0% found this document useful (0 votes)
131 views6 pages

Technical Specs for Engineers

This document provides technical specifications for a high-pressure multistage centrifugal pump. It includes performance curves, materials of construction, motor and electrical specifications, dimensions, weights and other details. The pump model is Helix FIRST V 616-5/25/E/KS/400-50.

Uploaded by

anis.fuad2501
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
131 views6 pages

Technical Specs for Engineers

This document provides technical specifications for a high-pressure multistage centrifugal pump. It includes performance curves, materials of construction, motor and electrical specifications, dimensions, weights and other details. The pump model is Helix FIRST V 616-5/25/E/KS/400-50.

Uploaded by

anis.fuad2501
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Technical data

Contact
E-mail High-pressure multistage centrifugal pump
Phone Helix FIRST V 616-5/25/E/KS/400-50
Customer Project name Untitled project 2022-10-20 10:03:43.887

Project ID
Contact Installation location
E-mail Customer pos.no
Phone

Date 20.10.2022

Duty chart Requested data


Head - 616 Flow 25,00 US g.p.m.
H /m ∆ p / MPa
Head 107,00 m
120 1,2 Media Water 100 %
111,7 Eff. 62,9% 1,093 Fluid temperature 20,00 °C
100 1
Density 998,20 kg/m³
A1
80 0,8 Kin. viscosity 1,00 cSt
60 0,6 Hydraulic data (Duty point)

0,4 Flow 25,54 US g.p.m.


40
Head 111,65 m
20 0,2 Shaft power P2 2,82 kW
▕◄ Application range ►▏ Hydraulic efficiency 62,53 %
0 0
Shaft power P2 NPSH 0,80 m
P₂ 2,822
/ kW
Product data
2
High-pressure multistage centrifugal pump
1 Helix FIRST V 616-5/25/E/KS/400-50
Max. operating pressure 2,5 MPa
0
62,53 Hydraulic efficiency Inlet pressure max. 10 bar
η /%
Fluid temperature -20 °C ... + 120 °C
40 Max. ambient temperature 50 °C
20 Minimum efficiency index (MEI) ≥ 0.7
Motordata per Motor/Pump
0
Motor efficiency level IE3
0 4 8 12 16 20 25,54 28
24 32 36 40 44Q / US g.p.m. Mains connection 3~ 400 V / 50 Hz
ISO 9906: 2012 3B Dimensions mm Permitted voltage tolerance +-10 %
Max. speed 2900 1/min
H 1250 Rated power P2 4,00 kW
H2 944 Rated current 7,40 A
ØM 196 Power factor 0,87
X 164 Efficiency
50% / 75% / 100% 86,5/88/88,1%
Degree of protection IP55
Insulation class F
Motor protection no
Fitting dimensions
Pipe connection on the suction side DN 32, PN 25
Pipe connection on the pressure side DN 32, PN 25
Materials
Pump housing 5.1301/EN-GJL-250

Impeller 1.4307
Shaft 1.4301
Shaft seal BQ7EGG
Gasket material EPDM
Information for order placements
Weight approx. 62 kg
Item number 4201164

Software version Spaix, Version 4.3.13 - 2021/02/23 (Build 180)


Subject to change Data version 09.10.2022 Pages 1/ 1
Project:
Customer:
Engineer:
Pump Manufacturer:

Technical Data
Submittal Document
Model JP3
Across the Line Start
Jockey Pump Controller

Contents:
Data Sheets
Dimensional Data
Wiring Schematics
Field Connections

Note: The drawings included in this package are for controllers


covered under our standard offering. Actual AS BUILT
drawings may differ from what is shown in this package.
June 2022
Technical Data
Model JP3 Jockey Pump Controller

iPD+ Operator Interface

3 2

4 7

HAND AUTO

5
8

1 - Power on LED 6 - STOP pushbutton


2 - System status LED 7 - Auto start LED
3 - Digital display 8 - Navigation keypad
4 - Hand start LED 9 - ON - OFF pushbutton
5 - START pushbutton

This is a Marketing document. Please consult factory for more information.


June 2022 Manufacturer reserves the right to modify this information without notice 5
0 1 2 3 4 5 6 7 8
PER QUOTE DRAWING No.
Jockey Pump Controller NYC
Dpt of Building
Approved

Across the Line / 3 Phase REV. DESCRIPTION DD/MM/YY


A Model:JP3 8 Sensing line connection changed 25/03/20 Drawing No. A
Dimensions 10
UL logo updated CSA logo removed
Removed Seismic logo optional
14/07/20
18/05/22
JP3-DI500/E

FU1 DS
B B
D

XTR1
IPD
F C

C C
Main Disconnect
G

Y
ON
R

OL1

OFF
HAND G G AUTO
C1

G DS

D B E D

PT1
Underwriters
Laboratories Inc.

DANGER
R R

LISTED
ENCLOSED INDUSTRIAL CONTROL PANEL
No. AC-XXX

Rating
E Label E
Standard Internal Layout
3
8 "[ ] x4

Sensing Line Connection 1/2 " M.NPT


F F

Dimensions*
Maximum Motor Horsepower Enclosure Dimensions Door Dimensions Anchor Dimensions

G 4- " [115] 200-208V


10HP
220-240V
10HP
380-416V
15HP
440-480V
20HP
575-600V
25HP
AXBXC
10"X12"X6- "
DXE
10- "X12- "
FXG
8"X12- "
G
20HP 30HP 40HP 60HP 60HP 16"X16"X7- " 16- "X16- " 14"X16- "

2- " [58]
A
H H

Notes: Drawing for information only.


- Standard NEMA: NEMA 2
Manufacturer reserves the right to modify this drawing without notice.
- Standard Paint: Textured Red RAL 3002.
I - All Dimensions are in Inches [Millimeters] Contact manufacturer for "As Built" drawing. I
- Use Watertight Conduit and Connector Only. *Dimensions may change depending on option required. Consult Factory for exact Projection

- Protect Equipment Against Drilling Chips. dimensions.


- Door Swing Equal to Door Width
0 1 2 3 4 5 6 7 8
Copyright © 2022 Tornatech Inc. All right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech Inc. Copies are communicated to the recipient in strict confidence and may not be retransmitted published reproduced copied or used in any manner including as the basis for the manufacture or sale of any products without the express prior written consent of Tornatech Inc.
0 1 2 3 4 5 6 7 8
PER QUOTE DRAWING No.
Jockey Pump Controller C
Dpt of Building
Approved

Across the Line / 3 Phase REV. DESCRIPTION DD/MM/YY


A Model:JP3 7 Revised logo 18/06/18 Drawing o. A
Wiring schematic 8
9
UL logo updated CSA logo removed
Removed Seismic logo (optional)
14/07/20
18/05/22
JP3-WS500/E

L1 L2 L3 Pressure Sensor
PT1 Type 0.5 - 4.5V
B B
G
DS G

White

Black
Red
R

B W G R 5 S

RESET J5
HA D G G AUT

Ps ut-
PsIn-

Ps ut+
PsIn+
L1
C 34 33 7 C
9 I 1 J9
J21
G
I 2
UTPUT J8

J19
"IPD+"
D D
F5

FU1 J2 J3 J1
TR1
24Vac 24Vac
H2 1 3 A2 A1
3 1 22 8
H1 2
1
E E

A1 A2
C1

F F

G G

H H
L1

C1

I
- Drawing for information only. I
G Manufacturer reserves the right to modify this drawing without notice.
T1 T2 T3
Contact manufacturer for "As Built" drawing.
P1
0 1 2 3 4 5 6 7 8
Copyright © 2022 Tornatech Inc. All right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech Inc. Copies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech Inc.
0 1 2 3 4 5 6 7 8
PER QUOTE DRAWING No.
Jockey Pump Controller NYC
Dpt of Building
Approved

Across the Line / 3 Phase REV. DESCRIPTION DD/MM/YY


A Model:JP3 7 evised logo
L logo updated CSA logo removed
18/06/18 Drawing No. A
Line and Motor Terminal Size 8
emoved Seismic logo optional
14/07/20
18/05/22
JP3-TD500/E

B B

Power Connections and Motor Connections

3 Phase
Incoming Power
Bonding Ground

C C

L1 L2 L3
DS

C1

D T1 T2 T3 D

E E

Line Terminals L1 L2 L3 GND


Ma imum Motor Horsepower
Wire Size Copper nly Tor ue Wire Size Ground Copper nly
200-208V 220-240V 380-416V 440-480V 575-600V
10HP 10HP 20HP 20HP 25HP #14 AWG - #6 AWG 2 Nm #14 AWG - #2 AWG
20HP 30HP 40HP 60HP 60HP #12 AWG - #1 AWG 6 Nm #6 AWG - #2 AWG

G G

Motor Terminals T1 T2 T3 GND


Ma imum Motor Horsepower
Wire Size Copper nly Tor ue Wire Size Ground Copper nly
200-208V 220-240V 380-416V 440-480V 575-600V
5HP 7.5HP 10HP 15HP 20HP #14 AWG - #10 AWG 1.8 Nm #14 AWG - #2 AWG
H 10HP 10HP 15HP 20HP 25HP #14 AWG - #6 AWG 2.5 Nm #12 AWG - #2 AWG H
15HP 20HP 30HP 50HP 50HP #10 AWG - #3 AWG 5 Nm #12 AWG - #2 AWG
20HP 30HP 40HP 60HP 60HP #10 AWG - #2 AWG 11.3 Nm #12 AWG - #2 AWG

I I

0 1 2 3 4 5 6 7 8
Copyright © 2022 Tornatech Inc. All right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech Inc. Copies are communicated to the recipient in strict confidence and may not e retransmitted pu lished reproduced copied or used in any manner including as the asis for the manufacture or sale of any products without the e press prior written consent of Tornatech Inc.