Old Model P-500-1: General

The document provides specifications for a P-510 purgemeter model for measuring medium and large flow rates of liquids and gases. It has an aluminum or stainless steel body and measures flow rates from 2.5-600 NL/min for air or 0.1-30 L/min for water, with an accuracy of 5% of the full scale. It has a maximum operating pressure of 0.78MPaG and temperature of 120°C.

Uploaded by

Irsan Tasman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views2 pages

Old Model P-500-1: General

The document provides specifications for a P-510 purgemeter model for measuring medium and large flow rates of liquids and gases. It has an aluminum or stainless steel body and measures flow rates from 2.5-600 NL/min for air or 0.1-30 L/min for water, with an accuracy of 5% of the full scale. It has a maximum operating pressure of 0.78MPaG and temperature of 120°C.

Uploaded by

Irsan Tasman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

P-510 Old model P-500-1

GENERAL
Purgemeter for medium and large flow rate. Aluminum body avail-
able in addition to standard Stainless-steel body. It is the same
size as P-200 model of small flow rate type.

MAJOR APPLICATIONS
General purpose(Large flow rate)

STANDARD SPECIFICATION
Measuring object Liquids and gases
. Air at 0oC, 1atm
Min. 2.5~25 NL/min. . When selecting flow
Air
Max. 60~600 NL/min. range, refer to standard
Measuring flow rate table.
range . In case Op. Press. at gas
Min. 0.1~1 L/min.
Water is not 1atm, refer to page
Max. 3~30 L/min.
1.
Range ability 10:1
Accuracy 5%F.S.
Max. Op. Press. 8kgf/ cm2G(0.78MPaG)
Standard products have the
Max. Op. Temp. 120oC packing materials made of
NBR, so Max. Temp.is 80oC.
Option(Specify by model
Material Std.
code)
Body SUS304 SUS316, Aluminum BASIC MODEL CODE

VALVE

ALARM ANALOG OUTPUT

WETTED PARTS MATERIAL

PACKING MATERIAL

CONNECTION TYPE

CONNECTION SIZE
Refer to P-7 series for SERIES NAME
Tapered tube Pyrex glass fluorine resin made tapered

FLOW DIRECTION
tube. EXAMPLE
Viton(max.120oC),
Packing NBR(max80 C) o
CR(max.80oC),
EPDM(max.80oC)
Support SPCC or BS DESCRIPTION
Cover Acryl P-51 0 -L 0 -4 N -R 3
Std. Rc3/8
VALVE

ALARM ANALOG OUTPUT

WETTED PARTS MATERIAL

PACKING MATERIAL

CONNECTION TYPE
SIZE
CONNECTION
Refer to Basic model code
Connection Rc1/2,NPT3/8,NPT1/2,3/8SW,
Opt. for details.
3/8VCR,JIS10KFF etc.
Thread(M3)mount onto panel front 3
Std. 3/8(Standard)
Mounting Lock-nut mount onto panel front Refer to ordering information
4 1/2 Connection type code R,N,S can not be selected.
Bezel installation,Panel-rear installation, for details.
Opt. 5 3/4 Connection type code L only can be selected.
Stand provided Flange pipe tube installation
6 1 Flow direction code 1 (bottom top) only can be selected
Weight(std. type) 2.0kg
Z Special Select 3,4,5,6,Z for flange
R Rc thread Front thread(M3)of panel, mounting or pipe mounting
N NPT thread Same as above
ALARM AND ANALOG OUTPUT
Type Availability Reference pages Rc thread Lock-nut mounting Bezel installation can
L
General 45, 46 page onto panel front.
Reed switch type alarm unit be selected. Refer to
CE, UL Version 45, 46 page
M NPT thread Same as above Mounting Option in
PAU Optical alarm unit 47 page
S SW Same as above page 55 for details.
Optical alarm unit
V VCR Same as above
Analog output unit 49~52 page
Z Special Select Z for flange
N NBR(Standard)
STANDARD FLOW RATE TABLE C CR Select it for ammonia gas.
(In case Op. Press at gas is not 1atm, refer to page 1.)
F VITON
In case alarm analog output code is O,E and F In case alarm analog output code is A to D E EPDM
AIR(1atm,0oC) Water AIR(1atm,0oC) Alarm setting range Water Alarm setting range Z Special
2.5~ 25 NL/min 4 SUS304(Standard)
0.1~1 L/min Select P-520 model for PVC and
3 ~ 30 NL/min 6 SUS316
5 ~ 50 NL/min 0.2~2 L/min 5~50 NL/min* 10~40 NL/min PTFE. Select P-7 series for
0.3~3 L/min 0.6~2.4 L/min A Aluminium(For Gas) fluorine resin made tapered tube.
10~100 NL/min 0.3~3 L/min 10~100 NL/min 20~80 NL/min Z Special
20~200 NL/min 0.5~5 L/min 20~200 NL/min 40~160 NL/min 0.5~5 L/min 1~4 L/min 0 Not provided
30~300 NL/min 1~10 L/min 30~300 NL/min 60~240 NL/min 1~10 L/min 2~8 L/min A Reed switch alarm (LO)
40~400 NL/min 1.5~15 L/min 40~400 NL/min 80~320 NL/min 1.5~15 L/min 3~12 L/min B Reed switch alarm (LC) Refer to page 45, 46.
50~500 NL/min 2~20 L/min 50~500 NL/min 100~400 NL/min 2~20 L/min 4~16 L/min C Reed switch alarm (HO)
60~600 NL/min 3~30 L/min 60~600 NL/min 120~480 NL/min 3~30 L/min 6~24 L/min D Reed switch alarm (HC)
*Float material should be PVC E PAU ALARM UNIT provided Refer to page 47.
*2 Available for Viscosity 1.0cP only.
G PAS/IAU analog output unit Refer to page 49.
OTHER AVAILABLE OPTIONS Z Special
0 Not provided
You can specify the following options: L Bottom(gas for atmospheric pressure scale)
Refer to valve location selection guide
Two point alarm, Variable type on the front of alarm contact, reed switch U Top(gas for pressure scale or for negative
(Page 57).
lead wire length, double graduations, special graduations, built-in check pressure on the secondary side)
Z Special
valve type, built-in rubber joint type, built-in joint type, etc. 0 Bottom rear Top rear(Standard) Select this code normally.
(For details, refer to 6 Other Option on page 56). 1 Bottom Top Valve should be installed externally.
9 Special

ORDERING INFORMATION
Basic model code Designation items for detailed specifications

P-51 Fluid name Measuring range Press. Temp. Mounting Option Other Option

(Use model code table for selection) (For specification procedure, refer to page 53)

11
DIMENSIONS

STANDARD TYPE
(P-510-U0-4N-R3 Valve provided at Outlet, panel front
PANEL-FRONT INSTALLATION TYPE
thread (M3) mounting type)
(P-510-U0-4N-L3 , Valve provided at Outlet, panel front lock-
nut fixing)

2- 28

(22.5)
4- 4

200
155

29
(22.5)

PANEL CUT PANEL CUT

BEZEL INSTALLATION TYPE PANEL CUT SIZE


(P-510-L0-4N-R3, Valve provided at Outlet, Bezel installation.)
(Mounting Option code D )
For PANEL-FRONT INSTALLATION TYPE,
Panel cut dimension may differ depending on
connection size and rating. Refer to follow-
ing table.

Connection size Hole dia d Rear dia L


Width(40)

Rc 3/8 28 26

NPT 3/8 28 26

Rc 1/2 32 26

NPT 1/2 32 26

Rc 3/4 38 28

3/8 SW 22 (38)

3/8 VCR 32 (37.5)

1/2 VCR 32 (37.5)

Caution) Use non-magnetize material for panel when ALARM ANALOG


OUTPUT code is A~D.
PANEL CUT

Standard Material In case alarm output code is A to D


Parts name Standard material Available material A Reed switch alarm(LO)
SUS304 Aluminium,SUS316 B Reed switch alarm(LC)
Refer to page 45, 46.
Pyrex glass C Reed switch alarm(HO)
SUS304 D Reed switch alarm(HC)
NBR VITON,CR,EPDM
SUS304 SUS316
SUS304 SUS316 In case alarm output code is E, G
Mounting board SPCC SUS304 E PAU ALARM UNIT provided Refer to page 47.
Cover Acryl G PAS/IAU Analog output unit Refer to page 49.
Parts whose names are described in are in contact with
fluids to be measured.