0% found this document useful (0 votes)
27 views20 pages

Industrial Photoelectric Sensors

Uploaded by

saadane.khalfi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views20 pages

Industrial Photoelectric Sensors

Uploaded by

saadane.khalfi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

PHOTOELECTRIC SENSORS

E3FA/E3RA/E3FB/E3RB
M18 Plastic and Metal Housing Sensors
• Universal M18 cylindrical plastic or nickel-plated brass housing in straight
or 90° angled models
• Rugged IP67, IP69K housing withstands high-pressure and
high-temperature wash down
• High power red LED for easy sensor alignment and dependable outputs
in dusty environments
• Compact and robust housing for easy integration into machines
• Retro-reflective models are polarized to prevent false reads on mirrored surfaces
• High EMC protection and ambient light immunity for detection stability
in environments with excess noise or background light

Unrivaled Detection with Simplicity in Setup and Installation

The short body of the E3FA/E3RA fits in Visible red LED light for easy alignment. Transparent object detection sensors utilize
tighter mounting spaces. Omron’s unique technology for detecting
objects with birefringent (double refraction)
properties.

Bright LED indicators for status visibility Flush mounting option for quick and High power LED to compensate for dirt
and large sensor adjustors for use with a easy installation. and misalignment.
standard size screwdriver.

1
E3FA/E3RA/E3FB/E3RB
Ordering Information

Sensors (E3FA Plastic housing) [Refer to Dimensions on page 16.] Red light Infrared light

Model
Sensor type Sensing distance Connection method
NPN output PNP output
Through-beam *1. set E3FA-TN11 2M set E3FA-TP11 2M
pre-wired Emitter E3FA-TN11-L 2M Emitter E3FA-TP11-L 2M
Receiver E3FA-TN11-D 2M Receiver E3FA-TP11-D 2M
20 m
set E3FA-TN21 set E3FA-TP21
M12 connector Emitter E3FA-TN21-L Emitter E3FA-TP21-L
Receiver E3FA-TN21-D Receiver E3FA-TP21-D
set E3FA-TN12 2M set E3FA-TP12 2M
pre-wired Emitter E3FA-TN12-L 2M Emitter E3FA-TP12-L 2M
Receiver E3FA-TN12-D 2M Receiver E3FA-TP12-D 2M
15 m
set E3FA-TN22 set E3FA-TP22
M12 connector Emitter E3FA-TN22-L Emitter E3FA-TP22-L
Receiver E3FA-TN22-D Receiver E3FA-TP22-D
Retro-reflective with MSR
pre-wired E3FA-RN11 2M E3FA-RP11 2M
function *2.
0.1 to 4 m
with E39-R1S M12 connector E3FA-RN21 E3FA-RP21
Coaxial Retro-reflective with
pre-wired E3FA-RN12 2M E3FA-RP12 2M
MSR function *2.
0 to 500 mm
with E39-R1S M12 connector E3FA-RN22 E3FA-RP22
Diffuse-reflective pre-wired E3FA-DN11 2M E3FA-DP11 2M
100 mm
M12 connector E3FA-DN21 E3FA-DP21
pre-wired E3FA-DN12 2M E3FA-DP12 2M
300 mm
M12 connector E3FA-DN22 E3FA-DP22
pre-wired E3FA-DN13 2M E3FA-DP13 2M
1m
M12 connector E3FA-DN23 E3FA-DP23
pre-wired E3FA-DN14 2M E3FA-DP14 2M
100 mm
M12 connector E3FA-DN24 E3FA-DP24
pre-wired E3FA-DN15 2M E3FA-DP15 2M
300 mm
M12 connector E3FA-DN25 E3FA-DP25
pre-wired E3FA-DN16 2M E3FA-DP16 2M
1m
M12 connector E3FA-DN26 E3FA-DP26
BGS pre-wired E3FA-LN11 2M E3FA-LP11 2M
(background suppression) 100 mm
M12 connector E3FA-LN21 E3FA-LP21
pre-wired E3FA-LN12 2M E3FA-LP12 2M
200 mm
M12 connector E3FA-LN22 E3FA-LP22
Limited distance reflective
pre-wired E3FA-VN11 2M E3FA-VP11 2M
10 to 50 mm
M12 connector E3FA-VN21 E3FA-VP21
Transparent detected with
P-opaquing function *2. pre-wired E3FA-BN11 2M E3FA-BP11 2M
100 to 500 mm
with E39-RP1 M12 connector E3FA-BN21 E3FA-BP21

Transparent detected with


P-opaquing function *2. pre-wired E3FA-BN12 2M E3FA-BP12 2M
0.1 to 2 m
with E39-RP1 M12 connector E3FA-BN22 E3FA-BP22

*1. The set type includes the emitter and receiver.


*2. The Reflector is sold separately. Select the Reflector model most suited to the application.

2
E3FA/E3RA/E3FB/E3RB

Sensors (E3RA Plastic housing) [Refer to Dimensions on page 16.] Red light
Model
Sensor type Sensing distance Connection method
NPN output PNP output
Through-beam *1. set E3RA-TN11 2M set E3RA-TP11 2M
pre-wired Emitter E3RA-TN11-L 2M Emitter E3RA-TP11-L 2M
Receiver E3RA-TN11-D 2M Receiver E3RA-TP11-D 2M
15 m
set E3RA-TN21 set E3RA-TP21
M12 connector Emitter E3RA-TN21-L Emitter E3RA-TP21-L
Receiver E3RA-TN21-D Receiver E3RA-TP21-D
Retro-reflective with MSR
function *2. pre-wired E3RA-RN11 2M E3RA-RP11 2M

0.1 to 3 m
with E39-R1S
M12 connector E3RA-RN21 E3RA-RP21

Diffuse-reflective pre-wired E3RA-DN11 2M E3RA-DP11 2M


100 mm
M12 connector E3RA-DN21 E3RA-DP21
pre-wired E3RA-DN12 2M E3RA-DP12 2M
300 mm
M12 connector E3RA-DN22 E3RA-DP22
pre-wired E3RA-DN13 2M E3RA-DP13 2M
700 mm
M12 connector E3RA-DN23 E3RA-DP23
*1. The set type includes the emitter and receiver.
*2. The Reflector is sold separately. Select the Reflector model most suited to the application.

3
E3FA/E3RA/E3FB/E3RB

Sensors (E3FB/E3RB Metal housing) [Refer to Dimensions on page 17.] Red light
Model
Sensor type Sensing distance Connection method
NPN output PNP output
Through-beam *1. set E3FB-TN11 2M set E3FB-TP11 2M
pre-wired Emitter E3FB-TN11-L 2M Emitter E3FB-TP11-L 2M
Receiver E3FB-TN11-D 2M Receiver E3FB-TP11-D 2M
20 m
set E3FB-TN21 set E3FB-TP21
M12 connector Emitter E3FB-TN21-L Emitter E3FB-TP21-L
Receiver E3FB-TN21-D Receiver E3FB-TP21-D
Retro-reflective with MSR
pre-wired E3FB-RN11 2M E3FB-RP11 2M
function *2.
0.1 to 4 m
with E39-R1S M12 connector E3FB-RN21 E3FB-RP21
Coaxial Retro-reflective with
pre-wired E3FB-RN12 2M E3FB-RP12 2M
MSR function *2.
0 to 500 mm
with E39-R1S M12 connector E3FB-RN22 E3FB-RP22
Diffuse-reflective pre-wired E3FB-DN11 2M E3FB-DP11 2M
100 mm
M12 connector E3FB-DN21 E3FB-DP21
pre-wired E3FB-DN12 2M E3FB-DP12 2M
300 mm
M12 connector E3FB-DN22 E3FB-DP22
pre-wired E3FB-DN13 2M E3FB-DP13 2M
1m
M12 connector E3FB-DN23 E3FB-DP23
BGS pre-wired E3FB-LN11 2M E3FB-LP11 2M
(background suppression) 100 mm
M12 connector E3FB-LN21 E3FB-LP21
pre-wired E3FB-LN12 2M E3FB-LP12 2M
200 mm
M12 connector E3FB-LN22 E3FB-LP22
Limited distance reflective
pre-wired E3FB-VN11 2M E3FB-VP11 2M
10 to 50 mm
M12 connector E3FB-VN21 E3FB-VP21
Transparent detected with
P-opaquing function *2. pre-wired E3FB-BN11 2M E3FB-BP11 2M
100 to 500 mm
with E39-RP1 M12 connector E3FB-BN21 E3FB-BP21

Transparent detected with


P-opaquing function *2. pre-wired E3FB-BN12 2M E3FB-BP12 2M
0.1 to 2 m
with E39-RP1 M12 connector E3FB-BN22 E3FB-BP22

Through-beam *1. set E3RB-TN11 2M set E3RB-TP11 2M


pre-wired Emitter E3RB-TN11-L 2M Emitter E3RB-TP11-L 2M
Receiver E3RB-TN11-D 2M Receiver E3RB-TP11-D 2M
15 m
set E3RB-TN21 set E3RB-TP21
M12 connector Emitter E3RB-TN21-L Emitter E3RB-TP21-L
Receiver E3RB-TN21-D Receiver E3RB-TP21-D
Retro-reflective with MSR
function *2. pre-wired E3RB-RN11 2M E3RB-RP11 2M

0.1 to 3 m
with E39-R1S
M12 connector E3RB-RN21 E3RB-RP21

Diffuse-reflective pre-wired E3RB-DN11 2M E3RB-DP11 2M


100 mm
M12 connector E3RB-DN21 E3RB-DP21
pre-wired E3RB-DN12 2M E3RB-DP12 2M
300 mm
M12 connector E3RB-DN22 E3RB-DP22
pre-wired E3RB-DN13 2M E3RB-DP13 2M
700 mm
M12 connector E3RB-DN23 E3RB-DP23
*1. The set type includes the emitter and receiver.
*2. The Reflector is sold separately. Select the Reflector model most suited to the application.

4
E3FA/E3RA/E3FB/E3RB

Reflectors [Refer to Dimensions on page 18.]


Reflectors required for Retro-reflective Sensors: A Reflector is not provided with the Sensor. Be sure to order a Reflector separately.
Sensor Sensing distance Appearance Model Quantity Remarks

E3FA-R@1
0.1 to 4 m
E3FB-R@1
for E3FA-R@, E3RA-R@,
E39-R1S 1
E3FB-R@ and E3RB-R@
E3FA-R@2
0 to 500 mm
E3FB-R@2

E3FA-B@1
100 to 500 mm
E3FB-B@1
E39-RP1 1 for E3FA-B@ and E3FB-B@
E3FA-B@2
0.1 to 2 m
E3FB-B@2

Mounting brackets [Refer to Dimensions on page 18.]


A Mounting Bracket is not enclosed with the Sensor. Order a Mounting Bracket separately if required.
Sensor Appearance Model (Material) Quantity Remarks

all types E39-L183 (SUS304) 1 Mounting bracket

E3FA-@
E39-L182 (POM) 1 Flush mounting bracket
E3RA-@

Sensor I/O connectors


Models for Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.
Sensor Size Cable Appearance Cable type Model
2m XS2F-M12PVC4S2M
Straight
5m XS2F-M12PVC4S5M
M12 connector types M12 Standard 4-wire
2m XS2F-M12PVC4A2M
Angle
5m XS2F-M12PVC4A5M

Model Number Legend


E3@-@@@@-(@)@
–1 –2 –3 –4 –5 –6 –7
1. Series name 6. Emitter/Receiver
FA: Cylindrical, Straight type, Plastic housing D: Receiver
RA: Cylindrical, Radial type, Plastic housing L: Emitter
FB: Cylindrical, Straight type, Metal housing
7. Cable length
RB: Cylindrical, Radial type, Metal housing
Blank: Connector type
2. Sensing method
e.g., E3FA-TP11 2M;
T: Through-beam
R: Retro-reflective with MSR function Cylindrical, Straight type, Plastic housing/ Through-beam/ PNP/
D: Diffuse-reflective Cable/ Difference of Sensing distance/ Cable length of 2M
L: Background suppression E3RA-TN12-D;
V: Limited distance reflective Cylindrical, Radial type, Plastic housing/ Through-beam/ NPN/
B: Transparent detected with P-opaquing function Connector, M12, 4-pin/ Difference of Sensing distance/
Receiver/ Connector type
3. Output E3FA-VP12;
P: PNP Cylindrical, Straight type, Plastic housing/ Limited distance
N: NPN reflective/ PNP/ Connector, M12, 4-pin/ Difference of Sensing
distance/ Connector type
4. Connection
1: Cable
2: Connector, M12, 4-pin

5. Difference of sensing distance, difference of light source


Sequential number

5
E3FA/E3RA/E3FB/E3RB
Ratings and Specifications
Straight type (E3FA/E3FB)
Retro-reflective with Coaxial Retro-reflective
Sensing method Through-beam
MSR function with MSR function
Model NPN Pre-wired E3F@-TN11 2M E3FA-TN12 2M E3F@-RN11 2M E3F@-RN12 2M
output M12 Connector E3F@-TN21 E3FA-TN22 E3F@-RN21 E3F@-RN22
PNP Pre-wired E3F@-TP11 2M E3FA-TP12 2M E3F@-RP11 2M E3F@-RP12 2M
Item output M12 Connector E3F@-TP21 E3FA-TP22 E3F@-RP21 E3F@-RP22
0.1 to 4 m 0 to 500 mm
Sensing distance 20 m 15 m
(with E39-R1S) (with E39-R1S)
Spot diameter (reference value) —
Standard sensing object Opaque: 7 mm dia.min. Opaque: 75 mm dia.min.
Differential travel —
Directional angle 2 min.
Light source (wavelength) Red LED (624 nm) Infrared LED (850 nm) Red LED (624 nm)
Power supply voltage 10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
40 mA max.
Current consumption 25 mA max.
(Emitter 25 mA max. Receiver 15 mA max.)
NPN/PNP (open collector)
Control output
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max.
Operation mode Light-ON/Dark-ON selectable by wiring
Operation indicator (orange)
Indicator Stability indicator (green)
Power indicator (green): only Emitter of Through-beam
Protection circuits Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection
Response time 0.5 ms
Sensitivity adjustment One-turn adjuster
Ambient illumination (Receiver side) Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max.
Ambient temperature range Operating: -25 to 55C/ Storage: -30 to 70C (with no icing or condensation)
Ambient humidity range Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y and Z directions
Degree of protection IEC: IP67, DIN 40050-9: IP69K *
Weight E3FA: Approx. 110 g/ Approx. 50 g, respectively, E3FA: Approx. 60 g/ Approx. 50 g,
Pre-wired cable (2M)
(packed E3FB: Approx. 175 g/ Approx. 65 g, respectively E3FB: Approx. 95 g/ Approx. 65 g
state/only E3FA: Approx. 30 g/ Approx. 10 g, respectively, E3FA: Approx. 20 g/ Approx. 10 g,
sensor) Connector
E3FB: Approx. 85 g/ Approx. 20 g, respectively E3FB: Approx. 50 g/ Approx. 20 g
Case E3FA: ABS, E3FB: Nickel-brass
Lens and Display PMMA
Material
Adjuster POM
Nut E3FA: POM, E3FB: Nickel-brass
Instruction sheet Instruction sheet
Accessories
M18 nuts (4 pcs) M18 nuts (2 pcs)
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water
is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0, 30, 60, and 90 from
the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.

6
E3FA/E3RA/E3FB/E3RB

Straight type (E3FA/E3FB)


Sensing method Diffuse-reflective
Model NPN Pre-wired E3F@-DN11 2M E3F@-DN12 2M E3F@-DN13 2M E3FA-DN14 2M E3FA-DN15 2M E3FA-DN16 2M
output M12 Connector E3F@-DN21 E3F@-DN22 E3F@-DN23 E3FA-DN24 E3FA-DN25 E3FA-DN26
PNP Pre-wired E3F@-DP11 2M E3F@-DP12 2M E3F@-DP13 2M E3FA-DP14 2M E3FA-DP15 2M E3FA-DP16 2M
Item output M12 Connector E3F@-DP21 E3F@-DP22 E3F@-DP23 E3FA-DP24 E3FA-DP25 E3FA-DP26
100 mm 300 mm 1m 100 mm 300 mm 1m
Sensing distance (white paper: (white paper: (white paper: (white paper: (white paper: (white paper:
300  300 mm) 300  300 mm) 300  300 mm) 300  300 mm) 300  300 mm) 300  300 mm)
40  45 mm 40  50 mm 120  150 mm 40  45 mm 40  50 mm 120  150 mm
Spot diameter (reference value) Sensing distance Sensing distance Sensing distance Sensing distance Sensing distance Sensing distance
of 100 mm of 300 mm of 1 m of 100 mm of 300 mm of 1 m
Standard sensing object —
Differential travel 20% max.
Directional angle —
Light source (wavelength) Red LED (624 nm) Infrared LED (850 nm)
Power supply voltage 10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
Current consumption 25 mA max.
NPN/PNP (open collector)
Control output
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max.
Operation mode Light-ON/Dark-ON selectable by wiring
Operation indicator (orange)
Indicator
Stability indicator (green)
Protection circuits Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection
Response time 0.5 ms
Sensitivity adjustment One-turn adjuster
Ambient illumination (Receiver side) Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max.
Ambient temperature range Operating: -25 to 55C/ Storage: -30 to 70C (with no icing or condensation)
Ambient humidity range Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y and Z directions
Degree of protection IEC: IP67, DIN 40050-9: IP69K *
Weight E3FA: Approx. 60 g/ Approx. 50 g,
Pre-wired cable (2M)
(packed E3FB: Approx. 95 g/ Approx. 65 g
state/only E3FA: Approx. 20 g/ Approx. 10 g,
sensor) Connector
E3FB: Approx. 50 g/ Approx. 20 g
Case E3FA: ABS, E3FB: Nickel-brass
Lens and Display PMMA
Material
Adjuster POM
Nut E3FA: POM, E3FB: Nickel-brass
Instruction sheet
Accessories
M18 nuts (2 pcs)
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water
is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0, 30, 60, and 90 from
the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.

7
E3FA/E3RA/E3FB/E3RB

Straight type (E3FA/E3FB)


Limited distance Transparent detected with
Sensing method BGS (Background suppression)
reflective P-opaquing function
Model NPN Pre-wired E3F@-LN11 2M E3F@-LN12 2M E3F@-VN11 2M E3F@-BN11 2M E3F@-BN12 2M
output M12 Connector E3F@-LN21 E3F@-LN22 E3F@-VN21 E3F@-BN21 E3F@-BN22
PNP Pre-wired E3F@-LP11 2M E3F@-LP12 2M E3F@-VP11 2M E3F@-BP11 2M E3F@-BP12 2M
Item output M12 Connector E3F@-LP21 E3F@-LP22 E3F@-VP21 E3F@-BP21 E3F@-BP22
100 mm 200 mm 10 to 50 mm
100 to 500 mm 0.1 to 2 m
Sensing distance (white paper: (white paper: (glass(t = 1.0 mm):
(with E39-RP1) (with E39-RP1)
300  300 mm) 300  300 mm) 150  150 mm)
10  10 mm 10  15 mm 10  10 mm
Spot diameter (reference value) Sensing distance of Sensing distance of Sensing distance of —
100 mm 200 mm 50 mm
Standard sensing object — glass(t = 1.0 mm): 150  150 mm
Differential travel 20% max. —
Directional angle —
Light source (wavelength) Red LED (624 nm)
Power supply voltage 10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
Current consumption 25 mA max.
NPN/PNP (open collector)
Control output
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max.
Operation mode Light-ON/Dark-ON selectable by wiring
Operation indicator (orange)
Indicator
Stability indicator (green)
Protection circuits Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection
Response time 0.5 ms
Sensitivity adjustment Fixed One-turn adjuster
Ambient illumination
Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max.
(Receiver side)
Ambient temperature range Operating: -25 to 55C/ Storage: -30 to 70C (with no icing or condensation)
Ambient humidity range Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y and Z directions
Degree of protection IEC: IP67, DIN 40050-9: IP69K *
Weight E3FA: Approx. 60 g/ Approx. 50 g,
Pre-wired cable (2M)
(packed E3FB: Approx. 95 g/ Approx. 65 g
state/only E3FA: Approx. 20 g/ Approx. 10 g,
sensor) Connector
E3FB: Approx. 50 g/ Approx. 20 g
Case E3FA: ABS, E3FB: Nickel-brass
Lens and Display PMMA
Material
Adjuster POM
Nut E3FA: POM, E3FB: Nickel-brass
Instruction sheet
Accessories
M18 nuts (2 pcs)
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water
is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0, 30, 60, and 90 from
the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.

8
E3FA/E3RA/E3FB/E3RB

Radial type (E3FA/E3FB)


Retro-reflective
Sensing method Through-beam Diffuse-reflective
with MSR function
Model NPN Pre-wired E3R@-TN11 2M E3R@-RN11 2M E3R@-DN11 2M E3R@-DN12 2M E3R@-DN13 2M
output M12 Connector E3R@-TN21 E3R@-RN21 E3R@-DN21 E3R@-DN22 E3R@-DN23
PNP Pre-wired E3R@-TP11 2M E3R@-RP11 2M E3R@-DP11 2M E3R@-DP12 2M E3R@-DP13 2M
Item output M12 Connector E3R@-TP21 E3R@-RP21 E3R@-DP21 E3R@-DP22 E3R@-DP23
100 mm 300 mm 700 mm
0.1 to 3 m
Sensing distance 15 m (white paper: (white paper: (white paper:
(with E39-R1S)
300  300 mm) 300  300 mm) 300  300 mm)
35  40 mm 40  45 mm 90  120 mm
Spot diameter (reference value) — Sensing distance Sensing distance Sensing distance
of 100 mm of 300 mm of 700 mm
Opaque: Opaque:
Standard sensing object —
7 mm dia.min. 75 mm dia.min.
Differential travel — 20% max.
Directional angle 2 min. —
Light source (wavelength) Red LED (624 nm)
Power supply voltage 10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
40mA max.
(Emitter 25 mA
Current consumption 25 mA max.
max. Receiver 15
mA max.)
NPN/PNP (open collector)
Control output
Load current: 100 mA max. (Residual voltage: 2 V max.), Load power supply voltage: 30 VDC max.
Operation mode Light-ON/Dark-ON selectable by wiring
Operation indicator (orange)
Indicator Stability indicator (green)
Power indicator (green): only Emitter of Through-beam
Protection circuits Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection
Response time 0.5 ms
Sensitivity adjustment One-turn adjuster
Ambient illumination
Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max.
(Receiver side)
Ambient temperature range Operating: -25 to 55C/ Storage: -30 to 70C (with no icing or condensation)
Ambient humidity range Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y and Z directions
Degree of protection IEC: IP67, DIN 40050-9: IP69K *
E3RA:
Approx. 110 g/
Approx. 50 g,
respectively, E3RA: Approx. 60 g/ Approx. 50 g,
Pre-wired cable (2M)
E3RB: E3RB: Approx. 95 g/ Approx. 65 g
Approx. 175 g/
Weight Approx. 65 g,
(packed respectively
state/only E3RA:
sensor) Approx. 30 g/
Approx. 10 g,
respectively, E3RA: Approx. 20 g/ Approx. 10 g,
Connector
E3RB: E3RB: Approx. 50 g/ Approx. 20 g
Approx. 85 g/
Approx. 20 g,
respectively
Case E3RA: ABS, E3RB: Nickel-brass
Lens and Display PMMA
Material
Adjuster POM
Nut E3RA: POM, E3RB: Nickel-brass
Instruction sheet Instruction sheet
Accessories
M18 nuts (4 pcs) M18 nuts (2 pcs)
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water
is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0, 30, 60, and 90 from
the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.

9
E3FA/E3RA/E3FB/E3RB
Engineering Data (Reference Value)
Parallel Operating Range
Through-beam Models Retro-reflective Models (with MSR function)
E3F@-T@, E3R@-T@ E3F@-R@1, E3R@-R@1 E3F@-R@2
1000 200 40
Distance Y (mm)

Distance Y (mm)

Distance Y (mm)
E3F@-T@@1 Reflector: E39-R1S Reflector: E39-R1S
800 Y Y
150 30
E3F@-R@@1
600
X X
100 20
400

200 50 E3R@-R@@1 10
Y
0 E3FA-T@@2 0 0
X
−200
−50 −10
−400 E3R@-T@@1
−100 −20
−600
−150 −30
−800

−1000 −200 −40


0 5 10 15 20 25 30 35 40 0 2 4 6 8 0 0.5 1 1.5
Distance X (m) Distance X (m) Distance X (m)

Transparent detected with P-opaquing function


E3F@-B@1 E3F@-B@2
40 150
Distance Y (mm)

Distance Y (mm)

Reflector: E39-RP1 Reflector: E39-RP1


30
100

20
50
10

Y Y
0 0

X X
−10
−50
−20

−100
−30

−40 −150
0 200 400 600 800 1000 1200 0 500 1000 1500 2000 2500 3000 3500 4000 4500
Distance X (mm) Distance X (mm)

Operating Range
Diffuse-reflective Models
E3F@-D@1, E3F@-D@2 E3F@-D@3, E3R@-D@3 E3FA-D@4, E3FA-D@5
E3R@-D@1, E3R@-D@2
30 100 100
Distance Y (mm)

Distance Y (mm)

Distance Y (mm)

Sensing object: white paper Sensing object: 300 × 300 (mm) white paper Sensing object: white paper
80 80
20 E3F@-D@@1
60 60
E3R@-D@@1
E3FA-D@@4
E3F@-D@@2 40 E3R@-D@@3 40 E3FA-D@@5
10 E3R@-D@@2
20 20

0 0 E3F@-D@@3 0

−20 −20
−10
−40 −40

Y −60 Y −60 Y
−20
−80 −80
X X X
−30 −100 −100
0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 1400 1600 1800 0 100 200 300 400 500 600 700
Distance X (mm) Distance X (mm) Distance X (mm)

BGS Models Limited distance reflective


E3FA-D@6 E3F@-L@1, E3F@-L@2 E3F@-V@
Distance Z (mm)

100 40 10
Distance Y (mm)

Distance Y (mm)

Sensing object: 300 × 300 (mm) white paper Sensing object: white paper Sensing object: glass (t=1.0 mm)
80 8
30
60 6
20
40 4
E3F@-L@2
20 10 2

0 0 0

−20 −2
−10
E3F@-L@1
−40 −4
−20
−60 Y Z −6 Y
−30
−80 −8
X X X
−100 −40 −10
0 200 400 600 800 1000 1200 1400 1600 0 50 100 150 200 250 0 20 40 60
Distance X (mm) Distance X (mm) Distance X (mm)

10
E3FA/E3RA/E3FB/E3RB

Excess Gain vs. Distance


Through-beam Models Retro-reflective Models (with MSR function)
E3F@-T@, E3R@-T@ E3F@-R@1, E3R@-R@1 E3F@-R@2
Excess gain ratio (multiple)

Excess gain ratio (multiple)

Excess gain ratio (multiple)


100 100 100
70 70 Reflector: E39-R1S 70 Reflector: E39-R1S
50 50 50
30 30 30

10 10 10
7 7 7
5 5 E3F@-R@@1 5
3 3 3
E3F@-T@@1
E3R@-R@@1
Operating 1 Operating 1 Operating 1
level level level
0.7 E3FA-T@@2 0.7 0.7
0.5 0.5 0.5
0.3 0.3 0.3
E3R@-T@@1

0.1 0.1 0.1


0 10 20 30 40 50 60 70 0 2 4 6 8 10 0 0.5 1 1.5 2
Distance (m) Distance (m) Distance (m)

Diffuse-reflective Models
E3F@-D@1, E3F@-D@2 E3F@-D@3, E3R@-D@3 E3FA-D@4, E3FA-D@5
E3R@-D@1, E3R@-D@2
Excess gain ratio (multiple)

Excess gain ratio (multiple)

Excess gain ratio (multiple)


100 100 100
70 Sensing object: 100 × 100 (mm) white paper 70 Sensing object: 300 × 300 (mm) white paper 70 Sensing object: 300 × 300 (mm) white paper
50 50 50
30 30 30

10 10 10
7 7 7
5 5 5
3 E3F@-D@@2 3 3
E3R@-D@@2 E3FA-D@@5
E3F@-D@@3

Operating 1 E3F@-D@@1 Operating 1 Operating 1


level level level E3FA-D@@4
0.7 E3R@-D@@1 0.7 E3R@-D@@3 0.7
0.5 0.5 0.5
0.3 0.3 0.3

0.1 0.1 0.1


0 200 400 600 800 1000 0 0.5 1 1.5 2 2.5 3 0 200 400 600 800 1000
Distance (mm) Distance (m) Distance (mm)

Transparent detected with P-opaquing function Limited distance reflective


E3FA-D@6 E3F@-B@1, E3F@-B@2 E3F@-V@
Excess gain ratio (multiple)

Excess gain ratio (multiple)

Excess gain ratio (multiple)

100 100 100


70 Sensing object: 300 × 300 (mm) white paper 70 Reflector: E39-RP1 70 Sensing object: glass (t=1.0 mm)
50 50 50
30 30 30

10 10 10
7 7 7
5 5 5
3 3 E3F@-B@2 3

Operating 1 Operating 1 Operating 1


level level level
0.7 0.7 0.7
0.5 0.5 0.5
0.3 0.3 E3F@-B@1 0.3

0.1 0.1 0.1


0 0.5 1 1.5 2 2.5 3 0 1 2 3 4 0 10 20 30 40 50 60 70
Distance (m) Distance (m) Distance (mm)

Sensing Object Size vs. Distance


Diffuse-reflective Models
E3F@-D@1, E3F@-D@2 E3F@-D@3, E3R@-D@3
E3R@-D@1, E3R@-D@2
Distance (mm)

Distance (mm)

700 2000
Sensing object: White paper Sensing object: White paper
1800
600
1600
E3F@-D@@2 E3F@-D@@3
500 E3R@-D@@2 1400

1200
400
d E3R@-D@@3
1000
300 d
800
E3F@-D@@1
200 E3R@-D@@1 600

400
d
100
200
d
0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300 350 400 450 500
Length d of sensing object (mm) Length d of sensing object (mm)

11
E3FA/E3RA/E3FB/E3RB

E3FA-D@4, E3FA-D@5 E3FA-D@6


Distance (mm)

Distance (mm)
1000 1600
Sensing object: White paper Sensing object: White paper
900
1400
800
d 1200
700
d 1000
600

500 800
E3FA-D@5
400 d
600
300 d
E3FA-D@4 400
200
200
100

0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Length d of sensing object (mm) Length d of sensing object (mm)

Sensing Distance vs. Sensing Object Material


BGS Models
E3F@-L@1 E3F@-L@2
Sensing distance (mm)

Sensing distance (mm)

120 250

100
200

80
150

60

100
40

50
20

0 0
White paper Black paper SUS White paper Black paper SUS
Material Material

Dark Excess Gain vs. Sensing Object Characteristics


Transparent detected with P-opaquing function
E3F@-B@1 E3F@-B@2
Relative amount of light received

Relative amount of light received

2.5 2.5

250 mm
2.0 2.0 1m
500 mm 2m

1.5 1.5

1.0 1.0
Operating Operating
level level

0.5 0.5

0.0 0.0
No sensing Empty Filled with Empty Filled with No sensing Empty Filled with Empty Filled with
object water water object water water
Round, 500-ml Square,500-ml Round, 500-ml Square,500-ml
PET bottle PET bottle PET bottle PET bottle

Object Surface Color vs. Sensing Distance


Diffuse-reflective Models
E3FA-D@4 E3FA-D@5 E3FA-D@6
Sensing distance (mm)

Sensing distance (mm)

Sensing distance (mm)

180 700 1600

160 1400
600
140
1200
500
120
1000
100 400
800
80 300
600
60
200
400
40
100 200
20

0 0 0
White Red Green Blue Black White Red Green Blue Black White Red Green Blue Black
paper paper paper paper paper paper paper paper paper paper paper paper paper paper paper

12
E3FA/E3RA/E3FB/E3RB
Output circuit diagram
PNP Output
Operation Operation
Model Timing charts Output circuit
mode selector
Light incident Through-beam Receivers, Retro-reflective Models,
Light interrupted
Operation indicator ON Diffuse-reflective Models, Limited reflective Models.
(orange) OFF Connect the Transparent detected with P-opaquing function.
Output transistor
ON pink wire
Light-ON OFF Brown 10 to 30 VDC
Load Operate
(Pin(2)) to the Operation Stability 1
(e.g., relay) Reset brown (Pin(1)) indicator indicator
(Between blue (Orange) (Green) Light-ON
100 mA max.
and black leads) Black
Photo-
(Control output)
4
electric
Sensor Load
E3F@-TP@ Light incident
Connect the Main Blue (Relay)
Light interrupted Circuit
E3F@-RP@ Operation indicator ON pink wire
3
0V
Dark-ON
E3F@-DP@ (orange) OFF
(Pin(2)) to the Pink
ON 2
E3F@-VP@ Dark-ON Output transistor
OFF blue (Pin(3))
E3F@-BP@ Load Operate or open the
(e.g., relay) Reset
E3R@-TP@ (Between blue pink wire
E3R@-RP@ and black leads)
(Pin(2))
E3R@-DP@
Through-beam Emitter
Power Brown
1
indicator
(green)
Photo-
electric 10 to 30 VDC
Sensor
Main
Circuit Blue
3

NEAR FAR Background suppression.


Operation indicator ON
(orange) OFF Connect the
ON
Output transistor pink wire
Light-ON OFF
Brown 10 to 30 VDC
Load Operate (Pin(2)) to the Operation Stability 1
(e.g., relay) Reset brown (Pin(1)) indicator indicator
(Between blue (Orange) (Green) Light-ON
and black leads) 100 mA max.
Black (Control output)
Photo- 4
E3F@-LP@ electric
Sensor Load
NEAR FAR
Connect the Main
Circuit
Blue (Relay)
Operation indicator ON 3
(oramge) OFF pink wire 0V
Dark-ON
Output transistor ON (Pin(2)) to the 2
Pink
Dark-ON OFF
blue (Pin(3))
Load Operate
(e.g., relay) Reset or open the
(Between blue
and black leads)
pink wire
(Pin(2))

13
E3FA/E3RA/E3FB/E3RB

NPN Output
Operation Operation
Model Timing charts Output circuit
mode selector
Light incident
Connect the Through-beam Receivers, Retro-reflective Models,
Light interrupted
Operation indicator ON pink wire Diffuse-reflective Models, Limited reflective Models.
(orange) OFF
ON
(Pin(2)) to the Transparent detected with P-opaquing function.
Output transistor
Light-ON OFF brown (Pin(1)) Brown 10 to 30 VDC
Operation Stability 1
Load Operate or open the indicator indicator Light-ON
(e.g., relay) Reset
(Between brown pink wire (Orange) (Green) Load
(Relay)
and black leads)
(Pin(2)) Photo- 4
Black
100 mA max.
electric
Sensor (Control output)
E3F@-TN@ Light incident
Main Blue
Light interrupted Circuit
E3F@-RN@ Operation indicator ON
3
0V
E3F@-DN@ (orange) OFF Connect the Pink
Dark-ON

E3F@-VN@ Output transistor


ON pink wire 2
Dark-ON OFF
E3F@-BN@ Load Operate
(Pin(2)) to the
E3R@-TN@ (e.g., relay) Reset blue (Pin(3))
(Between brown
E3R@-RN@ and black leads)
E3R@-DN@
Through-beam Emitter
Power Brown
1
indicator
(green)
Photo-
electric 10 to 30 VDC
Sensor
Main
Circuit Blue
3

NEAR FAR
Connect the Background suppression.
Operation indicator ON
(orange) OFF
pink wire
ON (Pin(2)) to the
Output transistor
Light-ON OFF brown (Pin(1)) Brown 10 to 30 VDC
Load Operate Operation Stability 1
(e.g., relay) Reset
or open the indicator indicator Light-ON
(Between brown pink wire (Orange) (Green) Load
(Relay)
and black leads)
(Pin(2)) Photo- 4
Black
100 mA max.
E3F@-LN@ electric
Sensor (Control output)
NEAR FAR
Main Blue
Operation indicator ON Circuit 3
(oramge) 0V
OFF
Connect the Pink
Dark-ON
ON
Output transistor pink wire 2
Dark-ON OFF
Load Operate (Pin(2)) to the
(e.g., relay) Reset
(Between brown blue (Pin(3))
and black leads)

Connector Pin Arrangement Connectors (Sensor I/O connectors)


M12 Connector Pin Arrangement M12 4-wire Connectors

1 Pin No.
2 4 Wire color
3 2 1 Brown
2 White
1 3 3 Blue
4 4 Black

Classification Wire color Connector pin No. Application


Brown ➀ Power supply (+V)
White ➁ L/on · D/on selectable
DC
Blue ➂ Power supply (0 V)
Black ➃ Output

14
E3FA/E3RA/E3FB/E3RB
Nomenclature
Straight type, Plastic housing Radial type, Plastic housing
with an adjuster: with an adjuster:
E3FA-T@-D E3RA-T@-D
E3FA-R@ E3RA-R@
E3FA-D@ E3RA-D@
E3FA-V@ without an adjuster:
E3FA-B@ E3RA-T@-L *
without an adjuster:
E3FA-T@-L *
E3FA-L@ Sensitivity adjuster Sensitivity adjuster

Stability indicator Operation indicator Stability indicator Operation indicator


(Green) (Orange) (Green) (Orange)

* The Emitter has two Power indicators (Green) instead of the Stability indicator (Green) and the Operation indicator (Orange).

Straight type, Metal housing Radial type, Metal housing


with an adjuster: with an adjuster:
E3FB-T@-D E3RB-T@-D
E3FB-R@ E3RB-R@
E3FB-D@ E3RB-D@
E3FB-V@ without an adjuster:
E3FB-B@ E3RB-T@-L *
without an adjuster:
E3FB-T@-L * Sensitivity adjuster
Sensitivity adjuster
E3FB-L@
Stability indicator Operation indicator Stability indicator Operation indicator
(Green) (Orange) (Green) (Orange)

* The Emitter has two Power indicators (Green) instead of the Stability indicator (Green) and the Operation indicator (Orange).

Safety Precautions
Refer to Warranty and Limitations of Liability.
5. Do not use the sensor under the environment under the other
WARNING conditions in excess of rated.
This product is not designed or rated for directly or 6. Do not use the sensor in place that is exposed by direct sunlight.
indirectly ensuring safety of persons. Do not use it 7. Do not use the sensor in place where the sensor may receive
for such a purpose. direct vibration or shock.
8. Do not use the thinner, alcohol, or other organic solvents.
9. Never disassemble, repair nor tamper with the sensor.
10.Please process it as industrial waste.
CAUTION
Never use the product with an AC power supply.
Precautions for Correct Use
Do not use the product with voltage in excess of the
rated voltage. 1. Laying Sensor wiring in the same conduit or duct as high-voltage
wires or power lines may result in malfunction or damage due to
conduit or use shielded cable.
Do not use the product with incorrect wiring. 2. Do not pull on the cable with excessive force.
Otherwise, explosion, fire, malfunction may result. 3. If a commercial switching regulator is used, ground the FG (frame
ground) terminal.
4. The sensor will be available 100 ms after the power supply is tuned
ON. Start to use the sensor 100 ms or more after turning ON the
Precautions for Safe Use power supply. If the load and the sensor are connected to separate
power supplies, be sure to turn ON the sensor first.
Be sure to follow the safety precautions below for added safety. 5. Output pulses may be generated even when the power supply is
OFF. Therefore, it is recommended to first turn OFF the power
1. Do not use the sensor under the environment with explosive, supply for the load or the load line.
flammable or corrosive gas. 6. The sensor must be mounted using the provided nuts. The proper
2. Do not use the sensor under the oil or chemical environment. tightening torque range of E3FA/E3RA plastic housing series is
3. Do not use the sensor in the water, rain or outdoors. between 0.4 and 0.5 N°m. The proper tightening torque of E3FB/
4. Do not use the sensor in the environment where humidity is high E3RB metal housing series is 20 N°m max..
and condensation may occur.

15
E3FA/E3RA/E3FB/E3RB
(Unit: mm)
Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.

Sensors (E3FA/E3RA Plastic housing)


E3FA series Front view
Sensitivity adjuster *
Pre-wired Models 41
Left side view Left side view 34.5 Operation indicator (orange) Mounting Holes
E3FA-T@1@ 2 7 dia.
Stability indicator (green)
E3FA-R@1@ 15 15 Receiver M18 × 30.5 P=1 18.5+0.5
0 dia.

E3FA-D@1@
E3FA-L@1@ 7 16.6 dia.
E3FA-V@11
Emitter
E3FA-B@1@ 23
Vinyl insulated round cable 4 dia. 4 cores
Optical axis Optical axis (conductor cross sectional area:0.128 mm2 (AWG26)
30.5 /insulation outside diameter:0.85 dia.)
Suitable models Suitable models * Suitable models standard length 2 m
E3FA-T@1@ E3FA-R@11 E3FA-T@1@-D
E3FA-R@12 E3FA-D@1@ E3FA-R@12
E3FA-B@11 E3FA-L@1@ E3FA-D@1@
E3FA-V@11 E3FA-V@11
E3FA-B@12 E3FA-B@12

E3FA series Front view Right side view


Sensitivity adjuster *
M12 Connector Models 45
Left side view Left side view 34.5 Operation indicator (orange) Mounting Holes
E3FA-T@2@ 2 7 dia.
Stability indicator (green)
E3FA-R@2@ 15 15 Receiver M18 × 30.5 P=1 18.5+0.5
0 dia.
2 1
E3FA-D@2@
E3FA-L@2@ 7 16.6 dia.
E3FA-V@21
E3FA-B@2@ Emitter M12 × 4 P=1 3 4
23
Optical axis Optical axis
30.5

Suitable models Suitable models * Suitable models


Terminal No. Specification
E3FA-T@2@ E3FA-R@21 E3FA-T@2@-D
1 +V
E3FA-R@22 E3FA-D@2@ E3FA-R@22
2 L/on · D/on selectable
E3FA-B@21 E3FA-L@2@ E3FA-D@2@
E3FA-V@21 E3FA-V@21 3 0V
E3FA-B@22 E3FA-B@22 4 Output

E3RA series Rear view Rear view Front view


Pre-wired Models Optical axis Receiver Optical axis 14.1 dia. M18 × 30.5 P=1
7
E3RA-T@11 Emitter
5.2 5.2
E3RA-R@11
14.9
E3RA-D@1@
Mounting Holes
35.9
43.4
47.4
53.9 18.5+0.5
0 dia.

7 dia.

Stability
indicator (green) Sensitivity adjuster
Operation indicator (orange)
Vinyl insulated round cable 4 dia. 4 cores
(conductor cross sectional area:0.128 mm2 (AWG26)
Suitable models Suitable models /insulation outside diameter:0.85 dia.)
E3RA-T@11 E3RA-R@11 standard length 2 m
E3RA-D@1@

E3RA series Rear view Rear view Front view


M12 Connector Models Optical axis Receiver Optical axis 14.1 dia. M18 × 30.5 P=1
7
E3RA-T@21 Emitter
5.2 5.2
E3RA-R@21
14.9
E3RA-D@2@
35.9
Mounting Holes
43.4
47.4
18.5+0.5
0 dia.
57.9

7 dia.

Stability
indicator (green)
Sensitivity adjuster
M12 × 4 P=1
Operation indicator (orange)
Bottom view
Suitable models Suitable models
E3RA-T@21 E3RA-R@21 Terminal No. Specification
3 2
E3RA-D@2@ 1 +V
2 L/on · D/on selectable
3 0V
4 1 4 Output

16
E3FA/E3RA/E3FB/E3RB

Sensors (E3FB/E3RB Metal housing)


E3FB series Front view
Sensitivity adjuster *
Pre-wired Models 44

E3FB-T@11 Left side view Left side view 37.5 Operation indicator (orange) Mounting Holes
7 dia.
Stability indicator (green)
E3FB-R@1@ Receiver M18 × 26.4 P=1 18.5+0.5
0 dia.

E3FB-D@1@
E3FB-L@1@ 7
E3FB-V@11
Emitter
E3FB-B@1@ 23
Vinyl insulated round cable 4 dia. 4 cores
Optical axis Optical axis (conductor cross sectional area:0.128 mm2 (AWG26)
29.9 /insulation outside diameter:0.85 dia.)
Suitable models Suitable models * Suitable models standard length 2 m
E3FB-T@11 E3FB-R@11 E3FB-T@11-D
E3FB-R@12 E3FB-D@1@ E3FB-R@12
E3FB-B@11 E3FB-L@1@ E3FB-D@1@
E3FB-V@11 E3FB-V@11
E3FB-B@12 E3FB-B@12

E3FB series Front view Right side view


Sensitivity adjuster *
M12 Connector Models 48
Left side view Left side view 37.5 Operation indicator (orange) Mounting Holes
E3FB-T@21 7 dia.
Stability indicator (green)
E3FB-R@2@ Receiver M18 × 26.4 P=1 18.5+0.5
0 dia.

2 1
E3FB-D@2@
E3FB-L@2@ 7
E3FB-V@21
E3FB-B@2@ Emitter M12 × 4 P=1 3 4
23
Optical axis Optical axis
29.9

Suitable models Suitable models * Suitable models Terminal No. Specification


E3FB-T@21 E3FB-R@21 E3FB-T@21-D
1 +V
E3FB-R@22 E3FB-D@2@ E3FB-R@22
2 L/on · D/on selectable
E3FB-B@21 E3FB-L@2@ E3FB-D@2@
E3FB-V@21 E3FB-V@21 3 0V
E3FB-B@22 E3FB-B@22 4 Output

E3RB series Rear view Rear view Front view


Pre-wired Models
E3RB-T@11 Optical axis Receiver
7
Optical axis 14.1 dia. M18 × 26.4 P=1
Emitter
E3RB-R@11 5.2 5.2
E3RB-D@1@ 13
Mounting Holes
35.9
42.8
50.4 56.9 18.5+0.5
0 dia.

7 dia.

Stability
indicator (green)
Sensitivity adjuster
Operation indicator (orange)
Suitable models Suitable models Vinyl insulated round cable 4 dia. 4 cores
E3RB-T@11 E3RB-R@11 (conductor cross sectional area:0.128 mm2 (AWG26)
/insulation outside diameter:0.85 dia.)
E3RB-D@1@ standard length 2 m

E3RB series Rear view Rear view Front view


M12 Connector Models Optical axis Receiver Optical axis 14.1 dia. M18 × 26.4 P=1
7 Emitter
E3RB-T@21
5.2 5.2
E3RB-R@21 13
E3RB-D@2@
35.9 Mounting Holes
42.8
50.4 18.5+0.5
0 dia.

60.9

7 dia.

Stability
indicator (green)

M12 × 4 P=1 Sensitivity adjuster


Operation indicator (orange)
Suitable models Suitable models Bottom view
E3RB-T@21 E3RB-R@21 3 2 Terminal No. Specification
E3RB-D@2@ 1 +V
2 L/on · D/on selectable
3 0V
4 1 4 Output

17
E3FA/E3RA/E3FB/E3RB

Attached nut
4
24 dia.

Three, 24

Material:POM(for E3FA/E3RA)
M18 4 P=1 Nickel-brass(for E3FB/E3RB)

Accessories (Order Separately)


Reflectors
E39-R1S E39-RP1
8.5
44
40.3 3
Two, 3.5 dia. 34
7.5
7
0.2

59.9 52 80 72 63.6

Reflector

1.6 2.7
Two, 3.5 dia.

Mounting brackets Mounting brackets


E39-L183 E39-L182

42
4.3
Two, R15

22
Two, 30°
37 Two, 4.3
14.5 12.5

15

1.5
(R16.5) 27 dia.
90°
18.2 dia. 15.1

16.7 dia.
36.5

20

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

18
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
part of all quotes, agreements, purchase orders, acknowledgments, price lists, BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
catalogs, manuals, brochures and other documents, whether electronic or in PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
writing, relating to the sale of products or services (collectively, the "Products") INTENDED USE. Omron further disclaims all warranties and responsibility of
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron any type for claims or expenses based on infringement by the Products or oth-
objects to any terms or conditions proposed in Buyer’s purchase order or other erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-
documents which are inconsistent with, or in addition to, these Terms. gation hereunder shall be, at Omron’s election, to (i) replace (in the form
2. Prices; Payment Terms. All prices stated are current, subject to change with- originally shipped with Buyer responsible for labor charges for removal or
out notice by Omron. Omron reserves the right to increase or decrease prices replacement thereof) the non-complying Product, (ii) repair the non-complying
on any unshipped portions of outstanding orders. Payments for Products are Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
due net 30 days unless otherwise stated in the invoice. the non-complying Product; provided that in no event shall Omron be responsi-
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices ble for warranty, repair, indemnity or any other claims or expenses regarding
sent to Buyer after deducting transportation charges, taxes and duties, and will the Products unless Omron’s analysis confirms that the Products were prop-
be allowed only if (i) the invoice is paid according to Omron’s payment terms erly handled, stored, installed and maintained and not subject to contamina-
and (ii) Buyer has no past due amounts. tion, abuse, misuse or inappropriate modification. Return of any Products by
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or Buyer must be approved in writing by Omron before shipment. Omron Compa-
the maximum legal rate, whichever is less, on any balance not paid within the nies shall not be liable for the suitability or unsuitability or the results from the
stated terms. use of Products in combination with any electrical or electronic components,
5. Orders. Omron will accept no order less than $200 net billing. circuits, system assemblies or any other materials or substances or environ-
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all ments. Any advice, recommendations or information given orally or in writing,
costs involved in, obtaining any government approvals required for the impor- are not to be construed as an amendment or addition to the above warranty.
tation or sale of the Products. See http://www.omron247.com or contact your Omron representative for pub-
7. Taxes. All taxes, duties and other governmental charges (other than general lished information.
real property and income taxes), including any interest or penalties thereon, 14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
imposed directly or indirectly on Omron or required to be collected directly or FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
indirectly by Omron for the manufacture, production, sale, delivery, importa- LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
tion, consumption or use of the Products sold hereunder (including customs WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
duties and sales, excise, use, turnover and license taxes) shall be charged to BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
and remitted by Buyer to Omron. Further, in no event shall liability of Omron Companies exceed the individual
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory price of the Product on which liability is asserted.
to Omron, Omron reserves the right to stop shipments or require satisfactory 15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
security or payment in advance. If Buyer fails to make payment or otherwise their employees from and against all liabilities, losses, claims, costs and
comply with these Terms or any related agreement, Omron may (without liabil- expenses (including attorney's fees and expenses) related to any claim, inves-
ity and in addition to other remedies) cancel any unshipped portion of Prod- tigation, litigation or proceeding (whether or not Omron is a party) which arises
ucts sold hereunder and stop any Products in transit until Buyer pays all or is alleged to arise from Buyer's acts or omissions under these Terms or in
amounts, including amounts payable hereunder, whether or not then due, any way with respect to the Products. Without limiting the foregoing, Buyer (at
which are owing to it by Buyer. Buyer shall in any event remain liable for all its own expense) shall indemnify and hold harmless Omron and defend or set-
unpaid accounts. tle any action brought against such Companies to the extent based on a claim
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation that any Product made to Buyer specifications infringed intellectual property
unless Buyer indemnifies Omron against all related costs or expenses. rights of another party.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
resulting from causes beyond its control, including earthquakes, fires, floods, sive property of Omron Companies and Buyer shall not attempt to duplicate it
strikes or other labor disputes, shortage of labor or materials, accidents to in any way without the written permission of Omron. Notwithstanding any
machinery, acts of sabotage, riots, delay in or lack of transportation or the charges to Buyer for engineering or tooling, all engineering and tooling shall
requirements of any government authority. remain the exclusive property of Omron. All information and materials supplied
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: by Omron to Buyer relating to the Products are confidential and proprietary,
a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship and Buyer shall limit distribution thereof to its trusted employees and strictly
except in “break down” situations. prevent disclosure to any third party.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall 17. Export Controls. Buyer shall comply with all applicable laws, regulations and
constitute delivery to Buyer; licenses regarding (i) export of products or information; (iii) sale of products to
c. All sales and shipments of Products shall be FOB shipping point (unless oth- “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
erwise stated in writing by Omron), at which point title and risk of loss shall regulated technology or information.
pass from Omron to Buyer; provided that Omron shall retain a security inter- 18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
est in the Products until the full purchase price is paid; and no course of dealing between Buyer and Omron shall operate as a waiver
d. Delivery and shipping dates are estimates only; and of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
e. Omron will package Products as it deems proper for protection against nor- without Omron's written consent. (c) Law. These Terms are governed by the
mal handling and extra charges apply to special conditions. law of the jurisdiction of the home office of the Omron company from which
12. Claims. Any claim by Buyer against Omron for shortage or damage to the Buyer is purchasing the Products (without regard to conflict of law princi-
Products occurring before delivery to the carrier must be presented in writing ples). (d) Amendment. These Terms constitute the entire agreement between
to Omron within 30 days of receipt of shipment and include the original trans- Buyer and Omron relating to the Products, and no provision may be changed
portation bill signed by the carrier noting that the carrier received the Products or waived unless in writing signed by the parties. (e) Severability. If any provi-
from Omron in the condition claimed. sion hereof is rendered ineffective or invalid, such provision shall not invalidate
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
Products will be free from defects in materials and workmanship for a period of against the amount owing in respect of this invoice. (g) Definitions. As used
twelve months from the date of sale by Omron (or such other period expressed herein, “including” means “including without limitation”; and “Omron Compa-
in writing by Omron). Omron disclaims all other warranties, express or implied. nies” (or similar words) mean Omron Corporation and any direct or indirect
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, subsidiary or affiliate thereof.
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-

Certain Precautions on Specifications and Use


1. Suitability of Use. Omron Companies shall not be responsible for conformity ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-
with any standards, codes or regulations which apply to the combination of the ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
Product in the Buyer’s application or use of the Product. At Buyer’s request, OVERALL EQUIPMENT OR SYSTEM.
Omron will provide applicable third party certification documents identifying 2. Programmable Products. Omron Companies shall not be responsible for the
ratings and limitations of use which apply to the Product. This information by user’s programming of a programmable Product, or any consequence thereof.
itself is not sufficient for a complete determination of the suitability of the Prod- 3. Performance Data. Data presented in Omron Company websites, catalogs
uct in combination with the end product, machine, system, or other application and other materials is provided as a guide for the user in determining suitabil-
or use. Buyer shall be solely responsible for determining appropriateness of ity and does not constitute a warranty. It may represent the result of Omron’s
the particular Product with respect to Buyer’s application, product or system. test conditions, and the user must correlate it to actual application require-
Buyer shall take application responsibility in all cases but the following is a ments. Actual performance is subject to the Omron’s Warranty and Limitations
non-exhaustive list of applications for which particular attention must be given: of Liability.
(i) Outdoor use, uses involving potential chemical contamination or electrical 4. Change in Specifications. Product specifications and accessories may be
interference, or conditions or uses not described in this document. changed at any time based on improvements and other reasons. It is our prac-
(ii) Use in consumer products or any use in significant quantities. tice to change part numbers when published ratings or features are changed,
(iii) Energy control systems, combustion systems, railroad systems, aviation or when significant construction changes are made. However, some specifica-
systems, medical equipment, amusement machines, vehicles, safety equip- tions of the Product may be changed without any notice. When in doubt, spe-
ment, and installations subject to separate industry or government regulations. cial part numbers may be assigned to fix or establish key specifications for
(iv) Systems, machines and equipment that could present a risk to life or prop- your application. Please consult with your Omron’s representative at any time
erty. Please know and observe all prohibitions of use applicable to this Prod- to confirm actual specifications of purchased Product.
uct. 5. Errors and Omissions. Information presented by Omron Companies has been
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS checked and is believed to be accurate; however, no responsibility is assumed
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT for clerical, typographical or proofreading errors or omissions.
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Hoffman Estates, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com

OMRON CANADA, INC. • HEAD OFFICE OMRON ARGENTINA • SALES OFFICE


Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com Cono Sur • 54.11.4783.5300

OMRON ELECTRONICS DE MEXICO • HEAD OFFICE OMRON CHILE • SALES OFFICE


México DF • 52.55.59.01.43.00 • 01-800-226-6766 • [email protected] Santiago • 56.9.9917.3920

OMRON ELECTRONICS DE MEXICO • SALES OFFICE OTHER OMRON LATIN AMERICA SALES
Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • [email protected] 54.11.4783.5300

OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE


São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br

OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu

Authorized Distributor: Automation Control Systems


• Machine Automation Controllers (MAC) • Programmable Controllers (PLC)
• Operator interfaces (HMI) • Distributed I/O • Software
Drives & Motion Controls
• Servo & AC Drives • Motion Controllers & Encoders
Temperature & Process Controllers
• Single and Multi-loop Controllers
Sensors & Vision
• Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors
• Amplified Photomicrosensors • Measurement Sensors
• Ultrasonic Sensors • Vision Sensors
Industrial Components
• RFID/Code Readers • Relays • Pushbuttons & Indicators
• Limit and Basic Switches • Timers • Counters • Metering Devices
• Power Supplies
Safety
• Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety
Controllers • Light Curtains • Safety Relays • Safety Interlock Switches

$BU/P&*&  Note: Specifications are subject to change. © 2014 Omron Electronics LLC Printed in U.S.A.

Printed on recycled paper.