PRODUCT CATALOGUE

AHU N° 17.04.016
Range AHU MANDÍK
2
Content
Fire-Fighting Technologies . . . . . . . . . . . . . . . . . . . . . . . 3
Content

Smoke extraction technologies . . . . . . . . . . . . . . . . . . . . .7


Air Regulation Technologies . . . . . . . . . . . . . . . . . . . . . . 9
Distribution Elements . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Other HVAC Components . . . . . . . . . . . . . . . . . . . . . . . 20
Air-handling Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Industrial heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Special Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Fire-Fighting Technologies 3

FDMA (TPM 018/01)

Fire-Fighting Technologies
Fire damper
EI120, EI90 (ve, ho i  o)S

• Square dampers from 180 × 180 mm • Corrosion resistant acc. to EN 15650


to 1 600 × 1 000 mm • Cycling test in class C 10000 acc. to
• Round dampers from ø 180 to 1 000 mm EN 15650
• certified acc. to EN 15650 • Damper actuating mechanical, or
• Tested in accordance with EN 1366-2 electrical
• Classified acc. to EN 13501-3+A1 • Maximum air speed through opened
damper of 12 m/s and pressure
• Fire resistance up to EIS 120
difference 1 200 Pa
• External casing leakage class C, Inter-
• Can be used in explosion-hazardous
nal leakage class 2 acc. to EN 1751
environments

FDMB (TPM 075/09)


Fire damper
EI120, EI90 (ve, ho i  o)S

• Square dampers from 160 × 160 mm • External casing leakage class C,


to 0,5 m2 (max. dimensions Internal leakage class 2 acc. to EN 1751
1 000 × 500 mm) • Corrosion resistant acc. to EN 15650
• Round dampers from ø 160 to • Cycling test in class C 10000 acc. to
630 mm EN 15650
• certified acc. to EN15650 • Damper actuating mechanical, or
• Tested in accordance with EN 1366-2 electrical
• Classified acc. to EN 13501-3+A1 • Maximum air speed through
• Fire resistance up to EIS 120 opened damper of 12 m/s and
pressure difference 1 200 Pa

FDMC (TPM 083/12)


Fire damper
EI60 (ve, ho i  o)S

• Round dampers from ø 100 to • Corrosion resistant acc. to EN 15650


400 mm • Cycling test in class C 10000 acc. to
• certified acc. to EN15650 EN 15650
• Tested in accordance with EN 1366-2 • Damper actuating electrical
• Classified acc. to EN 13501-3+A1 • Maximum air speed through opened
• Fire resistance up to EIS 60 damper of 12 m/s and pressure
difference 1 200 Pa
• External casing leakage class C,
Internal leakage class 2 acc. to
EN 1751
4

FDMD (TPM 092/13)


Fire-Fighting Technologies

Fire damper
EI120, EI90 (ve, ho i  o)S

• Round dampers from ø 100 to • Corrosion resistant acc. to EN 15650


200 mm • Cycling test in class C 10000 acc. to
• certified acc. to EN15650 EN 15650
• Tested in accordance with EN 1366-2 • Damper actuating mechanical, or
• Classified acc. to EN 13501-3+A1 electrical
• Fire resistance up to EIS 120 • Maximum air speed through
opened damper of 12 m/s and
• External casing leakage class C,
pressure difference 1 500 Pa
Internal leakage class 2 acc. to
EN 1751

FDMS (TPM 092/13)


Fire damper
EI60 (ve, ho i  o)S

• Round fire damper - in diameters • Cycling test in class C 10 000 acc. to


from 100 mm up to 630 mm EN 15650
• certified acc. to EN 15650 • Corrosion resistant acc. to EN 15650
• Tested in accordance with EN 1366-2 • Damper´s actuating mechanism
• Classified acc. to EN 13501-3+A1 – electrical
• Fire resistance EIS 60 • Maximum air speed – 12 m/s
• External casing leakage class min. C, • Pressure difference 1 200 Pa
internal leakage class 2 acc. EN 1751

CFDM (TPM 118/16)


Fire damper
EI120, EI90, EI60 (ve i  o)S, EI120 (ve, ho i  o)S

• Round dampers 100, 125, 160, • Internal leakage class 2 acc. to


200 mm EN 1751
• certified acc. to EN15650 • Corrosion resistant acc. to EN 15650
• Tested in accordance with EN 1366-2 • Maximum air speed through opened
• Classified acc. to EN 13501-3+A1 damper of 12 m/s and pressure
difference 1 200 Pa
• Fire resistance up to EIS 120
5

BSK-J

Fire-Fighting Technologies
Fire damper
EI90 (ve, ho i  o)S

• Dimensions from 100 × 150 to • External casing leakage class B,


1 000 × 1 050 mm ­Internal leakage class 2 acc. to
• certified acc. to EN15650 EN 1751
• Tested in accordance with EN 1366-2 • Cycling test in class C 10000 acc. to
EN 15650
• Classified accto EN 13501-3+A1
• Damper actuating electrical
• Fire resistance up to EIS 90
• Maximum air speed through
openeddamper of 15 m/s and
­pressuredifference 1 200 Pa

PSUM (TPM 006/99)


Multi-leaf fire shutter

• The fire shutter (without • Dimensions from 200 × 215 mm


connecting ducts) in fire section to 600 × 815 mm
dividing constructions prevents the • Casing made of galvanized
spread of fire and smoke steel, the shutter blades made of
• Fire resistance EI 90 DP1 calcium-silicate insulation material
• For vertical and horizontal Fire • Cover grill coated by RAL 9010
dividing constructions
• Can be used in explosion-hazardous
environments

PVM (TPM 052/05)


Fire valve

• Equipment preventing the spread • Fire resistance E 90 / EW 90


of fire and smoke in ventilation and • Diameter in mm: 100, 125, 160, 200
air-conditioning systems
• Airflow volume from 20 to 300 m3/h
• May be installed independently or
• Valve casing made of galvanized
serve for inflow and outflow of air
steel, body and valve plate
6

SMRF (TPM 091/13)


Fire-Fighting Technologies

Duct silencer

• Connection diameters from • Acoustic tested acc. to EN ISO 11691


80 to 500 mm • Fire resistance classified acc. to
• Spiro design with blade sealing EN13501-3+A1 as EI30 without
• Fire resistance tested acc. protective distance
to EN1366-1 • Maximum air speed of 12 m/s and
• Tightness tested acc. to EN 12237 pressure difference 1 500 Pa
• Insulation thickness 50 mm

DM-S (TPM 095/13)


Fire Damper without thermal isolation
E30 (ve, ho i  o)S

• Round dampers from ø100 to • Tested in accordance with EN 1366-2


630 mm • Classified acc. to EN 13501-3+A1
• Completely made of galvanized steel • Fire resistance up to ES 30
• Electrical actuating mechanism • Maximum air speed through opened
• CE certified acc. to EN 15650 damper of 12 m/s and p ­ ressure
difference 1 200 Pa
Smoke extraction technologies 7

SEDS (TPM 086/12)

Smoke extraction technologies


Single smoke damper
E60090(ve-i  o)S1000C300AAsingle

• Square dampers from • Cycling test in class C 10000


180 × 180 mm to 1 600 × 1 000 mm acc. to EN 15650
• certified acc. to EN12101-8 • Damper actuating by
electrical actuator
• Tested in accordance with EN 1366-10
• Max. air speed in the system
• Classified acc. to EN 13501-4+A1 as
of 15 m/s, allowed pressure up to
ES90/600, actuating AA for one Fire
500 Pa, or under pressure up
Compartment
to - 1 000 Pa
• External casing leakage class C,
Internal leakage class 2 acc. to
EN 1751

SEDS-R
Single compartment smoke extraction damper
with manual and automatic actuations
E600 120(ve-i   o)S1500C10000MAsingle

• Round dampers with diameters from • Cycling test in class C 10 000 acc. to
ø 100 to 630 mm EN 12101-8
• certified acc. to EN12101-8 • Damper actuating by electrical actua-
• Tested in accordance with EN 1366-10 tor
• Classified acc. to EN 13501-4+A1 as • Max. air speed in the system of
ES 90/600, actuating MA and AA for 15 m/s, allowed pressure up to
one Fire Compartment 500 Pa, or under-pressure up to –
1500 Pa
• External Casing leakage class B, Inter-
nal leakage class 3 acc. to EN 1751

SEDS-L
Single compartment smoke extraction damper
with manual and automatic actuations
E600 120(ve-i   o)S1500C10000MAsingle

• Square dampers from size • Cycling test in class C 10 000 acc. to


200 × 200 mm to 1200 x 1200 mm EN 12101-8
• certified acc. to EN12101-8 • Damper actuating by electrical
• Tested in accordance with ­actuator
EN 1366-10 • Max. air speed in the system of
• Classified acc. to EN 13501-4+A1 as 12 m/s, allowed pressure up to
ES90/600, actuating MA and AA for 500 Pa, or under-pressure up to
one Fire Compartment – 1500 Pa
• External Casing leakage class C,
­Internal leakage class 2 acc. to
EN 1751
8

SEDM (TPM 087/12)


Smoke extraction technologies

Multi smoke damper


EI120(vew, ved, how, hod-i   o)S1500C10000AA or MA multi

• Square dampers from • Cycling test in class C 10000 acc. to


180 × 180 mm to 1 600 × 1 000 mm EN 15650
• certified acc. to EN12101-8 • Damper actuating by electrical
• Tested in accordance with EN 1366-10 actuator
• Classified acc. to EN 13501-4+A1 • Max. air speed in the system of
as EIS 120, HOT400/30, actuating 15 m/s, allowed pressure up to
AA/MA for multi Fire Compartment 500 Pa, or under pressure up
to -1500 Pa
• External casing leakage class B,
Internal leakage class 2 acc. to
EN 1751

MSD (TPM 109/15)


Multi smoke damper
EI120(vew, how-i   o)S1500C10000AA multi

• Square dampers from 160 × 180 mm • Damper actuating by electrical actu-


to 1 500 × 800 mm ator for smoke dampers Cycling test
• Round dampers from ø 180 to 630 mm in class C 10000 acc. to EN 15650
• certified acc. to EN12101-8 • Damper actuating by electrical actu-
ator with return spring and solenoid
• Tested in accordance with EN 1366-10
Cycling test in class C 10000 with no
• Classified acc. to EN 13501-4+A1as additional load
EIS 120, actuating AA for multi Fire
• Max. air speed in the system of
Compartment
15 m/s, allowed pressure
• External casing leakage class C up to 500 Pa, or under pressure
• Internal leakage class 2 acc. to EN 1751 up to -1500 Pa

BRK-J (TPM 115/15)


Multi smoke damper
EI90 (vedw, hodw i  o)S1000C10000HOT400/300AAmulti

• Square dampers from 100 × 150 to • Cycling test in class C 10000 acc. to
1000 × 1050 mm EN 12101-8
• Certified acc. to EN12101-8 • Damper actuating by electrical
• Tested in accordance with EN 1366-10 actuator
• Classified accto EN 13501-4+A1 as • Max. air speed in the system of
EIS90, HOT400/30, actuating AA for 15 m/s, allowed pressure up to
multi Fire Compartment 500 Pa, or under pressure up to
- 1 000 Pa
• External casing leakage class B,
Internal leakage class 2 acc. to
EN 1751
Air Regulation Technologies 9

RPM-V (TPM 085/12)

Air Regulation Technologies


Round variable airflow regulator

• For regulation of variable or constant • Internal leakage up to class 3 acc.


airflow volume in HVAC systems to EN 1751
• Diameter from 80 to 630 mm • Each regulator is equipped with
• Airflow volume from 35 to an airflow pressure probe and
5 800 m3/h electrical actuating
(Belimo LMV-D3 MP, or NMV-D3-MP,
• Made of galvanized steel
power supply 24 V, control power
• External casing leakage up to class C 0 –10 V, or 2 – 10 V)
acc. to EN 1751

RPM-K (TPM 094/13)


Round constant airflow regulator

• For maintaining and regulation • Casing and actuating mechanism


of constant airflow volume in made of galvanized steel, leaf
HVAC systems made of aluminium, leaf axe,
• Diameter from 80 to 400 mm bearings and spring made of
austenitic steel
• Airflow volume from 100
to 4 000 m3/h
• External casing leakage up to class B
acc. to EN 1751

RPMC-V (TPM 106/14)


Square variable airflow regulator

• For regulation of variable or constant • Internal leakage up to class 3 acc. to


airflow volume in HVAC systems EN 1751
• Regulator dimensions from • Each regulator is equipped with an
200 × 100 to 1000 × 1000 mm airflow pressure probe and electri-
• Airflow volume from 90 to cal actuating (Belimo LMV-D3 MP,
43 000 m3/h or NMV-D3-MP, power supply 24 V,
control power 0 –10 V, or 2 – 10 V)
• External casing leakage up to class C
acc. to EN 1751 • Made of galvanized steel
10

RPMC-K (TPM 105/14)


Air Regulation Technologies

Square constant airflow regulator

• For maintaining and regulation of • Airflow volume from 250 to


constant airflow volume in HVAC 12 000 m3/h
systems • Casing and actuating mechanism
• Regulator dimensions from 200 × made of galvanized steel, leaf made
100 to 600 × 600 mm of aluminium, leaf axe, bearings and
• External casing leakage up to class C spring made of austenitic steel
acc. to EN 1751

RKM (TPM 009/00)


Square regulation/adjustment damper

• For regulation of airflow inside • Damper actuating mechanical,


the duct or electrical
• Manual or electrical actuating • Made of galvanized steel
• Can be used in explosion-hazardous • Leaf width always 100 mm
environments • Includes a flange for connection
• Damper dimensions from to the duct
200 × 200 mm to 2 000 × 2 000 mm

RKTM (TPM 012/00)


Square tight regulation/adjustment damper

• For regulation and airflow cut off • Damper actuating mechanical,


inside the duct or electrical
• Manual or electrical actuating • Made of galvanized steel
• Can be used in explosion-hazardous • Leaf width always 100 mm
environments • Includes a flange for connection
• Damper dimensions from to the duct
200 × 200 mm to 2 000 × 1 600 mm
11

RKKM (TPM 030/03)

Air Regulation Technologies


Round regulation/adjustment damper

• For regulation of airflow inside • Diameter from 80 to 630 mm


the duct • Damper actuating mechanical,
• Manual or electrical actuating or electrical
• Can be used in explosion-hazardous • Made of galvanized steel
environments • Includes a flange for connection to
the duct, SPIRO design also available

RKKTM (TPM 031/03)


Round tight regulation/adjustment damper

• For regulation and airflow cut off • Diameter from 80 to 630 mm


inside the duct • Damper actuating mechanical,
• Manual or electrical actuating or electrical
• Can be used in explosion-hazardous • Made of galvanized steel
environments • Includes a flange for connection to
the duct, SPIRO design also available

RKALM
Square regulation/adjustment damper

• For regulation of airflow inside the • Internal leakage class 2, 3 acc to


duct EN 1751
• Manual or electrical actuating • Coefficient of thermal transmission
• Damper dimensions from per blade up to 2,99 W/m2.K
• 200 × 200 mm to 2 000 × 2 000 mm • Damper actuating mechanical,
or electrical
• Made of aluminium
• Includes a flange for connection to
• Leaf width always 100 mm
the duct
12
Distribution Elements
VVM (TPM 001/96)
Distribution Elements

Whirling air outflow outlet

• Installation into ceiling or suspended • Installation height from 2,6 to 4,0 m


below ceiling • For heating and cooling with
• For offices, cinemas, shopping Δtp ≤ -14 K
centers, etc. • Adjustable plastic blades for
• Airflow volume from 55 to directing of airflow
1 200 m3/h • Galvanized plenum box
• Size A × B in mm: 300, 400, 500, 600, • Front panel coated by RAL 9010
625, 825

VVDM (TPM 089/12)


Whirling air outflow outlet

• Installation into ceiling or suspended • Installation height from 2,5 to 4,0 m


below ceiling • For heating and cooling
• For offices, cinemas, shopping with Δtp ≤ -12 K
centers, etc. • Adjustable plastic blades for
• Airflow volume from 150 to directing of airflow
1 500 m3/h • Galvanized plenum box
• Size A × B in mm: 300, 400, 500, 600, • Front panel coated by RAL 9010
625, 825

VVPM (TPM 007/99)


Whirling air outflow outlet with fixed blades

• Installation into ceiling or suspended • Installation height from 2,6 to 4,0 m


below ceiling • For heating and cooling with
• For offices, cinemas, shopping Δtp ≤ -14 K
centers, etc. • Galvanized plenum box
• Airflow volume from 120 • Front panel coated by RAL 9010
to 600 m3/h
• Size A × B in mm: 300, 400, 500,
600, 625
13

ALCM (TPM 003/97)

Distribution Elements
Anemostat diffuser

• Installation into ceiling or suspended • Installation height from 2,6 to 4,0 m


below ceiling • For heating and cooling with
• For offices, cinemas, restaurants, Δtp ≤ -8 K
shopping centers, etc. • Supplied air is separated into four
• Airflow volume from 110 to sides perpendicular one to each
1 800 m3/h other
• Size A × B in mm: 250, 300, 400, 500, • Galvanized plenum box
600, 625 • Front panel coated by RAL 9010

ALKM (TPM 005/99)


Round Anemostat diffuser

• Installed into ceiling or suspended • Installation height from 2,6 to 4,0 m


below ceiling • For heating and cooling with
• For offices, cinemas, restaurants, Δtp ≤ -8 K
shopping centers, etc. • Supplied air is separated into four
• Airflow volume from 110 sides perpendicular one to each
to 1800 m3/h other
• Diameter in mm: 250, 300, 400, 500, • Galvanized plenum box
600, 625 • Front panel coated by RAL 9010

VASM (TPM 017/01)


Whirling anemostat with adjustable blades

• Installed into lowered ceiling or • Change of air outflow direction


suspended below ceiling (vertical, diagonal, horizontal)
• For industrial environment possible
– manufacturing halls, warehouses, • Remote change of air outflow
shopping centers, etc. possible by using of BELIMO
• Airflow volume from 350 to actuator
2 400 m3/h • High induction of air supply in
• Diameter in mm: 315, 400, 630 ventilated space
• Installation height over 3,8 m • Galvanized plenum box
• For heating with Δtp ≤ 15 K and • Front panel coated by RAL 9010
cooling with Δtp ≤ -10 K
14

VAPM (TPM 010/00)


Distribution Elements

Whirling anemostat with fixed blades

• Option of setting heating/cooling • Installation height from 2,6 to 4,0 m


using slide out by mid section • For heating and cooling with
• Installed into lowered ceiling or Δtp ≤ -10 K
suspended below ceiling • High induction of air supply in
• For offices, cinemas, restaurants, ventilated space
shopping centers, etc. • Galvanized plenum box
• Diameter, or A × B dimension in mm: • Front panel coated by RAL 9010
125, 160, 200, 250, 315, and 400
• Airflow volume from 30 to 900 m3/h

VAPM-L (TPM 082/11)


Whirling anemostat with fixed blades – linear

• Installation to aprons, ledges, steps, • For heating and cooling with


or stairs Δtp ≤ 5 K
• For offices, cinemas, restaurants, • Possibility of additional whirling
shopping centers, etc. equipment addition
• Dimensions related with amount of • Galvanized plenum box
outlets 1–6 • Front panel coated by RAL 9010
• Airflow volume from 6 to 100 m3/h
• Installation height from 15 to 30 mm
above the floor

EKOBOX (TPM 037/04)


Plenum box for front panels

• Standard, or optionaly with • Horizontal installation with


possibility of airflow setting in case adjustable flap
of installed front panel • Determined for square front panels
• Size A × B in mm: 250, 300, 400, type VVM, VVPM,VVDM, ALCM and
500, 600 ALKM
• Economic design for air supply • Galvanized steel
15

TVOM, TVPM (TPM 028/03)

Distribution Elements
Dish valve

• For exhaust (TVOM) and supply • Airflow volume from 20 to 250 m3/h
(TVPM) of air from toiletes, • Diameter in mm: 100, 125, 160, 200
bathrooms and other smaller spaces,
• Made of steel, RAL 9010 coated
installed into lowered ceilings

SDL (TPM 110/15)


Slot diffuser linear

• For supply and removal of air • Variable lenght


• Steady air stream across the entire • Anodized aluminum profile. Alterna-
length of the vent tively, electrostatic painting. The fins
• Number of slot outlets from 1 to 6 are made of black or white plastic.

DVCM
Air diffuser with perforated front plate intended for air supply
or air exhaust, with excellent out-look when installing into
suspended ceiling with square gypsum sound attenuating
cassettes.

• Sizes A × B in mm: • Galvanized plenum box


250, 300, 400, 500, 550 • Front panel – standardly powder
• Installation height from 2,6 to 4,0 m coated in RAL 9010
• For heating and cooling
16

VPVM (TPM 013/01)


Distribution Elements

Large area vent

• For supply of air to work areas • For supply of air colder by 1 to 3 °C


in offices, industrial buildings, than surrounding temperature
laboratories with high temperature • Round, wall mounted or corner
demand or dangerous air pollution design options
– small speeds of air flow in work
• Supply of air in space widens out
areas
from the floor utilizing convection
• Airflow volume from 500 to streams
8 100 m3/h
• Made of stainless steel, or RAL 9010
coated surface

KMM (TPM 002/96)


Covering/protection grille

• For covering of gaps and outlets on • Made of steel, RAL 9010, or


ducts, preventing entry of objects 9006 coated
• Effective surface area approx. 78 % • Round or square shape

SMM, SMPM (TPM 014/01, TPM 035/04)


Wall mounted grilles

• Made of anodized aluminum or • Supply and extraction of air in


galvanized steel cinemas, shopping centers, halls,
• Independent wall grilles (SMM) garages, etc.
and band wall grilles (SMPM) for • Airflow volume from 100
placement in four-sided duct or to approximately 5 000 m3/h
onto wall
17

VNM (TPM 015/01)

Distribution Elements
Adjustable vent

• Made of anodized aluminum or • Supply and extraction of air in


galvanized steel cinemas, shopping centers, halls,
• For placement in four-sided duct or garages, etc.
onto the wall • Air flow volume from 100 to
• Adjustable airflow direction by approximately 5 000 m3/h
setting of variable leaf angle • Elective regulation device for
airflow and pressure loss setting

SVM (TPM 016/01)


Wall vent

• Made of anodized aluminum or • Supply and extraction of air in


galvanized steel cinemas, shopping centers, halls,
• For placement in four-sided duct garages, etc.
or onto the wall • Airflow volume from 100 to
• Adjustable airflow direction by approximately 5 000 m3/h
setting of variable leaf angle • Elective regulation device for airflow
and pressure loss setting

VNKM (TPM 034/04)


Adjustable vent for round duct

• For placement onto round duct • Adjustable airflow direction by


• Supply and extraction of air in setting of variable leaf angle
cinemas, shopping centers, halls, • Elective regulation device for
garages, etc. airflow and pressure loss setting
• Airflow volume from 100 to • Vent frame made of galvanized
approximately 5 000 m3/h steel; blades are made of aluminum
profiles
18

RAG45 (TPM 107/15)


Distribution Elements

Grille with blades in 45 °

• Extraction of air in cinemas, • Air flow volume from 100


shopping centers, halls, garages, to approximately 5 000 m3/h
hotel rooms, etc. • Elective regulation device for airflow
• For placement in rectangular duct and pressure loss setting
or onto the wall • Made of anodized aluminum

VNMI (TPM 111/15)


Inox adjustable vent

• Supply and extraction of air in • Air flow volume from 100


cinemas, shopping centers, halls, to approximately 5 000 m3/h
garages, etc. • Elective regulation device for airflow
• For placement in four-sided duct or and pressure loss setting
onto the wall • Made of stainless steel sheet

DDM II (TPM 072/08)


Long-reach nozzle
• Air distribution over long distances • For heating with Δtp ≤ 25 K and
• Intended for placement into wall or cooling with Δtp ≤ -14 K
ceiling • Manual or electrically actuated
• For large halls, theaters, concert halls readjustment of airflow
direction (±25 °)
• Airflow volume from 40 to
2 400 m3/h • High output speed for airflow
• Diam. in mm: 100, 125, 160, 200, • Coated by RAL 9010
250, 315, and 400
19

PDZM (TPM 079/10)

Distribution Elements
Rain protection louvre

• For air supply and exhaust • Bird and insect protection net
• Hidden fixing, or openings for available
fixing screws in corners • Fitting with G2 filter possible
• Reinforcement and installation • Frames and lamellae made of
frame, or in-built (inset) frame galvanized steel as basic design
• Dimensions from 200 × 200 to • Coating by elective RAL available
2 000 × 2 000 mm
20
Other HVAC Components
TVM (TPM 003/96)
Other HVAC Components

Damping pad

• The damping pad is used to restrict • Width of pad flange 30 mm


the transfer of dynamic forces • Round or square shape
created by fan vibrations from units
• Pads are determined for ducts in
Group 1

NKTM (TPM 090/13)


Non-return damper, overpressure damper

• Dimensions from 200 × 200 • Mechanical damper used for air


to 1 400 × 1 400 mm backflow effect elimination
• Max. pressure difference 1 500 Pa, • Damper complete made of
max. airspeed inside the duct 12 m/s galvanized steel

DM-E (TPM 084/12)


Evacuative (decompression) damper

• Dimensions from 100 × 100 to • Damper complete made of


1 200 × 600 mm, galvanized steel, always equipped
round ø100 – 630 mm by el. actuator
• Max. pressure difference 1 200 Pa, • Fire classification as E30 ve,
max. airspeed inside the duct 12 m/s ho (io)S acc. to EN 13501-3
• Damper for opening of Smoke
extraction duct and overpressure
release
21

SMR (TPM 112/15)

Other HVAC Components


Silencer

• Connection diameters from 80 to • Maximum air speed of 12 m/s


800 mm andpressure difference 1 500 Pa
• Spiro design with blade sealing • Insulation thickness 50 mm or
100 mm
22
Air-Handling Units
Air-handling unit
Air-Handling Units

MANDIK
• Modular air handling units are • They were tested in “TUV Sud” labo-
intended for central distribution ratory.
and conditioning of air in industrial, • Mechanical strength of casing: D1 (M)
residential and commercial applica-
• Class leakages casing: L1 (M)
tions. They feature high efficiency
of air distribution and conditioning. • Filter bypass leakage: 0.5% - F9 (M)
They offer air flow volume from 500 • Thermal transmittance: T3
to 100 000 m3/h. They are complete- • Thermal bridging of the casing: TB2
ly designed and certified in a unique
• Certified by Eurovent, with possibili-
frameless casing. High design
ty to design AHU in particular energy
variability allows the customized
classes up to “A+” and ability to issue
solutions.
„Energy efficiency label“
• Modular AHU Mandík were suc-
cessfully tested and certified with
regards to Eurovent, RLT and ErP
regulations.

Air handling unit MANDIK


with heat pump
• Airflow volume from 500 to • Integrated refrigeration cycle with or
25 000 m3/hod without reversible operation
• Based on Range M and P • Environmentally friendly refrigerant
• Member of RLT, the possibility of the R410A or R407C
proposal in the energy classes up to • Comfort operation control by means
A+ of the Siemens Climatix controller
• Certified acc. 2004/108/ES (EMC) • Attention paid to high quality of
and 2006/95/ES (LVD) proven and certified purchased
components
23

MaR

Air-Handling Units
Control system

• System design for any variant of the • Easy control and full service
Mandík air handling unit assembly setting by means of the display
• Comfort operation control by means and push-buttons on the controller
of the Siemens Climatix controller • Metallic or plastic switchboards
• Certified acc. 2004/108/ES (EMC) depending on the air handling unit
and 2006/95/ES (LVD) configuration
• Extensive communication functions
– collaboration with most of the
superior systems

Compact air handling unit


MANDIK CPV
• Air-handling unit for air transport • Mechanical performance of casing
and air treatment in air-conditioning acc. to EN 1886
systems • Indoor design
• Range CPV 12 – CPV 60 • Equipment type Plug&Play
• Airflow volume from 500 to – ­integrated Control system
6800 m3/hod • Counterflow heat exchanger
• Member of RLT • Heat exchanger (water, electrical,
• Units fulfill requirements acc.to condensator)
EN 13 053 • EC fans with high efficiency
• Fulfill requirements of EcoDesign
2016 and 2018

Air-conditioner MANDÍK KFR

A+++
• heating , cooling and dehumidifi- • cleaning of the supplied air with
cation of the air in the room of the highly effective filtration
surface up to 23 m2 • Energy class A++ for cooling,
• low operational costs, due to inverter A+ to A+++ for heating
technology
24
Industrial Heating
HELIOS Manual 15/11
Industrial Heating

Infra-red radiant heater – gas fired

• Burning natural gas (G20), propane • Option of single stage, or double


(G31), propane-butane (G30/G31) stage burner design
• Heat output from 6,2 to 90 kW • Own control box OI, OID or
• Several construction designs possibility of SIEMENS central
regulation system connection
• Differentiated by heat output, design
of burner box, reflector construction
and shape of heating tubes

MONZUN (TPM 040/05)


Hot-air unit – gas fired

• VH model (with axial fan) or CV • Available as: single stage, double


(with radial fan) stage and modulated output
• Burning natural gas (G20), propane (continuous output regulation)
(G31), propane-butane (G30/G31) • Control boxes OM, OMD, Remon or
• Heat output from 6,5 to 92,8 kW possibility of SIEMENS central regu-
with air flow volume from 550 to lation system connection
9 000 m3/h
• Wall-mounted or hanged below
the ceiling

MONZUN – RTI (TPM 041/05)


Gas fired hot-air unit equipped by mixing chamber

• VH RTI model (with axial fan) or CV • Control boxes OM, OMD, Remon or
RTI (with radial fan) possibility of SIEMENS central regu-
• Burning natural gas (G20), propane lation system connection
(G31), propane-butane (G30/G31) • Control of mixing chamber manual
• Available as: single stage, double or servo actuated – setting of
stage and modulated output outside and inside air intake 0 –100 %
(continuous output regulation) • Heat output from 6,5 to 92,8 kW
with air flow volume from 550 to
8 000 m3/h
25

MONZUN – EUROKLIM (TPM 043/05)

Industrial Heating
Gas fired hot-air unit without fan
(determined for HVAC assemblies)

• Without fan • Heat output from 6,5 to 92,8 kW


• Burning natural gas (G20), propane with air flow volume from 550 to
(G31), propane-butane (G30/G31) 8 000 m3/h
• Design options – indoor/galvanized • Equipped by flanges for HVAC duct
/outdoor connection on intake/out-take side
• Designed for heat output
modulation (continuous regulation
from min. to max. value)

MONZUN – TE (TPM 063/07)


Hot-water air heater

• Available in three sizes, from single • Heat output from 9,6 to 88,7 kW with
to four row heating coils air flow volume from 1 500 m3/h to
• On-wall or under-ceiling mounting 7 800 m3/h
• Connection of mixing chamber and • Water Heated:
other accessories possible – tmax = 100 °C, pmax = 1,4 MPa

Monzun – TEC (TPM 063/07)


Air heater with cooling capability

• Available in three sizes, from three to • Cooling power from 6,2 to


four row heating coils 20,9 kW And Airflow volume
• Thermal heat output from 24,8 to from 1 500 m3/h bis 4 000 m3/h
68,8 kW And Airflow volume from • Wall design
1500 to 4000 m3/h
26

EXHAUST/COMBUSTION
Industrial Heating

AIR SUPPLY FITTINGS (TPM 047/05)


• Certified system for Combustion Air • Stainless steel ø 80 – 150 mm
supply and Exhaust (chimney flues • Aluminium based alloy
and fittings) ø 80 – 150 mm
• Horizontal or vertical installation

STRATIFIER (TPM 048/05)


Ceiling fan

• Three sizes depending on required


air output
• Increases economy of heating in
combination with hot-air heating
units

AIRSTREAM (TPM102/14)
Gate curtain

• Two sizes based on the air output


• Gate curtain is device intended
to separate indoor and outdoor
environment in gates of industrial
buildings
Special Applications 27

PKTMB – 120

Special Applications
Fire damper resistant against seismic events,
effects of high pressure and higher airflow velocity

• Min. dimensions 200 × 200 × 450; • Plain bearings – maintenancefree


max. dimensions design resistant to high-level
1 400 × 1 000 × 450 mm (square seismic stresses
cross-section only, round adapter • Max. airflow 20 m/s
available)
• Max. pressure difference 6 600 Pa
• certified acc. to EN15650 (inner pressure / external pressure
• Tested in accordance with EN 1366-2 – dynamic pressure)
• Classified acc. to EN 13501-3+A1 • Turbulent flow inside the duct is
• Fire resistance EIS 120 permissible, the damper can be
operated (opened, closed) under
• External casing leakage class C,
airflows up to 20 m/s, pressure up
Internal leakage class 2 acc. to EN 1751
to 6 600 Pa and concurrent seismic
• Corrosion resistant acc. to EN 15650 event (EDB, APC)
• Cycling test in class C 10000 acc. to • Seismic resistance defined as per
EN 15650 RRS (EDB, APC) applicable to the
• Damper actuating mechanical, site – tested to peak acceleration
electrical, pneumatical, or above 10 G
combination • Minimum service life 40 years
• Pneumatic control facilitates direct
connection to SWAGELOK system

PKTMF – 120
Fire damper resistant against seismic events,
effects of high pressure and higher airflow velocity

• Min. dimensions • Pneumatic control facilitates direct


200 × 200 × 375 mm; max. connection to SWAGELOK system
dimensions 1 600 × 800 × 375 mm • Plain bearings – maintenance-free
(square cross-section only, round design resistant to high-level
adapter available) seismic stresses
• certified acc. to EN15650 • Max. airflow 12 m/s
• Tested in accordance with EN 1366-2 • Max. pressure difference 7 500 Pa
• Classified acc. to EN 13501-3+A1 (inner pressure / external pressure
• Fire resistance EIS 120 – static pressure on closed damper
blade)
• External casing leakage class C,
Internal leakage class 2 acc. to EN 1751 • Seismic resistance defined as per
RRS (EDB, APC) applicable to the
• Corrosion resistant acc. to EN 15650
site – tested to peak acceleration
• Cycling test in class C 10000 acc. to above 12 G
EN 15650
• Minimum service life 40 years
• Damper actuating mechanical,
electrical, pneumatical, or
combination
28

PKTMJ – 90/120
Special Applications

Fire damper resistant against seismic events,


effects of high pressure and higher airflow velocity

• Min. dimensions • Pneumatic control facilitates direct


200 × 200 × 375 mm; max. connection to SWAGELOK system
dimensions 1 600 × 1 000 × 375 mm, • Plain bearings – maintenancefree
round ø 180 – 1 000 mm design resistant to high-level
• certified acc. to EN15650 seismic stresses
• Tested in accordance with EN 1366-2 • Max. airflow 15 m/s
• Classified acc. to EN 13501-3+A1 • Max. pressure difference 2 500 Pa
• Fire resistance up to EIS 120 (inner pressure / external pressure
– dynamic pressure)
• External casing leakage class C,
Internal leakage class 2 acc. to • Seismic resistance defined as per
EN 1751 RRS (EDB, APC) applicable to the
site – tested to peak acceleration
• Corrosion resistant acc. to EN 15650
above 5 G
• Cycling test in class C 10000 acc. to
• Minimum service life 40 years
EN 15650
• Suitable for explosion-risk
• Damper actuating mechanical,
environments, Zone 1 and Zone2
electrical, pneumatical, or
combination

NKTMJ
Non-Return/Back draft Damper resistant against seismic
events, effects of high-pressure and to higher airflow velocity

• Min. dimensions 200 × 200 × 210; • Pressure difference up to 7 500 Pa


max. dimensions (internal vs. external pressure)
2 000 × 2 000 × 210 mm (square • Carbon steel painted, galvanized,
cross-section only, round adapter or stainless steel – casings made of
available) 3 mm sheets, tight seam welds
• Only mechanical variant • Radioactive aerosol impact allowed
• Plain bearings, maintenance-free – decontaminable
design • Seismic resistance defined as per
• External casing leakage class C, RRS (EDB, APC) applicable to the
Internal leakage class 3 acc. to site – tested to peak acceleration
EN 1751 above 10 G
• Max. airflow 25 m/s • Min. service life 40 years,
• Variant with, or without maintenance interval 10 000 hours
counterweight
• Mechanism installed externally of
the damper axis and airflow direc-
tion
29

RKTMJ

Special Applications
Multi-leaf regulation damper resistant against seismic
events, effects of high-pressure and to higher airflow
velocity. Usable as insulating damper, tight insulating
damper, low overpressure damper

• Min. dimensions 250 × 250 × 210; • Actuation mechanism installed


max. dimensions externally of the damper axis and
2 000 × 2 000 × 210 mm (square airflow direction
cross-section only, round adapter • Pressure difference up to 7500 Pa
available) (internal vs. external pressure)
• Damper actuating mechanical, • Carbon steel painted, galvanized,
electrical, pneumatical, or or stainless steel – casings made of
combination – possible usage of 3 mm sheets, tight seam welds
additional limit switches
• Radioactive aerosol impact allowed
• Plain bearings, maintenance-free – decontaminable
design
• Seismic resistance defined as per
• External casing leakage class C, RRS (EDB, APC) applicable to the
Internal leakage class 3,4 acc. to site – tested to peak acceleration
EN 1751 above 10 G
• Max. airflow 25 m/s • Min. service life 40 years,
• Contra-rotating aerodynamic blades maintenance interval 10 000 hours

TVMJ
Damping pad

Components to avoid tranfer of noise and vibrations in the ducting systems,


compensate the length , or another changes caused by temperature oscilation
as same as by the next parameters of transported medium, or inpacts of sur-
rounding environment. Usable for compensation of thermal dilatations, errec-
tion work imprecisions and unexpected loads acting to the flanges of compo-
nents solidly connected with dividing constructions. Usable for high-pressures
and high temperatures, seismic resistant above peak accelerations of 30 G.

• Min. dimensions 100 × 100 up to • Material of flanges stainless steel,


2500 × 2500 mm with variable length carbon steel painted, or galvanized
• Length (installation) 60 – 600 mm, steel
longer on order • Material of fabric on basis of PTFE,
• External leakage rate class C, or D Silicone, Silicone-Glass fiber, PVC,
acc. to EN 1751 or combinations in layers
• Usable up to pressure, • Suitable acc. VDI 6022 and
or underpressure 7 kPa DIN 4102 B1/B2
• Flat, or profiled flanges with • Fabrics with Fire Resistance
variable drilling patern up to 500 °C
• Variable height of flanges • Decontaminable surface
30

PKTMC-180
Special Applications

Pressure-proof fire damper

• Dimensions min. ø 200, max. 800 mm • Fire classification EI 180 ve, ho (i  o) S


(circular design only, extension fitting
• Can be installed inside rigid wall,
to square duct possible)
ceiling, onto solid walls, ceilings with
• Stainless Steel - Body Thickness additional insulation and duct instal-
3 – 6 mm, welded construction with lation with insulation by stone wool
passivation
• Pressure tightness class "D" according
• Possible use as a fire damper, a pres- to EN 12266-1 (leakage max. 6 l / min
sure valve with fire resistance, a tight at 1.1 bar)
– pressure resistant valve, a control
• Operable at temperatures up to
damper, a heat and smoke extraction
220 °C (flap leaf is still able to
damper – single, or a combination of
open/close)
• Electric actuator (AUMA, Bernard
• Safe cycles without loss of leakage /
Controls, ROTORK) or pneumatic
fire resistance of at least 20,000
actuator (STASTO-VALBIA), use of limit
switches (Petercem, Telemechanique, • Usable in a magnetic field of up to
Honeywell) 126 mT
• Max. air velocity 35 m/s • Radiation resistance up to 3.35 MGy
• Pressure difference max. 23 kPa • Suitable for explosion hazardous
(inside/outside of duct – dynamic areas Ex II class 3 / 3G.c IIB + H2 TX
pressure when the damper safely • Radioactive aerosol infestation is
opens/ closes) allowed, it is de-contaminable item
• Turbulent flow inside the duct in front • Lifetime of 40 years
of the damper is possible • Low Voltage and Electromagnetic
• Seismic resistance – tested for peak Compatibility Certificates available
accelerations higher than 30 G • IP protection of actuators / pneu-ac-
• Tested according to EN 1366-2, tuators / limit switches is 65
Classified according to EN 13501-3,
CE certified according to EN 15650
31

MANDÍK type M and P (TPM 088/12)

Special Applications
Air-handling unit – seismic

• Airflow volume from 800 to • Indoor and Outdoor variant


100 000 m3/h available
• Instrumentation and Control based • Compliance with the requirements
on Siemens and CAREL governing given by VDI 6022 and
systems platforms EN13053+A1 for sanitary and clean
• Comfort operation control by means environments
of the Siemens Climatix controller • Seismic resistant design
• Unit casing in accordance with
requirements of EN 1886
MANDÍK, a. s.
Dobříšská 550
267 24 Hostomice
Czech Republic
Tel.: +420 311 706 706
Fax: +420 311 584 382
E-mail: [email protected]
www.mandik.cz