Brosur Cassette Non Inverter R410a FCNQ Ac Daikin
Brosur Cassette Non Inverter R410a FCNQ Ac Daikin
CEILING MOUNTED
CASSETTE TYPE
Round Flow
MIDDLE STATIC
PRESSURE
TYPE
Indoor unit
Outdoor unit
OUTDOOR UNIT
1
26 30 36 42 48
26,000 30,000 36,000/35,000* 2
42,600/42,000* 2,3
48,000
7.6 8.8 10.6/10.4*2 12.5/12.3*2,3 14.1
2
CEILING MOUNTED CASSETTE TYPE Round Flow
Sound level
43/32dB(A) High
FCNQ36M
Low
Option (220V)
Accessory required for indoor unit.
BRC1C61
Note: Remote controller cable not
included. Cables must be procured
locally.
BRC1E62
Note: Remote controller cable not
included. Cables must be procured
locally.
BRC7F633F
Features
Comfort Remote controller Cleanliness Work & Servicing Control features Options Others
Ceiling soiling prevention
DIII-NET communication
Swing pattern selection
Control by 2 remote
High-efficiency filter
Setpoint auto reset
heat exchangers
Pre charged for
Interlock control
Two selectable
Long-life filter
On/Off timer
Auto-restart
Auto swing
up to 15 m
up to 10 m
controllers
Filter sign
controller
standard
(2 step)
control
• • • • • *1 *2 *2 *2 *2 *3
• • *4 *5
• • • • • • • • • • • • • *6
*1Applicable when wired remote controller is used *4Applicable to RNQ30-48M outdoor units
*2Applicable when BRC1E62 is used *5Applicable to RNQ13-26M outdoor units
*3Applicable when BRC1C61 is used *6For the outdoor units
3
Avoids uneven temperature and discomfort caused by drafts.
L-shaped Opposite
All-round flow 3-way flow
2-way flow 2-way flow
4
CEILING MOUNTED CASSETTE TYPE Round Flow
Air direction Standard setting Setting to prevent soiling of ceiling* 256 mm *1 266 mm *2
Standard position to Recommended for shops with
Desired light coloured ceilings that
situation prevent draft. must be kept spotless.
*1 298 mm high with 30-48M
*2 308 mm high with 30-48M
Auto-swing Auto-swing between Auto-swing between
15° and 60° 25° and 60°
Easy height adjustment
5-levels Each corner of the unit has an Adjuster Pocket that
air direction Settable to 5 different Settable to 5 different lets you easily adjust the unit's suspended height.
setting levels between 15° and 60° levels between 25° and 60°
Note: If the wireless remote control option is installed, a light receptor
unit is housed in one of the adjuster pockets.
Auto air The air direction is set automatically to the
memorised position of the previous air direction.
direction control All models can be installed without
*Closing of the corner discharge outlets is recommended. using lifter because of the light weight.
5
OUTDOOR UNIT
Pre charged1 10 m 15 m
30 m 50 m
Max. length 30 m (Equivalent length (Equivalent length
50m) 70m)
Max. level
difference 10 m 15 m 20 m 30 m
Note:
1
Additional refrigerant charging is required if the refrigerant pipe is longer than the
length.
Equipped with scroll compressor
for quiet operation 4-direction piping offers greater
(Applies to RNQ42-48M)
layout freedom (Applies to RNQ30-48M)
Smooth running, minimal The outer panel for the piping connection
vibration, low operating part of the front, right side and backside can
sound. be removed and is easier for
post-installation piping work.
Separation
available
Durability
As the bottom frame is subject to corrosion,
Operation sound
(In case of RNQ09-21M:220-240 V, RNQ26-36M:220 V/380 V,
corrosion-proof galvarium steel plate is adopted
240 V/415 V, RNQ42-48M:380 V, 415 V) dB(A) to enhance the durability.
Outdoor unit Sound level
RNQ09MV14 48
Heat exchange fins provided with anti-corrosion
RNQ13MV14 49
treatment (Applies to RNQ09-26, 36-48M)
RNQ18MV14 51
To achieve increased durability by improved resistance to salt corrosion and
RNQ21MV14 52
atmospheric pollution, Anti corrosion treated heat exchangers (with special
RNQ26MV14/RNQ26MY14 54 acryl pretreatment) are used for the heat exchanger of the outdoor unit.
RNQ30MV14/RNQ30MY14 55 Construction
RNQ36MV14/RNQ36MY14 54 Non-treated fin Aluminium
Hydrophilic film
RNQ42MY14 56 Anti corrosion
treated heat Aluminium
Corrosion resistant
RNQ48MY14 58 exchangers acrylic resin
10
Simple system provides a diverse assortment of control modes.
Control Applicable
Wired remote controller Wireless remote controller
pattern model
Control by 1
remote (Basic system)
controller FCNQ Non-polar, double-core Signal receiver unit installed
(max. wiring length 500 m) on indoor unit
For
Group simultaneous
control control of up to
16 indoor units. Automatic address setting function Automatic address setting function
Signal receiver unit installed
on 1 indoor unit
Operation and
surveillance is
carried out using
Control by the contact signal
external from the operation
command control box in the
Optional wiring adaptor for Optional wiring adaptor for
building
surveillance electrical appendices is necessary electrical appendices is necessary
(security) room.
Centralised control, with setting as Centralised control of on/off by Unified control of weekly schedule With its high functionality, the full
simple as it is with a standard group or all at once for up to 256 for up to 1,024 indoor units. colour “all-in-one” graphic controller
remote controller, of up to 64 groups indoor units. Schedule timer sets on/off time in 1 minute units facilitates management of SkyAir
(1,024 indoor units) is possible. to be executed twice a day for a week at a time. System in a variety of ways.
11
LCD REMOTE CONTROLLER Optional accessory
Clear Display
Dot matrix display Backlight
A combination of fine dots display
enables various icons.
Large text display is easy to
see.
Energy saving
NEW Setpoint auto reset NEW Setpoint range set
- Even if the set temperature is changed, it returns to the preset temperature - Saves energy by limiting the
after apreset period of time. min. and max. set temperature.
- Period selectable from 30min/60min/90min/120min. - Avoids excessive heating or
Restaurant sample cooling.
Restaurant opened Full tables at lunchtime After 30 minutes* - This function is convenient when
Temperature is set to 27ºC Then is lowered to 24ºC for Automatically returns to preset the remote controller is installed
crowded room temperature (27ºC)
Returns to at a place where any number of
27 °C 24 °C 27 °C
automatically
people may operate it.
- Sets and saves setting for an increment of time that automatically turns off air
conditioner after a preset period of time for each time operation starts.
- Period can be preset from 30 to 180 minutes in10-minute increments.
Convenience
Weekly schedule Multilingual display
- 5 actions per day can be scheduled for each day Display is available in 11
of the week. languages.
- The holiday function will disable schedule timer (English, German, French, Spanish,
for the days that have been set as holiday. Italian, Portuguese, Greek, Dutch,
Russian, Turkish, and Polish).
NEW - 3 independent schedules can be set.
(e.g. summer, winter, mid-season)
12
control configurations and can control multiple indoor units.
Wired LCD remote controller
Wired remote controller has
Easy to read because of large LCD screen.
built-in temperature-sensor
The rubber switch and the (Applies to wired remote controllers (BRC1C61/1E62))
oil-resistant plastic casing are Enables temperature sensing closer to target
adopted for durability. area for improved comfort. (When using remote
Only 17 mm thick. Can be control from another room, temperature-sensor in
indoor unit's air inlet must be selected.)
installed either recessed or
exposed.
13
Abundance of functions that provide comfortable
air-conditioning in stores and offices.
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Comfort
Auto-swing High-ceiling application
Delivers comfortable The air flow direction can be Delivers air-conditioning comfort all the way down to the floor
air-conditioning to all areas, near fixed at your desited angle in air-conditioning zones with high ceilings.
to and far from the by the remote controller.
air-conditioner.
(1) Standard setting Note:When units are installed on high ceilings, depending on the model,
various restrictions concerning maximum height, air discharge direction,
and choice of options may apply.
(2) Ceiling soiling prevention
setting
Two selectable temperature-sensors
Temperature-sensors are included in the indoor unit and
optional wired remote controller. Temperature sensing closer
Switchable fan speed to target area is possible to further increase the comfort level.
High setting provides maximum reach while low setting Use the temperature-sensor in
minimises drafts. the indoor unit when controlling
air conditioning from another
room.
Remote Controller
Setpoint auto reset Off timer (programmed)
Even if the set temperature is changed, it returns to the preset Sets and saves setting for an increment of time that
temperature after a preset period of time. automatically turns off air conditioner after a preset period of
time for each time operation starts.
Cleanliness
Anti-bacterial air filter
The Air filter has a anti-bacterial treatment to help prevent the growth of bacteria and mould on it.
14
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Long-life filter
Maintenance is not required for one year.
The filter is washable and can be reused.
Control features
Auto-restart External command control
If there is a power outage while the equipment is operating, Operation and surveillance is carried out using the contact
operations will restart in the same mode as before the power signal from the operation control box in the building
cut when electricity is restored. surveillance (security) room.
*An option is required.
Options
High-efficiency filter unit Fresh-air intake kit
Two types are available: 65% and 90% colorimetry. You can provide air-conditioning with fresh air from outside.
Convenient for places where a ventilation fan cannot be
installed.
Ultra long-life filter Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts
should, as required, be procured locally.
Requires no maintenance for about 4 years* (10,000h) in **Outside Air fan interlocked with air conditioning unit is necessary. Optional
stores and offices. PCB(KRP1C63)is required for interlocking.
*For dust concentration of 0.15 mg/m3 ***It is recommended that the volume of outdoor air introduced through the kit
is limited to 10% of the maximum airflow rate of the indoor unit. Introducing
higher quantities will increase the operating noise and may also influence
temperature sending.
Others
Anti corrosion treated heat exchangers
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated
heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
In high corrosive areas, regular maintenance needs to be carried out.
15
SPECIFICATIONS
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
16
DIMENSIONS (Unit: mm)
67
160
160
860~910(Ceiling opening space) (Note 4)
Side
167
93
95
110
124
29
95
157 157
Connection position Connection position
950
350 350 of branch duct
C of branch duct
(square-shaped type) (square-shaped type)
B arrow view B arrow view
6
Drain Connection
Side
7 [FCNQ13-26MV14] [FCNQ30-48MV14]
420
A arrow view 160
160 167
Connection position Connection position
of branch duct 124 of branch duct 93 67
(square-shaped type) 109 (square-shaped type) 95
[FCNQ13-26MV14] [FCNQ13-26MV14] 95
20-M4 20-M4 29
16-M4 Prepared hole Prepared hole Prepared hole
55 840 55 Connection position
Adjustable(0~675)
55 840 55
20-M4 Prepared hole
2x100=200 80
80
340 of branch duct 3 81 2x100=200 85
80 2x100=200 80 (square-shaped type)
160
124
64 124 5
850
2x100=200
25
124
25
124
110
350
50
157
124
350
95
110
157
105
60
95
C/L C/L
213
256
213
246
175
165
160
125
80
42
130
80
Connection position ø10 Connection position ø10
(kn 0 (kn 0
90
90
20 C/L 35 or less 35 or less of branch duct
ock ock
[FCNQ30-48MV14] [FCNQ30-48MV14]
16-M4 Prepared hole Required space 1500mm or more
200mm or more
55 840 55
Adjustable(0~675)
50
167
95
95
93
105
29
175
29
42
125
165
130
1500 or more 67
256
50
40
Notes:
1
Sticking location for manufacture's label
manufacture's label for indoor unit: 1 Liquid pipe connection
Suction grille inner side's electric components box's lid surface 2 Gas pipe connection
manufacture's label for decoration panel :
3 Drain pipe connection
Decoration panel's corner decoration cover inner surface
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller 4 Power-source wiring and a unit
in detail. wiring connection
3
When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit 5 Connection wiring/remote control
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required. wiring connection
4
Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less 6 Air-outlet
between the indoor unit and the ceiling opening so that 7 Suction grille
the panel overlap allowance can be ensured.
5 8 Corner decoration cover
Please do not place the thing been damp and troubled under an indoor unit.
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 9 Drain hose (accessory)
20
DIMENSIONS (Unit: mm)
REMOTE CONTROLLER
Wireless type Remote controller dimensions
Transmitting part Remote controller holder • Receiver installation procedure • Receiver detail
installation procedure Receiver
<Installation to wall surface> Refrigerant
piping side
157
Liquid crystal
remote controller Decoration panel
(Wireless) Drain piping
side
Remote controller
holder
BRC7NU66
Remote controller
(Wireless)
Receiver detail
115.5
2-5x9 Slot
Remote controller Service space for ceiling
holder installation
(Srevice space)
More than 90
(Ceiling opening)
83.5
120
106
72
54 18.1
Note :
Do not install more than 3
receivers in the vicinity of one
another.
0.5 49 With 4 or more units, there is
70 18 35 always the possibility of
(Ceiling opening)
malfunction
Switch box
(field Supplied parts)
84
117
38
0~5
17 Through hole
(fl12~fl16)
120 17 18
( Distance between
Cord remote controller
23 28 outlet 17
CONTROL BOX and control box )
hole
46
Note) 1. Remote controller cord and Specifications of cord
staple are not attached. Type Vinyl cord with sheath or cable (Insulated thickness: 1 mm or more)
they are field supplied
parts. Size 0.75~1.25 mm2
Total length 500 m
* Countries requiring EMC: Shield wire (insulated thickness: 1 mm or more)
Operation
120
lamp
84
(Green)
40
84
84
40
Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
Size 0.75~1.25 mm2
Total length 500 m
BRC1NU61
44.5
Note)
25 The dimension of hole.
6
20
A
B a
10
B
22 25
17 R2
119
13
B
25 20
77
A A
A
26
Installation service space for outdoor unit (Unit: mm)
For RNQ30-48MY14
1 When there is an obstruction on the inlet side 2 When there is an obstruction on the outlet side
1) When the overhead space is open 1) When the overhead space is open
When there is an
obstruction only ore
rm
on the inlet side 0o
50
re
or
mo 2. For multiple units installation 10
0
mo or
10
0
(more than two units) re 10
0
mo or
re
When there are obstructions
on both sides
100 re
or m mo
ore 0 or
ore 1 00
100 rm
or m 0o
ore 10
ss
2) When there is an obstruction r le
0o
50
2. For multiple units installation in the overhead space
1000 or more
(more than two units)
10
0
mo or 1. For single unit installation
re 10
When there are 0
mo or
re
obstructions on An obstruction
both sides 10
00 in the overhead space
or
mo
re
re
mo
re 0 or
20
0o r mo 50
rm 0o
ore 30
2. For multiple units installation
ss
(more than two units) r le
0o
50
1000 or more
10
0
mo or
re
ess
1. For single unit installation l
1000 or more
0 or
50
re
mo
or
When there is an 10
00
r le
0o unit itself)
on the inlet side and 50
both sides
An obstruction 1) When the overhead space is open
in the overhead (There is no limit to the height of the obstruction on the
space
150
or m
outlet side.)
ore e
150 or
rm
or m
ore 1 50
o 1. For single unit installation
H
L
0
2. For multiple units installation (more than two units) 10 ore
L H 0 or
m
50 ore
m
When there are obstructions or
10 ss 10
0 r le 0
mo or 0o (more than two units) mo or
re 50 re 10
0
mo or
An obstruction re
in the overhead 10
space 0o
L
10
H
00 rm
or ore
mo
re
0
ore 30 ore
20
0o o rm L H or
m
rm 3 00 00
ore 10 ore
m
or
Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
27