0% found this document useful (0 votes)
23 views2 pages

6SL3210-1PE31-8UL0 Datasheet en

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views2 pages

6SL3210-1PE31-8UL0 Datasheet en

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Data sheet for SINAMICS Power module PM240-2

Article No. : 6SL3210-1PE31-8UL0

Client order no. : Item no. : Figure similar


Order no. : Consignment no. :
Offer no. : Project :
Remarks :

Rated data Ambient conditions


Input Cooling Internal air cooling

Number of phases 3 AC Cooling air requirement 0.153 m³/s (5.403 ft³/s)

Line voltage 380 ... 480 V ±10 % Installation altitude 1,000 m (3,280.84 ft)

Line frequency 47 ... 63 Hz Ambient temperature

Rated current (LO) 172.00 A Operation LO -20 ... 40 °C (-4 ... 104 °F)

Rated current (HO) 154.00 A Operation HO -20 ... 50 °C (-4 ... 122 °F)

Output Transport -40 ... 70 °C (-40 ... 158 °F)

Number of phases 3 AC Storage -40 ... 70 °C (-40 ... 158 °F)

Rated voltage 400V IEC 480V NEC 1) Relative humidity

Rated power (LO) 90.00 kW 125.00 hp Max. operation 95 % RH, condensation not permitted

Rated power (HO) 75.00 kW 100.00 hp


Connections
Rated current (LO) 178.00 A
Line side
Rated current (HO) 145.00 A
Version M10 bolt
Max. output current 290.00 A
35.00 ... 120.00 mm²
Conductor cross-section
Pulse frequency 2 kHz (AWG 2 ... AWG -3)

Output frequency for vector control 0 ... 200 Hz Motor end

Output frequency for V/f control 0 ... 550 Hz Version M10 bolt

Overload capability 35.00 ... 120.00 mm²


Conductor cross-section
(AWG 2 ... AWG -3)
Low Overload (LO)
DC link (for braking resistor)
1.1 x rated output current (i.e. 110 % overload) for 57 s with a cycle time of
300 s 1.5 × rated output current (i.e. 150 % overload) for 3 s with a cycle time Version Screw-type terminals
of 300 s
25.00 ... 70.00 mm²
Conductor cross-section
High Overload (HO) (AWG 4 ... AWG -1)

1.5 × output current rating (i.e., 150 % overload) for 57 s with a cycle time of Cable length 10 m (32.81 ft)
300 s 2 × output current rating (i.e., 200 % overload) for 3 s with a cycle time
of 300 s PE connection M10 screw studs

Max. motor cable length


General tech. specifications
Shielded 300 m (984.25 ft)
Power factor λ 0.95
Unshielded 450 m (1,476.38 ft)
Offset factor cos φ 0.99

Efficiency η 0.98 Mechanical data


Sound pressure level (1m) 68 dB Degree of protection IP20 / UL open type

Power loss 2.31 kW Frame size FSF

Filter class (integrated) - Net weight 57.00 kg (125.66 lb)

Dimensions

Width 305 mm (12.01 in)

Height 708 mm (27.87 in)

Depth 357 mm (14.06 in)

Standards
Compliance with standards UL, cUL, CE, C-Tick (RCM), SEMI F47

CE marking Low-voltage directive 2006/95/EC

Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 1 of 2 Generated Thu Sep 21 14:10:17 CET 2023
Data sheet for SINAMICS Power module PM240-2
Article No. : 6SL3210-1PE31-8UL0

Converter losses to IEC61800-9-2*


Efficiency class IE2

Comparison with the reference


50.60 %
converter (90% / 100%)

I 1,760.0 W (1.40 %) 2,060.0 W (1.70 %) 2,560.0 W (2.10 %)


100%

967.0 W (0.80 %) 1,070.0 W (0.90 %) 1,240.0 W (1.00 %)


50%

703.0 W (0.60 %) 748.0 W (0.60 %)


25%

50% 90% f
The percentage values show the losses in relation to the rated apparent power of
the converter.

The diagram shows the losses for the points (as per standard IEC61800-9-2) of
the relative torque generating current (I) over the relative motor stator frequency
(f). The values are valid for the basic version of the converter without
options/components.

*converted values

1) The output current and HP ratings are valid for the voltage range 440V-480V

Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 2 of 2 Generated Thu Sep 21 14:10:17 CET 2023