DATED

UP

Chemical Application Description


A highly effective multi functional all-organic product based on the unique
Cetamine
Boiler water treatment for scale and newly developed combination of film forming amines together with
G818
Packaging:20Kg corrosion prevention dispersion and removal effect management polymer. Generally the
dosage rate ranges from 15-55g/m3 of water

A liquid blend of organic and inorganic corrosion inhibitors and


stabilizers based on phosphonic acid, inorganic inhibitors, zinc, and
Ferrofos Corrosion and scale Inhibitor for copper inhibitor. It is a multipurpose cooling water treatment chemical
8549 designed to prevent corrosion of steel, copper/copper alloys, scale
Packaging:20Kg Open Cooling Water Systems
deposits, and sludge formation in all types of industrial cooling water
systems. It is recommended for the pH range from 7.2 to 7.8.
Dosage is 45 to 60 mg/l in the recirculating cooling water. However, the
dosage also depends on the operational condition of the system.
Ferrocid Effectively controls micro organism build up of bacteria, fungi and algae
8585 Biocide for cooling and process water
in cooling water systems.
Packaging:20Kg systems.
General dosage rates range from 10-100g/m3of water.

Excellent biocide in control and prevention of bacteria, algae and fungi


Biocide for cooling and process water growth in cooling water systems. It can also be used as alternate biocide
Kurita
systems. for mutation resistance. Effective in the control of legionella pneumophila
F-5106
Packaging:20Kg bacteria which causes legionnaires disease ( legionellose). Effective in the
pH range from 6-9
General dosage rates range from 25-100g/m3 of water.

A blended liquid product based on nitrite, poly carboxylic acid, inorganic


Korrodex corrosion inhibitor and copper inhibitor. A blended corrosion inhibitor for
8577 Corrosion Inhibitor for closed chiller water systems containing steel and copper alloys. Korrodex 8577
Packaging:20Kg systems. must not be used together with oxidising microbiocides. Lower organic
biocides are considered safe.
Dosage depends on total hardness and below guide may be applied.
TH 0-300ppm CaCO3 1-10g/L, TH>300ppm CaCO3 5-15g/L

Kuriverter A highly effective biofilm removal and dispersal agent in Reverse Osmosis
Biofilm control agent for membrane
systems. It is non-foaming easy to handle with a quick composition in
lk 110 systems (RO Pre-treatment)
Packaging:20Kg aqueous media.
Dosage is dependant on operational conditions of the systems

An antiscalant with a high dispersing capacity for membrane systems


where deposits caused by high hardness or suspended solids are likely to
occur. It prevents the formation of crystals from water hardness by blocking
crystal growth due to its phosphonic acid combination and the
Vitec® 1141 Reverse Osmosis Antiscalant Pre- polycarbonic component. Vitec® 141 can also used for a wide range of
Packaging:20Kg Treatment applications concerning pH, hardness, the content of suspended solids,
etc. Beyond the stabilization limit, an amorphous precipitate is obtained
which is dispersible and does not form a hard scale on the membrane
surface, so that it can be flushed out with the brine. Applicable for pH
range from 7 to 10.

A liquid product for membrane cleaning based on potassium hydroxide,


complexing agents, anionic and non-ionic detergents. Suitable for
removal of oil, grease, ester, and inorganic deposits. RoClean® 2691 can
RoClean 2691 Reverse Osmosis High pH Membrane be used for cleaning alkaline resistant membranes. The concentration into
Packaging:20Kg Cleaning the cleaning solution and the application temperature is dependant on the
deposits to remove. Attention should be paid to the permitted pH and
temperature values.

RoClean® 2575 Reverse Osmosis Low pH Membrane A liquid, acidic membrane cleaner suitable for removing inorganic deposits
Packaging:20Kg Cleaning and scaling from acid resistant membranes. The concentration and
temperature of RoClean® 2575 is dependant on extent of scaling.
Generally concentration is between 5 and 10 g/l and the treatment
temperature should be between 250C to 500C.