Electrosurgery

Smart features, optimal outcomes

Driven by
safety.
Focused on
quality.
Table of contents
3 Electrosurgical pencils

Why use Medline’s electrosurgical pencils?


Electrosurgical pencils with standard stainless-steel tips
Electrosurgical pencil with non-stick PTFE-coated tips

7 Electrosurgical active electrodes (tips)

Stainless-steel electrodes, single use, sterile


Non-stick PTFE-coated electrodes, single use, sterile

10 Accessories

Electrosurgical tip cleaner

11 Service and support


Electrosurgical
pencils
With Medline’s electrosurgical products,
you have it all: unique safety features and a
complete selection of high-quality products
and support that are second to none.

Choose from sterile pencils in push button


and rocker switch configurations. Pencils
are available alone or with a holster to help
promote safety practices, such as those
recommended by groups like the Association for
Perioperative Practice (AfPP).*

Medline also offers a pencil with a non-stick


polytetrafluoroethylene (PTFE) tip already
attached. This increases efficiency and
eliminates waste as non-stick tips no longer
need to be picked separately, eliminating the
cost of the stainless-steel blade.

*AfPP standards and recommendations for safe perioperative


practice in 2011 suggest that the active electrode should be
stored securely in a non-conductive container when not in use.

Page 3
Why use Medline’s
electrosurgical pencils?
Designed exclusively for surgeons who prefer a more traditional feel, these pencils
feature tactile buttons, less memory in the cords and high-quality plugs.

Nickel-plated pins Soft, flexible cord Double-moulded plug

Soft buttons

One-piece nose

Page 4
Electrosurgical pencils with standard
stainless-steel tips
• For most standard 2.4 mm shaft electrodes
• Manufactured with the highest quality standards in compliance with IEC electrical safety
standard 60601-2-2
• Fully guaranteed (see page 11 for guarantee and indemnification policy)
• Available with or without safety holster

ESPB4000Q

ESRK4001Q

Standard stainless-steel tip, sterile1

Pack component
Item number Description Packaging
number
ESPB4000Q Push button, blade electrode, 3 m cord with holster 60/cs ESPB4000NSA-EU

ESPB4001Q Push button, blade electrode, 3 m cord without holster 100/cs 55729-EU
55720A-EU +
ESPB4000LQ Push button, blade electrode, 5 m cord with holster 60/cs
82499-EU
ESPB4001LQ Push button, blade electrode, 5 m cord without holster 80/cs 55720A-EU
Push button, blade electrode, ERBE connector, 3 m cord
ESPB4001ERBQ 100/cs 55721A-EU
without holster
ESRK4001Q Rocker switch, blade electrode, 3 m cord without holster 100/cs 55722A-EU

ESRK4001LQ Rocker switch, blade electrode, 5 m cord without holster 80/cs n/a

Page 5
Electrosurgical pencil with non-
stick PTFE-coated tips
Coated with PTFE, the same non-stick compound used in Teflon®
• The coating allows the electrode to be easily cleaned with a wet piece of gauze or sponge
instead of an abrasive scratch pad.
• Rounded edges prevent the RF current from concentrating too much energy in one area.
• All tips less than 7.62 cm in length feature ribbed insulation, allowing for easy tip changes,
even under wet conditions.

ESPB4002Q

PTFE non-stick coated tip, sterile1

Pack component
Item number Description Packaging
number
Push button, non-stick blade electrode, 3 m cord
ESPB4002Q 60/cs ESPB3002NSA-EU
with holster

Page 6
Electrosurgical
active electrodes
(tips)

Medline offers active electrodes for your


needs, either in a stainless-steel or non-stick
PTFE-coated version. These high-quality active
electrodes are manufactured to exacting
tolerances. All tips under 7.62 cm have ribbed
insulation for easy tip changes, even under wet
conditions. The standard 2.4 mm shafts fit most
electrosurgical pencils.

Page 7
ESE1550EU

ESE1552EU

Stainless-steel ESE1551XEU
ESE15516EU

electrodes,
single use, sterile ESE15526EU

Standard 2.4 mm shaft, designed to fit


most electrosurgical pencils

Stainless-steel electrodes, single use, sterile2

Pack component
Item number Description Packaging
number
ESE1550EU Ball electrode, 5 mm diameter, 5 cm length 10/cs ESE1550AEU-NS

ESE1552EU Needle electrode, 7 cm 10/cs 85511A-EU

ESE1551XEU Blade electrode, 7 cm 10/cs 85512A-EU

ESE15516EU Extended blade electrode, 15 cm 10/cs 85513-EU

ESE15526EU Extended needle electrode, 15 cm 10/cs 85515-EU

Tungsten loop electrodes


• For accurate and smooth cervical conisation

Item number Description Packaging

SP200-L31S Tungsten loop electrode, 10 x 10 mm 10/cs

SP200-L45S Tungsten loop electrode, 15 x 12 mm 10/cs

SP200-L37S Tungsten loop electrode, 20 x 12 mm 10/cs

SP200-L35S Tungsten loop electrode, 20 x 15 mm 10/cs

Page 8
Non-stick PTFE-coated
electrodes, single use, sterile
Coated with PTFE, the same non-stick compound used in Teflon
Ribbed insulation
• Standard 2.4 mm shaft designed to fit most electrosurgical pencils
• Easily cleaned with a wet piece of gauze or sponge (as opposed to an
abrasive scratch pad)
• Rounded blade edges to prevent the RF current from concentrating
too much energy in one area
• Ribbed insulation for easy tip changes, even under wet conditions
Rounded blade

ES0012AEU

ES0012AMEU

ES0013EU

ES0014AMEU

ES0014EU

ES0016EU

Non-stick PTFE-coated electrodes, single use, sterile3

Item number Description Packaging

ES0012AEU Blade electrode, 7 cm 12/cs

ES0012AMEU Blade electrode, extended insulation, 7 cm 12/cs

ES0013EU Needle electrode, 7 cm 12/cs

ES0014AMEU Blade electrode, extended insulation, 10 cm 12/cs

ES0014EU Blade electrode, 15 cm 12/cs

ES0016EU Needle electrode, 15 cm 12/cs

Page 9
Accessories

Electrosurgical accessories, such as tip cleaners and holsters, can be as vital to


a procedure as your generator. Safety holsters are recommended by nursing
associations like AfPP* for holding cautery pencils when they are not in use, and
can be invaluable in helping protect your patients and staff. To ensure that you
never run out of any electrosurgical products, you need a supplier that offers
quick turnaround time and outstanding service.

*AfPP standards and recommendations for safe perioperative practice in 2011 suggest that the active
electrode should be stored securely in a non-conductive container when not in use.

Electrosurgical tip cleaner


• For quick and easy cleaning of cautery tips during surgery
• Radiopaque
• Sturdy adhesive backing for secure storage anywhere with ease

Electrosurgical tip cleaner, sterile4

Pack component
Item number Description Packaging
number

TC-100 Cautery tip polisher, 5 x 5 cm 100/cs 118438-EU

Page 10
Service and support
Our guarantee
Medline stands for the quality of its electrosurgical products, regardless of the generator with
which they are used.

Guarantee and indemnification policy


Guarantee: Medline Industries, LP fully recognises its responsibilities as a manufacturer of
healthcare products and warrants that reasonable care was used in the manufacture of its
electrosurgical products. Medline will replace, at no charge, any electrosurgical products
that fail to meet Medline’s standards of workmanship, materials or design, although Medline
will not be responsible for damage after delivery due to accident, improper use or abuse, or
failure to follow instructions provided by Medline. Included in this policy are electrosurgical
generators, provided that any damage to such generators is proven to be solely caused by a
defective Medline electrosurgical product or the incompatibility of the Medline product with
the electrosurgical generator.

Indemnification: Medline shall defend, hold harmless and indemnify the account for any and all
losses, claims, judgments and expenses (including but not limited to attorneys’ fees) relating to
any claim of personal injury arising from or caused by any defect in the Medline electrosurgical
product, provided that each of the following four conditions is satisfied:

(A) Such personal injury occurs during a surgical procedure in which the grounding pad is used
in accordance with Medline’s instructions for use and only when used with an active accessory
and electrosurgical generator with a functioning patient-contact monitoring system designed
for use with a split-style pad made by one of the following companies: Valleylab®, ConMed®,
Aspen, Bard®, Birtcher, NDM, ERBE® and Bovie Medical.

(B) The personal injury is not caused by the account’s negligence or intentional misconduct, or
as a result of a modification to any of the machines, pads or cable.

(C) The account notifies Medline of the occurrence within a reasonable time thereafter, and
has furnished prompt records of any and all claims of damage allegedly caused by defective
Medline electrosurgical products, sent by registered or certified mail addressed to Medline’s
office, Medline-Straße 1-3, 47533 Kleve, Germany, https://www.medline.eu/uk/contact-us.

(D) Medline controls the defence and resolution of any such claims, and the account fully
cooperates in such defence and resolution.

This agreement shall be valid and binding upon its execution by the account and Medline.
This agreement constitutes the final and complete agreement between the account and
Medline, and it terminates all prior written or oral agreements and understandings as to
this agreement’s subject matter. German law will apply in interpreting and enforcing this
agreement.

Page 11
OR Necessities
Separate sterile pack components

Safety and
Standardisation Surgical Clipper
Designed for safety, convenience and efficiency

Trusted
preoperative
hair removal

For more information on our products, please contact


your account manager or visit us at www.medline.eu/uk

Medline Industries Ltd Medline Ireland Ltd FOLLOW US


3rd Floor 1 Grant’s Row
Quayside Wilderspool Business Park Mount Street Lower
Greenalls Avenue Dublin 2
Warrington WA4 6HL Ireland
United Kingdom Tel.: +353 1 691 73 06
Tel.: +44 844 334 5237
www.medline.eu/uk www.medline.eu/ie
[email protected] [email protected]

1
These products are class IIb sterile medical devices intended to be used by healthcare professionals. MedNet GmbH
Borkstraße 10 0482 (Medcert GmbH)
Before use, consult instructions and precautions on the corresponding labelling. Latex free 48163 Münster, Germany

2
These products are class IIb sterile medical devices intended to be used by healthcare professionals. Shanghai International Holding Corp. GmbH (Europe)
Eiffestraße 80 0120 (SGS UK Limited)
Before use, consult instructions and precautions on the corresponding labelling. Latex free 20537 Hamburg, Germany

3
These products are class IIb sterile medical devices intended to be used by healthcare professionals. Emergo Europe
Prinsessegracht 20 0413 (Intertek Semko AB)
Before use, consult instructions and precautions on the corresponding labelling. Latex free 2514 AP The Hague, The Netherlands

4
This product is a class I sterile medical device intended to be used by healthcare professionals. Medline International France SAS
5 Rue Charles Lindbergh 0086 (BSI)
Before use, consult instructions and precautions on the corresponding labelling. Latex free 44110 Châteaubriant, France

All rights reserved. We reserve the right to correct errors that may have occurred.
© 2022 Medline Industries, LP. Medline is a registered trademark of Medline Industries, LP. ML250_EN 06/2022