0% found this document useful (0 votes)
62 views10 pages

Precon Report - Senada - BLK A Rooftop 041223

The document provides details of a site survey conducted for installing network devices at a site named SENADA - BLK A ROOFTOP. It lists customer site details, infrastructure requirements, site access and power supply details. RF study was also conducted to check site connectivity.

Uploaded by

krekokei
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views10 pages

Precon Report - Senada - BLK A Rooftop 041223

The document provides details of a site survey conducted for installing network devices at a site named SENADA - BLK A ROOFTOP. It lists customer site details, infrastructure requirements, site access and power supply details. RF study was also conducted to check site connectivity.

Uploaded by

krekokei
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

SITE SURVEY REPORT

This document lists the following:


Customer Site details
Infrastructure requirement for WAN/NAN Device installation
• Site Access details
Site Power Supply (AC/DC) source availability
RF Study for Site Connectivity

Project Name AMI PHASE 2


BAC Name KL BARAT
Primary Cluster KL BARAT
Site Name SENADA - BLK A ROOFTOP
Site ID RPTR_WKLB56_009
1, JALAN KIARA 1, BUKIT KIARA, 60000 KUALA LUMPUR, WILAYAH
Site Address
PERSEKUTUAN KUALA LUMPUR
Parent Site N/A
Contractor Name FGV PRODATA SYSTEMS SDN BHD
Date of Survey 29 MAY 2023
SITE SURVEY REPORT SIGNOFF
CONTRACTOR TNB-ICT PROJECT ENGINEER

Name

Designation

Contact
Number

Date 5/6/2023

Signature

1|P age
SITE SURVEY REPORT
1. Site Information:
1.1 Site Name SENADA - BLK A ROOFTOP
PMU PPU SSU PE
1.2 Site Type (check one)
LV Pole HighRise

GW EB Collector Repeater
1.3 Device Type (check one)
Others Pleasespecify typeofdevice

1.4 Site Geo Coordinates Latitude 3.138519


(in decimal degrees) Longitude 101.648987

1.5 Building Height Meters

1.6 Site Photo SURROUNDINGS

2|P age
SITE SURVEY REPORT
2. Site Mounting Details:
Rooftop NewPole Wall
2.1 Device Mounting location(check one)
LV Pole

2.2 Proposed Rooftop/ Wall Height 1.2 Meters

2.3 Proposed Rooftop Area 1 Sq.Meter/Sq.Feet.

2.4 Proposed Pole / Mast Height 1.2_Meters

2.5 Distance of Power Line from Pole location N/A Meters


Note: There must be a minimum clearance of 40 meters from the identified pole location to path of power line at
PMU sites
2.6 Site Access Details Width 4 Meters Height N/A Meters

2.7 Sky Lift Access Available Yes No

2.8 Proposed Pole Mounting Location

Pole not available for this site.

2.9 Other Information

Nearest identical next to the Repeater Location.

3|P age
SITE SURVEY REPORT
3. Site Power Supply & POP Details:
3.1 Site Power Supply Source Type (check one) AC DC

3.2 If Power Source Type AC 230V

3.2.1 Location of PSU (check one) Indoor Outdoor

3.2.2 Distance from Repeater to Power Source 30 Meters

3.2.3 Distance from PSU to Device N/A Meters

3.3 If Power Source Type DC DC48V Rectifier system

3.3.1 DC Supply (check one) 48VDC 24VDC

3.3.2 DC Supply Power _N/A Watts

3.4 POE Enclosure N/A

3.44.1 Location of POE Enclosure (check one) Indoor Outdoor

3.4.2 Distance from POE Enclosure to Power Source N/A meters

3.4.3 Distance from POE Enclosure to Pole foundation N/A meters

3.5 Battery N/A

3.5.1 Battery Backup Available (check one) Yes No

3.6 POP Details for Gateway This section is applicable only for Gateway
3.6.1 Type of POP Location Fiber based MPLS Network Fiber based SDH Network

3.6.2 MPLS/SDH Port Type RJ45 SFP

3.6.3 MPLS/SDH Port Number


N/A
(If available)
3.6.4 MPLS/SDH Device Make N/A Model N/A
3.6.5 Distance from MPLS/SDH port to
N/A Meters
POE LAN port
3.7 Remarks (if any)

4|P age
SITE SURVEY REPORT
3.8 Proposed repeater location, cable routing and power termination location.

PROPOSED LMR PROPOSED HACK


CABLE LAY IN WALL
PROPOSED REPEATER
AT ROOFTOP BLOCK A 25MM WHITE
PVC CONDUIT

PROPOSED HACK
WALL

PROPOSED LMR
PROPOSED 2 X 4MMSQ PROPOSED 2 X 4MMSQ CABLE LAY IN
PVC CABLE & 6MMSQ PVC CABLE & 6MMSQ 25MM WHITE
PROPOSED
GROUNDING CABLE LAY GROUNDING CABLE LAY PVC CONDUIT
NAN ANTENNA
IN 25MM WHTE PVC IN 25MM WHTE PVC
CONDUIT CONDUIT

PROPOSED 2 X 4MMSQ PVC


CABLE & 6MMSQ GROUNDING
CABLE LAY IN 25MM WHITE
PVC CONDUIT

PROPOSED 2 X 4MMSQ PVC


CABLE & 6MMSQ GROUNDING
CABLE LAY IN 25MM WHITE
PVC CONDUIT

PROPOSED LMR
CABLE LAY IN PROPOSED HACK
25MM WHITE WALL
PVC CONDUIT PROPOSED LMR
CABLE LAY IN
25MM WHITE
PVC CONDUIT

5|P age
SITE SURVEY REPORT

PROPOSED 2 X 4MMSQ PVC CABLE


& 6MMSQ GROUNDING CABLE LAY PROPOSED 2 X
IN 25MM WHITE PVC CONDUIT 4MMSQ PVC CABLE &
6MMSQ GROUNDING
CABLE LAY IN 25MM
ORANGE PVC
CONDUIT

PROPOSED HACK
WALL

PROPOSED HACK
WALL
PROPOSED LMR
CABLE LAY IN
25MM WHITE PVC
CONDUIT PROPOSED LMR
CABLE LAY IN 25MM
ORANGE PVC
CONDUIT

PROPOSED LMR CABLE LAY


IN 25MM ORANGE PVC
CONDUIT

PROPOSED 2 X
4MMSQ PVC CABLE &
6MMSQ GROUNDING
CABLE LAY IN 25MM
ORANGE PVC
CONDUIT RUN ON
EXISTING CABLE TRAY

PROPOSED LMR CABLE LAY PROPOSED 2 X


IN 25MM ORANGE PVC 4MMSQ PVC CABLE &
CONDUIT RUN ON 6MMSQ GROUNDING
EXISTING CABLE TRAY CABLE LAY IN 25MM
ORANGE PVC
CONDUIT RUN ON
EXISTING CABLE TRAY

6|P age
SITE SURVEY REPORT
PROPOSED POWER PROPOSED DB
TERMINATION BOX INSIDE RISER
LOCATION ROOM BLOCK A
LEVEL 20
PROPOSED 2 X 10MMSQ PVC
CABLE & 6MMSQ GROUNDING
CABLE LAY IN 25MM ORANGE
PVC CONDUIT
PROPOSED 2 X
10MMSQ PVC
PROPOSED METER CABLE & 6MMSQ
PANEL INSIDE RISER GROUNDING
ROOM BLOCK A CABLE LAY IN
LEVEL 20 25MM ORANGE
PVC CONDUIT

PROPOSED 2 X 4MMSQ PVC


CABLE & 6MMSQ
GROUNDING CABLE LAY IN PROPOSED 2 X
25MM ORANGE PVC 4MMSQ PVC CABLE &
CONDUIT 6MMSQ GROUNDING
CABLE LAY IN 25MM
ORANGE PVC
PROPOSED LMR CABLE LAY CONDUIT
IN 25MM ORANGE PVC
CONDUIT TO LEVEL 18

PROPOSED LMR CABLE LAY


IN 25MM ORANGE PVC
CONDUIT

PROPOSED NAN ANTENNA


INSIDE RISER ROOM
BLOCK A LEVEL 18

7|P age
SITE SURVEY REPORT
4. Drawing Bracket Repeater and Nan Antenna:
Height: meters

4.1 Drawing Bracket Repeater at Block A (Rooftop):

DRAWING BRACKET REPEATER AT ROOFTOP BLOCK A

8|P age
SITE SURVEY REPORT
4.2 Drawing Bracket Nan Antenna inside Riser Room Block A Level 20:

DRAWING BRACKET NAN ANTENNA INSIDE RISER ROOM BLOCK A LEVEL 18

9|P age
SITE SURVEY REPORT
5. NAN Details
5.1 Meter Location RESIDENCE HOUSE

5.1.1 Meter Location Type Urban Semi Urban Rural

5.1.2 Neighborhood Building type Apartment Shop house Residential

5.1.3 Distance to nearest Meter 30 Meters

5.2 Backhaul Details N/A


5.2.1 Backhaul Type for N/A
Secure Mesh
Collector N/A
5.2.2 If 3G/4G, Signal Strength
5.3 Meter Panel Drawing

~ END ~

10 | P a g e

You might also like