1. Lineup
2.2 kW 2.8 kW 3.6 kW 4.5 kW 5.6 kW 7.1 kW 9.0 kW 11.2 kW 14.0 kW 16.0 kW
Capacity range
0.8 HP 1 HP 1.25 HP 1.6 HP 2 HP 2.5 HP 3.2 HP 4 HP 5 HP 6 HP
Capacity index 20 25 31.25 40 50 62.5 80 100 125 140
FXMQ 20PAVE 25PAVE 32PAVE 40PAVE 50PAVE 63PAVE 80PAVE 100PAVE 125PAVE 140PAVE
VE: 1 phase, 220-240/220 V, 50/60 Hz
278
FXMQ-PAVE EDMT391908
2.
Model FXMQ20PAVE FXMQ25PAVE
Power supply 1 phase, 220-240/220 V, 50/60 Hz 1 phase, 220-240/220 V, 50/60 Hz
kcal/h 1,900 2,400
1 3 Cooling capacity Btu/h 7,500 9,600
kW 2.2 2.8
kcal/h 2,200 2,800
2 3 Heating capacity Btu/h 8,500 10,900
kW 2.5 3.2
50 Hz kW 0.056 0.056
Cooling
7 60 Hz kW 0.056 0.056
Power input 50 Hz kW 0.044 0.044
Heating
60 Hz kW 0.044 0.044
Casing / Colour Galvanized steel plate Galvanized steel plate
Dimensions: (H×W×D) mm 300×550×700 300×550×700
Rows × Stages ×
Coil (Cross Fin pitch mm 3×16×1.75 3×16×1.75
Face area m 2
0.098 0.098
Model — —
Type Sirocco fan Sirocco fan
Motor output × W 90×1 90×1
Number of units
m³/min 9/7.5/6.5 9/7.5/6.5
Fan
(HH/H/L) l/s 150/125/108 150/125/108 12
cfm 318/265/230 318/265/230
External static
pressure Pa Rated 50 (100-30 4) Rated 50 (100-30 4)
Drive Direct drive Direct drive
Temperature control Microprocessor thermostat for Microprocessor thermostat for
cooling and heating cooling and heating
— 5 — 5
Liquid pipes mm 6.4 (Flare connection) 6.4 (Flare connection)
Piping Gas pipes mm 12.7 (Flare connection) 12.7 (Flare connection)
connections VP25 VP25
Drain pipe mm External dia. 32 External dia. 32
(Internal dia. 25 ) (Internal dia. 25 )
Mass kg 25 25
6 Sound pressure level dB(A) 33/31/29 33/31/29
(HH/H/L)
Sound power level (H) dB 51 51
Safety devices Fuse, Fan driver overload protector Fuse, Fan driver overload protector
Refrigerant control Electronic expansion valve Electronic expansion valve
Operation manual, Installation manual, Drain Operation manual, Installation manual, Drain
Standard accessories hose, Sealing pads, Clamps, Washers, Screws, hose, Sealing pads, Clamps, Washers, Screws,
C: 3D105230B C: 3D105230B
Drawing No.
Sound level C: 4D062535A C: 4D062535A
Notes:
1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Rated external static pressure / Equivalent piping Conversion formulae
length: 7.5 m, level difference: 0 m. kcal/h=kW×860
2. Indoor temp.: 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Rated external static pressure / Equivalent piping length: Btu/h=kW×3412
7.5 m, level difference: 0 m. cfm=m³/min×35.3
3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. l/s=m³/min×1000/60
4. External static pressure is changeable in 7 stages (FXMQ20/25/32PAVE), 13 stages (FXMQ40PAVE), 14 stages
(FXMQ50/63/80/100/125PAVE), 10 stages (FXMQ140PAVE) within the ( ) range by remote controller.
6. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual
operation, these values are normally somewhat higher as a result of ambient conditions.
7. Power input values are based on conditions of rated external static pressure.
8. Refer to Electric Characteristics
static pressure.
279
FXMQ-PAVE EDMT391908
Model FXMQ32PAVE FXMQ40PAVE
Power supply 1 phase, 220-240/220 V, 50/60 Hz 1 phase, 220-240/220 V, 50/60 Hz
kcal/h 3,100 3,900
1 3 Cooling capacity Btu/h 12,300 15,400
kW 3.6 4.5
kcal/h 3,400 4,300
2 3 Heating capacity Btu/h 13,600 17,100
kW 4.0 5.0
50 Hz kW 0.060 0.151
Cooling
7 60 Hz kW 0.059 0.150
Power input 50 Hz kW 0.048 0.139
Heating
60 Hz kW 0.048 0.139
Casing / Colour Galvanized steel plate Galvanized steel plate
Dimensions: (H×W×D) mm 300×550×700 300×700×700
Rows × Stages ×
Coil (Cross Fin pitch mm 3×16×1.75 3×16×1.75
Face area m 2
0.098 0.148
Model — —
Type Sirocco fan Sirocco fan
Motor output × W 90×1 140×1
Number of units
m³/min 9.5/8/7 16/13/11
Fan
(HH/H/L) l/s 158/133/116 267/216/183
cfm 335/282/247 565/459/388
External static
pressure Pa Rated 50 (100-30 4) Rated 100 (160-30 4)
Drive Direct drive Direct drive
Temperature control Microprocessor thermostat for Microprocessor thermostat for
cooling and heating cooling and heating
— 5 — 5
Liquid pipes mm 6.4 (Flare connection) 6.4 (Flare connection)
Piping Gas pipes mm 12.7 (Flare connection) 12.7 (Flare connection)
connections VP25 VP25
Drain pipe mm External dia. 32 External dia. 32
(Internal dia. 25 ) (Internal dia. 25 )
Mass kg 25 27
6 Sound pressure level dB(A) 34/32/30 39/37/35
(HH/H/L)
Sound power level (H) dB 52 57
Safety devices Fuse, Fan driver overload protector Fuse, Fan driver overload protector
Refrigerant control Electronic expansion valve Electronic expansion valve
Operation manual, Installation manual, Drain Operation manual, Installation manual, Drain
Standard accessories hose, Sealing pads, Clamps, Washers, Screws, hose, Sealing pads, Clamps, Washers, Screws,
C: 3D105230B C: 3D105230B
Drawing No.
Sound level C: 4D062536A C: 4D060446C
Notes:
1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Rated external static pressure / Equivalent piping Conversion formulae
length: 7.5 m, level difference: 0 m. kcal/h=kW×860
2. Indoor temp.: 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Rated external static pressure / Equivalent piping length: Btu/h=kW×3412
7.5 m, level difference: 0 m. cfm=m³/min×35.3
3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. l/s=m³/min×1000/60
4. External static pressure is changeable in 7 stages (FXMQ20/25/32PAVE), 13 stages (FXMQ40PAVE), 14 stages
(FXMQ50/63/80/100/125PAVE), 10 stages (FXMQ140PAVE) within the ( ) range by remote controller.
6. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual
operation, these values are normally somewhat higher as a result of ambient conditions.
7. Power input values are based on conditions of rated external static pressure.
8. Refer to Electric Characteristics
static pressure.
280
FXMQ-PAVE EDMT391908
Model FXMQ50PAVE FXMQ63PAVE
Power supply 1 phase, 220-240/220 V, 50/60 Hz 1 phase, 220-240/220 V, 50/60 Hz
kcal/h 4,800 6,100
1 3 Cooling capacity Btu/h 19,100 24,200
kW 5.6 7.1
kcal/h 5,400 6,900
2 3 Heating capacity Btu/h 21,500 27,300
kW 6.3 8.0
50 Hz kW 0.128 0.138
Cooling
7 60 Hz kW 0.127 0.138
Power input 50 Hz kW 0.116 0.127
Heating
60 Hz kW 0.116 0.127
Casing / Colour Galvanized steel plate Galvanized steel plate
Dimensions: (H×W×D) mm 300×1,000×700 300×1,000×700
Rows × Stages ×
Coil (Cross Fin pitch mm 3×16×1.75 3×16×1.75
Face area m 2
0.249 0.249
Model — —
Type Sirocco fan Sirocco fan
Motor output × W 350×1 350×1
Number of units
m³/min 18/16.5/15 19.5/17.5/16
Fan
(HH/H/L) l/s 300/275/250 325/292/267 12
cfm 635/582/530 688/618/565
External static
pressure Pa Rated 100 (200-50 4) Rated 100 (200-50 4)
Drive Direct drive Direct drive
Temperature control Microprocessor thermostat for Microprocessor thermostat for
cooling and heating cooling and heating
— 5 — 5
Liquid pipes mm 6.4 (Flare connection) 9.5 (Flare connection)
Piping Gas pipes mm 12.7 (Flare connection) 15.9 (Flare connection)
connections VP25 VP25
Drain pipe mm External dia. 32 External dia. 32
(Internal dia. 25 ) (Internal dia. 25 )
Mass kg 35 35
6 Sound pressure level dB(A) 41/39/37 42/40/38
(HH/H/L)
Sound power level (H) dB 59 60
Safety devices Fuse, Fan driver overload protector Fuse, Fan driver overload protector
Refrigerant control Electronic expansion valve Electronic expansion valve
Operation manual, Installation manual, Drain Operation manual, Installation manual, Drain
Standard accessories hose, Sealing pads, Clamps, Washers, Screws, hose, Sealing pads, Clamps, Washers, Screws,
C: 3D105230B C: 3D105230B
Drawing No.
Sound level C: 4D060428C C: 4D060447C
Notes:
1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Rated external static pressure / Equivalent piping Conversion formulae
length: 7.5 m, level difference: 0 m. kcal/h=kW×860
2. Indoor temp.: 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Rated external static pressure / Equivalent piping length: Btu/h=kW×3412
7.5 m, level difference: 0 m. cfm=m³/min×35.3
3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. l/s=m³/min×1000/60
4. External static pressure is changeable in 7 stages (FXMQ20/25/32PAVE), 13 stages (FXMQ40PAVE), 14 stages
(FXMQ50/63/80/100/125PAVE), 10 stages (FXMQ140PAVE) within the ( ) range by remote controller.
6. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual
operation, these values are normally somewhat higher as a result of ambient conditions.
7. Power input values are based on conditions of rated external static pressure.
8. Refer to Electric Characteristics
static pressure.
281
FXMQ-PAVE EDMT391908
Model FXMQ80PAVE FXMQ100PAVE
Power supply 1 phase, 220-240/220 V, 50/60 Hz 1 phase, 220-240/220 V, 50/60 Hz
kcal/h 7,700 9,600
1 3 Cooling capacity Btu/h 30,700 38,200
kW 9.0 11.2
kcal/h 8,600 10,800
2 3 Heating capacity Btu/h 34,100 42,700
kW 10.0 12.5
50 Hz kW 0.185 0.215
Cooling
7 60 Hz kW 0.184 0.214
Power input 50 Hz kW 0.173 0.203
Heating
60 Hz kW 0.173 0.203
Casing / Colour Galvanized steel plate Galvanized steel plate
Dimensions: (H×W×D) mm 300×1,000×700 300×1,400×700
Rows × Stages ×
Coil (Cross Fin pitch mm 3×16×1.75 3×16×1.75
Face area m 2
0.249 0.383
Model — —
Type Sirocco fan Sirocco fan
Motor output × W 350×1 350×1
Number of units
m³/min 25/22.5/20 32/27/23
Fan
(HH/H/L) l/s 417/375/333 533/450/383
cfm 883/794/706 1,130/953/812
External static
pressure Pa Rated 100 (200-50 4) Rated 100 (200-50 4)
Drive Direct drive Direct drive
Temperature control Microprocessor thermostat for Microprocessor thermostat for
cooling and heating cooling and heating
— 5 — 5
Liquid pipes mm 9.5 (Flare connection) 9.5 (Flare connection)
Piping Gas pipes mm 15.9 (Flare connection) 15.9 (Flare connection)
connections VP25 VP25
Drain pipe mm External dia. 32 External dia. 32
(Internal dia. 25 ) (Internal dia. 25 )
Mass kg 35 45
6 Sound pressure level dB(A) 43/41/39 43/41/39
(HH/H/L)
Sound power level (H) dB 61 61
Safety devices Fuse, Fan driver overload protector Fuse, Fan driver overload protector
Refrigerant control Electronic expansion valve Electronic expansion valve
Operation manual, Installation manual, Drain Operation manual, Installation manual, Drain
Standard accessories hose, Sealing pads, Clamps, Washers, Screws, hose, Sealing pads, Clamps, Washers, Screws,
C: 3D105230B C: 3D105230B
Drawing No.
Sound level C: 4D060429C C: 4D060448C
Notes:
1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Rated external static pressure / Equivalent piping Conversion formulae
length: 7.5 m, level difference: 0 m. kcal/h=kW×860
2. Indoor temp.: 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Rated external static pressure / Equivalent piping length: Btu/h=kW×3412
7.5 m, level difference: 0 m. cfm=m³/min×35.3
3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. l/s=m³/min×1000/60
4. External static pressure is changeable in 7 stages (FXMQ20/25/32PAVE), 13 stages (FXMQ40PAVE), 14 stages
(FXMQ50/63/80/100/125PAVE), 10 stages (FXMQ140PAVE) within the ( ) range by remote controller.
6. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual
operation, these values are normally somewhat higher as a result of ambient conditions.
7. Power input values are based on conditions of rated external static pressure.
8. Refer to Electric Characteristics
static pressure.
282
FXMQ-PAVE EDMT391908
Model FXMQ125PAVE FXMQ140PAVE
Power supply 1 phase, 220-240/220 V, 50/60 Hz 1 phase, 220-240/220 V, 50/60 Hz
kcal/h 12,000 13,800
1 3 Cooling capacity Btu/h 47,800 54,600
kW 14.0 16.0
kcal/h 13,800 15,500
2 3 Heating capacity Btu/h 54,600 61,400
kW 16.0 18.0
50 Hz kW 0.284 0.405
Cooling
7 60 Hz kW 0.283 0.404
Power input 50 Hz kW 0.272 0.380
Heating
60 Hz kW 0.272 0.380
Casing / Colour Galvanized steel plate Galvanized steel plate
Dimensions: (H×W×D) mm 300×1,400×700 300×1,400×700
Rows × Stages ×
Coil (Cross Fin pitch mm 3×16×1.75 3×16×1.5
Face area m 2
0.383 0.383
Model — —
Type Sirocco fan Sirocco fan
Motor output × W 350×1 350×1
Number of units
m³/min 39/33/28 46/39/32
Fan
(HH/H/L) l/s 650/550/466 767/650/533 12
cfm 1,377/1,165/988 1,624/1,377/1,130
External static
pressure Pa Rated 100 (200-50 4) Rated 100 (140-50 4)
Drive Direct drive Direct drive
Temperature control Microprocessor thermostat for Microprocessor thermostat for
cooling and heating cooling and heating
— 5 — 5
Liquid pipes mm 9.5 (Flare connection) 9.5 (Flare connection)
Piping Gas pipes mm 15.9 (Flare connection) 15.9 (Flare connection)
connections VP25 VP25
Drain pipe mm External dia. 32 External dia. 32
(Internal dia. 25 ) (Internal dia. 25 )
Mass kg 45 46
6 Sound pressure level dB(A) 44/42/40 46/45/43
(HH/H/L)
Sound power level (H) dB 62 64
Safety devices Fuse, Fan driver overload protector Fuse, Fan driver overload protector
Refrigerant control Electronic expansion valve Electronic expansion valve
Operation manual, Installation manual, Drain Operation manual, Installation manual, Drain
Standard accessories hose, Sealing pads, Clamps, Washers, Screws, hose, Sealing pads, Clamps, Washers, Screws,
C: 3D105230B C: 3D105230B
Drawing No.
Sound level C: 4D060449C C: 4D063786A
Notes:
1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Rated external static pressure / Equivalent piping Conversion formulae
length: 7.5 m, level difference: 0 m. kcal/h=kW×860
2. Indoor temp.: 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Rated external static pressure / Equivalent piping length: Btu/h=kW×3412
7.5 m, level difference: 0 m. cfm=m³/min×35.3
3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. l/s=m³/min×1000/60
4. External static pressure is changeable in 7 stages (FXMQ20/25/32PAVE), 13 stages (FXMQ40PAVE), 14 stages
(FXMQ50/63/80/100/125PAVE), 10 stages (FXMQ140PAVE) within the ( ) range by remote controller.
6. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual
operation, these values are normally somewhat higher as a result of ambient conditions.
7. Power input values are based on conditions of rated external static pressure.
8. Refer to Electric Characteristics
static pressure.
283