PCSID1424A

New wide lineup of SkyAir series.


Product Lineup
Series 09 13 18 21
Btu/h 9,200 13,000 18,000/17,700* 1
21,000
kW 2.7 3.8 5.3/5.2*1 6.2

CEILING MOUNTED
CASSETTE TYPE
Round Flow

Indoor unit FCNQ13MV14 FCNQ18MV14 FCNQ21MV14


Outdoor unit RNQ13MV14 RNQ18MV14 RNQ21MV14

CEILING SUSPENDED TYPE

Indoor unit FHNQ13MV14 FHNQ18MV14 FHNQ21MV14


Outdoor unit RNQ13MV14 RNQ18MV14 RNQ21MV14
Pair

DUCT LOW STATIC


CONNECTION PRESSURE
TYPE

Indoor unit FDBNQ09MV14 FDBNQ13MV14 FDBNQ18MV14 FDBNQ21MV14


Outdoor unit RNQ09MV14 RNQ13MV14 RNQ18MV14 RNQ21MV14

MIDDLE STATIC
PRESSURE
TYPE

Indoor unit
Outdoor unit

OUTDOOR UNIT

Outdoor unit RNQ09MV14 RNQ13MV14 RNQ18MV14 RNQ21MV14


Note : *1Applicable to FDBNQ series. *2Applicable to FHNQ series. *3Applicable to FDMNQ series.

1
26 30 36 42 48
26,000 30,000 36,000/35,000* 2
42,600/42,000* 2,3
48,000
7.6 8.8 10.6/10.4*2 12.5/12.3*2,3 14.1

FCNQ26MV14 FCNQ30MV14 FCNQ36MV14 FCNQ42MV14 FCNQ48MV14


RNQ26MV14 RNQ26MY14 RNQ30MY14 RNQ36MY14 RNQ48MY14

FHNQ26MV14 FHNQ30MV14 FHNQ36MV14 FHNQ42MV14 FHNQ48MV14


RNQ26MV14 RNQ26MY14 RNQ30MY14 RNQ36MY14 RNQ42MY14 RNQ48MY14

FDMNQ26MV14 FDMNQ30MV14 FDMNQ36MV14 FDMNQ42MV14 FDMNQ48MV14


RNQ26MV14 RNQ26MY14 RNQ30MY14 RNQ36MY14 RNQ42MY14 RNQ48MY14

RNQ26MV14 RNQ26MY14 RNQ30MY14 RNQ36MY14 RNQ42MY14 RNQ48MY14

2
CEILING MOUNTED CASSETTE TYPE Round Flow

Cassette air conditioner with 360°


uniform airflow sets the standard
FCNQ13/18/21/26/30/36/42/48MV14

Sound level

43/32dB(A) High
FCNQ36M
Low

Option (220V)
Accessory required for indoor unit.

Wired LCD remote controller

BRC1C61
Note: Remote controller cable not
included. Cables must be procured
locally.

Navigation Remote Controller


(Wired Remote Controller)

BRC1E62
Note: Remote controller cable not
included. Cables must be procured
locally.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

BRC7F633F

Signal receiver unit


(Installed type)

Wireless remote controller and signal


receiver unit are sold as a set.

Features
Comfort Remote controller Cleanliness Work & Servicing Control features Options Others
Ceiling soiling prevention

Group control by 1 remote


Drain pump mechanism
Off timer (programmed)

DIII-NET communication
Swing pattern selection

High ceiling application

Weekly schedule timer


Switchable fan speed

Anti corrosion treated


Central remote control
Anti-bacterial air filter
temperature-sensors

Control by 2 remote

High-efficiency filter
Setpoint auto reset

Fresh air intake kit


Setpoint range set

Ultra long-life filter


External command
Programme "Dry"

heat exchangers
Pre charged for

Pre charged for

Interlock control
Two selectable

Long-life filter
On/Off timer

Auto-restart
Auto swing

up to 15 m

up to 10 m

controllers
Filter sign

controller

standard
(2 step)

control

• • • • • *1 *2 *2 *2 *2 *3
• • *4 *5
• • • • • • • • • • • • • *6

*1Applicable when wired remote controller is used *4Applicable to RNQ30-48M outdoor units
*2Applicable when BRC1E62 is used *5Applicable to RNQ13-26M outdoor units
*3Applicable when BRC1C61 is used *6For the outdoor units

3
Avoids uneven temperature and discomfort caused by drafts.

Comfort enhanced by Round Flow!


360° airflow Air movement is gentle with Round Flow

With uniform temperature Enhanced Comfort


distribution 360° airflow can
maintain comfort
even if air discharge
Airflow
speed is lower.
distribution
Creates uniform
comfort throughout
the space If you raise the set
temperature by 1 to
1.5°C,and velocity is
decreased by 25%,
Greater comfort you still obtain the same
Improved energy saving feeling temperature and
comfort.

Adapts easily to the installation space.


Because air flows out from corner outlets, comfort spreads more widely.
Typical flow patterns There are a total of 23 flow patterns.

L-shaped Opposite
All-round flow 3-way flow
2-way flow 2-way flow

(E.g., installed in (E.g., installed (E.g., installed in (E.g., installed in


middle of ceiling) near a wall) a corner) a long room)
4-way flow also possible.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to
close each unused outlet.
Operation sound increases when using 2-way or 3-way flow.

Grime prevention and bactericidal coating: Make cleaning easier.


External panels are treated with a coating that
repels dirt. Treated
surface
Untreated
surface
To prevent dirt sticking to the
external panels, they have Resists
soiling
been coated with a surface • Condition after exposure
Grimy to the smoke of 600
treatment. surface cigarettes in 1 m3
enclosed space.

Non-flocking flaps Filter has anti-mould and bactericidal treatment


Condensation does not easily form on and dirt does not Prevents mould and microorganisms growing out of the dust and
cling to non-flocking flaps. moisture that adheres to the filters.
It is easy to clean.

4
CEILING MOUNTED CASSETTE TYPE Round Flow

Fine square panels Compact body and quiet operation


Panel size is same for all models, FCNQ13-48M. dB(A)
It is easy to maintain a neat appearance when Indoor unit High Low
multiple units are installed. 13/18M 31 28
21/26M 35 28 Note : Anechoic chamber
mm 95 conversion value, measured
950 0m
m Same for 30/36M 43 32 according to JIS parameters
and criteria. During operation
all models 42M 44 34 these values are somewhat
higher owing to ambient
48M 44 36 conditions.

Optimal comfort and convenience Quick and easy to install


assured by 2 air discharge modes Just 256 mm high. Installable in tight
ceiling spaces (13-26M)
Note: Air direction is set to the standard position when the unit is shipped from the factory.
The position can be changed from the remote controller.

Air direction Standard setting Setting to prevent soiling of ceiling* 256 mm *1 266 mm *2
Standard position to Recommended for shops with
Desired light coloured ceilings that
situation prevent draft. must be kept spotless.
*1 298 mm high with 30-48M
*2 308 mm high with 30-48M
Auto-swing Auto-swing between Auto-swing between
15° and 60° 25° and 60°
Easy height adjustment
5-levels Each corner of the unit has an Adjuster Pocket that
air direction Settable to 5 different Settable to 5 different lets you easily adjust the unit's suspended height.
setting levels between 15° and 60° levels between 25° and 60°
Note: If the wireless remote control option is installed, a light receptor
unit is housed in one of the adjuster pockets.
Auto air The air direction is set automatically to the
memorised position of the previous air direction.
direction control All models can be installed without
*Closing of the corner discharge outlets is recommended. using lifter because of the light weight.

Suitable for high ceilings Installable in


Even in spaces with high ceilings, a comfortable airflow is carried down to any direction
the floor level. Since the orientation of
Criteria for ceiling height and number of air discharge outlets the intake grill can be
(Ceiling height is reference value) adjusted after installing,
the direction of the intake
Number of air discharge outlets used
grill lines can be unified
13-26M 30-48M when multiple units
All round 4-way 3-way 2-way All round 4-way 3-way 2-way are installed.
flow flow flow flow flow flow flow flow
Standard 2.7 m 3.1 m 3.0 m 3.5 m 3.2 m 3.4 m 3.6 m 4.2 m
Ceiling 3.0 m 3.4 m 3.3 m 3.8 m 3.6 m 3.9 m 4.0 m 4.2 m
High ceiling
height
High ceiling 3.5 m 4.0 m 3.5 m - 4.2 m 4.5 m 4.2 m - Drain pump is equipped as standard
Note: Factory settings are for standard ceiling height and all-round flow. accessory with 850 mm lift.
High ceiling settings (1) and (2) are set with the remote controller by field setting.

Two selectable temperature-sensors 850 mm


Both indoor unit and wired remote controller (option) contain temperature-
sensors. Temperature sensing can be set at the unit or, to further improve 175 mm
comfort level, closer to the target area at the wired remote control. This
feature must be set during commissioning by the technicians.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Transparent drain socket
Because the drain socket is
Switchable fan speed: High/Low transparent, after the drain piping
has been installed, it is easy to
High setting provides maximum reach while low
check if the drain come out
setting minimises drafts.
through the socket.

On/Off timer Connection to a centralised control


Operation starts when the preset time of the ON timer elapses and stops system is available without option
when the preset time of the OFF timer elapses.

5
OUTDOOR UNIT

RNQ09MV14 RNQ18MV14 RNQ26MV14 RNQ36MY14


RNQ13MV14 RNQ21MV14 RNQ26MY14 RNQ36MY14
RNQ42MY14
RNQ48MY14

Quiet Operation Installation and


Fitted with Super Aero Grille maintenance
(Applies to RNQ30-48M)

To suppress turbulence Pre charged for up to 15 metres (Applies to RNQ30-48M)


and achieve quiet If refrigerant piping length does not exceed 10m (RNQ09-26M), 15m
operation, the curved ribs (RNQ30-48M), there is no need for on-site gas charging.
of the grille are optimised
to meet the outflow of air.
Allowed refrigerant piping length and level difference

RNQ09/13M RNQ18/21M RNQ26M RNQ30-48M

Pre charged1 10 m 15 m
30 m 50 m
Max. length 30 m (Equivalent length (Equivalent length
50m) 70m)
Max. level
difference 10 m 15 m 20 m 30 m

Note:
1
Additional refrigerant charging is required if the refrigerant pipe is longer than the
length.
Equipped with scroll compressor
for quiet operation 4-direction piping offers greater
(Applies to RNQ42-48M)
layout freedom (Applies to RNQ30-48M)
Smooth running, minimal The outer panel for the piping connection
vibration, low operating part of the front, right side and backside can
sound. be removed and is easier for
post-installation piping work.
Separation
available

Durability
As the bottom frame is subject to corrosion,
Operation sound
(In case of RNQ09-21M:220-240 V, RNQ26-36M:220 V/380 V,
corrosion-proof galvarium steel plate is adopted
240 V/415 V, RNQ42-48M:380 V, 415 V) dB(A) to enhance the durability.
Outdoor unit Sound level
RNQ09MV14 48
Heat exchange fins provided with anti-corrosion
RNQ13MV14 49
treatment (Applies to RNQ09-26, 36-48M)
RNQ18MV14 51
To achieve increased durability by improved resistance to salt corrosion and
RNQ21MV14 52
atmospheric pollution, Anti corrosion treated heat exchangers (with special
RNQ26MV14/RNQ26MY14 54 acryl pretreatment) are used for the heat exchanger of the outdoor unit.
RNQ30MV14/RNQ30MY14 55 Construction
RNQ36MV14/RNQ36MY14 54 Non-treated fin Aluminium
Hydrophilic film
RNQ42MY14 56 Anti corrosion
treated heat Aluminium
Corrosion resistant
RNQ48MY14 58 exchangers acrylic resin

10
Simple system provides a diverse assortment of control modes.
Control Applicable
Wired remote controller Wireless remote controller
pattern model

Control by 1
remote (Basic system)
controller FCNQ Non-polar, double-core Signal receiver unit installed
(max. wiring length 500 m) on indoor unit

For control from Control by 1 wireless remote


Control by 2 2 locations such FDBNQ controller and 1 wired remote
remote as in room and controller (See note 2, 3)
controllers control room, Connects 2 wired remote Signal receiver unit installed
exits, etc. controllers (See note 1) on indoor unit
FDMNQ

For
Group simultaneous
control control of up to
16 indoor units. Automatic address setting function Automatic address setting function
Signal receiver unit installed
on 1 indoor unit
Operation and
surveillance is
carried out using
Control by the contact signal
external from the operation
command control box in the
Optional wiring adaptor for Optional wiring adaptor for
building
surveillance electrical appendices is necessary electrical appendices is necessary
(security) room.

Central remote controller (option) Central remote controller (option)


Centralised
control of up to
Centralised 64 indoor
remote groups from
control remote location
up to 1 kilometer
away. FCNQ only

Heat Reclaim Heat Reclaim


Ventilator Ventilator
Link by remote
controller group
control. Can be operated simultaneously Can be operated simultaneously
or independently by remote controller by remote controller
(set by ventilation mode) (set by ventilation mode)
Interlock
control Central remote controller (option) Central remote controller (option)
with Heat
Reclaim
Ventilator Zone link control
by centralised Heat Reclaim Heat Reclaim
Ventilator Ventilator
control.
Heat Reclaim Ventilator for indoor units within Heat Reclaim Ventilator for indoor units within a
a zone are operated by interlocking Can also zone are operated by interlocking
be operated independently by remote
controller.

Note: 1BRC1E62 can connect to BRC1E62 only.


2
It is not possible to use two wireless remote controllers.
3
BRC1E62 cannot connect to wireless remote controller.

Easily adaptable to large-scale, high-function, FCNQ series only


centralised remote control system.
Central remote controller Unified on/off controller Schedule timer
DCS601C51 (Option)
DCS302CA61 (Option) DCS301BA61 (Option) DST301BA61 (Option)

Centralised control, with setting as Centralised control of on/off by Unified control of weekly schedule With its high functionality, the full
simple as it is with a standard group or all at once for up to 256 for up to 1,024 indoor units. colour “all-in-one” graphic controller
remote controller, of up to 64 groups indoor units. Schedule timer sets on/off time in 1 minute units facilitates management of SkyAir
(1,024 indoor units) is possible. to be executed twice a day for a week at a time. System in a variety of ways.

11
LCD REMOTE CONTROLLER Optional accessory

Easy-to-read LCD remote controller allows various system


Remote controller options are shown on the page introducing each indoor unit model.

Navigation Remote Controller


(Wired Remote Controller BRC1E62)
NEW This simple, modern designed remote controller with fresh
white colour matches your interior design. Operation is
much easier and smoother, just follow the indications on
the navigation remote controller.

Clear Display
Dot matrix display Backlight
A combination of fine dots display
enables various icons.
Large text display is easy to
see.

Energy saving
NEW Setpoint auto reset NEW Setpoint range set
- Even if the set temperature is changed, it returns to the preset temperature - Saves energy by limiting the
after apreset period of time. min. and max. set temperature.
- Period selectable from 30min/60min/90min/120min. - Avoids excessive heating or
Restaurant sample cooling.
Restaurant opened Full tables at lunchtime After 30 minutes* - This function is convenient when
Temperature is set to 27ºC Then is lowered to 24ºC for Automatically returns to preset the remote controller is installed
crowded room temperature (27ºC)
Returns to at a place where any number of
27 °C 24 °C 27 °C
automatically
people may operate it.

*Setting possible for after 30, 60, 90, and 120

Off timer (programmed)


minutes.

- Sets and saves setting for an increment of time that automatically turns off air
conditioner after a preset period of time for each time operation starts.
- Period can be preset from 30 to 180 minutes in10-minute increments.

Convenience
Weekly schedule Multilingual display
- 5 actions per day can be scheduled for each day Display is available in 11
of the week. languages.
- The holiday function will disable schedule timer (English, German, French, Spanish,
for the days that have been set as holiday. Italian, Portuguese, Greek, Dutch,
Russian, Turkish, and Polish).
NEW - 3 independent schedules can be set.
(e.g. summer, winter, mid-season)

12
control configurations and can control multiple indoor units.
Wired LCD remote controller
Wired remote controller has
Easy to read because of large LCD screen.
built-in temperature-sensor
The rubber switch and the (Applies to wired remote controllers (BRC1C61/1E62))
oil-resistant plastic casing are Enables temperature sensing closer to target
adopted for durability. area for improved comfort. (When using remote
Only 17 mm thick. Can be control from another room, temperature-sensor in
indoor unit's air inlet must be selected.)
installed either recessed or
exposed.

Facilitates maintenance and repair


All initial settings can be set from the remote
controller. After interior construction is complete,
BRC1C61 ceiling mounted cassette type can be remotely set
without having to use stepladder access for
manual setting.
Setting contents: High ceiling use, air direction, filter type, address for
LCD wireless remote controller centralised control (group control address is set automatically).

Remote controller is equipped with model name


The wireless remote controller is and failure display functions. This facilitates
supplied in a set with a signal service in the unlikely event of a malfunction.
receiver. (Applies to wired remote controller (BRC1E62))
Signal receiver unit is contained
inside decoration panel or indoor
unit. Ceiling mounted cassette type shares
Shape of signal receiver unit common control with Heat Reclaim
differs according to the indoor Ventilator and the other Daikin
unit. air-conditioning units, thus simplifying
BRC7F633F
interlocking operations.
Signal receiver unit Easily adaptable to large-scale, high-function,
Wireless remote (For ceiling mounted Note: The signal receiver unit shown in the
controller
centralised remote control systems.
cassette type) photograph is for mounting inside
the decoration panel of the ceiling
Installing and connecting control wiring between
mounted cassette type. SkyAir and other Daikin air-conditioning equipment
is easy.

Wireless remote controller for each indoor unit type


CEILING MOUNTED CASSETTE TYPE BRC7F633F
CEILING SUSPENDED TYPE BRC7NU66
DUCT CONNECTION LOW STATIC PRESSURE TYPE BRC4C64
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE BRC4C64

LCD panel shows operating status in letters, numbers, and motion.


Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).
Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows
Programming time display
when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.

13
Abundance of functions that provide comfortable
air-conditioning in stores and offices.
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.

Comfort
Auto-swing High-ceiling application
Delivers comfortable The air flow direction can be Delivers air-conditioning comfort all the way down to the floor
air-conditioning to all areas, near fixed at your desited angle in air-conditioning zones with high ceilings.
to and far from the by the remote controller.
air-conditioner.

Swing pattern selection


(standard, ceiling soiling prevention)
You can freely set 2 air discharge setting by remote controller.

(1) Standard setting Note:When units are installed on high ceilings, depending on the model,
various restrictions concerning maximum height, air discharge direction,
and choice of options may apply.
(2) Ceiling soiling prevention
setting
Two selectable temperature-sensors
Temperature-sensors are included in the indoor unit and
optional wired remote controller. Temperature sensing closer
Switchable fan speed to target area is possible to further increase the comfort level.
High setting provides maximum reach while low setting Use the temperature-sensor in
minimises drafts. the indoor unit when controlling
air conditioning from another
room.

Programme "Dry" Note: Wireless remote controllers have no


temperature-sensor.
Dehumidification is microprocessor controlled to prevent
abrupt and uncomfortable changes in air temperature. Useful
for reducing uncomfortable humidity without uncomfortable
cooling of the room.

Remote Controller
Setpoint auto reset Off timer (programmed)
Even if the set temperature is changed, it returns to the preset Sets and saves setting for an increment of time that
temperature after a preset period of time. automatically turns off air conditioner after a preset period of
time for each time operation starts.

Setpoint range set


Saves energy by limiting the minimum and maximum set
On/Off timer
temperatures. Avoids excessive heating and cooling. Operation starts when the preset time of the ON timer elapses
and stops when the preset time of the OFF timer elapses.

Weekly schedule timer


Up to five operation ON/OFF settings can be programmed per
day for each day of the week. Not only can the time be set for
the operation ON setting, but also the temperature.

Cleanliness
Anti-bacterial air filter
The Air filter has a anti-bacterial treatment to help prevent the growth of bacteria and mould on it.

14
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.

Work and Servicing


Drain pump mechanism Filter sign
Steeper gradient realises more The filter sign warns you when it is time to clean the filter.
efficient condensate drainage. *When using a wired remote controller the sign is displayed in the LCD.
High-lift is especially useful for When using a wireless remote controller the filter sign lamp illuminates on
long lengths of drain piping. the signal receiver unit.

Pre charged for up to 15 metres Ceiling soiling prevention function


If refrigerant piping length does not exceed 15 m, there is no Daikin's innovative air discharge mechanism keeps airflow
need for on-site gas charging. away from the ceiling. Ceiling cleaning is less frequently
*Applicable to RNQ30-48M. required.
RNQ09-26M : 10 m

Long-life filter
Maintenance is not required for one year.
The filter is washable and can be reused.

Control features
Auto-restart External command control
If there is a power outage while the equipment is operating, Operation and surveillance is carried out using the contact
operations will restart in the same mode as before the power signal from the operation control box in the building
cut when electricity is restored. surveillance (security) room.
*An option is required.

Control by 2 remote controllers Central remote control


Using 2 remote controllers you can operate the equipment
Optional central remote controller enables centralised control of
locally or from a remote location.
up to 1024 indoor units (64 groups) from up to 1 kilometer away.
Note: When a wireless remote controller is used, remote control by two
remote controllers is not possible.
Interlock control
Enables interlocking control with external equipment such as
Group control by 1 remote controller Heat Reclaim Ventilator.
You can turn up to 16 indoor units on/off with a single remote
controller. (When using connected indoor units, the settings
DIII-NET communication standard
must all be the same and on/off will be simultaneous.)
Standardly equipped interface enables connection to
centralised control system without need of an adaptor.

Options
High-efficiency filter unit Fresh-air intake kit
Two types are available: 65% and 90% colorimetry. You can provide air-conditioning with fresh air from outside.
Convenient for places where a ventilation fan cannot be
installed.
Ultra long-life filter Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts
should, as required, be procured locally.
Requires no maintenance for about 4 years* (10,000h) in **Outside Air fan interlocked with air conditioning unit is necessary. Optional
stores and offices. PCB(KRP1C63)is required for interlocking.
*For dust concentration of 0.15 mg/m3 ***It is recommended that the volume of outdoor air introduced through the kit
is limited to 10% of the maximum airflow rate of the indoor unit. Introducing
higher quantities will increase the operating noise and may also influence
temperature sending.

Others
Anti corrosion treated heat exchangers
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated
heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
In high corrosive areas, regular maintenance needs to be carried out.

15
SPECIFICATIONS

CEILING MOUNTED CASSETTE TYPE


13 18 21 26 30 36 42 48
Indoor unit FCNQ13MV14 FCNQ18MV14 FCNQ21MV14 FCNQ26MV14 FCNQ30MV14 FCNQ36MV14 FCNQ42MV14 FCNQ48MV14
Model
Name V14 RNQ13MV14 RNQ18MV14 RNQ21MV14 RNQ26MV14 --------- --------- --------- ---------
Outdoor unit
Y14 --------- --------- --------- RNQ26MY14 RNQ30MY14 RNQ36MY14 RNQ42MY14 RNQ48MY14
Power supply V14 1 Phase, 220–240 V, 50 Hz ---------
Outdoor unit
Y14 --------- 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 kW 3.8 5.3 6.2 7.6 8.8 10.6 12.5 14.1
Btu/h 13,000 18,000 21,000 26,000 30,000 36,000 42,600 48,000
Power consumption Cooling1 kW 1.24 1.89 2.21 2.53 2.73 3.31 4.15 5.04
COP W/W 3.07 2.80 2.80 3.00 3.22 3.20 3.01 2.80
Indoor Colour Unit ----------
unit Decoration panel Fresh white
Airflow rate (H/L) m3/min 13/10 21/13.5 32/20 33/22.5
cfm 459/353 741/477 1,130/706 1,165/794
Sound level (H/L)3 dB(A) 31/28 35/28 43/32 44/34 44/36
Dimensions Unit mm 256X840X840 298X840X840
(HXWXD) Decoration panel mm 50X950X950
Machine Unit kg 19.5 21 24
weight Decoration panel kg 5.5
Certified Operation range °CWB 14 to 23 14 to 25
Outdoor Colour Ivory white
unit Compressor Type Hermetically sealed rotary type Hermetically sealed scroll type
Motor output kW 0.9 1.4 1.8 2.2 2.7 3.75 4.5
Refrigerant charge (R-410A) 1.2 1.4 1.5 2.0 1.9 3.2 2.7 3.2
kg (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m)
Sound level3 dB(A) 49 51 52 54 55 54 56 58
Dimensions (HXWXD) mm 550X765X285 595X845X300 735X825X300 990X940X320 1,345X900X320
Machine weight V14 36 40 49 56 --------- --------- --------- ---------
kg
Y14 --------- --------- --------- 56 74 103 107 111
Certified Operation range °CDB 19.4 to 46 21 to 46
Piping Liquid (Flare) mm o/ 6.4 o/ 9.5
connections Gas (Flare) mm o/ 12.7 o/ 15.9
Drain Indoor unit mm VP25 (I.Do/ 25XO.Do/ 32)
Outdoor unit mm o/ 18.0 (Hole) o/ 26.0 (Hole)
Max. interunit piping length m 30 50
30
(Equivalent length 50) (Equivalent length 70)
Max. installation level difference m 10 15 20 30
Heat insulation Both liquid and gas piping

CEILING SUSPENDED TYPE


13 18 21 26 30 36 42 48
Indoor unit FHNQ13MV14 FHNQ18MV14 FHNQ21MV14 FHNQ26MV14 FHNQ30MV14 FHNQ36MV14 FHNQ42MV14 FHNQ48MV14
Model
Name V14 RNQ13MV14 RNQ18MV14 RNQ21MV14 RNQ26MV14 --------- --------- --------- ---------
Outdoor unit
Y14 --------- --------- --------- RNQ26MY14 RNQ30MY14 RNQ36MY14 RNQ42MY14 RNQ48MY14
Power supply V14 1 Phase, 220–240 V, 50 Hz ---------
Outdoor unit
Y14 --------- 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 kW 3.8 5.3 6.2 7.6 8.8 10.4 12.3 14.1
Btu/h 13,000 18,000 21,000 26,000 30,000 35,000 42,000 48,000
Power consumption Cooling1 kW 1.58 2.04 2.38 2.65 3.07 3.64 4.51 5.51
COP W/W 2.40 2.60 2.60 2.87 2.86 2.73 2.56
Colour White
Indoor
Airflow rate (H/L) m3/min 16/- 22-23/19-20 26-27/22-23 38-40/23-25 42-44/24-26
unit
cfm 565/- 777-812/671-706 918-953/777-812 1,341-1,412/812-883 1,483-1,553/847-918
Sound level (H/L) (220 V)3 dB(A) 43/39 44/40 45/40 48/42 49/43
Dimensions (HXWXD) mm 195X960X680 195X1,160X680 195X1,400X680 195X1,590X680
Machine weight kg 24 26 32 35
Certified operation range °CWB 14 to 23 14 to 25
Colour Ivory white
Outdoor
Compressor Type Hermetically sealed rotary type Hermetically sealed scroll type
unit
Motor output kW 0.9 1.4 1.8 2.2 2.7 3.75 4.5
Refrigerant charge (R-410A) kg 1.2 1.4 1.5 2.0 1.9 3.2 2.7 3.2
(Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m)
Sound level3 dB(A) 49 51 52 54 55 54 56 58
Dimensions (HXWXD) mm 550X765X285 595X845X300 735X825X300 990X940X320 1,345X900X320
Machine weight V14 kg 36 40 49 56 --------- --------- --------- ---------
Y14 kg --------- --------- --------- 56 74 103 107 111
Certified operation range °CDB 19.4 to 46 21 to 46
Piping Liquid (Flare) mm o/ 6.4 o/ 9.5
connections Gas (Flare) mm o/ 12.7 o/ 15.9
Drain Indoor unit mm VP20 (I.Do/ 20XO.D o/ 26)
Outdoor unit mm o/ 18.0 (Hole) o/ 26.0 (Hole)
Max. interunit piping length 30 50
m 30
(Equivalent length 50) (Equivalent length 70)
Max. installation level difference m 10 15 20 30
Heat insulation Both liquid and gas piping

Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.

16
DIMENSIONS (Unit: mm)

CEILING MOUNTED CASSETTE TYPE

[FCNQ13-48MV14] [FCNQ13-48MV14] [FCNQ13-26MV14] [FCNQ30-48MV14]


B
Connection position Connection position
860~910(Ceiling opening space) (Note 4) 81 2x100=200 85 of branch duct 81 2x100=200 85 of branch duct
300
or less 710(Hanging bolt pitch) 950 Note 2 124 (round shape type) 160 (round shape type)
9 420 8 C/L 16-M4 Hole C/L 16-M4 Hole
Pipe Connection

67
160
160
860~910(Ceiling opening space) (Note 4)
Side

780(Hanging bolt pitch)

167
93
95
110
124

29
95
157 157
Connection position Connection position

950
350 350 of branch duct
C of branch duct
(square-shaped type) (square-shaped type)
B arrow view B arrow view
6
Drain Connection
Side
7 [FCNQ13-26MV14] [FCNQ30-48MV14]
420
A arrow view 160
160 167
Connection position Connection position
of branch duct 124 of branch duct 93 67
(square-shaped type) 109 (square-shaped type) 95
[FCNQ13-26MV14] [FCNQ13-26MV14] 95
20-M4 20-M4 29
16-M4 Prepared hole Prepared hole Prepared hole
55 840 55 Connection position
Adjustable(0~675)

55 840 55
20-M4 Prepared hole

2x100=200 80
80
340 of branch duct 3 81 2x100=200 85
80 2x100=200 80 (square-shaped type)

160
124
64 124 5
850

2x100=200

25
124

25
124
110

350
50

157
124

350
95

110

157
105

60

95
C/L C/L

213
256

213
246

175

165
160

(required space) 160


150
10

125

80
42

130

80
Connection position ø10 Connection position ø10
(kn 0 (kn 0

90

90
20 C/L 35 or less 35 or less of branch duct

From the floor side 2500 or more


256 of branch duct
50
40

ock ock

For height installation


1500 or more
157 (Note 4) 157 (Note 4) (round shape type) hole (round shape type) hole
Hanging bolt 90 ) 90 )
350 4 1 2 Connection position 350 Connection position
4-M8~M10 of branch duct of branch duct Connection position 183 Connection position 196
280 of fresh air intake kit of fresh air intake kit
Connection position (round shape type) A (square-shaped type)
330 (direct installation type) C arrow view (direct installation type) C arrow view
of branch duct
(round shape type)

[FCNQ30-48MV14] [FCNQ30-48MV14]
16-M4 Prepared hole Required space 1500mm or more
200mm or more
55 840 55
Adjustable(0~675)

Connection position 55 840 55 1500mm


340 of branch duct 27-M4 Prepared hole 1500mm or more
3 81 2x100=200 85 or more
80 2x100=200 80 (square-shaped type)
64 160 5 200mm
160
850

or more 1500mm or more


167

50
167
95

95

93
105

The necessary space is 500mm or more when the


60

29

air-outlet is blocked with the accessory.


160
298

Moreover when the corner areas are blocked


288

175

(both right and left of the blocked air outlet),


160

29

(required space) 160


150
10

42
125
165

130

1500 or more 67

the necessary space is 200mm or more.


20 C/L 35 or less 35 or less
From the floor side 2500 or more

256
50
40

For height installation

157 (Note 4) 157 (Note 4)


Hanging bolt 350 Connection position Connection position
4-M8~M10 4 1 2 of branch duct 350 of branch duct
280
Connection position (round shape type) A (square-shaped type)
330
of branch duct
(round shape type)

Notes:
1
Sticking location for manufacture's label
manufacture's label for indoor unit: 1 Liquid pipe connection
Suction grille inner side's electric components box's lid surface 2 Gas pipe connection
manufacture's label for decoration panel :
3 Drain pipe connection
Decoration panel's corner decoration cover inner surface
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller 4 Power-source wiring and a unit
in detail. wiring connection
3
When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit 5 Connection wiring/remote control
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required. wiring connection
4
Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less 6 Air-outlet
between the indoor unit and the ceiling opening so that 7 Suction grille
the panel overlap allowance can be ensured.
5 8 Corner decoration cover
Please do not place the thing been damp and troubled under an indoor unit.
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 9 Drain hose (accessory)

20
DIMENSIONS (Unit: mm)

REMOTE CONTROLLER
Wireless type Remote controller dimensions

BRC7F633F BRC4C64 CEILING MOUNTED CASSETTE TYPE <Round Flow>

Transmitting part Remote controller holder • Receiver installation procedure • Receiver detail
installation procedure Receiver
<Installation to wall surface> Refrigerant
piping side
157

Liquid crystal
remote controller Decoration panel
(Wireless) Drain piping
side
Remote controller
holder

CEILING SUSPENDED TYPE


62 17.5
Receiver installation procedure Receiver detail
The Front Receiver

BRC7NU66

Transmitting part Remote controller holder


installation procedure
<Installation to wall surface>

Remote controller
(Wireless)

Receiver detail
115.5

2-5x9 Slot
Remote controller Service space for ceiling
holder installation

(Srevice space)
More than 90
(Ceiling opening)
83.5
120

106
72
54 18.1

Note :
Do not install more than 3
receivers in the vicinity of one
another.
0.5 49 With 4 or more units, there is
70 18 35 always the possibility of
(Ceiling opening)
malfunction
Switch box
(field Supplied parts)

Wired type Remote controller dimensions

BRC1C61 Remote controller installation procedure


A EXposed body, exposed cord B Exposed body, embedded cord C Exposed body, embedded code
17 Conduit
Staple
42
120

84

117
38

0~5

17 Through hole
(fl12~fl16)
120 17 18
( Distance between
Cord remote controller
23 28 outlet 17
CONTROL BOX and control box )
hole
46
Note) 1. Remote controller cord and Specifications of cord
staple are not attached. Type Vinyl cord with sheath or cable (Insulated thickness: 1 mm or more)
they are field supplied
parts. Size 0.75~1.25 mm2
Total length 500 m
* Countries requiring EMC: Shield wire (insulated thickness: 1 mm or more)

BRC1E62 • Installation method


Upper case Lower case Condit
A Exposed cord B Embedded cord C Embedded cord
Staple
Top left Top center
19 (use switch box) 19
outlet outlet
42

Operation
120

lamp
84

(Green)
40

84
84
40

Code outlet hole


120 19 28 5X15 oblong hole Note)2 28
48.5 46
5X7 oblong hole 23 48.5 Through hole 0~5
Left outlet ( 8- 10) Switch box for one switch Switch box for two switch (Between remote
46 19 Lower case portion ex.) KJB111A ex.) KJB211A controller and
(optional accessory) (optional accessory) control box)
Switch box
Lower case portion [field supplied part]
Note)
1. Remote controller cord and staple are not attached. They are field 2.If the hole size is too large or the location
supplied parts. is not proper, the hole may come out from
Specifications of cord the remote controller.

Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
Size 0.75~1.25 mm2
Total length 500 m
BRC1NU61
44.5
Note)
25 The dimension of hole.
6

20
A

B a
10

B
22 25

17 R2
119

13

B
25 20
77

A A
A

Hole type a (mm)


41 38 A 6
111 24 B 10
41.5

26
Installation service space for outdoor unit (Unit: mm)

For RNQ30-48MY14

1 When there is an obstruction on the inlet side 2 When there is an obstruction on the outlet side

1) When the overhead space is open 1) When the overhead space is open

1. For single unit installation 1. For single unit installation

When there is an
obstruction only ore
rm
on the inlet side 0o
50
re
or
mo 2. For multiple units installation 10
0
mo or
10
0
(more than two units) re 10
0
mo or
re
When there are obstructions
on both sides

100 re
or m mo
ore 0 or
ore 1 00
100 rm
or m 0o
ore 10
ss
2) When there is an obstruction r le
0o
50
2. For multiple units installation in the overhead space

1000 or more
(more than two units)
10
0
mo or 1. For single unit installation
re 10
When there are 0
mo or
re
obstructions on An obstruction
both sides 10
00 in the overhead space
or
mo
re
re
mo
re 0 or
20
0o r mo 50
rm 0o
ore 30
2. For multiple units installation
ss
(more than two units) r le
0o
50

1000 or more
10
0
mo or
re

2) When there is an obstruction An obstruction


10
in the overhead space in the overhead space 0o
rm
ore

ess
1. For single unit installation l
1000 or more

0 or
50
re
mo
or
When there is an 10
00

obstruction on the An obstruction


inlet side in the overhead
space e
or
rm
10
0o 3 When there are obstructions on both
the inlet and outlet sides
When there are obstructions ss (When the obstruction on the outlet side is higher than the
1000 or more

r le
0o unit itself)
on the inlet side and 50

both sides
An obstruction 1) When the overhead space is open
in the overhead (There is no limit to the height of the obstruction on the
space
150
or m
outlet side.)
ore e
150 or
rm
or m
ore 1 50
o 1. For single unit installation
H
L

0
2. For multiple units installation (more than two units) 10 ore
L H 0 or
m
50 ore
m
When there are obstructions or

on the inlet side and


both sides 2. For multiple units installation
1000 or more

10 ss 10
0 r le 0
mo or 0o (more than two units) mo or
re 50 re 10
0
mo or
An obstruction re
in the overhead 10
space 0o
L

10
H

00 rm
or ore
mo
re
0
ore 30 ore
20
0o o rm L H or
m
rm 3 00 00
ore 10 ore
m
or

Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
27