DC-LISN for Photovoltaic Testing

The document describes a new dual-line LISN for measuring disturbances on DC power ports of grid connected power conditioners from 150 kHz to 30 MHz. The DC-LISN-M2-100 provides enhanced performance with 150 Ω common-mode and 100 Ω differential-mode impedance. It can operate as a V, Y, or Delta shaped LISN and measures in the frequency range of 1 kHz to 150 kHz.

Uploaded by

Tieu Hoai Van
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views7 pages

DC-LISN for Photovoltaic Testing

The document describes a new dual-line LISN for measuring disturbances on DC power ports of grid connected power conditioners from 150 kHz to 30 MHz. The DC-LISN-M2-100 provides enhanced performance with 150 Ω common-mode and 100 Ω differential-mode impedance. It can operate as a V, Y, or Delta shaped LISN and measures in the frequency range of 1 kHz to 150 kHz.

Uploaded by

Tieu Hoai Van
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

DC-LISN-M2-100

DUAL-LINE-V-Y-Δ-LISN FOR GCPC

Teseq introduces a new Line Impedance Stabilization Network (LISN) for conducted emissions testing of
Grid Connected Power Conditioners (GCPC). The DC-LISN-M2-100 is designed for measuring disturbances
on DC power ports in the frequency range from 150 kHz to 30 MHz. Research results have shown that
a typical artificial mains V-network as described in CISPR 16-1-2 can not be used for the assessment of
unsymmetrical disturbances of a photovoltaic inverter’s DC port. CDNs based on IEC / EN 61000-4-6 are
typical not specified for high common-mode currents and differential-mode disturbances. Additionally,
they are undefined below 150 kHz.

The DC-LISN-M2-100 provides enhanced LISN performance with a common-mode impedance of 150 Ω
DC-LISN-M2-100 and a differential-mode impedance of 100 Ω. Depending on the switch position, the LISN works as V, Y
or Delta shape LISN. Further, the DC-LISN offers defined termination impedance in the frequency range
1 kHz to 150 kHz.
Frequency range 150 kHz to 30 MHz
150 Ω DC-LISN for photovoltaic The DC-LISN-M2-100 conforms to the latest requirements of the international standard working group
inverters MT GCPC: GRID CONNECTED POWER CONDITIONERS.
Switch for selecting the LISN type:
V, Y, Delta
150 A for 30 min Technical specifications

Nominal voltage: 1000 VDC (between the lines)


Max. operating voltage: 1500 V (VDC + VAC ripple voltage)
Max. CM voltage ≤100 Hz: 750 VDC, 500 VAC (line to ground)
Test voltage: 2 kV, DC, 2 sec (line to ground)
Voltage drop: 3 V @ 100 A
CM decoupling capacitance: <100 nF
Nominal current (CM + DM): 100 A with fans on
Max. operating current (CM + DM): 150 A with fans on, 30 min
Mains sockets EUT / AE: butterfly screw for binding posts with flat clamp
RF socket: N, 50 Ω

Frequency range: 150 kHz to 30 MHz 1 kHz to 150 kHz


Common-mode impedance: 150 Ω ±20 Ω ≥ 10 Ω (AE open)
Phase angle: 0° ± 40° not specified
Differential-mode impedance: 100 Ω ±20 Ω ≥ 10 Ω (AE open)
Phase angle: 0° ± 40° not specified
Voltage division factor: 20 dB ± 2 dB > 68 dB to > 18 dB
Insertion Loss (EUT – AE, CM): > 20 dB decreasing with 40 dB / dec.
Insertion Loss (EUT – AE, DM): > 20 dB decreasing with 40 dB / dec.
LCL: > 26 dB > 26 dB (10 kHz to 150 kHz)
Discharge resistors: >1.5 MΩ

Notes: All symmetrical parameters are only valid for a symmetrical impedance of 100 Ω.
CM = Common-mode, DM = Differential-mode
DC-LISN-M2-100
DUAL-LINE-V-Y-Δ-LISN FOR GCPC

Front panel

Bar for plane earth EUT port Switch for selecting Receiver port
connection (connected to DC the LISN type: V shape
port of PV inverter) +, V shape -, Y shape
(CM) and Δ shape (DM)

Back panel

Fans power input, Fans EUT power input (PV Protective earth con-
selectable for 230 V or generator / simula- nection
115 V range tor)
DC-LISN-M2-100
DUAL-LINE-V-Y-Δ-LISN FOR GCPC

Typical common-mode impedance for +, -, CM and DM


AE open, AE short, Limit AE open < 150 kHz Limit
DC-LISN-M2-100 - Common Mode Impedance - Magnitude (EUT)

300
300

250
Common-mode impedance in Ω

250

200
200
|Zce| / ohms

150
150

100
100

5050

00
0.01
0,01
0.1
0,10
1
1,00
10
10,00
100
100,00

Frequency / MHz
Frequency
+/-, AE-open in MHz CM, AE-open DM, AE-open +/-, AE-short
CM, AE-short DM, AE-short Limit AE-open <150kHz Limit

Typical common-mode phase for +, -, CM and DM


AE open, AE short, Limit
DC-LISN-M2-100 - Common Mode Impedance - Phase Angle (EUT)

100
100

8080
6060
Common-mode phase in deg

4040
2020
Phase / deg

0 0

-20
-20

-40
-40

-60
-60

-80
-80

-100
-100

0.01
0,01
0.1
0,10
1
1,00
10
10,00
100
100,00

Frequency / MHz
Frequency in MHz
+/-, AE-open CM, AE-open DM, AE-open +/-, AE short CM, AE-short DM, AE-short Limit
DC-LISN-M2-100
DUAL-LINE-V-Y-Δ-LISN FOR GCPC

Typical differential-mode impedance for +, -, CM and DM


AE open, AE short, Limit AE open < 150 kHz Limit
DC-LISN-M2-100 - Differential Mode Impedance - Magnitude (EUT)

300
300
Differential-mode impedance in Ω

250
250

200
200
|Z| / ohms

150
150

100
100

5050

00
0.01
0,01
0.1
0,10
1
1,00
10
10,00
100
100,00

Frequency / MHz
Frequency
+/-, AE-open in MHz CM, AE-open DM, AE-open +/-, AE-short
CM, AE-short DM, AE-short Limit AE-open <150kHz Limit

Typical differential-mode phase for +, -, CM and DM


AE open, AE short, Limit
DC-LISN-M2-100 - Differential Mode Impedance - Phase Angle (EUT)

100
100

8080
Differential-mode phase in deg

6060
4040
2020
Phase / deg

0 0

-20
-20

-40
-40

-60
-60

-80
-80

-100
-100

0.01
0,010
0.1
0,100
1
1,000
10
10,000
100
100,000

Frequency / MHz
Frequency in MHz
+/-, AE-open CM, AE-open DM, AE-open +/-, AE-short CM, AE-short DM, AE-short Limit
DC-LISN-M2-100
DUAL-LINE-V-Y-Δ-LISN FOR GCPC

Typical voltage division factor (EUT - RF port, dotted line for AE shorted)
+ Port, - Port, CM, DM, Limit
DC- LISN-M2-100 - Voltage Division Factor (EUT - RF Port)

00
-10
-10

-20
-20
Voltage division factor in dB

-30
-30

-40
-40
VDF / dB

-50
-50

-60
-60

-70
-70

-80
-80

-90
-90

-100
-100
0.01
0,01 0.1
0,10 1
1,00 10
10,00 100
100,00

Frequency / MHz
Frequency
+ Port, AE-open in MHz
- Port, AE-open CM, AE-open DM, AE-open + Port, AE-short
- Port, AE-short CM, AE-short DM, AE-short Limit

Typical insertion loss (common-mode, EUT - AE)


+ Port, - Port, CM, DM, Limit
DC-LISN-M2-100 - Insertion Loss (Common Mode, EUT - AE, 50R)

0 0

-10-10

-20
-20

-30
-30
Insertion loss CM in dB
a / dB

-40
-40

-50
-50

-60
-60

-70-70

-80
-80
0.01
0,01 0.1
0,10 1
1,00 10
10,00 100
100,00

Frequency / MHz
Frequency in MHz
+/- CM DM Limit
DC-LISN-M2-100
DUAL-LINE-V-Y-Δ-LISN FOR GCPC

Typical insertion loss (differential-mode, EUT - AE, dotted line for additional 1 µF)
+ Port, - Port, CM, DM, Limit
DC-LISN-M2-100 - Insertion Loss (Differential Mode, EUT - AE, 100R)

0 0

-10
-10

-20
-20

-30
-30
Insertion loss DM in dB
a / dB

-40
-40

-50
-50

-60
-60

-70
-70

-80
-80
0.01
0,01 0.1
0,10 1
1,00 10
10,00 100
100,00
Frequency / MHz
Frequency in MHz
+/- CM DM Limit +/- 1uF CM 1uF DM 1uF

Typical longitudinal conversion loss (EUT)


+ Port, - Port, CM, DM, Limit
DC-LISN-M2-100 - Longitudinal Conversion Loss (EUT)

00
-10
-10

-20
-20

-30
-30

-40
-40

-50
-50
LCL / dB

-60
-60

-70
-70
LCL in dB

-80
-80

-90
-90

-100
-100

0.01
0,01
0.1
0,10
1
1,00
10
10,00
100
100,00
Frequency / MHz
Frequency in MHz
+ Port - Port CM DM Limit
DC-LISN-M2-100
DUAL-LINE-V-Y-Δ-LISN FOR GCPC

Measuring setup

CISPR 16-1-1 RECEIVER


Local
CH 1 CH 2 MEAS FOR SCL RF
ON/OFF

STO RCL DIA DIS TRA Help

FRQ LVL MOD

STO RCL MOD 2nd

StSize StSize StSize


Run Step
Stop Hold Step Step
1 2 3

MHz
FRQ LVL MOD 7 8 9 dBµV
Tuning

kHz
STO RCL MOD 4 5 6 dBm

Hz
FRQ LVL MOD 1 2 3 V

Back STO RCL MOD 0 . Enter

RF IN 50 Ω
USB

USB Power

DC-LISN-M2-100 DUAL-LINE-V-Y- -LISN for GCPC

RF Output

+
-
CM
DM

to PV generator, Equipment
PV generator simulator + -
under test
EUT EUT

EUT
Unit must be connected to PE before use !

to EUT power Earthing Reference ground plane DC power Insulating


input of DC-LISN connections port (input)
of the PV inverter

Mechanical specifications

Size (L x H x D): 484 mm x 237 mm x 564 mm


(handles and unit supports can be removed for 19” / 6 HU format)
Weight: approx. 27 kg

Model No. and options

Part number Description


Teseq GmbH 243885 DC-LISN-M2-100
Landsberger Str. 255 · 12623 Berlin · Germany
T + 49 30 56 59 88 35 F + 49 30 56 59 88 34
Dual-Line-V-Y-Δ-LISN for GCPC, 100 A
[email protected] www.teseq.com 243985 CAS DC-LISN-100
Calibration kit for DC-LISN-M2-100
© Feb. 2014 Teseq ® 97-243710 DC-LISN-TC
Specifications subject to change without notice.
Traceable calibration (ISO17025), order only with DC-LISN
Teseq ® is an ISO-registered company. Its products
are designed and manufactured under the strict
quality and environmental requirements of the ISO
9001. This document has been carefully checked.
However, Teseq ® does not assume any liability for
errors or inaccuracies.

82-243885 E02 Feb. 2014