Three Phase String Inverter

SUN-30/33/35/36K-G04

2 MPP trackers, Max. efficiency up to 98.6%

Zero export application, VSG application

String intelligent monitoring (optional)

Wide output voltage range

Anti-PID function (Optional)

Stock Code: 605117.SH


Technical Data www.deyeinverter.com

Model SUN-30K-G04 SUN-33K-G04 SUN-35K-G04 SUN-36K-G04

Input Side
Max. DC Input Power (kW) 39 42.9 45.5 46.8
Max. DC Input Voltage (V) 1000
Start-up DC Input Voltage (V) 250
MPPT Operating Range (V) 200-850
Max. DC Input Current (A) 40+40
Max. Short Circuit Current (A) 60+60
No.of MPP Trackers 2
No.of Strings per MPP Tracker 3+3
Output Side
Rated Output Power (kW) 30 33 35 36
Max. Active Power (kW) 33 36.3 38.5 39.6
Nominal Output Voltage / Range (V) 3L/N/PE 220/380V, 230/400V
Rated Grid Frequency (Hz) 50 / 60 (Optional)
Operating Phase Three Phase
Rated AC Grid Output Current (A) 45.5/43.5 50/47.8 53/50.7 54.5/52.2
Max. AC Output Current (A) 50/47.9 55/52.6 58.3/55.8 60/57.4
Output Power Factor 0.8 leading to 0.8 lagging
Total Harmonics Current Distortion (THDi) <3%
DC Injection Current (mA) <0.5%
Grid Frequency Range 45~55 or 55~65 (Optional)
Efficiency
Max. Efficiency 98.6%
Euro Efficiency 97.8%
MPPT Efficiency >99%
Protection
DC Reverse-Polarity Protection Yes
AC Short Circuit Protection Yes
AC Output Overcurrent Protection Yes
Output Overvoltage Protection Yes
Insulation Resistance Protection Yes
Ground Fault Monitoring Yes
Anti-islanding Protection Yes
Temperature Protection Yes
Integrated DC Switch Yes
Remote Software Upload Yes
Remote Change of Operating Parameters Yes
Surge Protection DC Type II / AC Type II
General Data
Cabinet Size (WxHxD mm) 362×577×215 (Excluding Connectors and Brackets)
Weight (kg) 23
Topology Transformerless
Internal Consumption <1W (Night)
Running Temperature -25-65℃, >45℃ Derating
Ingress Protection IP65
Noise Emission (Typical) ≤50 dB
Cooling Concept Smart Cooling
Permissible Altitude (m) 2000
Warranty 5 Years
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
Grid Connection Standard
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Operating Surroundings Humidity 0-100%
Safety EMC / Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Features
Display LCD1602
Interface RS485/RS232/Wifi/LAN

Ningbo Deye Inverter Technology Co., Ltd.


Add: No. 26 South YongJiang Road, Daqi, Beilun, NingBo, Zhejiang, China. | Tel: 0086-0574-86120560 | E-mail: [email protected]