Best Practice

Guide

Single-axis hinges
to BS EN 1935

www.dhfonline.org.uk
Best Practice
Guide

01 | dhf Best Practice


dhf Best Practice Guide: Windows and Doors -
Single-axis hinges to BS EN 1935

dhf Best Practice Guides


This publication is one in a series of guides addressing the major issues that should be considered when specifying, ordering or using the products
it describes. It aims to provide the reader with a concise document which includes a summary of relevant sections from the new European
product standard. The reader will then be in a position to seek further specialist advice where necessary and recognise GENUINE conformity to
the new standards. Unless otherwise stated, references in this document to BS EN 1935 refer to BS EN 1935:2002. Information in this guide is
correct at time of publication and intended for guidance only. Information may since have changed and readers should consult the appropriate
standards and authorities to confirm its veracity.

BS EN 1935 Single-axis hinges dhf recommends the use of graphic icons to enhance clarity of
information and has devised a system to facilitate assimilation of
This standard provides details on product types, classification by use, the various product classifications. Each feature within the product
test cycles, door mass, corrosion resistance, as well as definitions, classification is represented by an icon comprising four elements;
product performance requirements, test apparatus, test methods Symbol, Grade/Type, Range/Options and Box:-
and marking of products. In addition, the published standard includes
annexes with details for special applications.

Extracts from BS EN 1935 are reproduced with the permission of the


British Standards Institution under licence number 2003/SK0014. BSI
publications can be obtained from: The icon above is for a product which meets Grade 2 in the Category
BSI Customer Services, 389 Chiswick of Use classification, where EN 1935 stipulates a range of four possible
High Road, London W4 4AL Tel +44 (0)20 8996 9001 grades from 1 to 4.
Email: [email protected].
Digit 1
NOTE: This standard has replaced BS 7352:1990: Specification for
Category of use
strength and durability performance of metal hinges for side hanging
applications and dimensional requirements for template drilled hinges. Four categories of use are identified:
• grade 1: light duty

Scope •

grade 2: medium duty
grade 3: heavy duty
This European standard specifies requirements for single-axis hinges for
• grade 4: severe duty
windows and doors opening in one direction only, whose rotation axis
is no more than 30mm from the face of the sash or door. It covers both
fixed pin and lift-off hinges, and contains additional requirements for Digit 2
hinges intended for use on fire doors. Durability
Three grades are identified for single-axis hinges manufactured to this
European standard:
Classification • grade 3: 10 000 test cycles, for light duty hinges on windows only

BS EN 1935 classifies door furniture by using an 8 digit coding system. • grade 4: 25 000 test cycles, for light duty hinges on windows and doors
A similar classification applies to all building hardware product standards
so that complementary items of hardware can be specified to, for
instance, a common level of corrosion resistance, category of use, etc.
Each digit refers to a particular feature of the product measured against
the standard’s performance requirements.

dhf Best Practice | 02


Best Practice
Guide

• grade 7: 200 000 test cycles, for medium. heavy and severe duty Digit 7
hinges on doors only. Security
Two grades of security are identified for single-axis hinges:

Digit 3 • grade 0: not suitable for use on burglar-resistant door


Test door mass assemblies

Eight door mass grades related to single-axis hinges are identified in this • grade 1: suitable for applications requiring a degree of security.
European standard as shown in Table 1 below. Annex C of this European standard details the hinge grade to use
for the level of security required.

Table 1
Digit 8
Test door mass grade Door mass
Hinge grade
0 10 kg
Fourteen grades are identified in this European standard and
1 20 kg
are detailed in Table 2 below. The full classification is shown in
2 40 kg the standard.

3 60 kg
4 80 kg Table 2

5 100 kg Hinge Usage Test cycles Door mass


6 120 kg grade
7 160 kg 1 Window 10 000 10 kg
2 Window 10 000 20 kg
3 Window/Door 25 000 20 kg
Digit 4
4 Door 200 000 20 kg
Suitability for fire/smoke door use
Two grades of suitability are identified for single-axis hinges: 5 Window 10 000 40 kg

• grade 0: not suitable for fire/smoke resistant door assemblies 6 Window/Door 25 000 40 kg
• grade 1: suitable for fire/smoke resistant door assemblies 7 Door 200 000 40 kg
subject to satisfactory assessment of the contribution of the
8 Window 10 000 60 kg
single-axis hinge to the fire resistance of the specified fire/
smoke door assemblies. Such assessment is beyond the scope of 9 Window/Door 25 000 60 kg
this European standard (see EN 1634-1). 10 Door 200 000 60 kg
11 Door 200 000 80 kg
Digit 5 12 Door 200 000 100 kg
Safety
13 Door 200 000 120 kg
Single-axis hinges are required to satisfy the essential requirements of
14 Door 200 000 160 kg
safety in use. Therefore, only grade 1 is identified.

Example
Digit 6
Corrosion resistance Example: the following marking denotes a single-axis hinge for use
in medium duty situations, tested to 200 000 cycles, for use on doors
Five grades of corrosion resistance are identified in accordance with with a mass up to 60 kg, with stated fire door suitability, satisfying
EN 1670: the essential requirement of safety in use, high corrosion resistance,
• grade 0: no defined corrosion resistance. suitable for burglar-resistant doors and with a hinge grading of 10.
• grade 1: mild resistance.
• grade 2: moderate resistance.
2 7 3 1 1 4 1 10
• grade 3: high resistance. (1-4) (3/4/7) (1-8) (0/1) (1) (0-4) (0/1) (1-14)

• grade 4: very high resistance.

03 | dhf Best Practice


Marking Quality assurance
Each single-axis hinge manufactured to this European standard must be The internationally recognised standard for quality assurance,
marked with the following: BS EN ISO 9000 provides confidence that the products are being
manufactured to a consistent quality level.
(a) manufacturer’s name or trademark, or other means of identification.
Companies displaying this symbol are registered under the
(b) the hinge grade (eighth digit of classification code).
BSI Registered Firm Scheme.
(d) number of this European standard.

Note: This information can be in coded form


Support service
The correct installation of hinges is essential to ensure that they are

CE Marking
able to operate efficiently within the performance levels described in
this standard. Specialist advice is available from dhf Building Hardware
Single axis hinges intended for use on fire resisting doors and smoke members in support of their products from specification stages through
control doors are covered by a Construction Products Directive mandate supply to effective operation on site.
issued by the European Commission. Consequently, this standard is
regarded as a “harmonised” standard and compliance with it, supported
by suitable evidence, allows the application of the CE mark. Conformity
As fire/smoke door hinges have a critical safety function, application Conformity to the standard must be clearly and unequivocally stated.
of the CE mark will require the involvement of a notified certification Such phrases as “tested to ...”, “designed to conform to ...”, “approved
body to provide verification of the compliance claims. This will involve to ...”, are not sufficient. To avoid misleading or confusing claims it is
initial type-testing of the product to EN 1935, initial inspection of the recommended that one of the following phrases is used when stating
manufacturer’s factory production control and continuing surveillance and conformity:
approval of the factory production control. On satisfactory completion of a) This product has been successfully type-tested for conformity to all of
these tasks, the notified body issues an EC Certificate of Conformity which the requirements of BS EN 1935.
then permits the manufacturer to declare compliance and affix the CE
Test reports and/or certificates are available upon request.
marking to his product.
b) This product has been successfully type-tested for conformity to all of
The standard requires the following additional information to accompany
the requirements of BS EN 1935 including the additional requirements for
the CE marking:-
fire/smoke door use*.
• the identification number of the notified certification body Test reports and/or certificates are available upon request.
• the name or identifying mark of the manufacturer *Add as appropriate.

• the registered address of the manufacturer c) This product has been successfully type-tested for conformity to all of
the requirements of BS EN 1935 including the additional requirements for
• the last two digits of the year in which the marking was applied fire/smoke door use*. Regular audit testing is undertaken.
• the number of the EC certificate of conformity Test reports and/or certificates are available upon request.
*Add as appropriate.
• reference to EN 1935:2002
It is recommended that an ARGE Declaration of Compliance is
• the classification code of the product also completed, as this gives a clear and unambiguous method of
NOTE: Although the notified body has to be involved to verify the demonstrating test evidence and compliance.
manufacturer’s claims, the manufacturer remains responsible for
designing and producing the product, for affixing the CE marking, and for
ensuring that the product meets the requirements of the Directive.

In addition to ensuring that products satisfy the requirements of this


standard, other factors should be taken into consideration when
selecting hinges. These not only include sourcing products from a
reputable manufacturer, but also quality assurance, support services and
unequivocal conformity to the standard as detailed below:

dhf Best Practice | 04


Best Practice
Guide

dhf
dhf was created by a merger between the Association of Building
Guild of Architectural Ironmongers
Hardware Manufacturers (ABHM) and the Door and Shutter Founded in 1961, the GAI represents the majority of Architectural
Manufacturers Association (DSMA), both of which had established Ironmongers in the UK. The GAI serves to further all aspects
excellent reputations in their respective industries, particularly of architectural ironmongery by promoting the interchange
in the area of technical expertise and the development of of information to encourage better products design and high
performance standards in national and international arenas. professional standards of ironmongery scheduling and specification.
GAI has also expanded its offering to include overseas clients, who
dhf has built on these reputations by exploiting the synergies
are increasingly taking advantage of its comprehensive education
that existed between the two associations and combining
programme.
their technical and financial resources to provide a unified,
authoritative voice for the entire industry.
dhf and its members have consistently risen to the challenges
posed by an ever-changing market, creating products which
meet the needs of a changing world and developing performance
standards alongside national and international organisations, such
as BSI and CEN, which enable the industry to select and compare Master Locksmiths Association
products with confidence.
The MLA is the leading trade association for the locksmithing
dhf now represents all the key players in the following sectors:
industry. It is recognised as the authoritative body by the police,
locks and building hardware, doorsets, industrial doors and
government, insurers and other such groups. MLA licenced
shutters, domestic garage doors and automated gates/traffic
companies can provide customers with peace of mind regarding the
barriers.
security of their property. Its members undergo strict vetting and
With the ultimate aim of maintaining and raising quality standards regular inspections.
throughout the industry, all dhf members must meet minimum
standards of competence and customer service. They all operate
within a Code of Conduct governing standards of workmanship,
quality assurance, training, safety, business integrity and CE
marking compliance.

This document has been produced in association with Guild of Architectural Ironmongers (gai) and Master Locksmiths Association (MLA).

05 | dhf Best Practice


DHF Best Practice | 06
Best Practice
Guide

Contact us for more information


Email: [email protected]

Telephone: (0)1827 52337

Address: dhf The Barn, Shuttington Fields Farm, Main Road, Shuttington, Tamworth B79 0HA

© Copyright dhf (Door & Hardware Federation) 2021


No part of this publication may be reproduced in any form without prior permission in writing from dhf. E&OE

dhf 1031/v2/04:21 www.dhfonline.org.uk

Common questions

Powered by AI

The eight-digit coding system in BS EN 1935 helps choose appropriate single-axis hinges by detailing key product features like category of use, durability, test door mass, fire/smoke suitability, safety, corrosion resistance, security, and hinge grade. Each digit corresponds to a different feature, clearly conveying the specifications necessary for particular applications. For example, the first digit classifies the usage intensity (from light to severe), while the second digit specifies the durability in terms of test cycles . This comprehensive classification allows for precise specification and selection based on environmental and usage demands.

Corrosion resistance is crucial in the classification of single-axis hinges to ensure durability and functionality over time, especially in harsh environments. The BS EN 1935 standard identifies five levels of corrosion resistance: grade 0 (no defined resistance), grade 1 (mild resistance), grade 2 (moderate resistance), grade 3 (high resistance), and grade 4 (very high resistance). Ensuring an appropriate level of corrosion resistance is vital to maintain the integrity and performance of the hinges under various environmental conditions.

The ARGE Declaration of Compliance provides a clear and unambiguous method of demonstrating test evidence and compliance for single-axis hinges. It is recommended as it helps avoid misleading claims by clearly stating a product's conformity to the BS EN 1935 requirements. It ensures that buyers and users can trust the performance and quality of the hinges they are purchasing .

The BS EN 1935 standard ensures the safety of single-axis hinges by mandating them to satisfy the essential requirements of safety in use. This is represented by a single grade, grade 1, which all hinges must meet to ensure safe operation . This focus on safety reflects the need for hinges to perform reliably under expected conditions without posing risks to users.

The BS EN 1935 standard identifies four categories of use for single-axis hinges: grade 1 (light duty), grade 2 (medium duty), grade 3 (heavy duty), and grade 4 (severe duty). These categories differentiate hinges based on their suitability for varying intensities of use; light duty hinges are intended for less frequent usage scenarios, while severe duty hinges are designed for more demanding applications, likely encountering frequent or heavy use .

The BS EN 1935 standard guides the assessment of single-axis hinges for fire/smoke door suitability by identifying two grades: grade 0 (not suitable for fire/smoke door assemblies) and grade 1 (suitable for such assemblies). However, it notes that the assessment of how a hinge contributes to the fire resistance of a door assembly is beyond its scope and should be evaluated based on EN 1634-1 .

The collaboration between dhf, GAI, and the MLA enhances the effectiveness of best practice standards by pooling together a wealth of expertise and resources. dhf provides a unified industry voice, driving innovation and adherence to performance standards, the GAI advances product design and professional scheduling within architectural ironmongery, and the MLA ensures high security standards through rigorous licensing and inspections. This synergy results in a comprehensive approach to industry standards, promoting high-quality, reliable products across sectors and reassuring stakeholders, including consumers who benefit from enhanced product safety and reliability .

When affixing the CE marking, a manufacturer is responsible for designing and producing the product to meet the requirements of the Directive, ensuring its compliance, and affixing the CE mark only after the product has been verified by a notified certification body. This process involves obtaining an EC Certificate of Conformity from the notified body, which confirms compliance to the standards before the CE marking is applied .

The CE marking is significant for single-axis hinges as it indicates compliance with the European standards, specifically for fire resisting and smoke control doors under the Construction Products Directive. A notified certification body plays a critical role in verifying compliance by conducting initial type-testing, inspecting manufacturer’s production controls, and providing ongoing surveillance to ensure continued conformity . This ensures that products meet the necessary safety and performance standards before being placed on the market.

The dhf contributes to maintaining quality standards by setting minimum competency and customer service standards for its members and enforcing a Code of Conduct which includes workmanship, quality assurance, training, and safety. It unifies resources from its predecessor organizations to represent key sectors in the building hardware industry. Its activities include providing technical expertise, developing performance standards, and offering support services from product specification through to effective operation .