0% found this document useful (0 votes)
34 views32 pages

Environmental Product Declaration: Unilin Insulation Ireland LTD

The document provides an environmental product declaration for insulation products manufactured by Unilin Insulation UK Ltd in Chesterfield, England. It includes information on the program operator, declaration number, production site, declared unit, applicable standards, and scope of the LCA from cradle to gate with some optional modules declared.

Uploaded by

ntoutcheulouis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views32 pages

Environmental Product Declaration: Unilin Insulation Ireland LTD

The document provides an environmental product declaration for insulation products manufactured by Unilin Insulation UK Ltd in Chesterfield, England. It includes information on the program operator, declaration number, production site, declared unit, applicable standards, and scope of the LCA from cradle to gate with some optional modules declared.

Uploaded by

ntoutcheulouis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

ENVIRONMENTAL PRODUCT

DECLARATION
as per ISO 14025 and EN 15804 + A2
Owner of the Declaration – Unilin Insulation Ireland
Limited

Declaration number: EPDIE-21-41


Issue date 3rd November 2021
Valid to 3rd November 2026
Unilin Insulation Ireland Ltd
CT/PIR, FR/ALU, FR/BGM, FR/MG, Thin-R
EPD Programme - EPD Ireland
Programme Operator - Irish Green Building Council
www.epdireland.org
1. General information

PROGRAMME OPERATOR OWNER OF DECLARATION

Unilin Insulation Ireland Ltd


Irish Green Building Council
Kells Road, Navan, Co. Mearh, Ireland C15 NP79
19 Mountjoy Square, Dublin D01 E8P5
T +353 (0) 46 906 6000; [email protected]
[email protected]
www.unilininsulation.ie

DECLARATION NUMBER PRODUCTION SITE

Unilin Insulation UK Ltd


EPDIE-21-41 Park Road, Holmewood, Chesterfield, Derbyshire, United Kingdom, S42 5UY
www.unilininsulation.co.uk

ECO PLATFORM EPD DECLARED UNIT

1m² 100mm CT/PIR R-value 4.75 m²K/W


1m² 100mm FR/ALU R-value 4.5 m²K/W
Yes 1m² 100mm FR/BGM R-value 4.0 m²K/W
1m² 100mm FR/MG R-value 4.0 m²K/W
1m² 100mm Thin-R R-value 4.5 m²K/W

APPLICABLE PRODUCT CATEGORY RULES DECLARED PRODUCT

EN 15804:2012+A2:2019
Unilin Insulation UK Ltd PIR insulation products manufactured in
EPD Ireland PCR Part A, Version 2.0, 2021
Chesterfield, England: CT/PIR 100mm, FR/ALU 100mm, FR/BGM 100mm,
I.S. EN 16783:2017 Thermal insulation products – Product
FR/MG
category rules (PCR) for factory made and in-situ formed
100mm, Thin-R 100mm
products for preparing environmental product declarations

DATE OF ISSUE SCOPE OF EPD

03.11.2021 Cradle-to-gate, with options.


Reissue: This EPD applies to products manufactured in Chesterfield, England, and
09.01.2023 - Changes: owner name and logo from Xtratherm to Unilin Insulation
Ireland Limited and products’ name due to rebranding supplied to customers in Great Britain.

DATE OF EXPIRY LCA CONSULTANT OR PERSON RESPONSIBLE FOR LCA

EcoReview, Kilkenny, Co. Kilkenny, Ireland


03.11.2026 +353 87 258 9783 / +31 646 264 9327
[email protected] / www.ecoreview.eu

TYPE OF EPD: SINGLE OR MULTI PRODUCT LCA SOFTWARE AND DEVELOPER IF APPLICABLE

Multi product EPD Ecochain 3.2.12

PRODUCT CLASSIFICATION OR NACE CODE NAME AND VERSION OF INVENTORY USED

Thermal insulation products Ecoinvent 3.6

COMPARABILITY

Environmental Product Declarations from different programmes may not be directly comparable if not compliant with EN
15804:2012+A2:2019. Comparability is further dependent on the specific product category rules, system boundaries and allocations, and
background data sources. See clause 5.3 of EN 15804:2012+A2:2019

The CEN Norm /EN 15804 serves as the core PCR

Independent verification of the declaration according to ISO 14025

Internally  Externally 

SIGNATURE OF PROGRAMME OPERATOR SIGNATURE VERIFIER

Pat Barry - CEO - Irish Green Building Council Chris Foster - EuGeos SRL
2. Scope and Type of EPD
Scope
This EPD is Cradle-to-gate with options. The Modules that are declared are shown in the table below.

CONSTRUCTION BENEFITS AND LOADS


PRODUCT STAGE ON PROCESS USE STAGE END OF LIFE STAGE BEYOND THE SYSTEM
STAGE BOUNDARIES

Reuse – Recovery – Recycling potential


Transport from the gate to the site

De-construction demolition
Operational energy use

Operational water use


Raw material supply

Waste processing
Refurbishment
Manufacturing

Replacement
Maintenance
Assembly

Transport
Transport

Disposal
Repair
Use

A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D

X X X X X ND ND ND ND ND ND ND X X X X X

MDT MDT MDT OP OP OP OP OP OP OP OP OP MDT MDT MDT MDT MDT

X = Module declared; ND = Module not declared; MDT = Mandatory; OP = Optional.

Declared Units
1m² 100mm CT/PIR R-value 4.75 m²K/W
1m² 100mm FR/ALU R-value 4.5 m²K/W
1m² 100mm FR/BGM R-value 4.0 m²K/W
1m² 100mm FR/MG R-value 4.0 m²K/W
1m² 100mm Thin-R R-value 4.5 m²K/W

System Boundaries
3. Detailed product description
This EPD is for the (Polyisocyanurate) PIR insulation boards: CT/PIR, FR/ALU, FR/BGM, FR/MG, Thin-R, of thickness
100mm, the R values quoted are minimum values and the EPD is calculated on this basis. The PIR boards
typically comprise of primary raw materials MDI, polyol, flame retardant, pentane, with the addition of minor
amounts of admixtures. Depending on intended use, the board facing elements comprise various combinations
of the following materials: paper, foil, hard plastic, mineral glass, bitumen fibre. The primary raw materials are
mixed with various catalysts & additives and placed between two layers of facing elements. The insulation
products are manufactured in accordance with BS EN 13165:2012+A2:2016 Thermal insulation products for
buildings.

These insulation products are used in cavity walls, steel and timber-frame walls, soffit, floor, pitched and flat roof
insulation applications.

3.1 Manufacturing Process Description


The main raw materials are mixed with various catalysts and additives before being metered onto a moving
conveyor. The chemical mix then starts to rise, due to the effects of the blowing agent, to produce the foam. The
foam continues to rise until it contacts the top layer of facer material as it enters the oven, where it is then cured
under heat to produce the rigid, thermoset foam board. The board exits the lamination oven and then reaches
a cross-cut saw which cuts the board into smaller mother-boards. Each mother-board then is transported to a
separate area to cure. There is a minor amount of additional cutting to produce speciality boards such as rebated
or tongue & groove edges. Finished boards are stored in the warehouse before despatch to customers. Off cuts
from the cutting and trimming are compressed on-site and sent to landfill.
CT/PIR
4.1.A. LCA results - CT/PIR
Core environmental impact per 1m² 100mm CT/PIR, R-value 4.75 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

GWP-total [kg CO₂ eq.] 9.55E+00 2.07E-01 5.17E-01 1.03E+01 6.76E-02 6.69E-01 ND ND ND ND ND ND ND 0.00E+00 5.95E-02 2.71E+00 5.44E-01 -2.42E+00

GWP-fossil [kg CO₂ eq.] 1.01E+01 2.07E-01 3.13E-01 1.06E+01 6.76E-02 6.90E-01 ND ND ND ND ND ND ND 0.00E+00 5.95E-02 2.65E+00 3.14E-01 -2.41E+00

GWP-biogenic [kg CO₂ eq.] -7.05E-01 1.24E-04 2.03E-01 -5.02E-01 3.63E-05 -3.26E-02 ND ND ND ND ND ND ND 0.00E+00 3.20E-05 6.10E-02 2.31E-01 -1.61E-03

GWP-luluc [kg CO₂ eq.] 1.79E-01 7.82E-05 3.01E-05 1.79E-01 2.40E-05 1.16E-02 ND ND ND ND ND ND ND 0.00E+00 2.12E-05 2.09E-05 4.37E-05 -2.84E-03

ODP [kg CFC-11 eq.] 2.19E-07 4.63E-08 1.89E-08 2.84E-07 1.54E-08 1.89E-08 ND ND ND ND ND ND ND 0.00E+00 1.35E-08 1.40E-08 9.24E-09 -2.70E-07

AP [mol H+ eq.] 1.21E-02 1.18E-03 1.13E-03 1.44E-02 1.94E-04 9.42E-04 ND ND ND ND ND ND ND 0.00E+00 1.71E-04 2.28E-03 3.66E-04 -9.08E-03

EP-freshwater [kg P eq.] 1.19E-04 1.88E-06 2.10E-06 1.23E-04 5.40E-07 8.01E-06 ND ND ND ND ND ND ND 0.00E+00 4.75E-07 9.06E-07 1.32E-06 -6.14E-05

EP-marine [kg N eq.] 6.31E-03 2.32E-04 4.64E-04 7.01E-03 3.84E-05 4.57E-04 ND ND ND ND ND ND ND 0.00E+00 3.38E-05 1.27E-03 3.17E-03 -1.70E-03

EP-terrestrial [mol N eq.] 2.65E-02 2.61E-03 2.05E-03 3.11E-02 4.30E-04 2.03E-03 ND ND ND ND ND ND ND 0.00E+00 3.78E-04 1.21E-02 1.23E-03 -2.01E-02

POCP [kg NMVOC eq.] 1.84E-02 8.24E-04 1.44E-02 3.36E-02 1.65E-04 2.19E-03 ND ND ND ND ND ND ND 0.00E+00 1.45E-04 2.88E-03 1.41E-01 -5.29E-03

ADP-
[kg Sb eq.] 1.24E-04 5.01E-06 2.38E-06 1.32E-04 1.86E-06 8.60E-06 ND ND ND ND ND ND ND 0.00E+00 1.64E-06 1.23E-06 3.55E-07 -1.62E-05
minerals&metals [2]

ADP-fossils[2] [MJ] ncv 2.58E+02 3.11E+00 6.13E+00 2.67E+02 1.02E+00 1.74E+01 ND ND ND ND ND ND ND 0.00E+00 8.99E-01 1.40E+00 8.51E-01 -5.58E+01

m³ world eq.
WDP[2] 4.02E+00 1.08E-02 5.09E-02 4.09E+00 2.89E-03 2.66E-01 ND ND ND ND ND ND ND 0.00E+00 2.54E-03 1.65E-01 3.06E-02 -1.00E-01
deprived

GWP-total = Global Warming Potential total; GWP-fossil= Global Warming Potential fossil fuels (GWP-fossil; GWP-biogenic= Global Warming Potential biogenic; GWP-luluc= Global Warming Potential land use and land use
change; ODP = Depletion potential of the stratospheric ozone layer; AP =Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment;
EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-
minerals&fossils = Abiotic depletion potential for non-fossil resources; ADP-fossils= Abiotic depletion potential for fossil resources; WDP = Water (user) deprivation potential, deprivation-weighted water consumption.

The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator.
[2]

ND = Module not declared; INA = Indicator not assessed.


4.1.B. LCA results - CT/PIR
Resource use per 1m² 100mm CT/PIR, R-value 4.75 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

PERE [MJ] 2.47E+01 4.77E-02 8.45E-01 2.56E+01 1.46E-02 1.66E+00 ND ND ND ND ND ND ND 0.00E+00 1.29E-02 2.51E-02 3.46E-02 -9.84E+00

PERM [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

PERT [MJ] 2.47E+01 4.77E-02 8.45E-01 2.56E+01 1.46E-02 1.66E+00 ND ND ND ND ND ND ND 0.00E+00 1.29E-02 2.51E-02 3.46E-02 -9.84E+00

PENRE [MJ] 1.67E+02 3.30E+00 6.58E+00 1.77E+02 1.08E+00 1.76E+01 ND ND ND ND ND ND ND 0.00E+00 9.54E-01 1.53E+00 9.04E-01 -5.89E+01

PENRM [MJ] 9.36E+01 0.00E+00 0.00E+00 9.36E+01 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

PENRT [MJ] 2.60E+02 3.30E+00 6.58E+00 2.70E+02 1.08E+00 1.76E+01 ND ND ND ND ND ND ND 0.00E+00 9.54E-01 1.53E+00 9.04E-01 -5.89E+01

SM [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

RSF [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

NRSF [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

FW [m³] 2.21E+01 3.62E-04 1.60E-03 2.21E+01 1.09E-04 1.43E+00 ND ND ND ND ND ND ND 0.00E+00 9.61E-05 5.01E-03 7.98E-04 -1.04E-02

PERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary
energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials;
PENRT = Total use of non-renewable primary energy resources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Use of net fresh water.

ND = Module not declared; INA = Indicator not assessed.


4.1.C. LCA results - CT/PIR
Output flows and waste categories per 1m² 100mm CT/PIR, R-value 4.75 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

HWD [kg] 1.28E-04 7.40E-06 2.57E-07 1.36E-04 2.68E-06 8.92E-06 ND ND ND ND ND ND ND 0.00E+00 2.35E-06 2.67E-06 1.09E-06 -4.55E-05

NHWD [kg] 7.49E+00 1.34E-01 2.28E-01 7.85E+00 4.97E-02 5.11E-01 ND ND ND ND ND ND ND 0.00E+00 4.37E-02 5.01E-02 2.63E+00 -1.46E-01

RWD [kg] 2.77E-03 2.11E-05 4.01E-07 2.79E-03 6.96E-06 1.82E-04 ND ND ND ND ND ND ND 0.00E+00 6.12E-06 2.19E-06 4.50E-06 -4.53E-04

CRU [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

MFR [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

MER [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

EEE [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

EET [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

HWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed; CRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE =
Exported electrical energy; EET = Exported thermal energy.

CRU, MFR, MER, EEE, EET are not calculated by the EcoChain software.

ND = Module not declared; INA = Indicator not assessed.


4.1.D. LCA results - CT/PIR
Additonal Environmental impact per 1m² 100mm CT/PIR, R-value 4.75 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

PM Disease incidence 1.86E-07 1.23E-08 2.69E-09 2.01E-07 2.69E-09 4.29E-09 ND ND ND ND ND ND ND ND 3.78E-09 7.36E-09 5.27E-09 -3.54E-08

IRP[1] kBq U235 eq 3.71E+00 1.36E-02 2.00E-02 3.75E+00 2.00E-02 4.46E-03 ND ND ND ND ND ND ND ND 3.93E-03 1.64E-03 3.41E-03 -8.84E-01

ETP-fw[2] CTUe 3.84E+01 2.46E+00 3.76E+00 4.46E+01 3.76E+00 8.23E-01 ND ND ND ND ND ND ND ND 7.24E-01 6.88E+00 3.02E+01 -3.52E+01

HTP-c[2] CTUe 5.69E-08 6.98E-11 7.07E-11 5.71E-08 7.07E-11 2.29E-11 ND ND ND ND ND ND ND ND 2.02E-11 2.38E-10 2.56E-11 -7.78E-10

HTP-nc[2] CTUe 9.30E-07 2.51E-09 2.51E-09 9.35E-07 2.51E-09 8.67E-10 ND ND ND ND ND ND ND ND 7.63E-10 9.33E-09 1.22E-09 -2.60E-08

SQP[2] dimensionless 1.80E+02 1.98E+00 5.29E-01 1.82E+02 7.15E-01 1.19E+01 ND ND ND ND ND ND ND ND 6.29E-01 2.19E-01 1.59E+00 -3.06E+01

PM = Potential incidence of disease due to PM emissions, IRP = Potential Human exposure efficiency relative to U235, ETP-fw = Potential Comparative Toxic Unit for ecosystems; HTP-c:Potential Comparative Toxic Unit for
humans, HTP-nc = Potential Comparative Toxic Unit for humans, SQP = Potential soil quality index.

This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuelcycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor
[1]

due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
[2]
The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator.

ND = Module not declared; INA = Indicator not assessed.


FR/ALU
4.2.A. LCA results - FR/ALU
Core environmental impact per 1m² 100mm FR/ALU, R-value 4.5 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

GWP-total [kg CO₂ eq.] 9.57E+00 2.06E-01 5.17E-01 1.03E+01 6.74E-02 6.71E-01 ND ND ND ND ND ND ND 0.00E+00 5.93E-02 2.69E+00 5.04E-01 -2.42E+00

GWP-fossil [kg CO₂ eq.] 1.01E+01 2.06E-01 3.13E-01 1.06E+01 6.74E-02 6.89E-01 ND ND ND ND ND ND ND 0.00E+00 5.93E-02 2.64E+00 3.12E-01 -2.41E+00

GWP-biogenic [kg CO₂ eq.] -6.58E-01 1.23E-04 2.03E-01 -4.54E-01 3.62E-05 -2.95E-02 ND ND ND ND ND ND ND 0.00E+00 3.19E-05 5.08E-02 1.92E-01 -1.61E-03

GWP-luluc [kg CO₂ eq.] 1.75E-01 7.79E-05 3.01E-05 1.75E-01 2.40E-05 1.14E-02 ND ND ND ND ND ND ND 0.00E+00 2.11E-05 2.08E-05 4.32E-05 -2.84E-03

ODP [kg CFC-11 eq.] 2.30E-07 4.61E-08 1.89E-08 2.95E-07 1.53E-08 1.96E-08 ND ND ND ND ND ND ND 0.00E+00 1.35E-08 1.39E-08 9.16E-09 -2.70E-07

AP [mol H+ eq.] 1.21E-02 1.17E-03 1.13E-03 1.44E-02 1.94E-04 9.42E-04 ND ND ND ND ND ND ND 0.00E+00 1.70E-04 2.27E-03 3.61E-04 -9.08E-03

EP-freshwater [kg P eq.] 1.18E-04 1.87E-06 2.10E-06 1.22E-04 5.38E-07 7.93E-06 ND ND ND ND ND ND ND 0.00E+00 4.74E-07 9.01E-07 1.31E-06 -6.14E-05

EP-marine [kg N eq.] 6.27E-03 2.31E-04 4.64E-04 6.97E-03 3.83E-05 4.54E-04 ND ND ND ND ND ND ND 0.00E+00 3.37E-05 1.26E-03 3.13E-03 -1.70E-03

EP-terrestrial [mol N eq.] 2.63E-02 2.59E-03 2.05E-03 3.09E-02 4.29E-04 2.02E-03 ND ND ND ND ND ND ND 0.00E+00 3.77E-04 1.21E-02 1.22E-03 -2.01E-02

POCP [kg NMVOC eq.] 1.83E-02 8.20E-04 1.44E-02 3.36E-02 1.64E-04 2.19E-03 ND ND ND ND ND ND ND 0.00E+00 1.44E-04 2.87E-03 1.41E-01 -5.29E-03

ADP-
[kg Sb eq.] 1.30E-04 4.98E-06 2.38E-06 1.38E-04 1.86E-06 8.99E-06 ND ND ND ND ND ND ND 0.00E+00 1.64E-06 1.22E-06 3.52E-07 -1.62E-05
minerals&metals [2]

ADP-fossils[2] [MJ] ncv 2.57E+02 3.10E+00 6.13E+00 2.67E+02 1.02E+00 1.74E+01 ND ND ND ND ND ND ND 0.00E+00 8.97E-01 1.39E+00 8.43E-01 -5.58E+01

m³ world eq.
WDP[2] 4.02E+00 1.07E-02 5.09E-02 4.08E+00 2.88E-03 2.65E-01 ND ND ND ND ND ND ND 0.00E+00 2.54E-03 1.64E-01 3.03E-02 -1.00E-01
deprived

GWP-total = Global Warming Potential total; GWP-fossil= Global Warming Potential fossil fuels (GWP-fossil; GWP-biogenic= Global Warming Potential biogenic; GWP-luluc= Global Warming Potential land use and land use
change; ODP = Depletion potential of the stratospheric ozone layer; AP =Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment;
EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-
minerals&fossils = Abiotic depletion potential for non-fossil resources; ADP-fossils= Abiotic depletion potential for fossil resources; WDP = Water (user) deprivation potential, deprivation-weighted water consumption.

The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator.
[2]

ND = Module not declared; INA = Indicator not assessed.


4.2.B. LCA results - FR/ALU
Resource use per 1m² 100mm FR/ALU, R-value 4.5 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

PERE [MJ] 2.34E+01 4.75E-02 8.45E-01 2.43E+01 1.46E-02 1.58E+00 ND ND ND ND ND ND ND 0.00E+00 1.28E-02 2.49E-02 3.43E-02 -9.84E+00

PERM [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

PERT [MJ] 2.34E+01 4.75E-02 8.45E-01 2.43E+01 1.46E-02 1.58E+00 ND ND ND ND ND ND ND 0.00E+00 1.28E-02 2.49E-02 3.43E-02 -9.84E+00

PENRE [MJ] 1.67E+02 3.29E+00 6.58E+00 1.77E+02 1.08E+00 1.76E+01 ND ND ND ND ND ND ND 0.00E+00 9.52E-01 1.52E+00 8.97E-01 -5.89E+01

PENRM [MJ] 9.30E+01 0.00E+00 0.00E+00 9.30E+01 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

PENRT [MJ] 2.60E+02 3.29E+00 6.58E+00 2.70E+02 1.08E+00 1.76E+01 ND ND ND ND ND ND ND 0.00E+00 9.52E-01 1.52E+00 8.97E-01 -5.89E+01

SM [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

RSF [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

NRSF [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

FW [m³] 2.20E+01 3.60E-04 1.60E-03 2.20E+01 1.09E-04 1.43E+00 ND ND ND ND ND ND ND 0.00E+00 9.59E-05 4.99E-03 7.91E-04 -1.04E-02

PERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary
energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials;
PENRT = Total use of non-renewable primary energy resources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Use of net fresh water.

ND = Module not declared; INA = Indicator not assessed.


4.2.C. LCA results - FR/ALU
Output flows and waste categories per 1m² 100mm FR/ALU, R-value 4.5 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

HWD [kg] 1.34E-04 7.36E-06 2.57E-07 1.41E-04 2.67E-06 9.26E-06 ND ND ND ND ND ND ND 0.00E+00 2.35E-06 2.65E-06 1.08E-06 -4.55E-05

NHWD [kg] 7.47E+00 1.33E-01 2.28E-01 7.83E+00 4.95E-02 5.10E-01 ND ND ND ND ND ND ND 0.00E+00 4.36E-02 4.98E-02 2.61E+00 -1.46E-01

RWD [kg] 2.77E-03 2.10E-05 4.01E-07 2.79E-03 6.94E-06 1.81E-04 ND ND ND ND ND ND ND 0.00E+00 6.11E-06 2.18E-06 4.46E-06 -4.53E-04

CRU [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

MFR [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

MER [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

EEE [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

EET [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

HWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed; CRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE =
Exported electrical energy; EET = Exported thermal energy.

CRU, MFR, MER, EEE, EET are not calculated by the EcoChain software.

ND = Module not declared; INA = Indicator not assessed.


4.2.D. LCA results - FR/ALU
Additonal Environmental impact per 1m² 100mm FR/ALU, R-value 4.5 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

PM Disease incidence 1.84E-07 1.22E-08 2.69E-09 1.99E-07 4.28E-09 1.30E-08 ND ND ND ND ND ND ND ND 3.77E-09 7.32E-09 5.23E-09 -3.54E-08

IRP[1] kBq U235 eq 3.70E+00 1.36E-02 2.00E-02 3.74E+00 4.45E-03 2.43E-01 ND ND ND ND ND ND ND ND 3.92E-03 1.64E-03 3.38E-03 -8.84E-01

ETP-fw[2] CTUe 3.79E+01 2.45E+00 3.76E+00 4.42E+01 8.21E-01 2.89E+00 ND ND ND ND ND ND ND ND 7.22E-01 6.85E+00 3.15E+01 -3.52E+01

HTP-c[2] CTUe 5.68E-08 6.94E-11 7.07E-11 5.69E-08 2.28E-11 3.70E-09 ND ND ND ND ND ND ND ND 2.01E-11 2.37E-10 2.53E-11 -7.78E-10

HTP-nc[2] CTUe 9.28E-07 2.50E-09 2.51E-09 9.33E-07 8.65E-10 6.07E-08 ND ND ND ND ND ND ND ND 7.61E-10 9.28E-09 1.16E-09 -2.60E-08

SQP[2] dimensionless 1.76E+02 1.97E+00 5.29E-01 1.78E+02 7.13E-01 1.16E+01 ND ND ND ND ND ND ND ND 6.27E-01 2.18E-01 1.58E+00 -3.06E+01

PM = Potential incidence of disease due to PM emissions, IRP = Potential Human exposure efficiency relative to U235, ETP-fw = Potential Comparative Toxic Unit for ecosystems; HTP-c:Potential Comparative Toxic Unit for
humans, HTP-nc = Potential Comparative Toxic Unit for humans, SQP = Potential soil quality index.

This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuelcycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor
[1]

due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
[2]
The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator.

ND = Module not declared; INA = Indicator not assessed.


FR/BGM
4.3.A. LCA results - FR/BGM
Core environmental impact per 1m² 100mm FR/BGM, R-value 4.0 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

GWP-total [kg CO₂ eq.] 1.08E+01 2.62E-01 5.17E-01 1.15E+01 7.21E-02 7.52E-01 ND ND ND ND ND ND ND 0.00E+00 6.35E-02 2.74E+00 3.45E-01 -2.34E+00

GWP-fossil [kg CO₂ eq.] 1.10E+01 2.61E-01 3.13E-01 1.16E+01 7.21E-02 7.56E-01 ND ND ND ND ND ND ND 0.00E+00 6.34E-02 2.74E+00 3.45E-01 -2.34E+00

GWP-biogenic [kg CO₂ eq.] -4.66E-01 1.61E-04 2.03E-01 -2.62E-01 3.88E-05 -1.70E-02 ND ND ND ND ND ND ND 0.00E+00 3.41E-05 4.35E-04 4.08E-04 -1.55E-03

GWP-luluc [kg CO₂ eq.] 2.05E-01 1.01E-04 3.01E-05 2.05E-01 2.57E-05 1.34E-02 ND ND ND ND ND ND ND 0.00E+00 2.26E-05 2.24E-05 4.15E-05 -2.74E-03

ODP [kg CFC-11 eq.] 4.76E-07 5.81E-08 1.89E-08 5.53E-07 1.64E-08 3.63E-08 ND ND ND ND ND ND ND 0.00E+00 1.44E-08 1.46E-08 1.01E-08 -2.63E-07

AP [mol H+ eq.] 1.79E-02 1.74E-03 1.13E-03 2.08E-02 2.07E-04 1.36E-03 ND ND ND ND ND ND ND 0.00E+00 1.82E-04 2.29E-03 3.87E-04 -8.79E-03

EP-freshwater [kg P eq.] 1.38E-04 2.47E-06 2.10E-06 1.42E-04 5.76E-07 9.26E-06 ND ND ND ND ND ND ND 0.00E+00 5.07E-07 9.68E-07 1.26E-06 -5.92E-05

EP-marine [kg N eq.] 7.39E-03 3.42E-04 4.64E-04 8.19E-03 4.10E-05 5.34E-04 ND ND ND ND ND ND ND 0.00E+00 3.61E-05 1.25E-03 3.01E-03 -1.65E-03

EP-terrestrial [mol N eq.] 3.75E-02 3.84E-03 2.05E-03 4.34E-02 4.58E-04 2.83E-03 ND ND ND ND ND ND ND 0.00E+00 4.03E-04 1.20E-02 1.30E-03 -1.94E-02

POCP [kg NMVOC eq.] 2.52E-02 1.18E-03 1.44E-02 4.08E-02 1.76E-04 2.66E-03 ND ND ND ND ND ND ND 0.00E+00 1.55E-04 2.85E-03 1.40E-01 -5.12E-03

ADP-
[kg Sb eq.] 6.60E-05 6.01E-06 2.38E-06 7.44E-05 1.99E-06 4.89E-06 ND ND ND ND ND ND ND 0.00E+00 1.75E-06 1.29E-06 3.77E-07 -1.57E-05
minerals&metals [2]

ADP-fossils[2] [MJ] ncv 2.82E+02 3.92E+00 6.13E+00 2.92E+02 1.09E+00 1.90E+01 ND ND ND ND ND ND ND 0.00E+00 9.59E-01 1.42E+00 8.99E-01 -5.40E+01

m³ world eq.
WDP[2] 4.36E+00 1.44E-02 5.09E-02 4.43E+00 3.08E-03 2.88E-01 ND ND ND ND ND ND ND 0.00E+00 2.71E-03 1.62E-01 3.35E-02 -9.70E-02
deprived

GWP-total = Global Warming Potential total; GWP-fossil= Global Warming Potential fossil fuels (GWP-fossil; GWP-biogenic= Global Warming Potential biogenic; GWP-luluc= Global Warming Potential land use and land use
change; ODP = Depletion potential of the stratospheric ozone layer; AP =Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment;
EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-
minerals&fossils = Abiotic depletion potential for non-fossil resources; ADP-fossils= Abiotic depletion potential for fossil resources; WDP = Water (user) deprivation potential, deprivation-weighted water consumption.

The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator.
[2]

ND = Module not declared; INA = Indicator not assessed.


4.3.B. LCA results - FR/BGM
Resource use per 1m² 100mm FR/BGM, R-value 4.0 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

PERE [MJ] 1.81E+01 6.14E-02 8.45E-01 1.90E+01 1.56E-02 1.24E+00 ND ND ND ND ND ND ND 0.00E+00 1.37E-02 2.62E-02 3.28E-02 -9.49E+00

PERM [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

PERT [MJ] 1.81E+01 6.14E-02 8.45E-01 1.90E+01 1.56E-02 1.24E+00 ND ND ND ND ND ND ND 0.00E+00 1.37E-02 2.62E-02 3.28E-02 -9.49E+00

PENRE [MJ] 1.88E+02 4.16E+00 6.58E+00 1.99E+02 1.16E+00 1.93E+01 ND ND ND ND ND ND ND 0.00E+00 1.02E+00 1.56E+00 9.55E-01 -5.69E+01

PENRM [MJ] 9.78E+01 0.00E+00 0.00E+00 9.78E+01 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

PENRT [MJ] 2.86E+02 4.16E+00 6.58E+00 2.97E+02 1.16E+00 1.93E+01 ND ND ND ND ND ND ND 0.00E+00 1.02E+00 1.56E+00 9.55E-01 -5.69E+01

SM [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

RSF [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

NRSF [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

FW [m³] 2.21E+01 4.68E-04 1.60E-03 2.21E+01 1.17E-04 1.43E+00 ND ND ND ND ND ND ND 0.00E+00 1.03E-04 4.93E-03 8.62E-04 -1.01E-02

PERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary
energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials;
PENRT = Total use of non-renewable primary energy resources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Use of net fresh water.

ND = Module not declared; INA = Indicator not assessed.


4.3.C. LCA results - FR/BGM
Output flows and waste categories per 1m² 100mm FR/BGM, R-value 4.0 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

HWD [kg] 4.13E-05 8.98E-06 2.57E-07 5.05E-05 2.85E-06 3.36E-06 ND ND ND ND ND ND ND 0.00E+00 2.51E-06 2.73E-06 1.19E-06 -4.41E-05

NHWD [kg] 7.58E+00 1.61E-01 2.28E-01 7.97E+00 5.30E-02 5.19E-01 ND ND ND ND ND ND ND 0.00E+00 4.66E-02 5.36E-02 2.94E+00 -1.41E-01

RWD [kg] 2.87E-03 2.65E-05 4.01E-07 2.90E-03 7.42E-06 1.88E-04 ND ND ND ND ND ND ND 0.00E+00 6.53E-06 2.41E-06 4.88E-06 -4.37E-04

CRU [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

MFR [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

MER [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

EEE [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

EET [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

HWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed; CRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE =
Exported electrical energy; EET = Exported thermal energy.

CRU, MFR, MER, EEE, EET are not calculated by the EcoChain software.

ND = Module not declared; INA = Indicator not assessed.


4.3.D. LCA results - FR/BGM
Additonal Environmental impact per 1m² 100mm FR/BGM, R-value 4.0 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

PM Disease incidence 2.17E-07 1.51E-08 2.69E-09 2.35E-07 4.58E-09 1.54E-08 ND ND ND ND ND ND ND ND 4.03E-09 7.77E-09 5.69E-09 -3.44E-08

IRP[1] kBq U235 eq 3.78E+00 1.72E-02 2.00E-02 3.82E+00 4.76E-03 2.48E-01 ND ND ND ND ND ND ND ND 4.19E-03 1.80E-03 3.60E-03 -8.52E-01

ETP-fw[2] CTUe 6.26E+01 3.07E+00 3.76E+00 6.94E+01 8.78E-01 4.53E+00 ND ND ND ND ND ND ND ND 7.72E-01 6.76E+00 5.84E+00 -3.40E+01

HTP-c[2] CTUe 5.79E-08 8.78E-11 7.07E-11 5.81E-08 2.44E-11 3.77E-09 ND ND ND ND ND ND ND ND 2.15E-11 2.36E-10 2.53E-11 -7.53E-10

HTP-nc[2] CTUe 9.70E-07 3.11E-09 2.51E-09 9.75E-07 9.25E-10 6.34E-08 ND ND ND ND ND ND ND ND 8.14E-10 9.18E-09 8.76E-10 -2.52E-08

SQP[2] dimensionless 1.66E+02 2.40E+00 5.29E-01 1.69E+02 7.62E-01 1.10E+01 ND ND ND ND ND ND ND ND 6.71E-01 2.77E-01 1.75E+00 -2.96E+01

PM = Potential incidence of disease due to PM emissions, IRP = Potential Human exposure efficiency relative to U235, ETP-fw = Potential Comparative Toxic Unit for ecosystems; HTP-c:Potential Comparative Toxic Unit for
humans, HTP-nc = Potential Comparative Toxic Unit for humans, SQP = Potential soil quality index.

This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuelcycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor
[1]

due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
[2]
The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator.

ND = Module not declared; INA = Indicator not assessed.


FR/MG
4.4.A. LCA results - FR/MG
Core environmental impact per 1m² 100mm FR/MG, R-value 4.0 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

GWP-total [kg CO₂ eq.] 1.15E+01 2.86E-01 5.17E-01 1.23E+01 7.11E-02 8.03E-01 ND ND ND ND ND ND ND 0 6.26E-02 2.59E+00 3.07E-01 -2.34E+00

GWP-fossil [kg CO₂ eq.] 1.18E+01 2.86E-01 3.13E-01 1.24E+01 7.11E-02 8.06E-01 ND ND ND ND ND ND ND 0 6.25E-02 2.59E+00 3.07E-01 -2.34E+00

GWP-biogenic [kg CO₂ eq.] -4.79E-01 1.81E-04 2.03E-01 -2.76E-01 3.82E-05 -1.79E-02 ND ND ND ND ND ND ND 0 3.36E-05 6.39E-04 3.96E-04 -1.55E-03

GWP-luluc [kg CO₂ eq.] 2.36E-01 1.12E-04 3.01E-05 2.36E-01 2.53E-05 1.54E-02 ND ND ND ND ND ND ND 0 2.23E-05 2.13E-05 4.05E-05 -2.74E-03

ODP [kg CFC-11 eq.] 4.13E-07 6.32E-08 1.89E-08 4.95E-07 1.62E-08 3.26E-08 ND ND ND ND ND ND ND 0 1.42E-08 1.43E-08 9.99E-09 -2.63E-07

AP [mol H+ eq.] 2.21E-02 2.13E-03 1.13E-03 2.54E-02 2.04E-04 1.66E-03 ND ND ND ND ND ND ND 0 1.80E-04 2.24E-03 3.63E-04 -8.79E-03

EP-freshwater [kg P eq.] 1.68E-04 2.80E-06 2.10E-06 1.73E-04 5.68E-07 1.13E-05 ND ND ND ND ND ND ND 0 4.99E-07 9.28E-07 1.23E-06 -5.92E-05

EP-marine [kg N eq.] 8.41E-03 4.19E-04 4.64E-04 9.29E-03 4.04E-05 6.05E-04 ND ND ND ND ND ND ND 0 3.56E-05 1.24E-03 2.98E-03 -1.65E-03

EP-terrestrial [mol N eq.] 4.79E-02 4.71E-03 2.05E-03 5.46E-02 4.52E-04 3.56E-03 ND ND ND ND ND ND ND 0 3.98E-04 1.19E-02 1.28E-03 -1.94E-02

POCP [kg NMVOC eq.] 3.12E-02 1.41E-03 1.44E-02 4.70E-02 1.73E-04 3.06E-03 ND ND ND ND ND ND ND 0 1.52E-04 2.83E-03 1.40E-01 -5.12E-03

ADP-
[kg Sb eq.] 9.18E-05 6.30E-06 2.38E-06 1.00E-04 1.96E-06 6.58E-06 ND ND ND ND ND ND ND 0 1.73E-06 1.25E-06 3.70E-07 -1.57E-05
minerals&metals [2]

ADP-fossils[2] [MJ] ncv 2.84E+02 4.28E+00 6.13E+00 2.95E+02 1.07E+00 1.92E+01 ND ND ND ND ND ND ND 0 9.45E-01 1.42E+00 8.83E-01 -5.40E+01

m³ world eq.
WDP[2] 4.61E+00 1.66E-02 5.09E-02 4.67E+00 3.04E-03 3.04E-01 ND ND ND ND ND ND ND 0 2.68E-03 1.59E-01 3.30E-02 -9.70E-02
deprived

GWP-total = Global Warming Potential total; GWP-fossil= Global Warming Potential fossil fuels (GWP-fossil; GWP-biogenic= Global Warming Potential biogenic; GWP-luluc= Global Warming Potential land use and land use
change; ODP = Depletion potential of the stratospheric ozone layer; AP =Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment;
EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-
minerals&fossils = Abiotic depletion potential for non-fossil resources; ADP-fossils= Abiotic depletion potential for fossil resources; WDP = Water (user) deprivation potential, deprivation-weighted water consumption.

The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator.
[2]

ND = Module not declared; INA = Indicator not assessed.


4.4.B. LCA results - FR/MG
Resource use per 1m² 100mm FR/MG, R-value 4.0 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

PERE [MJ] 1.91E+01 6.84E-02 8.45E-01 2.01E+01 1.54E-02 1.30E+00 ND ND ND ND ND ND ND 0 1.35E-02 2.52E-02 3.21E-02 -9.49E+00

PERM [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0 0.00E+00 0.00E+00 0.00E+00 0.00E+00

PERT [MJ] 1.91E+01 6.84E-02 8.45E-01 2.01E+01 1.54E-02 1.30E+00 ND ND ND ND ND ND ND 0 1.35E-02 2.52E-02 3.21E-02 -9.49E+00

PENRE [MJ] 2.01E+02 4.54E+00 6.58E+00 2.12E+02 1.14E+00 1.95E+01 ND ND ND ND ND ND ND 0 1.00E+00 1.56E+00 9.39E-01 -5.69E+01

PENRM [MJ] 8.83E+01 0.00E+00 0.00E+00 8.83E+01 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0 0.00E+00 0.00E+00 0.00E+00 0.00E+00

PENRT [MJ] 2.89E+02 4.54E+00 6.58E+00 3.00E+02 1.14E+00 1.95E+01 ND ND ND ND ND ND ND 0 1.00E+00 1.56E+00 9.39E-01 -5.69E+01

SM [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0 0.00E+00 0.00E+00 0.00E+00 0.00E+00

RSF [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0 0.00E+00 0.00E+00 0.00E+00 0.00E+00

NRSF [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0 0.00E+00 0.00E+00 0.00E+00 0.00E+00

FW [m³] 2.21E+01 5.23E-04 1.60E-03 2.21E+01 1.15E-04 1.44E+00 ND ND ND ND ND ND ND 0 1.01E-04 4.84E-03 8.49E-04 -1.01E-02

PERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary
energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials;
PENRT = Total use of non-renewable primary energy resources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Use of net fresh water.

ND = Module not declared; INA = Indicator not assessed.


4.4.C. LCA results - FR/MG
Output flows and waste categories per 1m² 100mm FR/MG, R-value 4.0 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

HWD [kg] 5.44E-05 9.51E-06 2.57E-07 6.42E-05 2.81E-06 4.24E-06 ND ND ND ND ND ND ND 0.00E+00 2.48E-06 2.72E-06 1.17E-06 -4.41E-05

NHWD [kg] 7.69E+00 1.69E-01 2.28E-01 8.09E+00 5.22E-02 5.27E-01 ND ND ND ND ND ND ND 0.00E+00 4.60E-02 5.06E-02 2.90E+00 -1.41E-01

RWD [kg] 2.83E-03 2.89E-05 4.01E-07 2.85E-03 7.32E-06 1.86E-04 ND ND ND ND ND ND ND 0.00E+00 6.44E-06 2.48E-06 4.80E-06 -4.37E-04

CRU [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

MFR [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

MER [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

EEE [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

EET [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

HWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed; CRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE =
Exported electrical energy; EET = Exported thermal energy.

CRU, MFR, MER, EEE, EET are not calculated by the EcoChain software.

ND = Module not declared; INA = Indicator not assessed.


4.4.D. LCA results - FR/MG
Additonal Environmental impact per 1m² 100mm FR/MG, R-value 4.0 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

PM Disease incidence 2.56E-07 1.62E-08 2.69E-09 2.75E-07 4.52E-09 1.80E-08 ND ND ND ND ND ND ND ND 3.97E-09 7.75E-09 5.58E-09 -3.44E-08

IRP[1] kBq U235 eq 3.77E+00 1.88E-02 2.00E-02 3.81E+00 4.70E-03 2.48E-01 ND ND ND ND ND ND ND ND 4.13E-03 1.82E-03 3.54E-03 -8.52E-01

ETP-fw[2] CTUe 8.06E+01 3.33E+00 3.76E+00 8.77E+01 8.65E-01 5.73E+00 ND ND ND ND ND ND ND ND 7.62E-01 6.74E+00 5.78E+00 -3.40E+01

HTP-c[2] CTUe 5.90E-08 9.59E-11 7.07E-11 5.91E-08 2.41E-11 3.84E-09 ND ND ND ND ND ND ND ND 2.12E-11 2.34E-10 2.47E-11 -7.53E-10

HTP-nc[2] CTUe 1.01E-06 3.34E-09 2.51E-09 1.01E-06 9.12E-10 6.59E-08 ND ND ND ND ND ND ND ND 8.02E-10 9.06E-09 8.61E-10 -2.52E-08

SQP[2] dimensionless 1.69E+02 2.54E+00 5.29E-01 1.72E+02 7.52E-01 1.12E+01 ND ND ND ND ND ND ND ND 6.61E-01 3.04E-01 1.71E+00 -2.96E+01

PM = Potential incidence of disease due to PM emissions, IRP = Potential Human exposure efficiency relative to U235, ETP-fw = Potential Comparative Toxic Unit for ecosystems; HTP-c:Potential Comparative Toxic Unit for
humans, HTP-nc = Potential Comparative Toxic Unit for humans, SQP = Potential soil quality index.

This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuelcycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor
[1]

due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
[2]
The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator.

ND = Module not declared; INA = Indicator not assessed.


Thin-R
4.5.A. LCA results - Thin-R
Core environmental impact per 1m² 100mm Thin-R, R-value 4.5 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

GWP-total [kg CO₂ eq.] 9.55E+00 2.07E-01 5.17E-01 1.03E+01 6.76E-02 6.70E-01 ND ND ND ND ND ND ND 0 5.95E-02 2.70E+00 5.43E-01 -2.42E+00

GWP-fossil [kg CO₂ eq.] 1.01E+01 2.07E-01 3.13E-01 1.06E+01 6.76E-02 6.91E-01 ND ND ND ND ND ND ND 0 5.95E-02 2.64E+00 3.13E-01 -2.41E+00

GWP-biogenic [kg CO₂ eq.] -7.00E-01 1.24E-04 2.03E-01 -4.97E-01 3.63E-05 -3.23E-02 ND ND ND ND ND ND ND 0 3.20E-05 6.10E-02 2.31E-01 -1.61E-03

GWP-luluc [kg CO₂ eq.] 1.75E-01 7.82E-05 3.01E-05 1.75E-01 2.40E-05 1.14E-02 ND ND ND ND ND ND ND 0 2.12E-05 2.08E-05 4.35E-05 -2.84E-03

ODP [kg CFC-11 eq.] 2.33E-07 4.63E-08 1.89E-08 2.98E-07 1.54E-08 1.98E-08 ND ND ND ND ND ND ND 0 1.35E-08 1.39E-08 9.21E-09 -2.70E-07

AP [mol H+ eq.] 1.22E-02 1.18E-03 1.13E-03 1.45E-02 1.94E-04 9.50E-04 ND ND ND ND ND ND ND 0 1.71E-04 2.27E-03 3.65E-04 -9.08E-03

EP-freshwater [kg P eq.] 1.19E-04 1.88E-06 2.10E-06 1.23E-04 5.40E-07 8.03E-06 ND ND ND ND ND ND ND 0 4.75E-07 9.04E-07 1.31E-06 -6.14E-05

EP-marine [kg N eq.] 6.31E-03 2.32E-04 4.64E-04 7.00E-03 3.84E-05 4.56E-04 ND ND ND ND ND ND ND 0 3.38E-05 1.26E-03 3.16E-03 -1.70E-03

EP-terrestrial [mol N eq.] 2.67E-02 2.60E-03 2.05E-03 3.13E-02 4.30E-04 2.05E-03 ND ND ND ND ND ND ND 0 3.78E-04 1.21E-02 1.23E-03 -2.01E-02

POCP [kg NMVOC eq.] 1.84E-02 8.24E-04 1.44E-02 3.37E-02 1.65E-04 2.19E-03 ND ND ND ND ND ND ND 0 1.45E-04 2.87E-03 1.41E-01 -5.29E-03

ADP-
[kg Sb eq.] 1.24E-04 5.00E-06 2.38E-06 1.32E-04 1.86E-06 8.61E-06 ND ND ND ND ND ND ND 0 1.64E-06 1.22E-06 3.54E-07 -1.62E-05
minerals&metals [2]

ADP-fossils[2] [MJ] ncv 2.58E+02 3.11E+00 6.13E+00 2.67E+02 1.02E+00 1.74E+01 ND ND ND ND ND ND ND 0 8.99E-01 1.39E+00 8.48E-01 -5.58E+01

m³ world eq.
WDP[2] 4.06E+00 1.08E-02 5.09E-02 4.12E+00 2.89E-03 2.68E-01 ND ND ND ND ND ND ND 0 2.54E-03 1.64E-01 3.05E-02 -1.00E-01
deprived

GWP-total = Global Warming Potential total; GWP-fossil= Global Warming Potential fossil fuels (GWP-fossil; GWP-biogenic= Global Warming Potential biogenic; GWP-luluc= Global Warming Potential land use and land use
change; ODP = Depletion potential of the stratospheric ozone layer; AP =Acidification potential, Accumulated Exceedance; EP-freshwater = Eutrophication potential, fraction of nutrients reaching freshwater end compartment;
EP-marine = Eutrophication potential, fraction of nutrients reaching marine end compartment; EP-terrestrial = Eutrophication potential, Accumulated Exceedance; POCP = Formation potential of tropospheric ozone; ADP-
minerals&fossils = Abiotic depletion potential for non-fossil resources; ADP-fossils= Abiotic depletion potential for fossil resources; WDP = Water (user) deprivation potential, deprivation-weighted water consumption.

The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator.
[2]

ND = Module not declared; INA = Indicator not assessed.


4.5.B. LCA results - Thin-R
Resource use per 1m² 100mm Thin-R, R-value 4.5 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

PERE [MJ] 2.47E+01 4.77E-02 8.45E-01 2.56E+01 1.46E-02 1.66E+00 ND ND ND ND ND ND ND 0 1.29E-02 2.50E-02 3.45E-02 -9.84E+00

PERM [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0 0.00E+00 0.00E+00 0.00E+00 0.00E+00

PERT [MJ] 2.47E+01 4.77E-02 8.45E-01 2.56E+01 1.46E-02 1.66E+00 ND ND ND ND ND ND ND 0 1.29E-02 2.50E-02 3.45E-02 -9.84E+00

PENRE [MJ] 1.67E+02 3.30E+00 6.58E+00 1.77E+02 1.08E+00 1.76E+01 ND ND ND ND ND ND ND 0 9.54E-01 1.53E+00 9.02E-01 -5.89E+01

PENRM [MJ] 9.36E+01 0.00E+00 0.00E+00 9.36E+01 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0 0.00E+00 0.00E+00 0.00E+00 0.00E+00

PENRT [MJ] 2.60E+02 3.30E+00 6.58E+00 2.70E+02 1.08E+00 1.76E+01 ND ND ND ND ND ND ND 0 9.54E-01 1.53E+00 9.02E-01 -5.89E+01

SM [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0 0.00E+00 0.00E+00 0.00E+00 0.00E+00

RSF [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0 0.00E+00 0.00E+00 0.00E+00 0.00E+00

NRSF [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0 0.00E+00 0.00E+00 0.00E+00 0.00E+00

FW [m³] 2.20E+01 3.62E-04 1.60E-03 2.20E+01 1.09E-04 1.43E+00 ND ND ND ND ND ND ND 0 9.61E-05 5.00E-03 7.96E-04 -1.04E-02

PERE = Use of renewable primary energy excluding renewable primary energy resources used as raw materials; PERM = Use of renewable primary energy resources used as raw materials; PERT = Total use of renewable primary
energy resources; PENRE = Use of non-renewable primary energy excluding non-renewable primary energy resources used as raw materials; PENRM = Use of non-renewable primary energy resources used as raw materials;
PENRT = Total use of non-renewable primary energy resources; SM = Use of secondary material; RSF = Use of renewable secondary fuels; NRSF = Use of non-renewable secondary fuels; FW = Use of net fresh water.

ND = Module not declared; INA = Indicator not assessed.


4.5.C. LCA results - Thin-R
Output flows and waste categories per 1m² 100mm Thin-R, R-value 4.5 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

HWD [kg] 1.29E-04 7.39E-06 2.57E-07 1.36E-04 2.68E-06 8.93E-06 ND ND ND ND ND ND ND 0.00E+00 2.35E-06 2.66E-06 1.09E-06 -4.55E-05

NHWD [kg] 7.47E+00 1.34E-01 2.28E-01 7.83E+00 4.97E-02 5.10E-01 ND ND ND ND ND ND ND 0.00E+00 4.37E-02 5.00E-02 2.62E+00 -1.46E-01

RWD [kg] 2.77E-03 2.11E-05 4.01E-07 2.79E-03 6.96E-06 1.81E-04 ND ND ND ND ND ND ND 0.00E+00 6.12E-06 2.19E-06 4.49E-06 -4.53E-04

CRU [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

MFR [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

MER [kg] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

EEE [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

EET [MJ] 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 ND ND ND ND ND ND ND 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00

HWD = Hazardous waste disposed; NHWD = Non-hazardous waste disposed; RWD = Radioactive waste disposed; CRU = Components for re-use; MFR = Materials for recycling; MER = Materials for energy recovery; EEE =
Exported electrical energy; EET = Exported thermal energy.

CRU, MFR, MER, EEE, EET are not calculated by the EcoChain software.

ND = Module not declared; INA = Indicator not assessed.


4.5.D. LCA results - Thin-R
Additonal Environmental impact per 1m² 100mm Thin-R, R-value 4.5 m²K/W

TOTAL
PARAMETER UNIT A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 B6 B7 C1 C2 C3 C4 D
A1-A3

PM Disease incidence 1.86E-07 1.23E-08 2.69E-09 2.01E-07 4.29E-09 1.32E-08 ND ND ND ND ND ND ND ND 3.78E-09 7.34E-09 5.26E-09 -3.54E-08

IRP[1] kBq U235 eq 3.71E+00 1.36E-02 2.00E-02 3.74E+00 4.46E-03 2.43E-01 ND ND ND ND ND ND ND ND 3.93E-03 1.64E-03 3.40E-03 -8.84E-01

ETP-fw[2] CTUe 3.88E+01 2.46E+00 3.76E+00 4.50E+01 8.23E-01 2.95E+00 ND ND ND ND ND ND ND ND 7.24E-01 6.86E+00 3.02E+01 -3.52E+01

HTP-c[2] CTUe 5.68E-08 6.97E-11 7.07E-11 5.70E-08 2.29E-11 3.70E-09 ND ND ND ND ND ND ND ND 2.02E-11 2.37E-10 2.55E-11 -7.78E-10

HTP-nc[2] CTUe 9.28E-07 2.51E-09 2.51E-09 9.33E-07 8.67E-10 6.07E-08 ND ND ND ND ND ND ND ND 7.63E-10 9.30E-09 1.22E-09 -2.60E-08

SQP[2] dimensionless 1.79E+02 1.97E+00 5.29E-01 1.82E+02 7.15E-01 1.18E+01 ND ND ND ND ND ND ND ND 6.29E-01 2.18E-01 1.59E+00 -3.06E+01

PM = Potential incidence of disease due to PM emissions, IRP = Potential Human exposure efficiency relative to U235, ETP-fw = Potential Comparative Toxic Unit for ecosystems; HTP-c:Potential Comparative Toxic Unit for
humans, HTP-nc = Potential Comparative Toxic Unit for humans, SQP = Potential soil quality index.

This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuelcycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor
[1]

due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
[2]
The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experienced with the indicator.

ND = Module not declared; INA = Indicator not assessed.


5. Calculation rules
The measurement of environmental impacts in this EPD uses the LCIA methodologies recommended for PEF3.0.
The indicator values for polyol and MDI are from Plastics Europe Ecoprofile (GaBi); and the impact assessment
results of these materials were calculated using OpenLCA. As this EPD is based on Ecoinvent database, there
can be a lack of consistency between GaBi and Ecoinvent indicators such as toxicities, ozone depletion and
hazardous waste disposal, although there is good agreement on global warming potential.

The process descriptions and quantities in this study are reproducible in accordance to the reference standards
that have been used. The references of all sources, both primary and public sources and literature, have been
documented in the LCA report. The ‘polluter pays’ and ‘modularity’ principles have been followed.

In addition, to facilitate the reproducibility of this LCA, a full set of data records has been generated which can
be accessed via the Ecochain LCA tool. This data portfolio contains a summary of all the data used in this LCA,
and correspondingly, in the Unilin Insulation Ireland Ltd Ecochain account.

Cut-off criteria
The cut-off criteria of section 6.3.6 of EN15804 +A2 have been followed.

Data Quality
The dataset is representative for the production processes used in 2019. The data Quality Level, according to
Table E.1 of EN 15804 +A2, Annex E, is 'very good'.

Allocations
Allocation of electricity types and amounts to the various manufacturing processes has been provided by Unilin
Insulation Ireland Ltd , along with production waste and direct emissions; allocation of impacts to the products
is based on the product composition mass.

6. Scenarios and additional technical information


The product and data used in this EPD are based on the being manufactured in, and transported to customers
within the UK geographic region.

C1. De-construction demolition


It is assumed the insulation panes are removed manually from site, thus no energy or materials are required for
Module C1.

C2. Transport
In the transport phase C2, it is assumed that the removed materials travel 50km to landfill and 250km to
incineration, as applicable. Transport vehicle type: Freight lorry 16-32 metric ton, EURO6.

C3. Waste processing


Based on feedback supplied by Unilin Insulation Ireland Ltd , it is assumed that 30% of the material at end of life
is processed, by being burned in an incineration plant.

C4. Disposal
Based on feedback supplied by Unilin Insulation Ireland Ltd , it is assumed that 70% of the material at end of life
is disposed of in landfill.
D. Reuse – Recovery – Recycling potential
It is assumed that of the mass of material incinerated, 40% of this mass is converted to energy. It is assumed that
in calculating this energy amount, that the efficiency of the incineration in converting NCV to energy is 70%.

Of this energy, it is assumed that 82% becomes electricity, and 12% becomes heat (based on UK energy statistics,
from “UK energy from waste statistics - 2020”, Tolvic Consulting).

Declaration of biogenic carbon content at the production gate


The weight of packaging is << than 5% of the mas of the products, and is not declared below.

Biogenic carbon (kg per declared unit) Unit CT/PIR FR/ALU FR/BGM FR/MG Thin-R

Biogenic carbon content in product kg C 0.19 0.18 0.13 0.13 0.19

Biogenic carbon content in packaging kg C ND ND ND ND ND

ND = Module not declared.

7. Mandatory additional information on release of dangerous substances to


indoor air, soil and water
None of the substances contained in the product are listed in the “Candidate List of Substances of Very High
Concern for authorisation”, or they do not exceed the limit for registration with the European Chemicals Agency.

8. Other optional additional environmental information


N/A.
9. References
1. ISO 14040 Environmental management - Life cycle assessment – Principles and Framework’, International
Organization for Standardization, ISO 14040:2006.

2. ISO 14044 Environmental management - Life cycle assessment - Requirements and guidelines’, International
Organization for Standardization, ISO 14044:2006

3. ISO 14025 Environmental labels and declarations -- Type III environmental declarations -- Principles and
procedures’, International Organization for Standardization, ISO 14025:2006.

4. I.S. EN 15804:2012+A1:2013 Sustainability of construction works - Environmental product declarations - Core


rules for the product category of construction products’, EN 15804:2012+A1:2013.

5. Product Category Rules: Part A, Version 2.0. Implementation and use of I.S. EN 15804:2012 and CEN TR
16970:2016 in Ireland, EPD Ireland, IGBC, 17/08/2021.

6. I.S. EN 16783:2017 Thermal insulation products – Product category rules (PCR) for factory made and in-situ
formed products for preparing environmental product declarations.

7. Ecochain, 2017version 3.3, dated 10/09/2021, web: http://app.ecochain.com.

8. I.S. EN 13165:2008, Thermal insulation products for buildings. Factory made rigid polyurethane foam (PUR)
products. Specification.

9. PEF methodology final draft.pdf (europa.eu)

10. UK Energy from Waste Statistics - 2020. Tolvic Consulting. (https://www.tolvik.com/published-reports/view/