You are on page 1/ 1

X3&X3A Quick Installation Guide

Precautions
To ensure human safety and device security, comply with all the safety precautions marked on the device and instructed in the product document.
The "CAUTION", "WARNING", and "DANGER" marks in the product document do not cover all the safety precautions that must be obeyed. They are supplements to the
safety precautions.
Installation and maintenance personnel must be trained to perform operations correctly and safely.
To prevent device damage or personal injury, ensure that all devices are grounded before being powered on.
Do not look into optical ports without eye protection. Otherwise, eyes may be hurt by laser beams.
Always wear ESD gloves or an ESD wrist strap prior to contact with devices or before handling boards, subcards, or IC chips to prevent damage to sensitive components due to electrostatic
discharge from the human body. Ensure that the ESD wrist strap is properly grounded.

This document is developed to provide concise and quick instructions for device hardware installation. For details about the installation,
NOTE see the corresponding installation guide.

Introduction to the Device


X3(DC) X3(AC) X3A

Handle !
Fan
32-55
KG(70
-121
lbs)
FAN
RUN

RUN
4
5

MPU Air intake Fan module


MPU

MPU
ALM

4 AUX
CONSOLE
ACT

RUN
5 CF CARD OFL

vent
LINK RESET
ACT
MPU

ALM
OFL CFS
ACT RUN

cage cover
CONSOLE

MPU
AUX
CF CARD OFL
ALM
FAN STATUS
LINK RESET ACT
ACT
CONSOLE ETH
AUX
OFL CFS CF CARD BITS1

LPU
RUN OFL BITS0

RUN

OFL
LINK RESET

3
ACT
MPU

ALM
OFL CFS
ACT

LPU
CONSOLE ETH
AUX

RX
CF CARD

STA
BITS1

TX
OFL

0
RESET BITS0

TU
LINK
ACT

S
ETH
OFL CFS BITS1

2
BITS0

LPU

L/A

LPU
RUN

OFL
RX

STA
TX
ETH

0
LPU

TU
BITS1

Air intake

RUN

OFL

S
BITS0

Air intake LPU

RX

STA
Air intake

TX
0

TU
L/A
LPU

S
RX

STA
TX
0
RUN

OFL

TU
S
1

L/A
RX

STA

RX
TX

STA
L/A

TX
0

Front cable

0
TU

TU
S

S
RX

STA
TX
1

TU
vent

S
Cable tray
L/A

L/A
vent vent ESD jack
RX

STA
TX

L/A
ESD
0

TU
S

PSU2

MPU
L/A

ESD CONSOLE

tray
AUX
LINK
ACT

Power module MPU


RESET RUN
OFL ACT ALM OFL

PSU1

MPU
OFF
ON
CONSOLE MGMT-ETH
AUX TOD
LINK CLK
ACT
RESET RUN
OFL ACT ALM OFL

OFF
MGMT-ETH

ON
TOD
CLK

Rack-mounting ear

Handle Handle
!
ESD
32-55
KG(70
-121
lbs)
Air exhaust vent
Ground terminal
Air Filter

Air Filter
Power module
NEG(-)

STATUS -48V 一 -60V;42A


PWR 1
STATUS

Air Filter
RUN
ON RTN(+)
RUN
ON
ON
OFF

OFF OFF
NEG(-) ALM

Air filter Air filter


ALM

PWR 2

Air filter
-48V 一 -60V;42A

RTN(+) NEG(-)
ON RTN(+) PFM

-48V- 60V
RUN
ON
OFF

Per input
OFF

ALM

Fan Ground terminal current,


earth connection
High touch and / or telecommun
essential
ication RUN

Power modul
before supply

! ON

Ground terminal
connections

Fan
network
大接触电流!通信网络之前必须先接地
OFF
WARNING
在连接电源和 ALM

RTN(+) NEG(-)
PFM

-48V- 60V
Per input
Slot Name Slot ID Remarks
Allow at least 75 mm (2.95 in.) of clearance around the air intake vent of the device,
LPU slot 1~3 These slots are used to house LPUs. and 1 U of clearances between chassis.

MPU slot 4~5 These slots are used to house MPUs. CAUTION Allow at least 350 mm (13.78 in.) of clearance around the air filter of the NE40E-X3A for
maintenance.
The DC X3 and AC X3 models use different chassis but share the same
slot numbering and layout.

01
Cabinet Requirements
Installing the device into a cabinet
Installing the chassis in a Huawei N68E
cabinet is recommended. 1 Install guide rails 2 Install floating nuts.
The depth of the cabinet is greater than
800 mm (31.50 in.).
The side the top of which has
The depth of the cabinet is greater than ground screws is the rear of a
800 mm (31.50 in.). Huawei cabinet.
The depth of the cabinet is greater than The bottom of each guide rail must
be aligned with the scale on the
800 mm (31.50 in.). mounting bar.
NOTE The floating nuts must be installed
L
securely.
Ensure that the clearance between
the guide rails and the cabinet
bottom is at least 1U (1.75 in.).

M5
30 kgf·cm(26.04 lbf·in.)

a.X3(DC)
1U(1.75 in.)

800mm (31.50 in.)


10

3 (Optional)Install mounting ears and cable trays

a. Installing mounting ears frontwards c. Installing cable trays 4 Install the device in the cabinet b.X3(AC)
M4
M4 12 kgf·cm(10.42 lbf·in.) M6 13
12 kgf·cm(10.42 lbf·in.)
30 kgf·cm(26.04 lbf·in.)
2
4 4
RUN
5 RUN
5
MPU

ALM
MPU

ALM
ACT
CONSOLE ACT
AUX

2
CONSOLE
CF CARD OFL AUX
LINK RESET CF CARD OFL
ACT LINK RESET

3
ACT
OFL CFS
RUN OFL CFS
RUN

3
MPU

ALM

3
MPU

ALM
ACT
CONSOLE ETH ACT
AUX CONSOLE
CF CARD OFL BITS1 AUX ETH
LINK RESET BITS0 CF CARD OFL BITS1
ACT LINK RESET BITS0
ACT
OFL CFS
OFL CFS

1
ETH
BITS1 ETH

2
BITS0 BITS1

2
BITS0

1 1

ESD 1 ESD
PSU2

PSU2
PSU1

PSU1
OFF

OFF
ON

ON
OFF

OFF
ON

ON

1 4
RUN
5
MPU

ALM
ACT
CONSOLE
AUX
CF CARD OFL
LINK RESET

b.X3A
ACT

OFL CFS
RUN

2
3
MPU

ALM
ACT
CONSOLE ETH
AUX
CF CARD OFL BITS1
LINK RESET BITS0
ACT

OFL CFS

ETH
BITS1

2
BITS0

b. Installing mounting ears frontwards


LPU
RUN

OFL
RX0

STAT
TX

US

1
L/A
RX0

STAT
TX

US

ESD
L/A

PSU2
PSU1

●If the distance (L) from the mounting rail to the inner side of
OFF
ON

M4
OFF
ON

the chassis' front door is in the range from 115 mm (4.53 in.)
12 kgf·cm(10.42 lbf·in.)
to 125 mm (4.92 in.), install the mounting ears frontwards. If 10
2 the distance (L) from the mounting rail to the inner side of the 7
chassis' front door is in the range from 90 mm (3.54 in.) to 100
CAUTION mm (3.94 in.), install the mounting ears backwards.
4
RUN
5
MPU

ALM
ACT

2
CONSOLE
AUX
CF CARD OFL
LINK RESET
ACT

OFL CFS
RUN

3
MPU

ALM
ACT
CONSOLE ETH
AUX
CF CARD OFL BITS1
LINK RESET BITS0
ACT

OFL CFS

1 ●The air inlet and outlet of the equipment must be kept


ETH
BITS1

2
BITS0

unobstructed, avoiding one device's outlet facing another


1

ESD
PSU2

device's inlet, and also avoiding direct air conditioning blowing


PSU1

OFF
ON

on the equipment.
OFF
ON

02 Installing PGND cables


03 Installing power cables

X3 X3A
Install power cables when the power is off to avoid personal injury.
To avoid device damage or personal injury, ensure that the device is grounded
DANGER before being powered on.

M8 M8
X3(AC) X3(DC)
80 kgf·cm(69.44 lbf·in.) 80 kgf·cm(69.44 lbf·in.)

1 TO: 1
1
X-XXX-X-X

3 M6
OFF

OFF
ON

ON

50 kgf·cm(43.40 lbf·in.)

3
X-XXX-X-X

2
TO:

M6
50 kgf·cm(43.40 lbf·in.) ESD
Air Filter

NEG(-)

STATUS -48V 一 -60V;42A


PWR 1

ESD

M6
Air Filter

RTN(+)

!
ON
ON
OFF

RUN
OFF

4 ALM
NEG(-) NEG(-)
32-55KG(70-1
21 lbs)
RUN
5 -48V 一 -60V;42A
PWR 2
STATUS PWR 1
-48V 一 -60V;42A
MPU

ALM
ACT
CONSOLE
AUX
CF CARD OFL
LINK RESET RTN(+)
ACT ON
ON
OFF

RUN
OFL CFS OFF
RUN RTN(+)
ON

50 kgf·cm(43.40 lbf·in.)
Air Filter

RUN
ON

3
RUN
OFF
MPU

ALM ALM
ON OFF
OFF ACT
CONSOLE ETH
ALM AUX NEG(-)
CF CARD OFL BITS1 ALM
ESD LINK RESET BITS0
ACT

PWR 2
Air Filter

OFL CFS
-48V 一 -60V;42A

Air Filter
RTN(+) NEG(-)

NEG(-)

PFM
PWR 1
-48V- 60V

STATUS
Per input

-48V 一 -60V;42A
ETH
BITS1

2
BITS0
ON RTN(+)
ON

RUN
OFF

ON RTN(+)
RUN
ON

OFF
OFF

NEG(-)
ALM
RUN OFF
LPU

-48V 一 -60V;42A
PWR 2
RUN

OFL

ON
OFF ALM
ALM
ON RTN(+)
ON

RUN
OFF

RX0

STAT
TX

OFF
US

ALM

1
RTN(+) NEG(-)

PFM
-48V- 60V
Per input

L/A
RX0

STAT
TX

US

ESD
L/A

PSU2
PSU1

OFF
ON
OFF
ON

To facilitate later maintenance, do not let


power cables obstruct the air filter.

04
CAUTION
Installing Boards and Subcards X3A(AC) X3A(DC)

Installing a board Installing a subcard


2 M6
50 kgf·cm(43.40 lbf·in.)

M3
M3
6 kgf·cm(5.20 lbf·in.)
6 kgf·cm(5.20 lbf·in.)
RX

STA
TX
0

TU
S

2
L/A

3
2

4 !
RUN
5
MPU

ALM
32-55KG(
ACT
CONSOLE 70-121
AUX lbs)
CF CARD OFL
LINK RESET
ACT

OFL CFS
RUN

3
MPU

ALM

4
!
ACT
CONSOLE ETH

5
AUX
CF CARD OFL BITS1
BITS0 RUN
LINK RESET
ACT
MPU

ALM
OFL CFS
Air Filter

ACT 32-55KG(
CONSOLE
AUX
CF CARD FAULT 70-121
ACT
LINK RESET
OFL
INPUT OUTPUT lbs)

ETH
BITS1 OFL CFS
RUN
OFF ON
2
BITS0

3
MPU

ALM
ACT
CONSOLE ETH
AUX
CF CARD BITS1
AC
~100-240V 50/60Hz 16A

OFL BITS0
RESET
PSU3000-
LINK
ACT

OFL CFS
Air Filter

RUN
ON
ETH OFF

1
BITS1 ALM
2
BITS0

FAULT
INPUT OUTPUT
RTN(+) NEG(-)

PFM
-48V- 60V
Per input

OFF ON

1
ESD
PSU2

1
1 AC
~100-240V 50/60Hz 16A

PSU3000-
LPU

RUN
RUN

OFL

ON
OFF
PSU1

ALM
OFF
ON

ESD
PSU2

RTN(+) NEG(-)

PFM
-48V- 60V
Per input
OFF
ON

RX

STA
TX
PSU1

TUS
OFF
ON

L/A
LPU
RUN

OFL

OFF
ON

05 Installing network cables


06 Installing optical fibers

2
1

100mm (3.94 in.)


RX
TX
0
L/A

2
45
RUN
MPU

ALM
ACT
CONSOLE
AUX
CF CARD OFL
LINK RESET
ACT

OFL CFS
RUN

3
MPU

ALM
ACT
CONSOLE ETH
AUX
CF CARD OFL BITS1
LINK RESET BITS0
ACT

OFL CFS

ETH
BITS1

2
BITS0
LPU
RUN

OFL

1
STATUS

1
STATUS

ESD
PSU2
PSU1

OFF
ON
OFF
ON

45 45
RUN RUN
MPU

MPU

ALM ALM
ACT ACT
CONSOLE CONSOLE
AUX AUX
CF CARD OFL CF CARD OFL
LINK RESET LINK RESET
ACT ACT

OFL CFS OFL CFS


RUN RUN

3 3
MPU

MPU

ALM ALM
ACT ACT
CONSOLE ETH CONSOLE ETH
AUX AUX
CF CARD OFL BITS1 CF CARD OFL BITS1
LINK RESET BITS0 LINK RESET BITS0
ACT ACT

OFL CFS OFL CFS

ETH ETH
BITS1 BITS1

2 2
BITS0 BITS0

07
LPU

LPU
RUN

OFL

RUN

OFL
RX0

RX0
STATUS

STATUS
TX

TX

1 1
L/A

L/A
LPU

LPU
RX0

RX0
STATUS

STATUS
TX

RUN

OFL

TX

RUN

OFL
RX0

RX0
STATUS

STATUS
TX

TX

ESD ESD
L/A

L/A
PSU2

PSU2

Checking installation
L/A

L/A
RX0

RX0
STATUS

STATUS
TX

TX
PSU1

PSU1
L/A

L/A
OFF

OFF
ON

ON
OFF

OFF
ON

ON

NO

1
All bolts and screws are firmly fastened, especially on electrical connections. Flat and
spring washers are used with each bolt, and spring washers are placed on the top of flat
Check Item
081. Before a power-on check, ensure that the switch is Off and the input voltage is within the normal range.
Performing a power-on check

washers. 2. Turn on external power supply and check whether the output voltage meets power supply requirements.
All assembled PGND cables are copper-based with proper wire diameters. There is no 3. Check whether the voltage of the input terminal on the power module is within the normal range.
2 switch, fuse, or disconnection on the cables.
X3(DC) -38.4V DC to -72V DC
All ground cables, AC input cables, and intra-cabinet cables are connected correctly
X3A(DC) -40V DC to -72V DC
3 according to the wiring diagram, and all screws are tightened. The input and output
X3&X3A(AC) 180V AC to 264V AC
cables are not short-circuited.
4 Any redundant parts of power cables or PGND cables are trimmed off and not coiled. 4. Turn on the power supply switch on the power module to supply power to the device. Check whether the
power supply is normal.
5 The terminals at both ends of each power cable or PGND cable are crimped securely. 5. Check the status of device indicators.
The wiring terminals on cables are wrapped tightly using PVC insulation tapes or heat
6 shrink tubes. Component Indicator Normal Status
7 The wiring terminals with heat shrink tubes are heated using a heat gun. Power module RUN Steady green
8 Flat and spring washers are properly installed on each bolt of a wiring terminal. Fan module STATUS Blinking every one second
9 All cables, especially the cables in the lower area of the cabinet, are securely connected. MPU RUN Blinking every two seconds
10 Power and ground cables are bound separately from other cables. LPU RUN Blinking every two seconds

11 The cable layout accounts for easy maintenance and expansion in the future.
12 The labels at both ends of each cable are correct, legible, and complet.
Copyright © Huawei Technologies Co., Ltd. 2017. All rights reserved.