN MOTOR
3 AIR END ASSEMBLY
PIPING LEGEND
2 VALVE, AIR INLET (N.C.)
AIR/COOLANT
1 FILTER, AIR
AIR DIAGRAM
POSITION DESCRIPTION
COOLANT
A KEY TO COMPONENT A
CONDENSATE WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED DO NOT SCALE DRAWING
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
COMPONENT AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO THIRD ANGLE PROJECTION
ASME Y14.5M - 1994
BOUNDARY PROPRIETARY NOTICE DRAWN DATE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, T.RAGHU 2014FEB25
R

REFRIGERANT INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED
CHECKED DATE NAME
GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
S.KRIZEK 2014FEB25
OPTIONAL
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS APPROVED DATE P&ID, R4-11KW
- WELD SYMBOLS TO BE IN ACCORDANCE S.KRIZEK 2014FEB25
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION WITH ANSI/AWS A2.4 &D
P I R
, -11K
4 W

DRAWING TYPE
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS DWG NO.
Process and Instrumentation Diagram SIZE ESTIMATED WEIGHT REVISION
md l.param v
. alu e

EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET (KG UNLESS OTHERWISE SPECIFIED)
INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPYRIGHT @ 2015
Ingersoll Rand
NOMENCLATURE
A1 0.0 kilogram PART NO.
24230070 E
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. SCALE 1.00 MODEL R4 - 11KW SHEET 1 OF 2
Ingersoll-Rand Industrial Technologies ALL RIGHTS RESERVED For Internal Use:24230070|ASSEM|E.0|Dhananjaya A L|20-Aug-15 09:20:00 AM|Open

8 7 6 5 4 3 2 1
20-Aug-2015 12:17:53 (model E.0/E.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.0

7
8 7 6 5 4 3 2 1

DRYER OPTION RECEIVER WITH AUTOMATIC DRAIN OPTION

DRYER

D D

27 34

28
P 26 FROM SHEET 1
33 35

29
36
OPTIONAL
M
11 25
C C
34
32

33
P
35 24 23 22

20 21
RECEIVER WITH MANUAL DRAIN OPTION
FROM SHEET 1

B B
30 34

31

33 35
FROM SHEET 1

37

A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND
IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY
P&ID, R4-11KW P KW
1 & D,
I R4
- 1

RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE


DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 24 230070
PART NO.
24230070 E
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 2 OF 2

8 7 6 5 4 3 2 1
20-Aug-2015 12:17:53 (model E.0/E.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.0

8
92314.01.12

18,57918,579
8 7 6 5 4 3 2 1 826,579

PIPING LEGEND

AIR/COOLANT

AIR
11
COOLANT
23 22 CONDENSATE

D M COMPRESSOR D
ENCLOSURE
SENSOR 50 CHECK VALVE (OIL RETURN)
CONNECTION
49 DRYER HIGH TEMPERTURE SWITCH

OPTIONAL 48 DRYER LOW TEMPERTURE SWITCH


ELECTRONIC NO LOSS CONDENSATE DRAIN
IR SCOPE 47
(MOISTURE SEPARATOR DRYER) ALTERNATE TO ITEM 46.
10 CONDENSATE DRAIN VALVE - 11SV
46
SCOPE BOUNDRY (MOISTURE SEPARATOR DRYER)
ELECTRONIC NO LOSS CONDENSATE DRAIN
45
CUST. SCOPE (HIGH EFFICIENCY FILTER) ALTERNATE TO ITEM 44.

44 CONDENSATE DRAIN VALVE - 10SV


(HIGH EFFICIENCY FILTER)
43 MOISTURE SEPARATOR - DRYER

17 42 REFRIGERANT COMPRESSOR - DRYER


41 DRYER FAN PRESSURE SWITCH
40 DRYER HIGH PRESSURE SWITCH
39 FILTER HIGH EFFICIENCY AIR
38 RECUPERATOR
REFER 28 37 EVAPORATOR
21 SHEET 4
C 36 VALVE HOT GAS BYPASS C
27 16

26
M 25
35
34
CAPILLARY TUBE
FILTER DRYER REFRIGERANT

33 CONDENSER

30
5
14 P 32 PRESSURE TRANSDUCER, AFTERCOOLER - 7APT
(DRYER ONLY)
18 1 31 -----
3 2 1 30 AIR/COOLANT SEPARATOR ELEMENT

13 15 29
ELECTRONIC NO LOSS CONDENSATE DRAIN

20
32 P (MOISTURE SEPARATOR )

9 24 P CUST. AIR
28
27
REMOTE AIR PRESSURE TRANSDUCER - 10APT (OPTIONAL)
FILTER BREATHER (MOTOR SEAL SCAVENGE)
T TREATMENT
26 CHECK VALVE (MOTOR SEAL SCAVENGE)

4
P 25 PRESSURE RELIEF VALVE (OPTION CHINA)
24 PRESSURE TRANSDUCER WET SUMP PRESSURE - 3APT
23 COOLING FAN
22 MOTOR, FAN
21 DRIVE MOTOR
20 TEMPERATURE AIREND DISCHARGE SENSOR - 2ATT
B B
19 OIL TEMPERATURE CONTROL VALVE
12 18 SEPARATOR TANK
29 17 SCAVENGE FILTER / ORIFICE / CHECK VALVE
16 PRESSURE RELIEF VALVE
PRESSURE TRANSDUCER PACKAGE DISCHARGE
15
PRESSURE - 4APT
14 MOISTURE SEPARATOR
8 50
T 13
12
MINIMUM PRESSURE CHECK VALVE
CONDENSATE DRAIN VALVE - 9SV
7 7
11 AIR INLET CHECK VALVE
6 10 LOAD / BLOWDOWN VALVE - 1SV
9 DRAIN VALVE, COOLANT
8 COOLANT FILTER
19
7 CONDENSATE DISCHARGE
6 COOLER, COOLANT
5 COOLER, AIR
4 VACUUM INDICATER
3 AIR FILTER
A 2 COMPRESSOR A
1 AIR DISCHARGE
STANDARD CONTROL SYSTEM DIAGRAM
POSITION DESCRIPTION
KEY TO COMPONENT
636,54 825,54

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P & ID DI
AG R
A M, P& ID 3 -037K W(F S)

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
30-37KW (FS)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 PART NO.
24435588 B
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.
2443 5588

1.00 SHEET 2 OF 4
18,18 18,18
Ingersoll-Rand Industrial Technologies 636,18

8 7 6 5 4 3 2 1
19-Sep-2014 10:47:00 (model B.0/B.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED B.0

9
18,579 18,579
8 7 6 5 4 3 2 1 826,579

PIPING LEGEND

AIR/COOLANT

AIR

COOLANT

CONDENSATE
COMPRESSOR
ENCLOSURE
D SENSOR
D
CONNECTION 52 CHECK VALVE (OIL RETURN)
11
SUB-SYSTEM 51 ORIFICE FOR VACUUM INDICATER
BOUNDRY 50 CHECK VALVE FOR VACUUM TRANSDUCER
23 22 OPTIONAL 49 DRYER HIGH TEMPERTURE SWITCH

IR SCOPE 48 DRYER LOW TEMPERTURE SWITCH


M 47
ELECTRONIC NO LOSS CONDENSATE DRAIN
SCOPE BOUNDRY (MOISTURE SEPARATOR DRYER) ALTERNATE TO ITEM 46.

46 CONDENSATE DRAIN VALVE - 11SV


CUST. SCOPE (MOISTURE SEPARATOR DRYER)
ELECTRONIC NO LOSS CONDENSATE DRAIN
45
(HIGH EFFICIENCY FILTER) ALTERNATE TO ITEM 44.
44 CONDENSATE DRAIN VALVE - 10SV (HIGH EFFICIENCY FILTER)

43 MOISTURE SEPARATOR - DRYER


10
42 REFRIGERANT COMPRESSOR - DRYER
41 DRYER FAN PRESSURE SWITCH
40 DRYER HIGH PRESSURE SWITCH
39 FILTER HIGH EFFICIENCY AIR
38 RECUPERATOR
37 EVAPORATOR
C 31 17 36 VALVE HOT GAS BYPASS C
35 CAPILLARY TUBE

34 FILTER DRYER REFRIGERANT

33 CONDENSER

REFER 32 PRESSURE TRANSDUCER, AFTERCOOLER - 7APT


21 28 (DRYER ONLY)
SHEET 4
31 MODULATION VALVE - 5SV
27

26
M 16
25
30

29
AIR/COOLANT SEPARATOR ELEMENT

ELECTRONIC NO LOSS CONDENSATE DRAIN


(MOISTURE SEPARATOR )

18
30
14 P 28
27
REMOTE AIR PRESSURE TRANSDUCER - 10APT (OPTIONAL)
FILTER BREATHER (MOTOR SEAL SCAVENGE)

3 2 5 1 1 26 CHECK VALVE (MOTOR SEAL SCAVENGE)


25 PRESSURE RELIEF VALVE (OPTION CHINA)
13

20
32 P 15 P CUST. AIR
24
23
PRESSURE TRANSDUCER WET SUMP PRESSURE - 3APT
COOLING FAN

50 9 24 TREATMENT 22 MOTOR, FAN


51
T 21 DRIVE MOTOR

B
P 20
19
TEMPERATURE AIREND DISCHARGE SENSOR - 2ATT
OIL TEMPERATURE CONTROL VALVE
B

18 SEPARATOR TANK
17 SCAVENGE FILTER / ORIFICE / CHECK VALVE
16 PRESSURE RELIEF VALVE
PRESSURE TRANSDUCER PACKAGE DISCHARGE
15
PRESSURE - 4APT
12 14 MOISTURE SEPARATOR
4 13 MINIMUM PRESSURE CHECK VALVE
29
12 CONDENSATE DRAIN VALVE - 9SV
11 AIR INLET CHECK VALVE
10 LOAD / BLOWDOWN VALVE - 1SV
9 DRAIN VALVE, COOLANT

8 52 8 COOLANT FILTER
T 7
7
7 CONDENSATE DISCHARGE
6 COOLER, COOLANT
6 5 COOLER, AIR
4 VACUUM TRANSDUCER (1AVPT)
3 AIR FILTER
A
19 A
2 COMPRESSOR
1 AIR DISCHARGE
DIAGRAM
POSITION DESCRIPTION
KEY TO COMPONENT
636,54 825,54

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P & ID DIAG
KW (FR S)AM
, P & ID 30-37

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


30-37KW (FS)
CONTROL SYSTEM WITH RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION

MODULATION OPTION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 244355 88
PART NO.
24435588 B
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 3 OF 4
18,18 18,18 636,18

8 7 6 5 4 3 2 1
19-Sep-2014 10:47:00 (model B.0/B.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED B.0

10
92314.01.12

18,579 18,579
8 7 6 5 4 3 2 1 826,579

D D

34 33

40 41

35
36
C C

48
M
42
39
38 37
FROM SHEET 2

FROM SHEET 3

49
43

43

B B
46

INTEGRAL DRYER (OPTION)

45 47

A A

636,54 825,54

OPTION OPTION PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P & ID D AI GRAM ,P & ID 30-37KW (FS )

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
30-37KW (FS)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 244355 88
PART NO.
24435588 B
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 4 OF 4
18,18 18,18 636,18

8 7 6 5 4 3 2 1
19-Sep-2014 10:47:00 (model B.0/B.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED B.0

11
92314.08.26

18,579 18,579
8 7 6 5 4 3 2 1 826,579

PIPING LEGEND

AIR/COOLANT
57 CHECK VALVE (OIL RETURN)
AIR 56 DRYER HIGH PRESSURE TEMPERATURE SENSOR (6DTT)
12 55 DRYER DEW POINT TEMPERATURE SENSOR (5DTT)
COOLANT
ELECTRONIC NO LOSS CONDENSATE DRAIN
54
(MOISTURE SEPARATOR DRYER) ALTERNATE TO ITEM 53.
24 23 CONDENSATE
53 CONDENSATE DRAIN VALVE - 11SV
(MOISTURE SEPARATOR DRYER)
COOLING WATER
D M (W.C. ONLY) 52
ELECTRONIC NO LOSS CONDENSATE DRAIN
(HIGH EFFICIENCY FILTER) ALTERNATE TO ITEM 51.
D

51 CONDENSATE DRAIN VALVE - 10SV


COMPRESSOR (HIGH EFFICIENCY FILTER)
ENCLOSURE 50 MOISTURE SEPARATOR - DRYER
SENSOR 49 REFRIGERANT COMPRESSOR - DRYER
CONNECTION 48 FAN PRESSURE SWITCH
SUB-SYSTEM 47 HIGH PRESSURE SAFETY SWITCH
11 BOUNDRY 46 FILTER HIGH EFFICIENCY AIR
45 RECUPERATOR
OPTIONAL
44 EVAPORATOR
IR SCOPE
43 VALVE HOT GAS BYPASS
25
SCOPE BOUNDRY 42 CAPILLARY TUBE

18 41 FILTER DRYER REFRIGERANT


CUST. SCOPE
40 CONDENSER
36
39 PRESSURE TRANSDUCER, AFTERCOOLER - 7APT
(DRYER ONLY)
T 38
37
----
INJECTED COOLANT TEMPERATURE SENSOR - 2CTT
REFER 33
22 SHEET 4
36 PACKAGE DISCHARGE AIR TEMPERATURE SENSOR - 4ATT
C C
35 AIR/COOLANT SEPARATOR ELEMENT
32 17

31
M 30 34
ELECTRONIC NO LOSS CONDENSATE DRAIN
(MOISTURE SEPARATOR - SEE NOTE 2) ALTERNATE TO
ITEM 13.
33 REMOTE AIR PRESSURE TRANSDUCER - 10APT (OPTIONAL)

35
5
15 P 32
31
FILTER BREATHER (MOTOR SEAL SCAVENGE)
CHECK VALVE (MOTOR SEAL SCAVENGE)
19 1
3 2 1 30 PRESSURE RELIEF VALVE (OPTION CHINA)
29 VALVE, AFTERCOOLER TRIM (W.C. ONLY)
14 16
21
39 P 28 WATER SHUTOFF VALVE - 4SV (W.C. ONLY)

V 10 27 P CUST. AIR
27
26
PRESSURE TRANSDUCER WET SUMP PRESSURE - 3APT
COOLING WATER OUTLET (W.C. ONLY)

4 T TREATMENT
25 COOLING WATER INLET (W.C. ONLY)
P 24 COOLING FAN
23 MOTOR, FAN
22 DRIVE MOTOR
21 TEMPERATURE AIREND DISCHARGE SENSOR - 2ATT

37
T 20
19
OIL TEMPERATURE CONTROL VALVE
SEPARATOR TANK
B B
18 SCAVENGE FILTER / ORIFICE / CHECK VALVE
13 17 PRESSURE RELIEF VALVE
34 PRESSURE TRANSDUCER PACKAGE DISCHARGE
16
PRESSURE - 4APT
15 MOISTURE SEPARATOR

P 14
13
MINIMUM PRESSURE CHECK VALVE
CONDENSATE DRAIN VALVE - 9SV (NO DRYER) SEE NOTE 2
9B 8
T 57 12
11
AIR INLET CHECK VALVE
LOAD / BLOWDOWN VALVE - 1SV
7 7
10 DRAIN VALVE, COOLANT
6 9A PRESSURE TRANSDUCER, COOLANT FILTER IN - 5CPT
29
P 20
9B
8
PRESSURE TRANSDUCER, COOLANT FILTER OUT - 6CPT
COOLANT FILTER
9A 26
7 CONDENSATE DISCHARGE
28
6 COOLER, COOLANT
5 COOLER, AIR
4 VACUUM TRANSDUCER (1AVPT)
3 AIR FILTER
A 2 COMPRESSOR A
1 AIR DISCHARGE
STANDARD CONTROL SYSTEM DIAGRAM
POSITION DESCRIPTION
KEY TO COMPONENT
636,54 825,54

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P & ID (AC/WC) D AGRAM
I P
, & ID (AC/WC) 37 7
- 5K W(FSD )

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
37-75 KW (FSD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 23700339
PART NO.
23700339 G
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 2 OF 4
18,18 18,18
Ingersoll-Rand Industrial Technologies 636,18

8 7 6 5 4 3 2 1
19-Sep-2014 10:07:08 (model G.0/G.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED G.0

12
92314.08.26

18,579 18,579
8 7 6 5 4 3 2 1 826,579

PIPING LEGEND
59 CHECK VALVE (OIL RETURN)
AIR/COOLANT 58 ORIFICE FOR VACUUM TRANSDUCER

AIR 57 CHECK VALVE FOR VACUUM TRANSDUCER


56 DRYER HIGH PRESSURE TEMPERATURE SENSOR (6DTT)
COOLANT
55 DRYER DEW POINT TEMPERATURE SENSOR (5DTT)
CONDENSATE ELECTRONIC NO LOSS CONDENSATE DRAIN
54
(MOISTURE SEPARATOR DRYER) ALTERNATE TO ITEM 53.
COOLING WATER
CONDENSATE DRAIN VALVE - 11SV
(W.C. ONLY) 53
(MOISTURE SEPARATOR DRYER)
D D
COMPRESSOR ELECTRONIC NO LOSS CONDENSATE DRAIN
52
ENCLOSURE (HIGH EFFICIENCY FILTER) ALTERNATE TO ITEM 51.
12
51 CONDENSATE DRAIN VALVE - 10SV (HIGH EFFICIENCY FILTER)
SENSOR
CONNECTION 50 MOISTURE SEPARATOR - DRYER
24 23 SUB-SYSTEM 49 REFRIGERANT COMPRESSOR - DRYER
BOUNDRY
48 FAN PRESSURE SWITCH
M OPTIONAL 47 HIGH PRESSURE SAFETY SWITCH
IR SCOPE 46 FILTER HIGH EFFICIENCY AIR

SCOPE BOUNDRY 45 RECUPERATOR


44 EVAPORATOR
CUST. SCOPE
43 VALVE HOT GAS BYPASS

42 CAPILLARY TUBE
11
41 FILTER DRYER REFRIGERANT
25 40 CONDENSER

39 PRESSURE TRANSDUCER, AFTERCOOLER - 7APT


(DRYER ONLY)
38 MODULATION VALVE - 5SV
37 INJECTED COOLANT TEMPERATURE SENSOR - 2CTT
36 PACKAGE DISCHARGE AIR TEMPERATURE SENSOR - 4ATT
C 38 18 C
35 AIR/COOLANT SEPARATOR ELEMENT
ELECTRONIC NO LOSS CONDENSATE DRAIN
34 (MOISTURE SEPARATOR - SEE NOTE 2) ALTERNATE TO
ITEM 13.
33 REMOTE AIR PRESSURE TRANSDUCER - 10APT (OPTIONAL)
REFER 33 32 FILTER BREATHER (MOTOR SEAL SCAVENGE)
22 SHEET 4 31 CHECK VALVE (MOTOR SEAL SCAVENGE)
32

31
M 17
30
30
29
PRESSURE RELIEF VALVE (OPTION CHINA)
VALVE, AFTERCOOLER TRIM (W.C. ONLY)
28 WATER SHUTOFF VALVE - 4SV (W.C. ONLY)

19
35
15 P 27
26
PRESSURE TRANSDUCER WET SUMP PRESSURE - 3APT
COOLING WATER OUTLET (W.C. ONLY)

3 2 5 1 1 25 COOLING WATER INLET (W.C. ONLY)


24 COOLING FAN
14

21
39 P 16 P T 36 CUST. AIR
23
22
MOTOR, FAN
DRIVE MOTOR

57 10 27 TREATMENT 21 TEMPERATURE AIREND DISCHARGE SENSOR - 2ATT


58
T 20 OIL TEMPERATURE CONTROL VALVE

B
P 19
18
SEPARATOR TANK
SCAVENGE FILTER / ORIFICE / CHECK VALVE
B

17 PRESSURE RELIEF VALVE

V 16
PRESSURE TRANSDUCER PACKAGE DISCHARGE
PRESSURE - 4APT
4
37
T 15
14
MOISTURE SEPARATOR
MINIMUM PRESSURE CHECK VALVE
13 13 CONDENSATE DRAIN VALVE - 9SV (NO DRYER) SEE NOTE 2
12 AIR INLET CHECK VALVE
34
11 LOAD / BLOWDOWN VALVE - 1SV
10 DRAIN VALVE, COOLANT

P 9A
9B
PRESSURE TRANSDUCER, COOLANT FILTER IN - 5CPT
PRESSURE TRANSDUCER, COOLANT FILTER OUT - 6CPT
9B 8 8 COOLANT FILTER
T 59 7
7
7 CONDENSATE DISCHARGE
6 COOLER, COOLANT
6 5 COOLER, AIR
29
P 20 26
4
3
VACUUM TRANSDUCER (1AVPT)
AIR FILTER
A 9A 2 COMPRESSOR A
28
1 AIR DISCHARGE
DIAGRAM
POSITION DESCRIPTION
KEY TO COMPONENT
636,54 825,54

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P & ID (AC/WC) D AI GR AM
, P & ID (A
C WC)
/ 37 -75 KW (FSD )

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


37-75 KW (FSD)
CONTROL SYSTEM WITH RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION

MODULATION OPTION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 2370 0339
PART NO.
23700339 G
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 3 OF 4
18,18 18,18 636,18

8 7 6 5 4 3 2 1
19-Sep-2014 10:07:08 (model G.0/G.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED G.0

13
92314.08.26

18,579 18,579
8 7 6 5 4 3 2 1 826,579

D D

41 40

47 48
55
42
43
C C

T
M
49
46
45 44
FROM SHEET 2

FROM SHEET 3

50

51 T

B B
53 56

INTEGRAL DRYER (OPTION)

52 54

A A

636,54 825,54

OPTION OPTION PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P & ID (AC/WC) D AI GRAM ,P & ID (AC/W
C )37-75 KW(FSD )

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
37-75 KW (FSD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 23700 339
PART NO.
23700339 G
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 4 OF 4
18,18 18,18 636,18

8 7 6 5 4 3 2 1
19-Sep-2014 10:07:08 (model G.0/G.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED G.0

14
8 7 6 5 4 3 2 1

PIPING LEGEND

AIR/COOLANT 55 SERVICE VALVE

AIR 54 MODULATION VALVE - 5SV

53 ORIFICE FOR VACUUM TRANSDUCER


COOLANT
52 CHECK VALVE FOR VACUUM TRANSDUCER
CONDENSATE
51 DRYER HIGH PRESSURE TEMPERATURE SENSOR (6DTT)
50 DRYER DEW POINT TEMPERATURE SENSOR (5DTT)
D REFRIGERANT D
ELECTRONIC NO LOSS CONDENSATE DRAIN
COMPRESSOR (MOISTURE SEPARATOR DRYER)
49
(CDV-3 WITH CDE-2 ERROR SINGNAL)
ENCLOSURE ALTERNATE TO ITEM 48.
SUB-SYSTEM 48 CONDENSATE DRAIN VALVE - 11SV
BOUNDRY (MOISTURE SEPARATOR DRYER)
ELECTRONIC NO LOSS CONDENSATE DRAIN
OPTIONAL 47 (HIGH EFFICIENCY FILTER) (CDV-2)
ALTERNATE TO ITEM 46.
IR SCOPE 46 CONDENSATE DRAIN VALVE - 10SV (HIGH EFFICIENCY FILTER)
11
SCOPE BOUNDRY 45 MOISTURE SEPARATOR - DRYER
44 REFRIGERANT COMPRESSOR - DRYER
OPTION WITH CUST. SCOPE
DRYER 43 FAN PRESSURE SWITCH
42 HIGH PRESSURE SAFETY SWITCH
41 FILTER HIGH EFFICIENCY AIR
18 40 RECUPERATOR
REFER
SHEET 4 39 EVAPORATOR
38 VALVE HOT GAS BYPASS

37 CAPILLARY TUBE
22 FILTER DRYER REFRIGERANT
36
30kW
28 29 CONDENSER
C
ONLY
M 17
35

34 PRESSURE TRANSDUCER, AFTERCOOLER - 7APT


(DRYER ONLY)
C
27
33 INJECTED COOLANT TEMPERATURE SENSOR - 2CTT
26
32 PACKAGE DISCHARGE AIR TEMPERATURE SENSOR - 4ATT
IN2 IN1
VN
31
15 OPTION
WITHOUT
DRYER
P 31 AIR/COOLANT SEPARATOR ELEMENT
ELECTRONIC NO LOSS CONDENSATE DRAIN
(MOISTURE SEPARATOR - SEE NOTE 2)
30
(CDV-1 WITH CDE-1 ERROR SINGNAL)
1 1 ALTERNATE TO ITEM 13.
29 REMOTE AIR PRESSURE TRANSDUCER - 10APT (OPTIONAL)
3 5
32 16 28 FILTER BREATHER (MOTOR SEAL SCAVENGE)
12 14
21 19
52 2 10 25
WITH DRYER
ONLY
34
T P CUST. AIR
27
26
CHECK VALVE (MOTOR SEAL SCAVENGE)
PRESSURE RELIEF VALVE (OPTION CHINA)
53
T P
TREATMENT
25 PRESSURE TRANSDUCER WET SUMP PRESSURE - 3APT
P 24 COOLING FAN
23 MOTOR, FAN
22 DRIVE MOTOR
V 21 TEMPERATURE AIREND DISCHARGE SENSOR - 2ATT

4
33
T 20
19
OIL TEMPERATURE CONTROL VALVE WITH CHECK VALVE
SEPARATOR TANK
B B
18 SCAVENGE FILTER / ORIFICE / CHECK VALVE
17 PRESSURE RELIEF VALVE
PRESSURE TRANSDUCER PACKAGE DISCHARGE
16
PRESSURE - 4APT
15 MOISTURE SEPARATOR
13
14 MINIMUM PRESSURE CHECK VALVE

P 24
13 CONDENSATE DRAIN VALVE - 9SV (NO DRYER) SEE NOTE 2

9B T 23 12
11
AIR INLET CHECK VALVE
LOAD / BLOWDOWN VALVE - 1SV
M 10 DRAIN VALVE, COOLANT
9A PRESSURE TRANSDUCER, COOLANT FILTER IN - 5CPT

P 6
7 9B PRESSURE TRANSDUCER, COOLANT FILTER OUT - 6CPT
8 COOLANT FILTER
9A 8
30 7 CONDENSATE DISCHARGE
6 COOLER, COOLANT
20 5 COOLER, AIR
4 VACUUM TRANSDUCER (1AVPT)
3 AIR FILTER
A 2 COMPRESSOR A
1 AIR DISCHARGE
STANDARD CONTROL SYSTEM DIAGRAM
POSITION DESCRIPTION
KEY TO COMPONENT
PROPRIETARY NOTICE NAME
THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P&ID RS30-37IE ,DIA
P&G ID
RRA
M 3 0-
S 37IE(F SD)

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
(FSD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 47531 031001
PART NO.
47531031 001 B
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 2 OF 4
Ingersoll-Rand Industrial Technologies

8 7 6 5 4 3 2 1
10-Mar-2016 04:07:49 (model B.0/B.2)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED B.2

15
8 7 6 5 4 3 2 1

PIPING LEGEND

AIR/COOLANT
55 SERVICE VALVE
AIR 54 MODULATION VALVE - 5SV

COOLANT 53 ORIFICE FOR VACUUM TRANSDUCER


52 CHECK VALVE FOR VACUUM TRANSDUCER
CONDENSATE
51 DRYER HIGH PRESSURE TEMPERATURE SENSOR (6DTT)
REFRIGERANT 50 DRYER DEW POINT TEMPERATURE SENSOR (5DTT)
D D
ELECTRONIC NO LOSS CONDENSATE DRAIN
COMPRESSOR (MOISTURE SEPARATOR DRYER)
ENCLOSURE 49
(CDV-3 WITH CDE-2 ERROR SINGNAL)
ALTERNATE TO ITEM 48.
SUB-SYSTEM CONDENSATE DRAIN VALVE - 11SV
BOUNDRY 48
(MOISTURE SEPARATOR DRYER)
ELECTRONIC NO LOSS CONDENSATE DRAIN
OPTIONAL 47 (HIGH EFFICIENCY FILTER) (CDV-2)
ALTERNATE TO ITEM 46.
IR SCOPE
46 CONDENSATE DRAIN VALVE - 10SV (HIGH EFFICIENCY FILTER)
11 SCOPE BOUNDRY 45 MOISTURE SEPARATOR - DRYER

CUST. SCOPE 44 REFRIGERANT COMPRESSOR - DRYER


OPTION WITH 43 FAN PRESSURE SWITCH
DRYER
42 HIGH PRESSURE SAFETY SWITCH
MN 41 FILTER HIGH EFFICIENCY AIR
40 RECUPERATOR
18 REFER 39 EVAPORATOR
54 SHEET 4
38 VALVE HOT GAS BYPASS

37 CAPILLARY TUBE

30kW 36 FILTER DRYER REFRIGERANT


ONLY 22 28 35 CONDENSER
C 29 C
34 PRESSURE TRANSDUCER, AFTERCOOLER - 7APT

M 17
26
33
(DRYER ONLY)
INJECTED COOLANT TEMPERATURE SENSOR - 2CTT

27 32 PACKAGE DISCHARGE AIR TEMPERATURE SENSOR - 4ATT


IN2 IN1 31 AIR/COOLANT SEPARATOR ELEMENT

VN
31
15 OPTION
WITHOUT
DRYER
P 30
ELECTRONIC NO LOSS CONDENSATE DRAIN
(MOISTURE SEPARATOR - SEE NOTE 2)
(CDV-1 WITH CDE-1 ERROR SINGNAL)
ALTERNATE TO ITEM 13.
1 1 29 REMOTE AIR PRESSURE TRANSDUCER - 10APT (OPTIONAL)
5
3 16 28 FILTER BREATHER (MOTOR SEAL SCAVENGE)
12 14 32
27 CHECK VALVE (MOTOR SEAL SCAVENGE)
21 19
52 2 10 25
WITH DRYER
ONLY
34
T P CUST. AIR
TREATMENT
26 PRESSURE RELIEF VALVE (OPTION CHINA)
53
T P 25 PRESSURE TRANSDUCER WET SUMP PRESSURE - 3APT

P 24
23
COOLING FAN
MOTOR, FAN
22 DRIVE MOTOR

V 21
20
TEMPERATURE AIREND DISCHARGE SENSOR - 2ATT
OIL TEMPERATURE CONTROL VALVE WITH CHECK VALVE
4
B
33
T 19
18
SEPARATOR TANK
SCAVENGE FILTER / ORIFICE / CHECK VALVE
B

17 PRESSURE RELIEF VALVE


PRESSURE TRANSDUCER PACKAGE DISCHARGE
16
PRESSURE - 4APT
15 MOISTURE SEPARATOR
13 14 MINIMUM PRESSURE CHECK VALVE
13 CONDENSATE DRAIN VALVE - 9SV (NO DRYER) SEE NOTE 2

P 24
12 AIR INLET CHECK VALVE

9B T 23 11 LOAD / BLOWDOWN VALVE - 1SV


10 DRAIN VALVE, COOLANT
M 9A PRESSURE TRANSDUCER, COOLANT FILTER IN - 5CPT

P 6
7
9B
8
PRESSURE TRANSDUCER, COOLANT FILTER OUT - 6CPT
COOLANT FILTER
9A 8 7 CONDENSATE DISCHARGE
30 6 COOLER, COOLANT
5 COOLER, AIR
20
4 VACUUM TRANSDUCER (1AVPT)
3 AIR FILTER
A 2 COMPRESSOR A
CONTROL SYSTEM WITH 1 AIR DISCHARGE

MODULATION OPTION DIAGRAM


POSITION DESCRIPTION
KEY TO COMPONENT
PROPRIETARY NOTICE NAME
THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P&ID RS30-37IE DIA
7I
E (FGRA
D
S )M
,P &ID RS 30-3

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
(FSD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 47531 031001
PART NO.
47531031 001 B
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 3 OF 4

8 7 6 5 4 3 2 1
10-Mar-2016 04:07:49 (model B.0/B.2)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED B.2

16
8 7 6 5 4 3 2 1

PIPING LEGEND

AIR/COOLANT

AIR

COOLANT

CONDENSATE

D REFRIGERANT D

COMPRESSOR
ENCLOSURE
FROM SHEET 2
SUB-SYSTEM
BOUNDRY
FROM SHEET 3
OPTIONAL
IR SCOPE

SCOPE BOUNDRY

CUST. SCOPE
55 36 35

42 43

37
38
C C

T
50 M
44
41 40
39
FROM SHEET 2

FROM SHEET 3

45
T

51

B B

46 48

INTEGRAL DRYER (OPTION)

7 7

A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P&ID RS30-37IE D AI GRAM ,P&ID R S30-
37I E(FSD )

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
(FSD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
OPTION 47 OPTION 49 CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
47531031 001 B
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
A1 475 310310 01
PART NO.
SCALE NOMENCLATURE SHEET
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 4 OF 4

8 7 6 5 4 3 2 1
10-Mar-2016 04:07:49 (model B.0/B.2)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED B.2

17
92314.08.26

18,579 18,579
8 7 6 5 4 3 2 1 826,579

PIPING LEGEND
38
AIR/COOLANT
22
AIR
12
M COOLANT

24 CONDENSATE
23 2
COOLING WATER
D M (W.C. ONLY) D
1st 2nd COMPRESSOR
ENCLOSURE
SENSOR
CONNECTION
39 SUB-SYSTEM
BOUNDRY
11
P OPTIONAL
TWO STAGE ONLY
IR SCOPE

SCOPE BOUNDRY
25
18 CUST. SCOPE

36
40 CHECK VALVE (OIL RETURN)
T 39 INTERSTAGE PRESSURE TRANSDUCER
38 INTERSTAGE PRESSURE RELIEF VALVE
22 33 37 TEMPERATURE THERMISTOR OIL INJECTION (2CTT)
C C
36 PACKAGE DISCH AIR TEMP SENSOR (4ATT)
32

31
M 17
30
35
34
AIR/COOLANT SEPARATOR ELEMENT
ELECTRONIC DRAIN TRAP-ALT TO ITEM 13 (SEE NOTE 2)
33 REMOTE AIR PRESSURE TRANSDUCER (10APT) (OPTIONAL)

19
35 15 1
P 32 FILTER BREATHER (MOTOR SEAL SCAVENGE)
31 CHECK VALVE (MOTOR SEAL SCAVENGE)
3 2 5 1 30 PRESSURE RELIEF VALVE (OPTION CHINA)
14 16
29 BALL VALVE (W.C. ONLY) TRIM VALVE
28 WATER SHUTOFF VALVE (W.C. ONLY) (4SV)
V 21
10 27 P CUST. AIR
TREATMENT
27 PRESSURE TRANSDUCER WET SUMP PRESSURE (3APT)

T 26 COOLING WATER OUTLET (W.C. ONLY)


4
P 25
24
COOLING WATER INLET (W.C. ONLY)
COOLING FAN
23 MOTOR, FAN
22 DRIVE MOTOR
21 TEMPERATURE THERMISTOR AIREND DISCHARGE (2ATT)

37
T 20
19
OIL TEMPERATURE CONTROL VALVE
SEPARATOR TANK
B B
13 18 SCAVENGE FILTER / ORIFICE / CHECK VALVE
17 PRESSURE RELIEF VALVE
34
16 PRESSURE TRANSDUCER PACKAGE DISCH. PRESSURE (4APT)
15 MOISTURE SEPARATOR (SEE NOTE 2)

9B
P 14
13
MINIMUM PRESSURE CHECK VALVE
CONDENSATE DRAIN VALVE (9SV) (SEE NOTE 2)
8 40
T 7
12
11
AIR INLET CHECK VALVE
LOAD / BLOWDOWN VALVE (1SV)
7
10 DRAIN VALVE, COOLANT
6 9A PRESSURE TRANSDUCER, COOLANT FILTER IN (5CPT)
29

9A
P 20 26
9B
8
PRESSURE TRANSDUCER, COOLANT FILTER OUT (6CPT)
COOLANT FILTER
7 CONDENSATE DISCHARGE
28
6 COOLER, COOLANT
5 COOLER, AIR
4 VACUUM TRANSDUCER (1AVPT)
3 AIR FILTER
A 2 COMPRESSOR A
1 AIR DISCHARGE
STANDARD CONTROL SYSTEM DIAGRAM
POSITION DESCRIPTION
KEY TO COMPONENT
636,54 825,54

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P & ID (AC/WC) DI AGR A M,
P & ID (AC WC
/ ) 90-1 60KW (F D
S )

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
90-160 KW (FSD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 23371669
PART NO.
23371669 E
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 2 OF 3
18,18 18,18
Ingersoll-Rand Industrial Technologies 636,18

8 7 6 5 4 3 2 1
18-Sep-2014 08:59:01 (model E.0/E.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.0

18
92314.08.26

18,579 18,579
8 7 6 5 4 3 2 1 826,579

PIPING LEGEND
39 AIR/COOLANT

22 AIR

M COOLANT

CONDENSATE
2
COOLING WATER
D (W.C. ONLY) D
12 1st 2nd COMPRESSOR
ENCLOSURE
24 SENSOR
23 CONNECTION
SUB-SYSTEM
M 40 BOUNDRY

P IR SCOPE
OPTIONAL

TWO STAGE ONLY


SCOPE BOUNDRY

11 CUST. SCOPE

25
41 CHECK VALVE (OIL RETURN)
40 INTERSTAGE PRESSURE TRANDUCER
39 INTERSTAGE PRESSURE RELIEF VALVE
38 MODULATION VALVE (5SV)
37 TEMPERATURE THERMISTOR OIL INJECTION (2CTT)
C 38 18 C
36 PACKAGE DISCH AIR TEMP SENSOR (4ATT)
35 AIR/COOLANT SEPARATOR ELEMENT
34 ELECTRONIC DRAIN TRAP-ALT TO ITEM 13 (SEE NOTE 2)
33 REMOTE AIR PRESSURE TRANSDUCER (10APT) (OPTIONAL)
30 33 FILTER BREATHER (MOTOR SEAL SCAVENGE)
22 32
33 31 CHECK VALVE (MOTOR SEAL SCAVENGE)

31
M 17 30
29
PRESSURE RELIEF VALVE (OPTION CHINA)
BALL VALVE (W.C. ONLY)
28 WATER SHUTOFF VALVE (W.C. ONLY) (4SV)

19
35 15
P 27
26
PRESSURE TRANSDUCER WET SUMP PRESSURE (3APT)
COOLING WATER OUTLET (W.C. ONLY)
3 2 5 1 1 25 COOLING WATER INLET (W.C. ONLY)

14 24 COOLING FAN
16 36
23 MOTOR, FAN

V 21
10 27
P T CUST. AIR
TREATMENT
22 DRIVE MOTOR

4 T 21 TEMPERATURE THERMISTOR AIREND DISCHARGE (2ATT)

B
P 20
19
OIL TEMPERATURE CONTROL VALVE
SEPARATOR TANK B
18 SCAVENGE FILTER / ORIFICE / CHECK VALVE
17 PRESSURE RELIEF VALVE
16 PRESSURE TRANSDUCER PACKAGE DISCH. PRESSURE (4APT)

37
T 15
14
MOISTURE SEPARATOR (SEE NOTE 2)
MINIMUM PRESSURE CHECK VALVE
13 13 CONDENSATE DRAIN VALVE (9SV) (SEE NOTE 2)
12 AIR INLET CHECK VALVE
34
11 LOAD / BLOWDOWN VALVE (1SV)
10 DRAIN VALVE, COOLANT

P 9A
9B
PRESSURE TRANSDUCER, COOLANT FILTER IN (5CPT)
PRESSURE TRANSDUCER, COOLANT FILTER OUT (6CPT)
9B
T 41 8 COOLANT FILTER
8 7 7 CONDENSATE DISCHARGE
7
6 COOLER, COOLANT
6 5 COOLER, AIR

P 29 4
3
VACUUM TRANSDUCER (1AVPT)
AIR FILTER
A
9A 20 26 A
2 COMPRESSOR
28
1 AIR DISCHARGE
DIAGRAM
POSITION DESCRIPTION
KEY TO COMPONENT
636,54 825,54

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P & ID (AC/WC) ,D P60
-1 IAG
&KID
RAW
(A(FMC/W
SD)
C )9 0

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


90-160 KW (FSD)
CONTROL SYSTEM WITH RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION

MODULATION OPTION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 23 716
3 69
PART NO.
23371669 E
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 3 OF 3
18,18 18,18 636,18

8 7 6 5 4 3 2 1
18-Sep-2014 08:59:01 (model E.0/E.0)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.0

19
8 7 6 5 4 3 2 1

38 x2

T x8 32
TWO STAGE
46
ONLY 49
22
M
2
47
D 49 24 23
D

48 1st 2nd
M
AC x2
WC x1 50 AMBIENT AIR THERMOSTAT (3ATS) (LOW AMB ONLY)
39
49 EMERGENCY STOP BLOWDOWN MUFFLER (2-STAGE ONLY)
42
200-250kW x1
315-355kW x2 (IN PARALLEL)
P 48
47
EMERGENCY STOP BLOWDOWN VALVE 3 (2-STAGE ONLY)
EMERGENCY STOP BLOWDOWN VALVE 2 (2-STAGE ONLY)
TWO STAGE ONLY
46 EMERGENCY STOP BLOWDOWN VALVE 1 (2-STAGE ONLY)
45 PACKAGE INTAKE AIR TEMP (1ATT)
44 HIGH AIR TEMPERATURE SWITCH (1ATS)
43 CHECK VALVE (COOLANT RETURN)
42 BLOWDOWN VALVE (3SV) (200-250kW x1, 315-355kW x2)
12 18
41 DISCHARGE CHECK VALVE
40 COOLANT STOP VALVE
11 39 INTERSTAGE PRESSURE TRANSDUCER (2APT) (2-STAGE ONLY)

25 38 INTERSTAGE PRESSURE RELIEF VALVE (2-STAGE ONLY)

T x8 37 TEMPERATURE THERMISTOR COOLANT INJECTION (2CTT)


C 33 C
36 PACKAGE DISCH AIR TEMP SENSOR (4ATT)
32 17 x2
22
M 30 x2
35
34
AIR/COOLANT SEPARATOR ELEMENT
ELECTRONIC DRAIN TRAP-ALT TO ITEM 13
33 REMOTE AIR PRESSURE TRANSDUCER (10APT) (OPTIONAL)

19
35 15 1
P 32
31
FILTER BREATHER (MOTOR SEAL SCAVENGE)
COOLANT OUTLET TEMP (3CTT) (VSD A/C AND LOW AMB ONLY)
41
3 5 1 30 PRESSURE RELIEF VALVE (CHINA ONLY)
29 BALL VALVE TRIM VALVE (W.C. ONLY)
2 14 16 36
44 28 WATER SHUTOFF VALVE (W.C. ONLY) (4SV)

45
V
21
27
P T CUST. AIR
TREATMENT
27
26
PRESSURE TRANSDUCER WET SUMP PRESSURE (3APT)
COOLING WATER OUTLET (W.C. ONLY)
10
T 4

T P
25
24
COOLING WATER INLET (W.C. ONLY)
COOLING FAN
23 MOTOR, FAN
40 22 DRIVE MOTOR (2 RTD'S / PHASE, 1 RTD / BEARING)
21 TEMPERATURE THERMISTOR AIREND DISCHARGE (2ATT)
20 COOLANT TEMPERATURE CONTROL VALVE

B 19 SEPARATOR TANK B
18 SCAVENGE FILTER / ORIFICE / CHECK VALVE
13
17 PRESSURE RELIEF VALVE
34

9B
P 16
15
PRESSURE TRANSDUCER PACKAGE DISCH. PRESSURE (4APT)
MOISTURE SEPARATOR
14 MINIMUM PRESSURE CHECK VALVE
13 CONDENSATE DRAIN VALVE (9SV)

37
T 8
T 43
7
12
11
AIR INLET VALVE
LOAD VALVE (1SV)
7 10 DRAIN VALVE, COOLANT
6 9A PRESSURE TRANSDUCER, COOLANT FILTER IN (5CPT)
29 9B PRESSURE TRANSDUCER, COOLANT FILTER OUT (6CPT)

9A
P 20
26
8 COOLANT FILTER
7 CONDENSATE DISCHARGE
28 6 COOLER, COOLANT
50
5 COOLER, AIR
4 VACUUM TRANSDUCER (1AVPT)

A 31
T 3
2
AIR FILTER
COMPRESSOR A
1 AIR DISCHARGE
DIAGRAM
POSITION DESCRIPTION
KEY TO COMPONENT
STANDARD CONTROL SYSTEM PROPRIETARY NOTICE
THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND
NAME
DIAGRAM, P&ID (AC/WC) DI C)
/W AG
RSRA 00
2M
, P&ID
-355KW
(A C

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
RS200-355KW
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 49063217
PART NO.
49063217 B
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 2 OF 4
Ingersoll-Rand Industrial Technologies

8 7 6 5 4 3 2 1
28-Apr-2017 08:35:06 (model B.0/B.3)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED B.3

20
8 7 6 5 4 3 2 1

38 x2
T x8
32

TWO STAGE
ONLY 48
51
24 23
22
M
2
D
50 42
M D

49
AC x2 52 AMBIENT AIR THERMOSTAT (3ATS) (LOW AMB ONLY)
1st 2nd
51 200-250kW x1 WC x1 51 EMERGENCY STOP BLOWDOWN MUFFLER (2-STAGE ONLY)
315-355kW x2 (IN PARALLEL)
50 EMERGENCY STOP BLOWDOWN VALVE 3 (2-STAGE ONLY)
49 EMERGENCY STOP BLOWDOWN VALVE 2 (2-STAGE ONLY)

39 48 EMERGENCY STOP BLOWDOWN VALVE 1 (2-STAGE ONLY)


47 LOAD ISOLATION VALVE (7SV)

12 TWO STAGE ONLY P 46


45
MODULATION VALVE (5SV)
PACKAGE INTAKE AIR TEMP (1ATT)
11 47
25 44 HIGH AIR TEMPERATURE SWITCH (1ATS)
43 CHECK VALVE (COOLANT RETURN)
18 42 BLOWDOWN VALVE (3SV) (200-250kW x1, 315-355kW x2)
46 41 DISCHARGE CHECK VALVE
40 COOLANT STOP VALVE
39 INTERSTAGE PRESSURE TRANSDUCER (2APT) (2-STAGE ONLY)
38 INTERSTAGE PRESSURE RELIEF VALVE (2-STAGE ONLY)
T x8 33 37 TEMPERATURE THERMISTOR COOLANT INJECTION (2CTT)
C 36 PACKAGE DISCH AIR TEMP SENSOR (4ATT) C
32
22
M 17 x2
30 x2
35
34
AIR/COOLANT SEPARATOR ELEMENT
ELECTRONIC DRAIN TRAP-ALT TO ITEM 13
33 REMOTE AIR PRESSURE TRANSDUCER (10APT) (OPTIONAL)

19
35 15 1
P 32
31
FILTER BREATHER (MOTOR SEAL SCAVENGE)
COOLANT OUTLET TEMP (3CTT) (VSD A/C ONLY)
41
3 5 1 30 PRESSURE RELIEF VALVE (CHINA ONLY)

44 29 BALL VALVE TRIM VALVE (W.C. ONLY)


2 14 16 36 28 WATER SHUTOFF VALVE (W.C. ONLY) (4SV)

45
V
21
27 P T CUST. AIR
TREATMENT
27
26
PRESSURE TRANSDUCER WET SUMP PRESSURE (3APT)
COOLING WATER OUTLET (W.C. ONLY)
10
T 4

T P
25
24
COOLING WATER INLET (W.C. ONLY)
COOLING FAN
23 MOTOR, FAN
40 22 DRIVE MOTOR (2 RTD'S / PHASE, 1 RTD / BEARING)
21 TEMPERATURE THERMISTOR AIREND DISCHARGE (2ATT)
20 COOLANT TEMPERATURE CONTROL VALVE
19 SEPARATOR TANK
B 18 SCAVENGE FILTER / ORIFICE / CHECK VALVE
B
13
17 PRESSURE RELIEF VALVE
34

9B
P 16
15
PRESSURE TRANSDUCER PACKAGE DISCH. PRESSURE (4APT)
MOISTURE SEPARATOR
14 MINIMUM PRESSURE CHECK VALVE
13 CONDENSATE DRAIN VALVE (9SV)

37
T 8
T 43
7
12
11
AIR INLET VALVE
LOAD VALVE (1SV)
7 10 DRAIN VALVE, COOLANT
6 9A PRESSURE TRANSDUCER, COOLANT FILTER IN (5CPT)

29 9B PRESSURE TRANSDUCER, COOLANT FILTER OUT (6CPT)

9A
P 20
26
8 COOLANT FILTER
7 CONDENSATE DISCHARGE
28 6 COOLER, COOLANT
52 5 COOLER, AIR
4 VACUUM TRANSDUCER (1AVPT)

31
T 3
2
AIR FILTER
COMPRESSOR
A
A
1 AIR DISCHARGE
DIAGRAM
POSITION DESCRIPTION
KEY TO COMPONENT
CONTROL SYSTEM WITH PROPRIETARY NOTICE NAME

MODULATION OPTION THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET


INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND
IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY
DIAGRAM, P&ID (AC/WC) DI AGRA M,P&ID (AC W
/ C)RS200 355KW
-

RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE


DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
RS200-355KW
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 49063217
PART NO.
49063217 B
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 3 OF 4

8 7 6 5 4 3 2 1
28-Apr-2017 08:35:06 (model B.0/B.3)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED B.3

21
8 7 6 5 4 3 2 1

D D
4
1

C C

T
5
9
6

T
7

B B

2
9 COOLING WATER OUTLET (ERS)
8 COOLING WATER INLET (ERS)
7 COOLANT TEMPERATURE CONTROL VALVE (ERS)
6 COOLER, COOLANT (ERS)
5 COOLANT TEMPERATURE CONTROL VALVE (PACKAGE)
4 SYSTEM, SEPARATION (PRIMARY/SECONDARY)
3 FILTER, COOLANT
2 COOLER, COOLANT (PACKAGE)
1 COMPRESSOR

A # DESCRIPTION A
KEY TO COMPONENT

AIR COOLED WITH OPTIONAL ENERGY RECOVERY SYSTEM CONFIGURATION PROPRIETARY NOTICE NAME
THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND DIAGRAM, P&ID (AC/WC) D AG
I R AM,P& DI ( AC/W C)RS 2 003- 55K W

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
RS200-355KW
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 49063217
PART NO.
49063217 B
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 4 OF 4

8 7 6 5 4 3 2 1
28-Apr-2017 08:35:06 (model B.0/B.3)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED B.3

22
20507.09.49

23
20507 09.48
20507.09 48

24
RELEASED 20/Sep/2017 12:52:12 GMT

8 7 6 5 4 3 2 1
REVISIONS
ZONE REV ECN DESCRIPTION DATE DRAWN APPROVED

A 1265371 CANCELLED REVISION A 2017AUG28 B.SHASHANK C.FRAZIER


B ORIGINAL RELEASE 2017SEP14 B.SHASHANK C.FRAZIER
(SINGLE PHASE MOTOR MAINTENANCE INDICATOR OPTION DRYER OPTION CUSTOMER SUPPLIED
CONNECTION OPTION) (INSTEAD OF STANDARD HOUR METER) 115V/1 /60HZ
TO SUPPLY 1Mb
1M OL-A
(THREE PHASE MOTOR T1 1 7 4 2L 1L L
TO SUPPLY L1 L2
CONNECTION OPTION)
L1 L2 L3 3FU

1M MTR2 N
D 1M OL-B D
OL-A T2 P8 P7 P6 P5
T1
1N 4FU
HM1
1M OL-B MTR1
T2 P4 P3 P2 P1
MTR1 PE
1M OL-C
T3
1M OL-C
T3
2
1 2
F F
U U

CPT { SEE TRANSFORMER NAMEPLATE FOR


WIRING CONNECTION REQUIREMENTS.
CPT
LEGEND

TRANSFORMER, CONTROL 120/1/50-60


X1 X2 CR RELAY, CONTROL
CRa CONTACT, CONTROL RELAY
EDV VALVE, ELECTRIC DRAIN 120/1/50-60
C MCB1 C
ES EMERGENCY STOP
HATS HIGH AIR TEMP SHUTDOWN
1 HM METER, ELAPSED TIME
1 TDR HM1 MAINTENANCE INDICATOR
TDRa PR-1b (A1) (A2)
13 LT1 LIGHT, POWER ON INDICATOR (GREEN)
9
(15) (18) PORO LT2 LIGHT, AUTO RESTART INDICATOR (YELLOW)
PR-1a (31) (32)
M COIL, MOTOR STARTER
(31) (34) MTR1 MAIN MOTOR
ES
MTR2 DRYER MOTOR
OL OVERLOAD, MOTOR STARTER
PR PORO ALARM
9 (A1) (A2)
LT1 PR RELAY, PORO
PR-1a RELAY, PORO CONTACT
1 G 2
PR-1b RELAY, PORO CONTACT
PORO OPTION
HM PR-2a RELAY, PORO CONTACT
PR-2b
P1 PR-2b RELAY, PORO CONTACT
P2
ST (21) (22) PS SWITCH, PRESSURE
OL P3
HATS ST PUSH BUTTON, START
PR-2a
B 3 4 5 6 11 TRa 7 TDR RELAY, TIME DELAY (PORO - 10 SEC.) B
M
(21) (24) (15) (16) TDRa CONTACT, TIME DELAY RELAY
EDV TR RELAY, RUN ON (6 MIN.)
2
EDV OPTION TRa CONTACT, RUN ON RELAY
CRa
6 1FU, 2FU FUSE, PRIMARY
CR
(21) (24) (A1) (A2) 3FU, 4FU FUSE, DRYER
12 1M CONTACTOR, MAIN
TR 1Ma, 1Mb CONTACT, AUX. STARTER
(A1) (A2)
1Ma LT2 1SV SOL, LOAD
PS 3SV SOL, BLOW DOWN
Y
6 8 MCB1 CIRCUIT BREAKER
10 1SV

10 3SV
10
2

47618055001 B

A A
WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED DO NOT SCALE DRAWING
NOTES : BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO THIRD ANGLE PROJECTION
PROPRIETARY NOTICE ASME Y14.5M - 1994 DRAWN DATE
1. DECAL MUST CONFORM TO THE LATEST REVISION OF I-R SPECIFICATION 92-8.95. THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, B.SHASHANK 2017SEP14
R

INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE NAME

2. CIRCUIT SHOWN IN NORMAL POSITION DE-ENERGIZED.


GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS
B.NARENDRA
APPROVED
2017SEP14
DATE
DECAL, ELECT. SCHEMATIC
3. ALL WIRING TO BE MARKED IN ACCORDANCE WITH THIS SCHEMATIC.
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS
- WELD SYMBOLS TO BE IN ACCORDANCE
WITH ANSI/AWS A2.4
C.H.FRAZIER 2017SEP14
DRAWING TYPE
UP6 5-15HP 1PH & 3PH DOL (N.A.) D EL
L,
TICCE U
PA
E T65-1
CS. H
5C HE
PP1AMH &3
P H DO
L (N A.)
.

SIZE ESTIMATED WEIGHT DWG NO. REVISION


EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET Detail Drawing

4. ALL WIRING TO BE IN ACCORDANCE WITH NEC. INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPYRIGHT @ 2017
Ingersoll Rand
NOMENCLATURE
A1 - 47618055 001 B
(KG UNLESS OTHERWISE SPECIFIED)

47618055 001

PART NO.
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. SCALE MODEL SHEET
ALL RIGHTS RESERVED 0.25 UP-SERIES 5-15HP 1 OF 1
For Internal Use : Model = 47618055001 | PART | B.1 | Shashank Burli | 14-Sep-17 05:22:28 PM | Design Drawing = 47618055001 | DRAW | B.2 | Shashank Burli | 14-Sep-17 05:22:28 PM | Design

8 7 6 5 4 3 2 1
14-Sep-2017 05:22:42 (model B.1/B.2)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED B.2

25
8 7 6 5 4 3 2 1
REVISIONS
ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

C.H.FRAZIER
A 82594 ORIGINAL RELEASE 2014APR01 M.CURRY
T.VINCENT
BC34 B 83085 ADD 2L, 1L, L, 1N, N, PE WIRE LABELS TO DRYER 2014SEP04 K.CODY C.H.FRAZIER
OPTION
C 1268243 NAME WAS DECAL, ELECT. SCHEMATIC UP6 5-15HP 2017SEP14 A.DHANA C.FRAZIER
DOL THREE PHASE.
TO SUPPLY

L1 L2 L3

D 1M OL-A D
T1
MAINTENANCE INDICATOR OPTION
(INSTEAD OF STANDARD HOUR METER)
1M OL-B
T2
MTR1 1 7 4
1M OL-C
T3

1 2 P8 P7 P6 P5
F F
U U HM1
P4 P3 P2 P1 LEGEND

CPT TRANSFORMER, CONTROL 120/1/50-60


CR RELAY, CONTROL
CPT { SEE TRANSFORMER NAMEPLATE FOR
WIRING CONNECTION REQUIREMENTS.
2 CRa
EDV
CONTACT, CONTROL RELAY
VALVE, ELECTRIC DRAIN 120/1/50-60
X1 X2
ES EMERGENCY STOP
HATS HIGH AIR TEMP SHUTDOWN
3 HM METER, ELAPSED TIME
C F C
U HM1 MAINTENANCE INDICATOR
LT1 LIGHT, POWER ON INDICATOR (GREEN)
1 LT2 LIGHT, AUTO RESTART INDICATOR (YELLOW)
1 TDR DRYER OPTION M COIL, MOTOR STARTER
TDRa PR-1b (A1) (A2) CUSTOMER SUPPLIED
9 13 1Mb 115V/1 /60HZ MTR1 MAIN MOTOR
(15) (18) PORO 4FU MTR2 DRYER MOTOR
PR-1a (11) (12) 2L 1L L
OL OVERLOAD, MOTOR STARTER
(11) (14) PORO ALARM
ES
N
PR RELAY, PORO
MTR2
PR-1a RELAY, PORO CONTACT
PR 5FU
(A1) (A2) 1N PR-1b RELAY, PORO CONTACT
9
LT1 PR-2a RELAY, PORO CONTACT
1 G 2 PE PR-2b RELAY, PORO CONTACT
PS SWITCH, PRESSURE
PORO OPTION
PR-2b HM ST PUSH BUTTON, START
P1 TDR RELAY, TIME DELAY (PORO - 10 SEC.)
P2
ST (21) (22) TDRa CONTACT, TIME DELAY RELAY
OL P3
HATS TR RELAY, RUN ON (6 MIN.)
PR-2a
B 3 4 5 6 11 TRa 7 B
M TRa CONTACT, RUN ON RELAY
(21) (24) (15) (16)
1FU, 2FU FUSE, PRIMARY
EDV 3FU FUSE, SECONDARY
CRa EDV OPTION 4FU, 5FU FUSE, DRYER
6 1M CONTACTOR, MAIN
CR
(A1) (A2) 1Ma, 1Mb CONTACT, AUX. STARTER
12 1SV SOL, LOAD
TR
(A1) (A2) 3SV SOL, BLOW DOWN
1Ma LT2
PS
Y
6 8 2
10 1SV

3SV 2
10
2

24771099 C

A A
WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED DO NOT SCALE DRAWING
NOTES : BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO THIRD ANGLE PROJECTION
PROPRIETARY NOTICE ASME Y14.5M - 1994 DRAWN DATE
1. DECAL MUST CONFORM TO THE LATEST REVISION OF I-R SPECIFICATION 92-8.95. THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, P.SADASHIV 2011OCT11
R

INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE NAME

2. CIRCUIT SHOWN IN NORMAL POSITION DE-ENERGIZED.


GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS
C.H.FRAZIER
APPROVED
2014APR01
DATE
DECAL, ELECT. SCHEMATIC UP6
3. ALL WIRING TO BE MARKED IN ACCORDANCE WITH THIS SCHEMATIC.
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS
- WELD SYMBOLS TO BE IN ACCORDANCE
WITH ANSI/AWS A2.4
T.VINCENT 2014APR01
DRAWING TYPE
5-15HP DOL THREE PHASE (A.P.) .DEC
TSC HEMATI
L,AE EL C
C U P6 5 1- 5 H DP OL TH E
RE H
P ASEA
( P
. ).

SIZE ESTIMATED WEIGHT DWG NO. REVISION


EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET Detail Drawing

4. ALL WIRING TO BE IN ACCORDANCE WITH NEC. INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPYRIGHT @ 2017
Ingersoll Rand
NOMENCLATURE
24771099
(KG UNLESS OTHERWISE SPECIFIED)

A1 0.0 kilogram C 24771099

PART NO.
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. SCALE MODEL SHEET
Ingersoll-Rand Industrial Technologies ALL RIGHTS RESERVED 0.25 UP-SERIES 5-15HP 1 OF 1
For Internal Use : Model = 24771099 | PART | C.0 | B M Vinay | 21-Aug-17 05:04:21 PM | Open Drawing = 24771099 | DRAW | C.1 | Dhananjaya A L | 14-Sep-17 11:14:47 AM | Open

8 7 6 5 4 3 2 1
15-Sep-2017 04:21:08 (model C.0/C.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED C.1

26
27
120606.15.51

28
52805.01.23

29
52805.01.20

30
52805.01.23

31
8 7 6 5 4 3 2 1
REVISIONS
ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

A 82169 ORIGINAL RELEASE 2013OCT31 M.WAGENHAUSER S.EATON


B 83576 FB1 WAS MCB1 2015APR21 M.WAGENHAUSER S.EATON
MODEL NOMENCLATURE WAS
Xe-70M "UP6 20-30HP / UP5 15-22KW"
MCB2 REVISED WIRE NUMBERS ON SHEET 2:
AGND 2
L1 L2 L3 T1 2131 1xx - 1xxx WAS 100 - 199

X13
H1:575V 24V
1 + 2xx - 2xxx WAS 200 - 299

X01
H2:460V 2132 ANA- 3xx - 3xxx WAS 300 - 399
0V
2 - OUT 1
H3:415V C 83810 DELETED MODULATION (5SV AND 2015AUG24 M.WAGENHAUSER B.WARREN
NOTE 2 6SV) FROM SCHEMATIC
H4:380V ES-1 2021
MCB3 D 1500662 ADDED MODULATION (5SV, 6SV, K1) 2015SEP09 M.WAGENHAUSER B.WARREN
101 102 1091 DI8 9 MODEL WAS "UP6S 20-30HP /
H5:230V
FB1 X1:115V
1 C-R UP5S 15-22KW"
D 3L3 H6:220V DI7 8 D
PE RSP 1-B8 E 1243523 ADDED CURRENT SENSOR 2017JUN14 V.NAVEEN C.TOLER
KM1-1 2027 2021 APPLICATION CHART AND NOTE.
150 118 1092 DI6 7
3L1 H7:0V X3:0V 1-A2 DRAWING TYPE WAS DETAILED
A2 KM1 A1 2 R1 2026 RST 2021 DRAWING
MM KM3-1 DI5 6

X09
RC3
119 KM3-2 2025 2021
0V EDV A2 KM2 A1 DI4 5

X02
T1 2024 2021
L3 120 KM2-1 1093 DI3 4
Xe-70M A2 KM3 A1 3 R2 2023 JUMPER 2021
L2 DI2 3
1SV
L1 2022 ES-2
3SV 4 R3 DI1 2
5SV L1 L2 L3 L1 L2 L3 2021
C-DI 1
6SV K1 1 C-R
CAB KM1 KM2 KM3 RC1
BP 2036 WHI
150 1SV 2 R4 AN3 6
DOOR 2035 BLK 2ATT
1082 C-ANA3 5 T
SEP
NOTE 5 3SV 2034 WHI
BASE AN2 4

X08
4APT

X03
2033 RED P
C-ANA2 3
RC2 1083
150 2032 WHI
5SV 3 R5 AN1 2
2031 RED 3APT
C-ANA1 1 P
6SV
CT1,2,3
AN4 2
C 4 R6 C

X15
K1 C-ANA4 1
U1 V1 W1 U1 V1 W1 U1 V1 W1
1 C-R

PORO 1072
V1 V3
150 L2- 2 RS485
U3 W1 2 R7
AIRBUS/

X04
X07
U1 W3 U3
W3
L1+ 1 MODBUS RTU
U2 3073
MM V3
MM MM
3 C-R
U2 W4 V2 W2
CTO L2- 2 RS485
U4 W2
(N/O) 3074

X05
V2 V4 UNUSED
4 R8 L1+ 1
U4 V4 W4 U4 V4 W4 U2 V2 W2
220
208-230 Volts 460 Volts 380 CT1
400 1 a

X14
X11
550
CT1
575 2 b
Volts
CT1
3 c
VERIFY ACTUAL MOTOR CONNECTIONS WITH MOTOR SCHEMATIC
CT2

X10
1 a
CT2
CURRENT SENSOR APPLICATION CHART 2 CCT

STARTER ASSY APPLICATIONS USE CT CT RATING


30HP 208-230V
B 24694697 24739559 100 B
22KW 220V 50HZ
(NOTE 1)
30HP 460V 24741787 40
15-20HP 208-230/460V
24748618 25HP 460V 15-30HP 575V 24741787 40
303
(NOTE 1) 15-18KW 220V 50HZ
MOTOR
2HP 208/230V 24739559 100 RUNNING KM1-2
25/30HP 380V 60HZ, CONTACT
24748634 11KW 220V 50HZ, 24741787 40 304
18-22KW 380-400V 50HZ
15-20HP 380V 60HZ,
24748642 24741787 40
11-15KW 380-400V
NOTE: THESE STARTER PANELS ARE SUPPLIED WITH TWO SETS OF CTs - MOUNT
AND WIRE THE APPRORIATE SIZE FOR THE APPLICATION - SEE TABLE.
THE SECOND SET OF CTs ARE TO BE MOUNTED ON THE MOTOR WIRES, AND THE
SENSOR WIRES ARE TO BE SECURED WITH CABLE WRAPS. THE INTENT OF THE SECOND
SET OF CTs IS TO SUPPORT POSSIBLE FIELD CONVERSION OF THESE PACKAGES. 48775233 REV E
SHEET 1 OF 2

A A
WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED DO NOT SCALE DRAWING
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO THIRD ANGLE PROJECTION
PROPRIETARY NOTICE ASME Y14.5M - 1994 DRAWN DATE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, M.WAGENHAUSER 2013OCT31
R

NOTES: INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE NAME
GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
1. DECAL MUST CONFORM TO THE LATEST REVISION OF IR SPECIFICATION 92-8.95.
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS
M.CAIN
APPROVED
2013OCT31
DATE
SCHEMATIC, ELECTRICAL DIAGRAM,
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS
- WELD SYMBOLS TO BE IN ACCORDANCE
WITH ANSI/AWS A2.4
S.EATON 2013OCT31
DRAWING TYPE
Xe-70M (FS-SD) C H MATI
S E C E, LECRT CAL
I D AI GR M,
A X e-70M F
( -SD
S )

SIZE ESTIMATED WEIGHT DWG NO. REVISION


EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET Schematic Diagram
INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPYRIGHT @ 2017
Ingersoll Rand
NOMENCLATURE
A1 0.0 kilogram 48775233
(KG UNLESS OTHERWISE SPECIFIED)

E 48775233

PART NO.
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. SCALE MODEL SHEET
ALL RIGHTS RESERVED 1.00 UP6S 15-30HP / UP5S 11-22KW 1 OF 2
For Internal Use:Model=48775233|PART|E.2|Sanjeeth Devadatta|22-Jun-17 10:51:14 AM|Design<>Drawing=48775233|DRAW|E.4|Sanjeeth Devadatta|22-Jun-17 10:51:14 AM|Design

8 7 6 5 4 3 2 1
22-Jun-2017 10:55:51 (model E.2/E.4)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.4

32
8 7 6 5 4 3 2 1

X1
D L 1 2 L1 D
CUSTOMER

X1
N 4 5 N1 1
SUPPLIED
2

L6
POWER PE 1S1

N2
L2

N3
L3
P

N10
1P2
8 2 6 2

L4
K1
K1

N6
L7
TEMP
LEGEND 6 4 8 4
LABEL DESCRIPTION 1V1

X1
P
0V ZERO VOLTAGE 1P1

N5
L5
N5
4

L5
1SV LOAD VALVE

L8
2ATT AIREND DISCHARGE TEMPERATURE

BLACK
BLUE
3APT WET SUMP PRESSURE A2

3SV BLOWDOWN VALVE

X1
2 3 1 K1
4APT PACKAGE DISCHARGE PRESSURE A1

5SV MODULATION VALVE 3

L9
6SV MODULATION VALVE 1M2
BASE BASE PLATE M
BP BACKPANEL
1~
CAB CABINET T
C CTO COMMON TRIP OUTPUT CB C
TH DRYER FAN
CTx CURRENT SENSORS MOTOR
EDV ELECTRONIC DRAIN VALVE
ES EMERGENCY STOP BUTTON L10
FBx FUSE BLOCK
MCBx CIRCUIT BREAKERS
K1 CONTROL RELAY PCP
KM1 MAIN CONTACTOR
S R C S C R
KM2 DELTA CONTACTOR
KM3 START CONTACTOR
DRYER LEGEND
MM MAIN MOTOR LABEL DESCRIPTION
PE PROTECTED EARTH 1M1 COMPRESSOR MOTOR
M M 1M2 FAN MOTOR
PORO POWER OUTAGE RESTART OPTION 1M1 1M1
RCx ARC SUPPRESSOR 1P1 HIGH PRESSURE SWITCH
1~ 1~
RSP REMOTE STOP 1P2 FAN PRESSURE SWITCH
RST REMOTE START DRYER DRYER 1S1 MAIN POWER SWITCH
SEP SEPARATOR TANK MOTOR MOTOR 1V1 CONDENSATE DRAIN VALVE
T1 CONTROL POWER TRANSFORMER CB COMPRESSOR BOX
K1 COMPRESSOR CONTACTOR
230V/1~/50HZ 115V/1~/60HZ
PCP THERMAL PROTECTION
PE PROTECTED EARTH
TH THERMOSTAT SWITCH

B
DRYER OPTION B

WIRE COLOR LEGEND WIRE DESIGNATION LEGEND


NOTES: LABEL DESCRIPTION NUMBERS FUNCTION WIRE COLOR-EU STD WIRE COLOR-UL STD WIRE SIZE
BLK BLACK 1 - 99 POWER BLACK BLACK A/R
1. APPROVED FUSED DISCONNECT OR CIRCUIT BREAKER PER LOCAL ELECTRICAL CODES BLU BLUE 1xx - 1xxx AC CONTROL RED RED 2
18 AWG (1mm )
MUST BE PROVIDED BY THE CUSTOMER. BRO BROWN 1xx - 1xxx GROUNDED AC GREEN / YELLOW WHITE 2
18 AWG (1mm )
GRE GREEN
2. REMOVE JUMPER(S) FOR CUSTOMER-SUPPLIED PHASE MONITOR (OR OTHER SAFETY COMPONENTS). 2xx - 2xxx DC CONTROL BLUE BLUE 2
18 AWG (1mm )
PIN PINK
3xx - 3xxx AUXILIARY RED / BLUE / BLACK ORANGE 2
3. INDICATES OPTIONAL COMPONENTS. 18 AWG (1mm )
RED RED
400-499 AC POWER ORANGE RED 2
VIO VIOLET 18 AWG (1mm )
4. INDICATES OPTIONAL FIELD WIRED COMPONENTS. GND GROUNDED GREEN / YELLOW GREEN / YELLOW A/R
WHI WHITE
5. SEPARATOR TANK & BASE PLATE GROUND TO USE 12 AWG GREEN WIRE. YEL YELLOW

A A
48775233 REV E
SHEET 2 OF 2

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND
IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY
SCHEMATIC, ELECTRICAL DIAGRAM, SC HEMATC,IE LEC TRCAL
I DIAG
RAM ,Xe-70 M(FS-SD )

RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE


DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
Xe-70M (FS-SD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 4 877
5 233
PART NO.
48775233 E
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 2 OF 2

8 7 6 5 4 3 2 1
22-Jun-2017 10:55:51 (model E.2/E.4)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.4

33
34
35
36
37
38
39
40
8 7 6 5 4 3 2 1
REVISIONS
ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

A 81140 ORIGINAL RELEASE 2012OCT24 C.LEAMON B.WARREN


1-C5 B 81597 ADDED RC4, 10SV & 11SV 2013MAR07 C.LEAMON B.WARREN
1-C6 REMOVED DRYER RUN SIGNAL
2012 1-C7 REMOVED FU7, 8, 9
Xe-70M ANA- WHI REMOVED KM1-1
1
MCB2 OUT 1-D4 ADDED TERMINALS TO 2028, 2029 & 2X ON 2021

X01
L1 L2 L3 ALTERNATE 575V T1 24V
1130 1131 ZNR 2011 2-D7 REMOVED WIRE NUMBER DESIGNATION LEGEND
1 + 3-C3 ADDED K3, K4 & ETC

X13
FU10,11 460V
1132 AGND 2
0V BLK 3-B8 L1, L2, L3 WAS 6L1, 6L2, 6L3
L3 3L3 440V 2 - L1, L2, L3 WAS FU 7, 8, 9
400V
ES-1 NOTE 2 1-C7 C 13-00486 REMOVED FR1. 2013MAR07 C.LEAMON B.WARREN
L1 3L1
PE
380V
100 MCB3 101 102 1091 2029 DPS 2-C8 REMOVED FR1 IN LEGEND.
MCB1 230V 115V
1 C-R DI8 9 2-B8 ADDED 9,10,11SV IN LEGEND.
D 3L3 2028 DFW 1-C4 CABLE 2031,2041 IS RED COLOR WAS BLACK. D
KM1-1 DI7 8 3-B3 ADDED TERMINAL 20,21,22,23,24,25,26,27,28.
FM 150 118 1092 RSP
3L1 0V 0V 2027 3-B4 CONNECTED TERMINAL 14 TO
MM A2 KM1 A1 2 R1 DI6 7 CABLE NUM-110, WAS 13
RC4 KM3-1 2026 RST 3-B CHANGE DRYER CABLE NUMBER
OV 119 KM3-2 DI5 6

X09
A2 KM2 A1 ACCORDING TO COMPRESSOR CABLE.
T1 9SV 2025 RLU

X02
DI4 5 1-B5 ADDED 500,501,502,503 NUMBER FOR C.T CABLE.
EB ALTERNATE
Xe-70M L3 120 KM2-1 1093 2024 RLE
2-C3 ADDED CT CABLE PINK COLOR CABLE.
1SV A2 KM3 A1 3 R2 DI3 4 2023 2021 1-B7 FD ALARM 2023 WAS 2023A.
L2 2023 FMP-1 2021 1-D3 FD FEEDBACK 2023 WAS 2023A.
5SV L1 1094 DI2 3 3-C3 K6-1 IS N.C WAS N.O 2013AGU19 FN JR ZHONG.XH
ALTERNATE FD
9SV
A2 KM4 A1 4 R3 2022 ES-2 3-C6 ADD K6-2.
L1 L2 L3 L1 L2 L3 DI1 2 1-D6 D 14-00009 ADD. OPTION FOR 10SV,11SV. 2014MAR25 FN JR ZHONG.XH
10SV 150 1091 2021 1-C5 ADD. OPTION FOR PORO.
11SV CDV1
1 C-R C-DI 1 1-C3 ADD. SPT.
KL1

CAB TO:
1.3 1.2 1.1
RC1 1082 2-B8 ADD. SPT TO TABLE.
DRYER CDV2 2036 WHI 2-B5 REMOVE K5 RELAY.
BP KL1 1SV 2 R4 AN3 6 3-B7 ADD DRYER OPTION 575V60HZ OR 380V60HZ UNIT.
POWER 1.3 1.2 1.1
150 2035 BLK 2ATT
DOOR
CDV3
C-ANA3 5 T 2-C6 ADD NOTE 9.
FD KL1
2034 WHI 1-D8 E 1004783 ADDED DRYER POWER CONNECTION 2016JAN13 C. LEAMON B. WARREN

X08
1.1
1.3 1.2 AN2 4 1-D7 1130 WAS 24V, 1131 WAS 2131, 1132 WAS 1232

X03
RC2 1083 2033 RED 4APT 1-C5 3074 WAS 3072
NOTE3 C-ANA2 3 P 1-C4 2151 WAS 2041, 2152 WAS 2042
5SV 3 R5
1-D4 REMOVED TERMINALS 2021-2029, ADDED 2011, 2012
150 2032 WHI
AN1 2 2-D4 CHANGED TITLE OF DETAIL B TO ADD "200V"
FMP 2031 RED 3APT 2-D3 REPLACED KM4 WITH FU1,2,3
KM2 KM3 1084 C-ANA1 1 P 3 REMOVED TERMINALS, 100 WAS 101
I> I> I> KM1 A2 K5 A1 4 R6
3-C7 F 1033450 CHANGE U,V,W TO U3,V3,W3 ON CABLE LEAD 2016MAR22 FN JR ZHONG.XH
RC3 OF DRYER MOTOR.
2L1 2L2 2L3 2042 WHI 4ATT CHANGE U,V,W TO U3,V3,W3 ON CABLE LEAD
2

X015
AN4
KM4 2041 RED OR OF DRYER FAN MOTOR
C-ANA4 1 7APT 1-B6 G 1090461 MAIN MOTOR WIRING IS FOR 12 LEAD, 2016AUG22 FN JR ZHONG.XH
V1 W1 W2 U2 V2
U V W 1 C-R WAS 6 LEADS, MARKER "U V W"
C 1072
ADD A OPTION: MAIN MOTOR WIRING IS C
150 PORO L2- 2 RS485 FOR 12 LEAD. MARKER "T"

X04
2 R7 AIRBUS/ 2-C6 ADD NOTE 10,11,12.
FM1
L1+ 1 MODBUS RTU 2-B6 H 1147562 ADDED ODM OPTION 2016NOV02 FN JR ZHONG.XH

X07
CT1,2,3 (OPTION)
3073 RS485 2-C6 ADDED NOTE 13, 14, 15
SPT 2-B2 ADDED NOT 14 FOR IVH
3 C-R
2051
CTO Pin7 1-C3 J 1149496 ADDED NOTE 16 2016DEC22 FN JR ZHONG.XH
3072 L2- 2 2-B4 ADDED RELAY K2 AND CONTACT K2-1 & K2-2

X05
(N/O) 2052 Pin8 2-D3 K CHANGED WIRE DESIGNATION LEGEND
U1 V1 W1 W2 U2 V2
4 R8 L1+ 1 2-B3 REDUCED OSH QUANTITY TO 1 WAS 3
U5 V5 W5 W6 U6 V6
NOTE 10
Pin5 D4 L 1209494 SWAPPED ANA-OUT AND AGND POSITION 2017MAR13 C.LEAMON B. WARREN
LOW
U1 V1 W1 W6 U6 V6 NOTE 11 503
AMBIENT 1
CT1
FU1, 2, 3 a
U1 V1 W1 W2 U2 V2 NOTE 12 502

X11
CT1
2 b

X14
2L1 2L2 2L3 U2
501 CT1
V2 3
KM4 MM c
W2
4L1 4L2 4L3 CT2
1 a

X10
W5 V5 U5 500
L1 L2 L3 CT2
2 CCT
GND NOTE 11
PE
K5-1 TRM
283
12
284
18
285
27
FD 2021 BLU T1 T2 T3 T6 T4 T5
01 T7 T8 T9 T12 T10 T11 NOTE 10 303
B 2023 BLU B
02 MOTOR
2012 T1 T2 T3 T12 T10 T11 NOTE 11
2012 WHI RUNNING KM1-2
60
2011 T1 T2 T3 T6 T4 T5 NOTE 12 CONTACT
2011 BLK
55 T4 304
CAP
PE T5
MM
T6
U V W
U W V T9 T8 T7
NOTE 11
FM DETAIL A TRM
NOTE 6

NOTES :

1. DECAL MUST CONFORM TO THE LATEST 24276602 REV. L


REVISION OF I-R SECIFICATION 92-8.95. SHEET 1 OF 3

A A
WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED DO NOT SCALE DRAWING
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO THIRD ANGLE PROJECTION
PROPRIETARY NOTICE ASME Y14.5M - 1994 DRAWN DATE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, JR.FAN 2014.03.25
R

INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE NAME
GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS
WILLIE.ZHONG
APPROVED
2014.03.25
DATE
SCHEMATIC, ELECTRICAL
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS
- WELD SYMBOLS TO BE IN ACCORDANCE
WITH ANSI/AWS A2.4
WEIJI.ZHU 2014.03.25
DRAWING TYPE
WIRING (FS-YD) C ECTRI
S
L
E H MA
EC TICALWIR
, ING (FS -YD )

SIZE ESTIMATED WEIGHT DWG NO. REVISION


EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET Schematic Diagram
INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPYRIGHT @ 2017
Ingersoll Rand
NOMENCLATURE
A1 0.0 kilogram 24276602
(KG UNLESS OTHERWISE SPECIFIED)

L 2427660 2

PART NO.
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. SCALE MODEL SHEET
ALL RIGHTS RESERVED 2.05 R30-37 1 OF 3
For Internal Use:Model=24276602|PART|L.0|Wenlong Shen|12-Dec-16 02:17:10 AM|Review<>Drawing=24276602|DRAW|L.3|Bryan Warren|15-Mar-17 12:44:29 PM|Design

8 7 6 5 4 3 2 1
15-Mar-2017 12:53:08 (model L.0/L.3)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED L.3

41
8 7 6 5 4 3 2 1

0V ZERO VOLTAGE WIRE DESIGNATION LEGEND


1M5 DRYER COMPRESSOR MOTOR NUMBERS FUNCTION WIRE COLOR-EU STD WIRE COLOR-UL STD WIRE SIZE
1M6 DRYER FAN MOTOR LABEL xLx POWER BLACK BLACK A/R
1P1 DRYER SAFETY PRESSURE SWITCH BLK BLACK
1P2 DRYER FAN PRESSURE SWITCH BLU BLUE 1xxx AC CONTROL RED RED 2
18 AWG (1mm )
1Qx DRYER CIRCUIT BREAKERS BRO BROWN 2
1xxx GROUNDED AC GREEN / YELLOW WHITE 18 AWG (1mm )
1SV LOAD VALVE GRE GREEN
1SVT 1SV HEAT TRACE PIN PINK 2xxx DC CONTROL BLUE BLUE 2
18 AWG (1mm )
2ATT AIREND DISCHARGE TEMPERATURE RED RED 2
3xxx AUXILIARY RED / BLUE / BLACK ORANGE 18 AWG (1mm )
3APT WET SUMP PRESSURE VIO VIOLET
D 3ATS AMBIENT TEMP THERMOSTAT WHI WHITE 4xxx AC POWER ORANGE RED 2 D
18 AWG (1mm )
4APT PACKAGE DISCHARGE PRESSURE YEL YELLOW
4ATT PACKAGE DISCHARGE TEMP. GND GROUNDED GREEN / YELLOW GREEN / YELLOW A/R
5SV MODULATION VALVE
9SV CONDENSATE VALVE
10SV CONDENSATE VALVE
11SV CONDENSATE VALVE
7APT PACKAGE AFTERCOOLER PRESSURE
AT1 AUTO TRANSFORMER 1. APPROVED FUSED DISCONNECT OR CIRCUIT BREAKER PER LOCAL
BLH BASE LEVEL HEATER ELECTRICAL CODES MUST BE PROVIDED BY CUSTOMER. ODM OPTION DETAIL E
BP BACKPANEL NOTES 13, 15
CAB CABINET 2. REMOVE JUMPER(S) WHEN CORRESPONDING OPTION HAS BEEN PURCHASED.
CAP CAPACITOR MCB4 KM1-3 TH
3. ONLY USED ON UNITS WITH INTEGRATED DRYERS. 404
CONT Xe CONTROLLER 401 402 403
CTO COMMON TRIP OUTPUT 4. 1L1
INDICATED OPTIONAL COMPONENTS
CTx CURRENT TRANSFORMER 5. INDICATES OPTIONAL FIELD WIRED COMPONENTS 120V
DFW DRYER FREEZE SWITCH 50/60Hz DMH SSH SSH
DHP DRYER HIGH PRESSURE SWITCH 6. A VARIABLE SPEED DRIVE IS REQUIRED FOR 37-75KW UNITS WITH LOW
DMH DRIVE MOTOR HEATER AMBIENT OPTION. SEE DETAIL A. 400
DPS DRYER PRESSURE SWITCH 1L2/N
7. A THREE PHASE TRANSFORMER IS REQUIRED FOR 575V/60HZ UNITS WITH A 410
EB EARTHING BAR VARIABLE SPEED DRIVE CONTROLLING THE BLOWER MOTOR OR TAS DRYER
ES EMERGENCY STOP BUTTON OPTION. SEE DETAIL B. MCB4 KM1-3 TH
ETC ELECTRONIC TEMPERATURE CONTROLLER 8. THERMOSTAT AND TEMPERATURE SWITCH CONTACTS ARE NORMALLY 401 402 403 404
FM FAN MOTOR 1L1
CLOSED AND WILL OPEN WHEN THE TEMPERATURE MEETS OR EXCEEDS THE
FMH FAN MOTOR HEATER INDICATED SETPOINT. SEE DETAIL C.
FMP FAN MOTOR PROTECTOR SSH
C 9. A THREE PHASE TRANSFORMER IS REQUIRED FOR DRYER OPTION: C
FR1 MAIN MOTOR OVERLOAD POWER SOURCE 200V60HZ, TRANSFORMER IS 200/230 V

404.1
230V
FU- FUSES POWER SOURCE 380V60HZ , TRANSFORMER IS 380/460 V 50/60Hz DMH
IVH INLET VALVE HEATER POWER SOURCE 570V60HZ , TRANSFORMER IS 570/460 V
K1 DRYER PRESSURE SWITCH RELAY SEE DETAIL D. SSH
K2 DRYER TEMPERATURE RELAY
K3 DRYER/BLOWER DRIVE CONTROL RELAY 10. MOTOR WIRING FOR 12 LEAD MOTORS, LOW VOLTAGE. 400
11. MOTOR WIRING FOR 12 LEAD MOTORS, HIGH VOLTAGE. 1L2/N
K4 DRYER ETC RELAY 410
K5 LOW AMBIENT CONTROL RELAY 12. MOTOR WIRING FOR 6 LEAD MOTORS.
KM1 MAIN CONTACTOR 13. HEATER CIRCUIT, CUSTOMER SUPPLIED POWER 120V OR 240V
KM2 DELTA CONTACTOR 14. INLET VALVE HEATER IVH1 AND IVH2 (TWO IN TOTAL FOR 110V) TO BE CONNECTED:
KM3 START CONTACTOR -IN SERIES IN CASE OF HEATER CIRCUIT POWER SUPPLY OF 240V
KM4 BLOWER MOTOR CONTACTOR -IN PARALLEL IN CASE OF HEATER CIRCUIT POWER SUPPLY OF 120V
KM5 DRYER COMPRESSOR MOTOR CONTACTOR 15. OUT DOOR MODIFICATION OPTION. SEE DETAIL "E"
KM6 DRYER FAN MOTOR CONTACTOR 16. 4ATT ONLY USED FOR FROST / FREESE PROTECTION OPTION.
MCB CIRCUIT BREAKERS
MM MAIN MOTOR
MSHT MOISTURE SEPARATOR HEAT TRACE
ODM OUT DOOR MODIFICATION MCB4 402
OSH OIL SUMP HEATER 1L1 DETAIL C
PE PROTECTED EARTH 1L2/N 3ATS NOTES 8, 14
PORO POWER OUTAGE RESTART OPTION 575V WIRING 30A K2-1 K2-2 (4 C / 40 F)
406
RCx ARC SUPPRESSOR FOR 37-75KW: LOW AMBIENT OPTION,
RLE REMOTE LOAD ENABLE
HEATER
KM1-3 KM1-4 LOW AMBIENT
RLU REMOTE LOAD/UNLOAD AT1
L3 5L3
RSP REMOTE STOP H3 X3 CIRCUIT,
CUSTOMER OPTION
L2 5L2 B
B SPT SERVICE PORT CONNECT TOOL H2 X2 SUPPLIED TH
L1 5L1 120/1/60 (29 C / 85 F)
RST REMOTE START H2 X1
OR
SSH STARTER SPACE HEATER FU4, 5, 6 240/1/50
405
403 403 403 403
NOTE 13 404
T1 CONTROL POWER TRANSFORMER
TH THERMOSTAT

A1
TRM POWER TERMINAL KM4

K2
SSH SSH DMH FMH 1SVT MSHT OSH IVH1 IVH2
ZNR ZENER DIODE
DETAIL B

A2
2L1 2L2 2L3

NOTE 7 410 410 410 410

24276602 REV. L
SHEET 2 OF 3

A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL ,SCH
ELECEMAT
TR
ICA
C ILW IR I NG(FS -YD)

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-YD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 2427 6602
PART NO.
24276602 L
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 2.05 SHEET 2 OF 3

8 7 6 5 4 3 2 1
15-Mar-2017 12:53:08 (model L.0/L.3)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED L.3

42
8 7 6 5 4 3 2 1

L1
D D
L2 13

L3 150

1Q1 1Q2 A2 A2 A2 A2 A2 A2
24 22

K4-2 KM5 KM6 K3 K4 K5 K6


A1 A1 A1 A1 A1 A1
21

114
111
FU1
I> I> I> I> I> I> 24 22 24 22
14 12 14 12 14 12
K5-1 K3-2
21 K3-1 K4-1 K6-1
21
11 11

112
11
KM5 KM6
24 22

113

2021

2021
K6-2

2029

2028

1031
1084

150

13
13

17
15
13

13
14
21

PE-1 PE-2 PE-3 13 14 13 15 13 17 1031 150 13


1P2 1P1 1T1
U3 V3 W3 U4 V4 W4 5 3

P
1084 2021 2021 1 ETC
100 3.1 3.3

M M 150 2029 2028


L1 1M1 3~ 1M2 3~ 1AT
C L2 C
L3
1AT Temp sensor.
Warning. Warning. ETC 1# 3# is N/C.
PE
DRYER DRYER. FAN POWER Dryer Fan Dryer High Dryer Temp Signal to Signal to Open for Alarm
MOTOR MOTOR AC 110V 50/60H Pres. Switch Pres. Switch switch. Xe controller. Xe controller. Dryer freeze

200V OR 380V OR 575V 60HZ


POWER WIRING
FOR 30-37KW: DRYER OPTION,

L3 6L3 AT2
H3 X3 7L3
L2 6L2 H2 X2 7L2
L1 6L1 H2 X1 7L1
FU7, 8, 9

DETAIL D
NOTE 9

B B

24276602 REV. L
SHEET 3 OF 3

A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL SC WIRING
AL H EM
A TI
C,
(F E
SYLECTR
- D) IC

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-YD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 24 276602
PART NO.
24276602 L
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 2.05 SHEET 3 OF 3

8 7 6 5 4 3 2 1
15-Mar-2017 12:53:08 (model L.0/L.3)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED L.3

43
RELEASED 24/May/2017 11:24:16 GMT

8 7 6 5 4 3 2 1
REVISIONS
ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

A 79093 ORIGINAL RELEASE 2010SEP27 J. HUNT B.WARREN


1C,5 B 79565 MOVED RC1 AND RC2, ADDED RC3 2011MAR10 C. LEAMON B. WARREN
1D,6 ADDED RC4
1D,5 CHANGED CDV TO CDV1, ADDED CDV2 AND CDV3
1D,4 ADDED TERMINAL NUMBERS TO FR1
1D,3 CHANGED NOTE TO SAY "PARALLEL" INSTEAD
CONNECT CUSTOMER POWER TO KM1 CONTACTOR. OF "SERIES"
1C,8 CHANGED MCB6 TO FU7,8,9 AND CHANGED SYMBOL
ES-2 1A,8 UPDATED CT RATIO TABLE
L1 L2 L3 ALTERNATE (NOTE 6) 208 2B,4 MOVED 3ATS AND ADDED K4 AND RC5
PE FU10,11 DI4 7
L3 3L3
ES-1 CONTROLLER 209 2C,5 ADDED KM1-5 AND K4-1 CONTACTS
T1 MCB3 101 102 K2-1 105 Gnd 8 3C,7 CHANGED "MCB6" TO "FU7,8,9"
D H1:575V X1:115V
100 101
DI5 9 (NOTE 6) 3B,4 CHANGE WIRING FOR TERMINAL 15 TO JUMP TO D
FM L1 3L1 1 115V
TERMINAL 12
H2:460V 6A
KM1-2 103 RC4 213 214 215
MM Gnd 10 2B,3 ADDED INLET VALVE HEATER (IVH)
MCB1
H3:415V
4SV
CDV1 212 FR1 PTC1 PTC2 PTC3
OV H4:380V X1 DI6 11 3,C7 C 79852 "TO FU7,8,9" WAS "TO MCB6". 2011JUN10 OWANESIAN B.WARREN
L3 3L3 H5:230V 95 96
1.2 1.1 1,D8 CONT WAS SGN
T1 H6:220V 105
Gnd 12
L1 3L1 150 216 REMOVED RATING FOR MCB1 AND ADDED ALT.
CONT EB H7:0V X3:0V DI7 13 216 1,C8 ADDED CONNECTION DIAGRAM FOR 12 LEAD MOTOR
150 217 FMP FD 01
1SV CDV2 Gnd 14 217 REMOVED RATING FOR FU7,8,9
MCB2 X1 FD 02 2 ADDED CONT AND TRM TO LEGEND
4SV 105 1.2 1.1 DI8 15 218 13
DHP ALTERNATE NOTE 8 37-75KW WAS 55-57KW
L3 N/O 105 P (NOTE 3) SEE DETAIL B 575V WIRING DETAIL 37-75KW WAS 55-75KW
5SV 102 219 14
L2 K2 C 150 Gnd 16 3,C5 REMOVED RATING FOR 1T1
9SV
17 220
CDV3 MULTIPLE CDE ALARM

2.2 2.3
L1 N/C X1 DI9 1,C7 D 81015 RELOCATED DRYER POWER SUPPLY. 2012AUG22 OWANESIAN B.WARREN

X2
CDV 0.5A CDE CONTACTS SHOULD
1.2 1.1 Gnd 18 221 BE WIRED IN PARALLEL 2,D4 E 81107 DETAIL "C": REMOVED 575V WIRING 2012SEP24 W.SORAH G.DRAUGHN
CAB L3 222 2,A6 FOR 37-75KW; LOW AMBINET OPTION

P3
DI10 19 RSP
BP L2 223 DETAIL "C": ADDED 230V LOW AMBIENT
Gnd 20 ADDED 575V LOW AMBIENT
DOOR L1 224
DI11 21 ADDED 575V WATER COOLED
PSU 225 RST ADDED 575V DRYER
L1 L2 L3 KM1-1 Gnd 22
NOTE 8 & 9 118 110 226 NOTE 9: ADDED 230V
A2 KM1 A1 2 TX1 DI12 23 ADDED NOTE 11 AND NOTE 12
227 RLL
KM3-1 Gnd 24 F 81440 UPDATED DRAWING TO THE LATEST FORMAT. 2013JAN18 H.AVINASH J.DAVIS
FU7,8,9 119 KM3-2 228 2-D5 UPDATED "WIRE DESIGNATION LEGEND"
A2 KM2 A1 DI13 25 RLE
229 TABLE TO THE LATEST INFORMATION AND
Gnd 26 ADDED "WIRE SIZE" COLUMN.
120 KM2-1

P1
L1 L2 L3 111 230
A2 KM3 A1 3 TX2 DI14 27 D5 G 81610 REMOVED FR1 (60 HZ ONLY) 2013FEB18 C. LEAMON B.WARREN
6L1 6L2 6L3 FMP 112 231 RLU B8 REMOVED DETAIL A
Gnd 28
DRYER A2 KM4 A1 4 TX3 232 C8 REMOVED (50HZ ONLY) AT FR1
KM1 113 DI15 29 2 REMOVED NOTE 7 AND RENUMBERED
POWER 150 233 AW1
SUPPLY 1SV 5 TX4 Gnd 30 REMOVED CTx FROM LEGEND
C (NOTE 3)
234 REVISED LOW AMBIENT OPTION DETAIL D C
I> I> I> 114 DI16 31 AW2
FR1 150 5SV 6 TX5 235 1,C6 H 82143 ADD FU1, 2, 3 WITH 1L1, 2L1, 3L1 2014FEB26 K.CODY B.WARREN
L1 L2 L3 Gnd 32 1,B6 CHANGE ORDER OF KM4 AND FU1, 2, 3
2L1 2L2 2L3 11 1L1, 1L2, 1L3 WAS 4L1, 4L2, 4L3.
KM2 311 115 236 RED
150 9SV 7
V+ 1 1AVPT 1,A1 MODEL: R37-75 WAS R55-75.
DRYER TX6 237 BLK
KM3 Gnd 2 J 82711 UPDATED THE DRAWING TO LATEST FORMAT, 2014MAY14 G.SATHISHA S.MARCUS
KM4 RUN K3-1 238 WHI 1-B6 UPDATED MCB5 FROM 1A TO 3A.
CONTACT Sig1 3 P
(NOTE 3) 10SV 239 RED 1,A6 K 83025 NOTE 7 WAS NOTE 8 IN DETAIL B 2014AUG22 K.CODY B.WARREN
U1 V1 W1 (12 LEAD W2 U2 V2 (12 LEAD V+ 4 3APT
312 240 BLK 2,D5 ADD FU1,2,3 AND 1L1, 1L2, 1L3 TO DETAIL C
U3 V3 W3 LOW V) W4 U4 V4 LOW V) Gnd 5
U V W 12 2.D4 ADD NOTE 8 TO DETAIL C
11SV 241 WHI 2,A7 NOTES SECTION: NOTE 9 WAS NOTE 10 AND 11
(12 LEAD W4 U4 V4
(12 LEAD Sig2 6 P
HIGH V) 242 RED ( COMBINED INTO ONE). NOTE 10 WAS NOTE 9
U1 V1 W1 HIGH V OR V+ 7 4APT
243 BLK B6 L 83336 MOVED FUSES FU1, 2 & 3 TO DETAIL B 2014DEC12 N.VIJAY B.WARREN
TRM 6 LEAD) W2 U2 V2 (6 LEAD) MCB5 116 Gnd 8 C6 REORDERED FMP AND KM4 WIRING.
U2 FM A2 K3 A1 8 TX7 244 WHI
V2
Sig3 9 P 2,D3 M 83412 REPLACE SYMBOL DETAIL C KM4 WITH FMP SYMBOL 2015JAN27 K.CODY H.XIANG
MM
3A 245 RED
W2 PORO 117 V+ 10 5CPT 1-C7 N 83433 ADD NOTE 8 TO NOTE 9, REMOVE NOTE 8 ON FMP 2015MAR03 K.CODY H.XIANG
150 9 TX8 246 BLK 1-C6 ADD DASHED BOX AROUND FMP, KM4
Gnd 11

P5
U3 247 WHI 1-B8 ADD ALTERNATE MOTOR WIRE NUMBERS
10 GND Sig4 12 P 2-D3 REMOVE KM4 SYMBOL- 3L1, 3L2, 3L3 WAS 2L1,2L2,2L3
V3 248 RED
FU1, 2, 3 V+ 13 6CPT 3-C7 REMOVE VERTICAL DASH LINE
W3 249 BLK
200 Gnd 14 1-C8 P 83543 REVISE MAIN MOTOR LABELS:U3 V3 W3 WAS U5 V5 2015MAR26 K.CODY H.XIANG
(12 LEAD, HIGH V ONLY) 1L1 1L2 1L3 N + 1 + 250 WHI 1-B8 W5 (2 PLACES) AND W4 U4 V4 WAS W6 U6 V6

24V

P10
104 201 Sig5 15 P (2 PLACES)
L - 2 - 251 RED
KM4 V+ 16 10APT D5 R 83357 REMOVE GROUND 1.3 AND LABEL X1 WAS KL1 2015MAR30 K.CODY A.TRAVERS
252 BLK
PSU Gnd 17 D4 ON CDV. X2 WAS KL2 ON CDE.
2L1 2L2 2L3 253 WHI
Sig6 18 P 1-D5 T 83778 REVISE CDV LINES TO ILLUSTRATE 2015JUL07 K.CODY A.TRAVERS
CONNECTION TO POSITIVE AND NEGATIVE

P7
L1 L2 L3 257 RED 1-C5 U 1215224 REMOVED RC1, RC2 & RC3 2017APR03 M.PRASHANT H.XIANG
GND V+ 22 7APT B
B PE 258 BLK (NOTE 3)
Gnd 23
K3-1 259 WHI
Sig7 24 P
283

P8
12 260 WHI
T6 T5 (12 LEAD 284 Sig1 1
(12 LEAD T1 T2 T3 T4 18 261 EB BLK 2CTT
LOW V) T7 T8 T9 T12 T10 T11 LOW V) Gnd 2 T
285 262 WHI
27 WHI Sig2 3
(12 LEAD (12 LEAD 216 263 EB BLK 2ATT
T12 T10 T11 FD 216 BLU WHI 294 10 AO1 T
HIGH V OR T1 T2 T3 HIGH V) 01 P3-13 Gnd 4
264 WHI

P4
6 LEAD) 217 295 ZNR 9 AO+ Sig3 5
T6 T4 T5 (6 LEAD) 217 BLU BLK 265 EB 4ATT
02 P3-14 BLK T
TRM 8 COM
Gnd 6
T4 294 WHI CAP BLK 266 WHI
60 Sig4 7
3CTT

P6
T5 295 BLK 267 EB BLK T (NOTE 2)
MM 55 Gnd 8
T6 268 WHI
305 1 N/O
Sig5 11
269 EB BLK 5DTT (NOTE 3)
T7 PE 303
CTO 306 Gnd 12 T
2 C 270 WHI
T8 307 Sig6 13
U V W 3 N/C 271 EB BLK 6DTT (NOTE 3)

P2
T9 KM1-4
308 Gnd 14 T
U W V 4 N/O
(12 LEAD, HIGH V ONLY) 274 WHI
CWO 309 5 C Sig8 17
304 275 EB BLK 1ATT (NOTE 2)
ALTERNATE MOTOR WIRE NUMBERS 310 6 N/C Gnd 18 T
FM DETAIL B MOTOR
RUNNING 23603582 REV U
NOTE 7 CONTACT
SHEET 1 OF 3

A A
WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED DO NOT SCALE DRAWING
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
NOTES: AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO THIRD ANGLE PROJECTION
1. DECAL MUST CONFORM TO THE LATEST REVISION OF IR SPECIFICATION 92-8.95. PROPRIETARY NOTICE ASME Y14.5M - 1994 DRAWN DATE

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, J. HUNT 2010SEP27
R

INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE NAME
GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS
B.WARREN
APPROVED
2010SEP27
DATE
SCHEMATIC, ELECTRICAL
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS
- WELD SYMBOLS TO BE IN ACCORDANCE
WITH ANSI/AWS A2.4
B.WARREN 2010SEP27
DRAWING TYPE
WIRING (FS-SD) CAT
S
M HC,IEELECT RIC
A LWIRING (F S-S
D )

SIZE ESTIMATED WEIGHT DWG NO. REVISION


EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET Schematic Diagram
INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPYRIGHT @ 2017
Ingersoll Rand
NOMENCLATURE
A1 0.0 kilogram 23603582
(KG UNLESS OTHERWISE SPECIFIED)

U 23 603582

PART NO.
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. SCALE MODEL SHEET
Ingersoll-Rand Industrial Technologies ALL RIGHTS RESERVED 1.00 R37-75 1 OF 3
For Internal Use:Model=23603582|ASSEM|U.0|Prashanta, Malagi|03-Apr-17 08:58:28 AM|Open<>Drawing=23603582|DRAW|U.1|Prashanta, Malagi|03-Apr-17 09:57:18 AM|Open

8 7 6 5 4 3 2 1
03-Apr-2017 09:57:39 (model U.0/U.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED U.1

44
RELEASED 24/May/2017 11:24:16 GMT

8 7 6 5 4 3 2 1

LEGEND WIRE DESIGNATION LEGEND 230V LOW AMBIENT


LABEL DESCRIPTION 575V LOW AMBIENT
D OV ZERO VOLTAGE NUMBERS FUNCTION WIRE COLOR-EU STD WIRE COLOR-UL STD WIRE SIZE D
575V WATER COOLED
1ATT PACKAGE INLET TEMPERATURE 1 - 99 POWER BLACK BLACK A/R
1AVPT INLET VACUUM PRESSURE
575V DRYER
1M1 DRYER COMPRESSOR MOTOR 100 - 199 AC CONTROL RED RED 2
18 AWG (1mm )
1M2 DRYER FAN MOTOR L3 5L3 AT1
100 - 199 GROUNDED AC GREEN / YELLOW WHITE 2 H3 X3
1P1 DRYER SAFETY PRESSURE SWITCH 18 AWG (1mm )
1P2 DRYER SAFETY FAN PRESSURE SWITCH 2 L2 5L2 H2 X2
200 - 299 DC CONTROL BLUE BLUE 18 AWG (1mm )
1Qx DRYER CIRCUIT BREAKERS L1 5L1 H1 X1
1SV LOAD VALVE 300 - 399 AUXILIARY RED / BLUE / BLACK ORANGE 2
1SVT 1SV HEAT TRACE 18 AWG (1mm )
FU4, 5, 6
1T1 DRYER CONTROL POWER TRANSFORMER 400-499 AC POWER ORANGE RED 2
18 AWG (1mm )
2ATT AIREND DISCHARGE TEMPERATURE
2CTT INJECTED COOLENT TEMPERATURE GND GROUNDED GREEN / YELLOW GREEN / YELLOW A/R
3APT WET SUMP PRESSURE
3ATS AMBIENT TEMP THERMOSTAT
3CTT COOLANT COOLER OUT TEMP. DETAIL C
4APT PACKAGE DISCHARGE PRESSURE
4ATT PACKAGE DISCHARGE TEMPERATURE NOTE 8 AND 9 3L1 3L2 3L3
4SV WATER SHUT OFF VALVE (W/C ONLY)
5CPT COOLANT FILTER IN PRESSURE
5DTT DRYER DEWPOINT
5SV MODULATION VALVE MCB4 402
6CPT COOLANT FILTER OUT PRESSURE 1L1 DETAIL D
6DTT REFRIGERANT TEMPERATURE 3ATS
7APT PACKAGE A/C PRESSURE 1L2/N K4-1 (4 C / 40 F) NOTE 10
30A
9SV MOISTURE SEPARATOR DRAIN VALVE
10APT REMOTE PRESSURE 406
10SV DRYER FILTER DRAIN VALVE
WIRE COLOR LEGEND
11SV
AT1
DRYER DRAIN VALVE
AUTO TRANSFORMER LABEL DESCRIPTION
HEATER
CIRCUIT,
KM1-3 KM1-5 LOW AMBIENT
C AW1 AUXILIARY WARNING 1 C
AW2 AUXILIARY WARNING 2 BLK BLACK
CUSTOMER
SUPPLIED TH OPTION
BLH BASE LEVEL HEATER BLU BLUE 120/1/60 (29 C / 85 F)
BP BACKPANEL
CAB CABINET BRO BROWN 403 403 403
405 403
CAP CAPACITOR 404
CDE1 CONDENSATE DRAIN ERROR (M/S)
GRE GREEN
CDE2 CONDENSATE DRAIN ERROR (DRYER FILTER) PIN PINK

A1
CDE3 CONDENSATE DRAIN ERROR (DRYER DRAIN)

RC5

K4
CDV1 CONDENSATE NO LOSS DRAIN VALVE (M/S) RED RED SSH SSH DMH FMH 1SVT MSHT OSH OSH OSH BLH IVH1 IVH2
CDV2 CONDENSATE NO LOSS DRAIN VALVE (DRYER FILTER)

A2
VIO VIOLET
CDV3 CONDENSATE NO LOSS DRAIN VALVE (DRYER DRAIN)
CTO COMMON TRIP OUTPUT WHI WHITE
CWO COMMON WARNING OUTPUT 410 410 410 410
CONT Xe CONTROLLER
YEL YELLOW
MCB4 402
DHP DRYER HIGH PRESSURE SWITCH
1L1
DMH DRIVE MOTOR HEATER
EB EARTHING BAR 3ATS
ES EMERGENCY STOP BUTTON 1L2/N K4-1 (4 C / 40 F)
30A
FD FAN DRIVE
FM FAN MOTOR 406
FMH FAN MOTOR HEATER
FMP FAN MOTOR PROTECTOR HEATER KM1-3 KM1-5
403 403 403 403
FR1 MAIN MOTOR OVERLOAD CIRCUIT,
FU- FUSES CUSTOMER
K2 PHASE MONITOR RELAY SUPPLIED
K3 BLOWER DRIVE CONTROL RELAY TH
240/1/50
KM1 MAIN CONTACTOR (29 C / 85 F) IVH1
KM2 DELTA CONTACTOR
KM3 START CONTACTOR 405 404
403A
B KM4 FAN MOTOR CONTACTOR B
KM5 DRYER COMPRESSOR CONTACTOR

A1
KM6 DRYER FAN MOTOR CONTACTOR

RC5

K4
SSH SSH DMH FMH 1SVT MSHT OSH OSH OSH BLH IVH2
MCB CIRCUIT BREAKERS

A2
MM MAIN MOTOR
MSHT MOISTURE SEPARATOR HEAT TRACE
OSH OIL SUMP HEATER
PE PROTECTED EARTH 410 410 410 410
PORO POWER OUTAGE RESTART OPTION NOTES:
PSU POWER SUPPPLY UNIT
PTCx MOTOR WINDING THERMISTOR 1. APPROVED FUSED DISCONNECT OR CIRCUIT BREAKER PER LOCAL ELECTRICAL CODES
R1 DRYER PRESSURE SWITCH RELAY
RCx ARC SUPPRESSOR MUST BE PROVIDED BY THE CUSTOMER.
RLE REMOTE LOAD ENABLE 2. SENSORS 1ATT AND 3CTT ARE ONLY USED WHEN THE SMART THERMAL VALVE IS INSTALLED.
RLL REMOTE LEAD LAG 3. ONLY USED ON UNITS WITH INTEGRATED DRYERS.
RLU REMOTE LOAD/UNLOAD
RSP REMOTE STOP
4. INDICATES OPTIONAL COMPONENTS.
RST REMOTE START 5. INDICATES OPTIONAL FIELD WIRED COMPONENTS.
SS SOLID STATE RELAYS 6. REMOVE JUMPER(S) WHEN CORRESPONDING OPTION HAS BEEN PURCHASED.
SSH STARTER SPACE HEATER 7. A VARIABLE SPEED DRIVE IS REQUIRED FOR 37-75kW UNITS WITH LOW AMBIENT OPTION.
T1 CONTROL POWER TRANSFORMER
TH THERMOSTAT SEE DETAIL B.
TRM POWER TERMINAL 8. A THREE PHASE TRANSFORMER IS REQUIRED FOR 230V AND 575V 60 Hz UNITS WITH A
ZNR ZENER DIODE VARIABLE SPEED DRIVE CONTROLLING THE BLOWER MOTOR. SEE DETAIL C.
IVH INLET VALVE HEATER 9. A THREE PHASE TRANSFORMER IS REQUIRED FOR 575V 60 Hz WATER COOLED UNITS AND
575V 60Hz UNITS WITH A DRYER. SEE DETAIL C.
10. THERMOSTAT AND TEMPERATURE SWITCH CONTACTS ARE NORMALLY CLOSED AND WILL OPEN
WHEN THE TEMPERATURE MEETS OR EXCEEDS THE INDICATED SET POINT. SEE DETAIL D. 23603582 REV U
SHEET 2 OF 3
A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL SCH
MA
T CI EE, LE CTRCAI L WIRIN G(FS S- )D

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-SD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 236035 82
PART NO.
23603582 U
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 2 OF 3

8 7 6 5 4 3 2 1
03-Apr-2017 09:57:39 (model U.0/U.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED U.1

45
RELEASED 24/May/2017 11:24:16 GMT

8 7 6 5 4 3 2 1

D D

6L1

6L2
TO FU7,8,9
6L3

PE

1Q1 1Q2
F1 F1

C C
I> I> I> I> I> I>
1T1
100VA
KM5 0V 12V24V

KM5 KM6
F2

L1R

L2R
U1 V1 W1 U2 V2 W2

2/24

1/24
A2 A2 A2

KM5 KM6 R1
A1 A1 A1

15
24 22 14 12

R1 R1
21 11

1/24

1/24

1/24
B B

12

13

14

16

18

22
X1
X1

X1

X1

X2

X1

X1

X1

X2

X1

X1

X2

X1

X1

X1

X1

X1

X1

X1

X1

X1

X1

X1
2 3 4 PE-1 5 6 7 PE-10 8 9 PE 11 12 13 14 15 16 17 18 19 20 21 22

U V W PE U V W PE

P
1P2 1P1
M M
1M1 3~ 1M2 3~

A 23603582 REV U A
SHEET 3 OF 3

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL IS RING
CHEM
(F SATIC,
S- D)
EL ECTRCA
I LW

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-SD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 23603582
PART NO.
23603582 U
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 3 OF 3

8 7 6 5 4 3 2 1
03-Apr-2017 09:57:39 (model U.0/U.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED U.1

46
8 7 6 5 4 3 2 1
REVISIONS
ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

A 83211 ORIGINAL RELEASE 2015MAR17 N.VIJAY B.WARREN


B 83695 UPDATED SCHEMATIC IN SHEET 1 AND 2 2015JUN19 Y.SURESH B. WARREN
SHEET 4: UPDATED LEGEND AND ADDED NOTE 9
ADDED SHEET 5
C 1004053 SH1: REMOVED TERMINAL 201; CHANGED 6L1, 6L2, 6L3 2015NOV13 B.WARREN B.WARREN
TO 5L1, 5L2, 5L3; CHANGED 7L1 AND 7L3 TO 8L1 AND
8L3; CHANGED 216 AND 217 TO 208 AND 209; ADDED
L3
L3 OPTIONAL PORO CIRCUIT.
L2 SH2: ADDED 7SV; ADDED K6, ADDED 113 AND 117
01 L2 SH3: REMOVED 2APT
L1 SH4: UPDATED NOTES AND MOVED TO SHEET 5
L1
SH5: MOVED DRYER OPTION TO SHEET 4
1-D6 D 1147102 UPDATED DETAIL B. 2016APR08 B.WARREN B.WARREN
D 1-D3 REMOVED FU7,8,9. D
L1 L3 L1 L2 L3
PE 208V ; L1 L3 4-D7 ADDED ODM WIRING.
5-C5 ADDED NOTES 18, 19.
L1 L2 L3
575V MCB1 MCB2
FU10,11 5 E 1072341 ADDED NOTE 20 2016DEC06 C.LEAMON B.WARREN
3A 0.5A
1L1 1L3 1L1 1L3

FM L1 L2 L3 L1 L2 L3 FU4,5,6 8L1 8L3


L1 L2 L3 5L1 5L2 5L3
MM
"D"

H6:220V
H5:230V
H4:380V
H3:415V
H2:460V
H1:575V
OV EB 230V-

H7:0V
KM1 KM2 KM3

L1
L2
L3
3L1 3L2 3L3
T1 460V
08
CONT H1 H2 H3 T1 K2
1SV I> I> I> FR1 "E"

X3:0V

X1:115V
AT1
4SV 150 100
X1 X2 X3 09
5SV

N/O
N/C
C
7SV U1 V1 W1
10
W2 U2 V2 7L1 7L2 7L3 MCB3
U5 V5 W5 W6 U6 V6 10
6A

102
105
9SV
10SV
11SV W6 U6 V6 11
11
CAB U1 V1 W1
12
BP W2 U2 V2 12
DOOR
RED
FD FU1,2,3 ; 5L1 5L2 5L3 101
PSU FMP
C U2 "B" MCB5
CDV-1 ES-1 C
V2 KM1-2 K6 KL1
TRM MM 3A 1.3 1.2 1.1
W2 06 150 105
102
U5 CDV-2
KL1 04
V5 1.3 1.2 1.1
W5 150
105
11 CDV-3
KL1
103 1.3 1.2 1.1
FU1,2,3 1
121
115V

4SV A1
104 150 105

PORO
2L1 2L2 2L3
P1

RC4
KM4 L
200

A2
BLU
+ 1 +

VDC
4L1 4L2 4L3 PSU 201 P10
(24Vdc) - BLU/WHT
2 -
T1 T2 T3 T6 T4 T5 10 L1 L2 L3 150
10
T7 T8 T9 T12 T10 T11 GND N CONT
PE

RTDMON-J

RTDMON-I
P3-5 K3-1 WHT(UL)
T12 T10 T11 11
11 BLU 283 GRN/YEL(EU)
T1 T2 T3 12 P8
12 208 BLU 284
T6 T4 T5 12 18
BLU 285
FMP 13 27
208 P7
FD 01
BLU
P3-5
B I> I> I> 14 B
BLU 209 CAP
T4 02 P3-6 WHI
WHI 294 10 AO1
T5 MM WHI 294
TRM 4L1 4L2 4L3 209 60
T6 295 ZNR 9 AO+ P4
BLK 295 BLK
T7 55
KM4 P3-6 8 COM
T8 BLK
T9 PE
U V W
11 U V W
U W V
"A"
FM FM
05

49107048 REV D
SHEET 1 OF 5

NOTES:
A A
1. DECAL MUST CONFORM TO THE LATEST REVISION OF IR SPECIFICATION 92-8.95. STANDARD TOLERANCES WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
DO NOT SCALE DRAWING
AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO THIRD ANGLE PROJECTION
ALL DIMENSIONS ARE IN ASME Y14.5M - 1994
MILLIMETERS PROPRIETARY NOTICE DRAWN DATE
[INCHES (IF SHOWN)] THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, N.VIJAY 2015MAR17
R

INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE NAME
UNSPECIFIED TOLERANCES: GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS
B.WARREN
APPROVED
2015MAR17
DATE
SCHEMATIC, ELECTRICAL
WHOLE
ONE PLACE (.X)
:
:
1
0.5
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS
- WELD SYMBOLS TO BE IN ACCORDANCE
WITH ANSI/AWS A2.4
B.WARREN 2015MAR17
DRAWING TYPE
WIRING (FS-SD) ARES CS-SD
S
(F H ME A
A) E
IC
T
R ES
, L ECRTC
I LA WIR NG
I

SIZE ESTIMATED WEIGHT DWG NO. REVISION


TWO PLACE (.XX) : 0.25 EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET Detail Drawing
ANGLES (.X) : 1 INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPYRIGHT @ 2016
Ingersoll Rand
NOMENCLATURE
49107048
(KG UNLESS OTHERWISE SPECIFIED)

A1 0.0 kilogram E 49107048

PART NO.
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. SCALE MODEL SHEET
Ingersoll-Rand Industrial Technologies ALL RIGHTS RESERVED 1.00 ARES 1 OF 5
For Internal Use:Model=49107048|PART|E.0|Chris Leamon|06-Dec-16 04:17:26 PM|Open<>Drawing=49107048|DRAW|E.1|Chris Leamon|06-Dec-16 04:23:12 PM|Open

8 7 6 5 4 3 2 1
06-Dec-2016 04:23:23 (model E.0/E.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.1

47
8 7 6 5 4 3 2 1

D D

DI3
V+
5 6

208
209
02
FD

01
"G"
13

CONT

P1 P2 P4 P3
C C
115V

GND

DI10

DI11

DI12

DI13

DI14

DI15

DI16
TX1

TX2

TX3

TX4

TX5

TX6

TX7

TX8

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8

DI9
N/O

N/O
N/C

N/C

V+

V+

V+

V+

V+

V+

V+

V+

V+

V+

V+

V+

V+

V+

V+

V+
V+

V+
V-

V-
C

C
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

305
306
307
308
309
310

207
208
209
105

110

296
297
298
299

204

210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
202
203

232
233
234
235
113

114

115
112

117
111

116
116
***A***

KM1-1 KM3-1

206
TR-1
04
KM3-2 KM2-1 2
SEC

205
118

119

120

114A

95

13
A1
KM4 A1

A1
KM1 A1

KM2 A1

KM3 A1

A1

FMP
RC1

RC2

RC3

TR
K3

K5

96

14
+

+
TRR
ES-2 FR1

K6
A2
A2

A2
A2

A2

A2

A2

105
04 13

-
150 150 150 150 150

305
306
307
308
309
310

210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225

232
233
234
235
KM1-4 TRR-1
303

304

313

314
13 14
2.2 2.3 2.2 2.3
KL2 KL2
***B***

B B

CDE1

CDE2
P
10SVA1
7SV A1

1SV A1

5SV A1

9SV A1

11SVA1

DHP
A2
A2

A2

A2

A2

A2

09

303 304 313 314


***C***

CTO CWO RSP RST RLE RLU RLL AW1 AW2

49107048 REV D
A SHEET 2 OF 5 A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL SC HMA
E IT C,ELEC RTCI AL WIRING ( F -SD
S )ARES

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-SD) ARES
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 4 1907 048
PART NO.
49107048 E
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 2 OF 5

8 7 6 5 4 3 2 1
06-Dec-2016 04:23:23 (model E.0/E.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.1

48
8 7 6 5 4 3 2 1

D D

278

COM3
7 A D-

P9
279

COMM
CONT 8 B D+ RTDMON
C GND
D INIT

P5 P6 PWR INPUT

+5Vdc
+5Vdc

+5Vdc
+5Vdc
Sig10
Sig10
Sig11
Sig11
Sig12
Sig12

Sig13
Sig13
Sig14
Sig14
Sig15
Sig15
Sig16
Sig16
Sig1

Sig9
Sig9
Sig2

Sig7
Sig3

Sig8
Sig4

Sig5

Sig6
Gnd

Gnd

Gnd
Gnd

Gnd
Gnd

Gnd

Gnd

IN0
IN0
IN1
IN1
IN2
IN2
IN3
IN3
IN4
IN4
IN5
IN5
IN6
IN6
IN7
IN7
V+

V+

V+

V+
V+

V+
V+

V+

V+

V-
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 I J 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
***A***

RTD11
RTD12
RTD21
RTD22
RTD31
RTD32
RTD41
RTD42
RTD51
RTD52
RTD61
RTD62
RTD71
RTD72
RTD81
RTD82
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259

260
261
262
263
264
265

268
269
270
271
272
273

201
200
C C
RED

RED

RED

RED

RED

RED

RED

RED
WHI

WHI

WHI

WHI

WHI

WHI

WHI

WHI
BLK

BLK

BLK

BLK

BLK

BLK

BLK

BLK

WHI

WHI

WHI

WHI

WHI

WHI
BLK

BLK

BLK

BLK

BLK

BLK

WHI

WHI

WHI

WHI

WHI

WHI

WHI

WHI
BLK

BLK

BLK

BLK

BLK

BLK

BLK

BLK
PSU VDC+
PSU VDC-
***B***

T T T T T T T T T T T T T T
P P P P P P P P 1ATT 2ATT 2CTT 4ATT 5DTT 6DTT RTD1 RTD2 RTD3 RTD4 RTD5 RTD6 RTD7 RTD8
1AVPT 2APT 3APT 4APT 5CPT 6CPT 7APT 10APT 16 09 09
17 15 09
***C***

B B

49107048 REV D
SHEET 3 OF 5

A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL SC HEMATI
ELE CTRICA
, CLIRI
WN G(FS S- D)A RES

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-SD) ARES
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 49107 048
PART NO.
49107048 E
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 3 OF 5

8 7 6 5 4 3 2 1
06-Dec-2016 04:23:23 (model E.0/E.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED E.1

49
8 7 6 5 4 3 2 1

MCB4 402
1L1
MCB4 KM1-3 TH "H" 3ATS
"C"
401 402 404 403 07
1L2/N K4-1 K4-2 (4 C / 40 F) 07
30A
1L1
14 406
D 120V
50/60Hz DMH SSH SSH
D
KM1-3 KM1-5
400 410
1L2/N 404
TH
(29 C / 85 F)
14 403 403 403
MCB4 405 403
KM1-3 TH
401 402 404 403
1L1

A1
RC5

K4
SSH SSH SSH DMH FMH 1SVT MSHT OSH OSH OSH BLH IVH 19

A2
403.1
230V
50/60Hz DMH
410 410 410 410
SSH
400 410
1L2/N

C C
"F"
X3

5L1 09
1 1T1
X3

F1 75VA F2

X4
5L2 1/24-A 1/24
2 2 24V
5A
X3

F1
X4
5L3
12V 2/24
3 3 0V
0.5A
PE

L1R-A
1 3 5 1 3 5

KM5
1Q1 1Q2 A2 A2 A2

I> I> I> I> I> I> KM5 KM6 R1


A1 A1 A1
2 4 6 2 4 6
L1R

L2R

15
1 3 5 1 3 5
24 22 14 12
KM5 KM6
2 4 6 2 4 6 R1 R1
B 21 11 B

1/24

1/24
U1 V1 W1 U2 V2 W2

12
13

14

16

18

22
1
2
X1

X1

X1

X2

X1

X1

X1

X2

X1

X1

X2

X1

X1

X1

X1

X1

X1

X1

X1

X1

X1

X1

X1
2 3 4 PE-1 5 6 7 PE-10 8 9 PE 11 12 13 14 15 16 17 18 19 20 21 22

U V W PE U V W PE K5-1

P
1P2 1T2 1P1
M M
1M1 3~ 1M2 3~

49107048 REV D
SHEET 4 OF 5

A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL S CHEC,ELEC RTCA
MATI I L WIR NG
I (FS-S D ARE
) S

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-SD) ARES
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 491070 48
PART NO.
49107048 D
E
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 4 OF 5

8 7 6 5 4 3 2 1
06-Dec-2016 04:23:23 (model E.0/E.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED D.3
E.1

50
8 7 6 5 4 3 2 1

LEGEND LEGEND
LABEL DESCRIPTION LABEL DESCRIPTION
0V ZERO VOLTAGE RTD7 MOTOR DE BEARING RTD NOTES:
1ATT PACKAGE INLET TEMPERATURE RTD8 MOTOR NDE BEARING RTD
1AVPT INLET VACUUM PRESSURE RTDMON MOTOR RTD MONITOR 1. APPROVED FUSED DISCONNECT OR CIRCUIT BREAKER PER LOCAL
1P1 DRYER SAFETY PRESSURE SWITCH SSH STARTER SPACE HEATER ELECTRICAL CODES MUST BE PROVIDED BY CUSTOMER.
1P2 DRYER FAN PRESSURE SWITCH T1 CONTROL POWER TRANSFORMER 2. INDICATES OPTIONAL COMPONENTS.
TH THERMOSTAT 3. INDICATES OPTIONAL FIELD WIRED COMPONENTS. D
D 1Q1 DRYER COMPRESSOR MOTOR OVERLOAD
1Q2 DRYER FAN MOTOR OVERLOAD TR TIMING RELAY 4. REMOVE JUMPER(S) WHEN CORRESPONDING OPTION HAS BEEN PURCHASED.
1SV LOAD VALVE TRM POWER TERMINAL 5. A VARIABLE SPEED DRIVE IS REQUIRED FOR AIR COOLED (A/C) UNITS WITH FREEZE
1SVT 1SV HEAT TRACE TRR COMPRESSOR RUNNING LOADED RELAY PROTECTION OPTION. SEE DETAIL "A".
1T1 DRYER CONTROL POWER TRANSFORMER ZNR ZENER DIODE 6. A THREE-PHASE AUTO-TRANSFORMER IS REQUIRED FOR WATER COOLED UNITS (W/C) AT 575V/
1T2 DRYER FAN 1M2 THERMAL SWITCH 60HZ, A/C UNITS WITH LOW AMBIENT AT 575V/60HZ, UNITS WITH A DRYER AT 208V/60HZ OR
2APT INTERSTAGE PRESSURE 575V/60HZ . SEE DETAIL "B".
2ATT AIREND DISCHARGE TEMPERATURE 7. THERMOSTAT AND TEMPERATURE SWITCH CONTACTS ARE NORMALLY CLOSED AND WILL
2CTT INJECTED COOLANT TEMPERATURE OPEN WHEN THE TEMPERATURE MEETS OR EXCEEDS THE INDICATED SETPOINT. SEE DETAIL "C".
3APT SUMP PRESSURE 8. FUSES 10 AND 11 ARE AN ACCEPTABLE ALTERNATE TO MCB1 AND REQUIRED WHEN LINE POWER
3ATS AMBIENT TEMP THERMOSTAT IS 575V/60HZ. SEE DETAIL "D".
4APT PACKAGE DISCHARGE PRESSURE 9. ONLY USED ON UNITS WITH INTEGRATED DRYERS. SEE DETAILS "E" AND "F".
4ATT AFTERCOOLER DISCHARGE TEMP. 10. MOTOR WIRING FOR 12 LEAD MOTORS, LOW VOLTAGE.
4SV WATER SHUT OFF VALVE (W/C ONLY) 11. MOTOR WIRING FOR 12 LEAD MOTORS, HIGH VOLTAGE.
5CPT COOLANT FILTER INLET PRESSURE 12. MOTOR WIRING FOR 6 LEAD MOTORS.
5DTT DRYER EVAPORATOR TEMPERATURE 13. FAN MOTOR OVERLOAD FAULT INPUT ALTERNATE WIRING FOR LOW AMBIENT OPTION. SEE
5SV MODULATION VALVE DETAIL "G".
6CPT COOLANT FILTER OUTLET PRESSURE 14. HEATER CIRCUIT, CUSTOMER SUPPLIED 120/1/60 OR 240/1/50.
6DTT DRYER CONDENSER TEMPERATURE 15. FOR TWO-STAGE UNITS ONLY.
7APT AFTERCOOLER DISCHARGE PRESSURE
7SV LOAD VALVE ISOLATION 16. INPUT 1ATT IS ONLY AVAILABLE FOR UNITS WITH ENABLE AMBIENT MONITORING TURNED ON.
9SV CONDENSATE SOLENOID VALVE 17. INPUT 1AVPT IS ONLY AVAILABLE FOR UNITS WITH ENABLE MODULATION OR ENABLE INLET
10APT REMOTE PRESSURE FILTER MONITORING TURNED ON.
10SV CONDENSATE SOLENOID VALVE 18. OUT DOOR MODIFICATION OPTION. SEE DETAIL "H".
11SV CONDENSATE SOLENOID VALVE 19. INLET VALVE HEATER (TWO IN TOTAL FOR 110V) TO BE CONNECTED
AT1 AUTO TRANSFORMER - IN SERIES IN CASE OF HEATER CIRCUIT POWER SUPPLY OF 240V
AW1 AUXILIARY WARNING 1 - IN PARALEL IN CASE OF HEATER CIRCUIT POWER SUPPLY OF 120V
AW2 AUXILIARY WARNING 2 20. REFERENCE ENGINEERING STANDARD 47559901001 FOR STARTERBOX WIRING REQUIREMENTS.
C BLH BASE LEVEL HEATER C
BP BACKPANEL
CAB CABINET
CAP CAPACITOR
CDEx CONDENSATE DRAIN ERROR
CDVx CONDENDATE DRAIN VALVE
CONT Xe CONTROLLER COMPONENT LOCATION:
CTO COMMON TRIP OUTPUT
***A***: ELECTRICAL CABINET
CWO COMMON WARNING OUTPUT
***B***: COMPRESSOR
DHP DRYER HIGH PRESSURE
***C***: CUSTOMER/FIELD
DMH DRIVE MOTOR HEATER
DTW DRYER TEMPERATURE WARNING
EB EARTHING BAR WIRE DESIGNATION LEGEND
ES EMERGENCY STOP BUTTON NUMBERS FUNCTION WIRE COLOR-EU STD WIRE COLOR-UL STD WIRE SIZE
FD FAN DRIVE
FM FAN MOTOR 1 - 99 POWER BLACK BLACK PER CODES
FMH FAN MOTOR HEATER 100 - 199 AC CONTROL RED RED 2
FMP FAN MOTOR PROTECTOR
18 AWG (1mm )
FR1 MAIN MOTOR OVERLOAD 100 - 199 GROUNDED AC GREEN / YELLOW WHITE 2
18 AWG (1mm )
Fx DRYER FUSES
200 - 299 DC CONTROL BLUE BLUE 2
FUx FUSES 18 AWG (1mm )
IVH INLET VALVE HEATER 300 - 399 AUXILIARY RED / BLUE / BLACK ORANGE 2
K2 PHASE MONITOR RELAY 18 AWG (1mm )
K3 BLOWER DRIVE CONTROL RELAY 400-499 AC POWER ORANGE RED 2
18 AWG (1mm )
K4 LOW AMBIENT CONTROL RELAY
K5 DRYER RUN INDICATION RELAY GND GROUNDED GREEN / YELLOW GREEN / YELLOW PER CODES
K6 PORO RELAY
KM1 MAIN CONTACTOR
B KM2 DELTA CONTACTOR
B
KM3 START CONTACTOR
KM4 COOLING FAN MOTOR CONTACTOR
KM5 DRYER COMPRESSOR CONTACTOR WIRE COLOR LEGEND
KM6 DRYER FAN CONTACTOR LABEL DESCRIPTION
MCBx CIRCUIT BREAKERS
MM MAIN MOTOR BLK BLACK
MSHT MOISTURE SEPARATOR HEAT TRACE BLU BLUE
OSH OIL SUMP HEATER
BRO BROWN
PE PROTECTED EARTH
PORO POWER OUTAGE RESTART OPTION GRE GREEN
PSU POWER SUPPLY UNIT
PIN PINK
R1 DRYER CONTROL RELAY
RCx ARC SUPPRESSOR RED RED
RLE REMOTE LOAD ENABLE VIO VIOLET
RLL REMOTE LEAD LAG
RLU REMOTE LOAD/UNLOAD WHI WHITE
RSP REMOTE STOP YEL YELLOW
RST REMOTE START
RTD1-6 MOTOR WINDING RTD 49107048 REV D
SHEET 5 OF 5

A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL SCH
AL
A WIRI
RESEM
A TI
N GC,
(FS-
EL SD)
C
E TRIC

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-SD) ARES
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 4910704 8
PART NO.
49107048 D
E
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 1.00 SHEET 5 OF 5

8 7 6 5 4 3 2 1
06-Dec-2016 04:23:23 (model E.0/E.1)
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED D.3
E.1

51
8 7 6 5 4 3 2 1
REVISIONS
ZONE REV ECN DESCRIPTION DATE DRAWN APP'D

A 83172 ORIGINAL RELEASE 2014OCT03 N.VIJAY B.WARREN


B 83235 REVISED COMPLETE SCHEMATIC, LEGEND & NOTES. 2014OCT27 N.VIJAY B.WARREN
C8 C 83262 U3, V3, W3 WAS U5, V5, W5 2015MAR10 N.VIJAY B.WARREN
U3, V3, W3 WAS U5, V5, W5
C7 W4, U4, V4 WAS W6, U6, V6
B6 REVISED DETAIL A
C4 REVISED CDV-1, CDV-2, & CDV-3
B4 D 83601 ADDED 2SV 2015APR28 C. LEAMON B.WARREN
L3 2-B6 9SV WAS 6SV
L3 2 - L3
L2 KM1-3 TH
2-B7 ADDED 1SV (B1/B2)
L2 2 - L2 MCB4 4 ADDED 2SV TO LEGEND
L1 1HE1 2HE1 404 404 1-C7 E 1143002 MODIFIED MAIN MOTOR LEAD CONNECTIONS 2016OCT24 B.WARREN B.WARREN
L1 2 - L1 1L1
401 402 403
D 1-B4 ADDED PORO CIRCUIT D
1-C3 ADDED 1ATS
1-B4 ADDED HARNESS CONNECTORS
PE 120V
1-A6 CHANGED DRIVE SIGNAL WIRING
50/60Hz 1HE 2HE SSH SSH
1-C4 REMOVED CDV2 AND CDV3
2-C7 ADDED KM5 OPTION
575V 400 2-B7 ADDED 7SV, CORRECTED 1SV CONTROL WIRING
FM1 1L2/N 2-B6 ADDED 3SVA AND 3SVB
1HE2
FM2 2HE2 410 2-C7 ADDED 112 AND 113
2-C6 REMOVED 117
MM L1 L2 L3 L1 L2 L3 2-B3 REMOVED PORO AND ADDED K6
L1 L2 L3 L1 L2 L3
OV
14
"F" 2-B4
3-B7
REMOVED CDE2, DHP, DTW
REMOVED 7APT
T1 MCB4 KM1-3 TH 3-B5 REMOVED 5DTT AND 6DTT
KM1 KM2 KM3 15
FU7,8,9 401 402 404 1HE1 403 3-B4 CHANGED NAME OF MOTOR RTDS AND WIRING
CONT 1L1 4-D4 ADDED OUTDOOR MOD HEATER WIRING
1SV 4-C3 REMOVED DMH, ADDED 1HE AND 2HE
EB 4 UPDATED LEGEND AND NOTES
I> I> I> 3L1 3L2 3L3 1HE SSH
2SV FR1 1-B4 F 1189462 XS10 WAS XS4 2017MAR10 B.WARREN B.WARREN
3SV 1-C4 XS6 WAS XS8

403.1
1HE2
H1 H2 H3 2-B6 XS9 WAS XS5
4SV U1 W1 V1 W2 V2 U2 230V
50/60Hz
2HE1
2-B6 XS10 WAS XS4
5SV AT1 2-B3 XS5 WAS XS9
3-C6 XS3 WAS XS10
7SV SSH
2HE 1-D5 G 1223466 FU7,8,9 WAS FU4,5,6 2017APR11 T.DOUGHER B.WARREN
9SV 16
X1 X2 X3
1-C6 FU1,2,3 REMOVED
400
PSU 1L2/N 2 ADDITIONAL SHEET ADDED
2HE2
410 2 RIGHT HALF OF SHEET 1 MOVED TO SHEET 2
CAB 6L1 6L2 6L3
2-B5 4 SOLENOIDS AND SWITCH ADDED
BP 2-C4 XS10:10 WAS XS10:13, XS10:11 WAS XS10:14
U1 V1 W1 3-C5 CTO REMOVED FROM P2, K7 ADDED
DOOR W2 U2 V2 3-C8 106 WAS 105
FD1 3-B6 3SVB REMOVED. 3SV WAS 3SVA
3-C8 ARC SUPPRESSORS REMOVED FROM KM(1, 2, AND 3)
C FD2 5-C3 VIEWS "C" AND "F" UPDATED FOR HEATERS C
5-C8 12SVx ADDED TO LEGEND
MM 2-B5 H 1223466 SOLENOID 12SVd REMOVED 2017APR12 T.DOUGHER B.WARREN
2-D3 J 1242658 THIRD POLE ADDED TO MCB2 2017JUN06 T.DOUGHER B.WARREN
"B" 1-B5
2-C5
K 1269258 53 WAS 60 (2 x)
k7-1 WAS k7
2017SEP20 T.DOUGHERTY B.WARREN

3-B5 ADDED 315, 316, AND K7-2


06 5-B8 ADDED K7 - COMMON TRIP OUTPUT
5-A4 L 1271048 HEATERS ADDED TO LOW AMBIENT OPTION 2017OCT09 T.DOUGHERTY M.SULLIVAN
5-B4
5-A HEATER DESIGNATIONS ADDED TO LEGEND
5-C6 FUSES FU12 AND FU13 REPLACED MCB4

L1 L2 L3 L1 L2 L3
FU1,2,3 FU4,5,6
09 "A"
3L1 3L2 3L3
2L1 2L2 2L3 05
KM4 KM5
4L1 4L2 4L3 5L1 5L2 5L3
P3-5
L1 L2 L3 L1 L2 L3
208A GND GND
208 PE PE
K3-1 K3-2
FMP1 FMP2 500
BLU 283 12
BLU
13 13 12
B BLU 284 BLU 501 B
18 18
I> I> I> 14 I> I> I> 14
BLU 285 BLU 502
27 27
FD1 01 BLU 208 FD2
209 208
208A BLU 208A BLU 209
4L1 4L2 4L3 5L1 5L2 5L3 02 01 02 209
WHI 294 WHI 294
P3-6 BLK 296 42 53 2 - 294
53
KM4 KM5 297 BLK 295 BLK 295
55
BLK 55 2 - 295

U V W U V W PE PE

U V W U V W
U W V U W V

FM1 FM2
FM1 FM2

48957567 REV L
SHEET 1 OF 5

A A
STANDARD TOLERANCES WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED DO NOT SCALE DRAWING
BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS
NOTES: AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. DRAWING CONFORMS TO THIRD ANGLE PROJECTION
ALL DIMENSIONS ARE IN ASME Y14.5M - 1994
MILLIMETERS PROPRIETARY NOTICE DRAWN DATE

1. DECAL MUST CONFORM TO THE LATEST REVISION OF IR SPECIFICATION 92-8.95. [INCHES (IF SHOWN)] THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET CAD GENERATED DRAWING, N.VIJAY 2014SEP10
R

INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS NO MANUAL REVISIONS ALLOWED CHECKED DATE NAME
UNSPECIFIED TOLERANCES: GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION
AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE
AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY
UNLESS OTHERWISE SPECIFIED:
- REMOVE ALL BURRS AND SHARP CORNERS
B.WARREN
APPROVED
2014SEP10
DATE
SCHEMATIC, ELECTRICAL
WHOLE
ONE PLACE (.X)
:
:
1
0.5
INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY
THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION
THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS
- WELD SYMBOLS TO BE IN ACCORDANCE
WITH ANSI/AWS A2.4
B.WARREN 2014SEP10
DRAWING TYPE
WIRING (FS-SD) C HEM ATI
S C E, EL CTRCI AL WIRI NG( FS S- D)

SIZE ESTIMATED WEIGHT DWG NO. REVISION


TWO PLACE (.XX) : 0.25 EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET Detail Drawing
ANGLES (.X) : 1 INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO
RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL
COPYRIGHT @ 2017
Ingersoll Rand
NOMENCLATURE
48957567
(KG UNLESS OTHERWISE SPECIFIED)

A1 0.0 kilogram L 4895 7567

PART NO.
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. SCALE MODEL SHEET
Ingersoll-Rand Industrial Technologies ALL RIGHTS RESERVED 0.20 ARES 200-250 1 OF 5
For Internal Use:Model=48957567|PART|L.0|Thomas Dougherty|09-Oct-17 09:18:32 AM|Review<>Drawing=48957567|DRAW|L.3|Thomas Dougherty|12-Oct-17 02:36:54 PM|Design

8 7 6 5 4 3 2 1
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED L.3

52
8 7 6 5 4 3 2 1

1 - L3 L3
1 - L2 L2
D L1 D
1 - L1

MCB2
L1 L3 0.5A
L1 L3

MCB1 FU10,11 7L1 7L2 7L3


3A
1L1 1L3 1L1 1L3

L1
L2
L3
"D" K2

H6:220V
H5:230V
H4:380V
H3:415V
H2:460V
H1:575V
H7:0V
08
T1

N/O
N/C
C
X3:0V

X1:115V
150 100

102
105
MCB3
6A
RED
101
ES-1

102

C 04 C

105

XS10:10
KM1-2 K6-1 MCB5
3A
1ATS

XS10:11
121 104 CDV
X1
1.2 1.1

150 106
XS6:2 XS6:1
124 124 K7-1
106
103

XS10:12

XS10:15

XS10:18
PSU 1
XS7:1

XS10:4

(24Vdc) 115V

12SVa

12SVb

12SVc
L P1
PORO

200
4SV

2SV
RC4

BLU
+ 1 +

VDC
XS10:13

XS10:16

XS10:19
XS10:14
201

XS10:17

XS10:20
BLU/WHT
P10
- 2 -
XS10:5

XS10:6
XS7:2

XS7:3

CONT
B N B

RTDMON-J
RTDMON-I
WHT(UL)
GRN/YEL(EU)
150 P8
10 150 150
11 11 11

P7

294
CAP WHI
294 WHI 10 AO1
1 - 294
295 BLK 295 ZNR 9 AO+ P4
1 - 295
8 COM
BLK

48957567 REV L
SHEET 2 OF 5

A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL SCH
ALW IRING
EM
A TI
C (FS-SD)
,EL C
E T RIC

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-SD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 489575 67
PART NO.
48957567 L
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 0.20 SHEET 2 OF 5

8 7 6 5 4 3 2 1
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED L.3

53
8 7 6 5 4 3 2 1

DI3

DI3
D

V+

V+
D
5 6 5 6

208
209

208
209
09

14
FMP2
10

13
208A

14

14
FMP1 FMP1

13

13
CONT

P1 P2 P4 P3
115V

GND

DI15

DI16
TX1

TX2

TX3

TX4

TX5

TX6

TX7

TX8

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8

DI9
N/O

N/O
N/C

N/C

V+

V+

V+

V+

V+

V+

V+

V+

V+

V+

V+
V+

V+
V-

V-
C

C
C 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 29 30 31 32 C

122
123

308
309
310

207
208
209
106

110

296
297
298
299

204

210
211
212
213
214
215
216
217
218
219
220
221
202
203

232
233
234
235
114

114
113

114

115
112
111

116
***A***

KM1-1 KM3-1

206

02
TR-1
KM3-2 KM2-1 2 FD2

01
SEC

205

208A
118

119

120

114A

95

02
K7
A1
A1

KM5 A1
KM1 A1

KM2 A1

KM3 A1

A1
FD1
KM4

TR
K3

96

01
-

220
221
TRR
ES-2 FR1

K6
A2
A2

A2
A2

A2

A2

A2
106
04 "E"

-
150 150 150 150 150 150 150 150
106 150
13
XS10:1
XS10:3
XS10:2

XS10:7
XS10:9
XS10:8

XS5:1
XS5:2
XS9:4
XS9:6
XS9:5

XS9:1
XS9:3
XS9:2
XS8:1
XS8:3

XS8:2

K7-2

308
309
310

210
211
212
213
214
215
216
217
218
219

232
233
234
235
KM1-4 TRR-1
303

304

313

314
315

316
2.2 2.3
KL2
***B***

CDE
7SV A1

1SV A1

3SV A1

5SV A1

9SV A1

B B
A2

A2

A2

A2

A2

303 304 315 316 313 314


***C***

CWO RSP RST RLE RLU RLL AW1 AW2

48957567 REV L
SHEET 3 OF 5

A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL SC )HE MATI
SD C,E LECTR CAL
I WI RING( FS -

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-SD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 4895 7567
PART NO.
48957567 L
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 0.20 SHEET 3 OF 5

8 7 6 5 4 3 2 1
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED L.3

54
8 7 6 5 4 3 2 1

D D

278

COM3
7 A D-

P9
279

COMM
CONT 8 B D+ RTDMON
C GND
D INIT

P5 P6 PWR INPUT
ELECTRICAL CABINET

+5Vdc
+5Vdc

+5Vdc
+5Vdc
Sig10
Sig10
Sig11
Sig11
Sig12
Sig12

Sig13
Sig13
Sig14
Sig14
Sig15
Sig15
Sig16
Sig16
Sig1

Sig2

Sig3

Sig4

Sig5

Sig6

Sig7

Sig8

Sig9
Sig9

REF

REF

REF

REF

REF

REF

REF

REF
Gnd

Gnd

Gnd

Gnd

Gnd

Gnd

Gnd

Gnd

IN0

IN1

IN2

IN3

IN4

IN5

IN6

IN7
V+

V+

V+

V+

V+

V+

V+

V+

V+
V-
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 I J 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253

257
258
259

260
261
262
263
264
265

268
269

201
200

1R1
1R2
2R1
2R2
3R1
3R2
4R1
4R2
5R1
5R2
6R1
6R2
7R1
7R2
8R1
8R2
C C
RED

RED

RED

RED

RED

RED

RED
WHI

WHI

WHI

WHI

WHI

WHI

WHI

WHI

WHI

WHI

WHI
BLK

BLK

BLK

BLK

BLK

BLK

BLK

BLK

BLK

BLK

BLK

WHI

WHI

WHI

WHI

WHI

WHI

WHI

WHI
BLK

BLK

BLK

BLK

BLK

BLK

BLK

BLK
PSU VDC+
PSU VDC-
XS1:13
XS1:10

XS1:14
XS1:15
XS1:16
XS1:11
XS1:12

XS1:17
XS1:18

XS3:1
XS3:2
XS3:3
XS1:1
XS1:2
XS1:3
XS1:4
XS1:5
XS1:6
XS1:7
XS1:8
XS1:9

XS2:10
XS2:12
XS2:11
XS2:4
XS2:6
XS2:5

XS2:7
XS2:9
XS2:8
XS2:1
XS2:3
XS2:2
COMPRESSOR

T T T T T T T T T T T T
P P P P P P P 1ATT 2ATT 2CTT 4ATT 1R 2R 3R 4R 5R 6R 7R 8R
1AVPT 2APT 3APT 4APT 5CPT 6CPT 10APT

11
FIELD

B B

48957567 REV L
A SHEET 4 OF 5 A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL S D)
CHE AT
M IC,ELE CT CA
RI LWIRING (FS-

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-SD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 489575 67
PART NO.
48957567 L
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 0.20 SHEET 4 OF 5

8 7 6 5 4 3 2 1
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED L.3

55
8 7 6 5 4 3 2 1

LEGEND NOTES:
LABEL DESCRIPTION WIRE COLOR LEGEND
OV ZERO VOLTAGE
1ATS HIGH AIR TEMP SWITCH 1. APPROVED FUSED DISCONNECT OR CIRCUIT BREAKER PER LOCAL LABEL DESCRIPTION
D 1ATT PACKAGE INLET TEMPERATURE ELECTRICAL CODES MUST BE PROVIDED BY CUSTOMER. BLK BLACK D
1AVPT INLET VACUUM PRESSURE 2. INDICATES OPTIONAL COMPONENTS.
1AVPTH INLET HEATER 3. INDICATES OPTIONAL FIELD WIRED COMPONENTS. BLU BLUE
1HE MOTOR SPACE HEATER 1 BRO BROWN
1SV LOAD VALVE 4. REMOVE JUMPER(S) WHEN CORRESPONDING OPTION HAS BEEN PURCHASED.
1SVT 1SV HEAT TRACE 5. A VARIABLE SPEED DRIVE IS REQUIRED FOR UNITS WITH LOW AMBIENT, AND ENSURE GRE GREEN
2APT INTERSTAGE PRESSURE SWITCHES ST01 AND ST02 ARE ON. SEE DETAIL A.
2ATT AIREND DISCHARGE TEMPERATURE PIN PINK
2CTT INJECTED COOLENT TEMPERATURE
6. A THREE-PHASE AUTO-TRANSFORMER IS REQUIRED FOR LOW AMBIENT UNITS
RATED AT 575V/60HZ. SEE DETAIL B. RED RED
2HE MOTOR SPACE HEATER 2
2SV OIL STOP VALVE 7. THERMOSTAT AND TEMPERATURE SWITCH CONTACTS ARE NORMALLY CLOSED VIO VIOLET
3APT SUMP PRESSURE AND WILL OPEN WHEN THE TEMPERATURE MEETS OR EXCEEDS THE INDICATED WHI WHITE
3ATS AMBIENT TEMP THERMOSTAT
3SVx BLOWDOWN VALVE SETPOINT. SEE DETAIL C. YEL YELLOW
4APT PACKAGE DISCHARGE PRESSURE 8. FUSES 10 AND 11 ARE AN ACCEPTABLE ALTERNATE TO MCB1 AND REQUIRED
4ATT AFTERCOOLER DISCHARGE TEMP. WHEN LINE POWER IS 575V/60HZ. SEE DETAIL D. WIRE DESIGNATION LEGEND
4SV WATER SHUT OFF VALVE (W/C ONLY) 9. AIR COOLED UNITS ONLY.
5CPT OIL FILTER INLET PRESSURE
10. WATER COOLED UNITS ONLY. NUMBERS FUNCTION WIRE COLOR-EU STD WIRE COLOR-UL STD WIRE SIZE
5SV MODULATION VALVE
6CPT OIL FILTER OUTLET PRESSURE 11. TWO STAGE UNITS ONLY. 1 - 99 POWER BLACK BLACK A/R
7SV LOAD VALVE 12. SINGLE STAGE UNITS ONLY. 100 - 199 AC CONTROL RED RED 2
9SV DISCHARGE CONDENSATE SOLENOID VALVE 18 AWG (1mm )
10APT REMOTE PRESSURE 13. FAN MOTOR OVERLOAD FAULT INPUT ALTERNATE WIRING 2
FOR LOW AMBIENT OPTION. SEE DETAIL E. 100 - 199 GROUNDED AC GREEN / YELLOW WHITE 18 AWG (1mm )
12SVx E-STOP BLOWDOWN VALVE
AT1 AUTO TRANSFORMER 14. HEATER CIRCUIT, CUSTOMER SUPPLIED 120/1/60 OR 240/1/50. 200 - 299 DC CONTROL BLUE BLUE 2
18 AWG (1mm )
AW1 AUXILIARY WARNING 1 15. OUTDOOR MODIFICATION OPTION. SEE DETAIL F.
AW2 AUXILIARY WARNING 2 300 - 399 AUXILIARY RED / BLUE / BLACK ORANGE 2
16. MAIN MOTORS ARE 6-LEAD WITH PARALLEL CONDUCTORS. 18 AWG (1mm )
BLH BASE LEVEL HEATER
BP BACKPANEL TIE LEADS WITH THE SAME LABEL TOGETHER. 400-499 AC POWER ORANGE RED 2
18 AWG (1mm )
CAB CABINET
CAP CAPACITOR GND GROUNDED GREEN / YELLOW GREEN / YELLOW A/R
C C
CDE CONDENSATE DRAIN ERROR
CONT Xe CONTROLLER
CTO COMMON TRIP OUTPUT FU12 402
CWO COMMON WARNING OUTPUT 1L1
DEH DISCHARGE ELBOW HEATER
FU13 3ATS "C"
EB EARTHING BAR
ES EMERGENCY STOP BUTTON 1L2/N K4-1 (4 C / 40 F)
07
FDx FAN DRIVE 60A
FMx FAN MOTOR 406
FMH FAN MOTOR HEATER HEATER
FMPx
FR1
FUx
FAN MOTOR PROTECTOR
MAIN MOTOR OVERLOAD
FUSES
CIRCUIT,
CUSTOMER
KM1-3 KM1-5 LOW AMBIENT
404
IVH
K2
INLET VALVE HEATER
PHASE MONITOR RELAY
SUPPLIED
120/1/60 TH
OPTION
K3 BLOWER DRIVE CONTROL RELAY (29 C / 85 F)
K4 LOW AMBIENT CONTROL RELAY
K6 PORO CONTROL RELAY 1HE1 2HE1
K7 COMMON TRIP OUTPUT 403 403 403 403 403 403 403 403
405 403
KM1 MAIN CONTACTOR
KM2 DELTA CONTACTOR
KM3 START CONTACTOR

A1

1AVPTH

4APTH

6CPTH
3APTH

5CPTH
KM4 COOLING FAN MOTOR 1 CONTACTOR

FMH2

9SVH
OSH3
FMH

OSH2

7SVH
OSH1
BLH1

BLH2
1SVT

5SVH
DEH
RC5

K4
KM5 COOLING FAN MOTOR 2 CONTACTOR SSH SSH 1HE 2HE
MCBx CIRCUIT BREAKERS

A2
MM MAIN MOTOR
MSHT MOISTURE SEPARATOR HEAT TRACE
OSH OIL SUMP HEATER
PE PROTECTED EARTH 410 1HE2 2HE2
410 410 410 410 410 410 410 410
PORO POWER OUTAGE RESTART OPTION
B PSU POWER SUPPPLY UNIT 402 B
FU12
RCx ARC SUPPRESSOR 1L1
RLE REMOTE LOAD ENABLE
RLL REMOTE LEAD LAG FU13 3ATS
RLU REMOTE LOAD/UNLOAD 1L2/N K4-1 (4 C / 40 F)
RSP REMOTE STOP 30A
RST REMOTE START 406
1R MOTOR WINDING RTD HEATER
2R MOTOR WINDING RTD
3R MOTOR WINDING RTD CIRCUIT, KM1-3 KM1-5
4R MOTOR WINDING RTD CUSTOMER
SUPPLIED 404
5R MOTOR WINDING RTD
6R MOTOR WINDING RTD 230/1/50 TH
7R MOTOR DE BEARING RTD (29 C / 85 F) 1HE1
8R MOTOR DE BEARING RTD
RTDMON MOTOR RTD MONITOR
SSH STARTER SPACE HEATER 1HE 403 403 403 403 403 403 403 403 403
T1 CONTROL POWER TRANSFORMER 405
TH THERMOSTAT 1HE2
TR TIMING RELAY
A1

1AVPTH

4APTH

6CPTH
3APTH

5CPTH
TRM POWER TERMINAL
FMH2

9SVH
OSH3
OSH2

7SVH
OSH1
BLH1
FMH1

BLH2
1SVT

5SVH
DEH
RC5

K4

2HE1
TRR COMPRESSOR RUNNING LOADED RELAY SSH SSH
xAPTH HEATER FOR #APT
A2

xCPTH HEATER FOR #CPT 2HE


xSVH HEATER FOR #SV
XSx HARNESS CONNECTOR 48957567 REV L
2HE2
ZNR ZENER DIODE 410 410 410 410 410 410 410 410 410
SHEET 5 OF 5

A A

PROPRIETARY NOTICE NAME


THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET
INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND SCHEMATIC, ELECTRICAL SCH EMATC,IEL EC TRIC
A L WIR N
I G(FS- SD)

IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY


RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE
DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS
WIRING (FS-SD)
AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1)
NOT USE THE DRAWING OR ANY COPY THEREOF OR THE SIZE DWG NO. REVISION
CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT
COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE
DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION
THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN
A1 489 57567
PART NO.
48957567 L
THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL SCALE NOMENCLATURE
COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. 0.20 SHEET 5 OF 5

8 7 6 5 4 3 2 1
UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED L.3

56

You might also like