A B C D E
1
DIAGRAMA DE CONEXIONES 1
SAMSUNG INVERTER SERIE RT
2 2
PLC Port INVERTER_SIGNAL R ROOM - LOAD (FREEZER)
CN01 (BLU) CN70 (PUERTO DE COMUNICACIÓN) CN31 (REFRIGERADOR)
1 2 3 4 5 6 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11
1: Vcc 1: R-DOOR SW (PULSADOR)
2: GND 2: GND
3: COMP. SIGNAL 3: R-DEF-SENSOR
4: F/B 4: GND
5: R-SELECTOR ROTATIVO SW
6: GND
7: R-SENSOR
8: GND
9: R-FAN F/G
10: R-FAN
11: GND
3 3
F ROOM - LOAD (FREEZER) BOX_FAN / PUMP MOTOR EXT_SENSOR
CN30 (CONGELADOR) CN33 CN32 (SENSOR DE TEMP. EXTERNO)
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 1 2
1: ANTIBACK F/B (NC) 1: ANTI BACTERIA 1: EXT_SENSOR
2: F-SELECTOR ROTATIVO SW 2: GND 2: GND
3: GND 3: NC (NO CONECTAR)
4: F-DEF-SENSOR 4: PUMP MOTOR
5: GND 5: GND
6: F-SENSOR
4 7: GND 4
8: F-FAN F/G
9: F-FAN
10: GND
STEP VALVE
CN74 (VALVULA 3 VIAS_M PAP)
B1 PROGRAM LED_LAMP
1 2 3 4 5 6
CN00 (PUERTO DE PROGRAMACIÓN) CN75
M
C1
1: B1 B2
2: A1 1 2 3 4 1 2 3
3: +12VDC (C1 Y C2) M_PAP A1 C2 A2
4: NC (NO CONECTAR)
5 5: B2 1: R ROOM LAMP_ANODO 5
6: A2 2: GND
3: NC (NO CONECTAR)
AC LOAD (RELÉ)
CN73 (RESISTENCIA_DESHIELO)
TARJETA PRINCIPAL SAMSUNG
1: L2 (RESISTENCIA_DESHIELO)
2
2: NC (NO CONECTAR)
RT6000K
1
6 6
AC LOAD
CN72 (AC SALIDA)
1: EARTH (TIERRA)
7
2: NC (NO CONECTAR)
3: N2 (RESISTENCIA_DESHIELO)
6
4: NC (NO CONECTAR)
5: N2 (TARJETA INVERSORA)
5
6: NC (NO CONECTAR)
7: L2 (TARJETA INVERSORA)
4
3
2
1
7 7
AC INPUT
CN71 (ALIMENTACIÓN 220VAC)
1: L1 (LINEA)
3
2: NC (NO CONECTAR)
3: N1 (NEUTRO)
2
1
8 8