A1 TC 1+
A2 TC 1-
E888 Outputs
A3
TC 2+ PMW 1 B1 Outputs can be used as hi-side or
A4 B2 low-side drive
TC 2- PMW 2
A14 B3
TC 3+ PMW 3 Low-side example
K type A5 B4 Relay coil
TC 3- PMW 4 +12Volt
Thermocouple A12 B5
TC 4+ PMW 5
Sensors A13 B6 Hi-side example
TC 4- PMW 6 Relay coil
A18 B7
TC 5+ PMW 7 Ground
A19 B13
TC 5- PMW 8
A20
TC 6+
A21
TC 6-
A26 A17, B8, B9 From Fused protected
TC 7+ 12V
A27 +12Volt supply
TC 7-
A28
TC 8+ A10, A11, B15, B16
A29 GND
TC 8-
Cold Junction compensation A6 CJC1
temperature sensors.
Use MoTeC part no 55001 RS 232 Tx B17 Serial Communication
A7 CJC2 RS 232 Rx B26 Reserved for future
0V Comms B14 expansion
A15 0V
Aux Sensor A34 +5V
Power & 0V B20 +5V CAN LO B24 Wire to MoTeC CAN Bus
A16 CAN HI B23 Refer to drawing A12
+8V
B22 +8V
A22 A9
AV 1 CAN LO-2 Do not use for ECU or ADL
A23 A8
AV 2 CAN HI-2 Communication. Can 2 reserved
ANALOG A24
AV 3 for future expansion
VOLT INPUTS A25 AV 4
A30 AV 5
A31 AV 6
A32 AV 7 Note:
A33 AV 8 Refer to manual for Current
capacity for PWM pins.
B21 0V
B11 All GND and +12V pins should be
Dig 1 used when switching high load
B10
Dig 2 currents.
B19
Use Digital 1 to 4 for Dig 3
B18
speed inputs Dig 4
B12
Dig 5
B25 Dig 6
Looking into Connector on E888A
A1 A9 B1 B7
A10 A17 B8 B13
A18 A25 B14 B19
A26 A34 B20 B26
E888 Wiring
MoTeC
Title Sheet No Drawing No
Date 24/06/2005 Drawn ST App JJ Products ADL / ECU 1 of 2 A17