0% found this document useful (0 votes)
54 views1 page

INVERSOR HIBRIDO PV3000 LVHM 1KW-6KW Solar Inverter 110V MUST

The document describes a low frequency power inverter/charger for solar power systems. It provides specifications for models ranging from 1KW to 6KW, including rated power, surge rating, waveform, output voltage and frequency, efficiency, transfer time, and battery charging parameters.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views1 page

INVERSOR HIBRIDO PV3000 LVHM 1KW-6KW Solar Inverter 110V MUST

The document describes a low frequency power inverter/charger for solar power systems. It provides specifications for models ranging from 1KW to 6KW, including rated power, surge rating, waveform, output voltage and frequency, efficiency, transfer time, and battery charging parameters.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Low Frequency Power Inverter/Charger Solar Power System

PV3000 LVHM Series (1KW-6KW)


Specification

PV30-1KW PV30-1.5KW PV30-2KW PV30-3KW PV30-4KW PV30-5KW PV30-6KW


Features MODEL
LVHM LVHM LVHM LVHM LVHM LVHM LVHM
• Pure sine wave output Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
• Friendly user interface Rated Power 1 KW 1.5 KW 2 KW 3 KW 4 KW 5 KW 6 KW
• 3 Steps charging
Surge Rating(20ms) 3 KW 4.5 KW 6 KW 9 KW 12 KW 15 KW 18 KW
• MFD (multi-function display)
Capable Of Starting Electric Motor 1HP 1HP 1HP 2HP 3HP
• Overload and short-circuit protection
• Set charging voltage/charging current. Waveform Pure sine wave \ same as input (bypass mode)

• Battery low voltage shutdown point can be set to 10/10.5/11V Nominal Output Voltage RMS 100V \110V \ 120V (±10% RMS)
INVERTER
• Power-save mode OUTPUT Output Frequency 50Hz \ 60Hz ±0.3Hz
• Set utility priority/ Battery priority
Inverter Efficiency (Peak) >88%
• Set utility input wide/narrow range
Line Mode Efficiency >95%
• Inverter voltage can be set to 120V:110V/115V/120V
• Inverter frequency can be set to 50/60Hz Power Factor 1.0

• Set utility charging on/off switch Typical Transfer Time 10ms(max)


• 80A MPPT charger Voltage 110V/ 120VAC
AC
Selectable Voltage Range 96~132VAC (For personal computers)
INPUT
Frequency Range 50Hz \ 60Hz(Auto sensing) 40~80Hz
Introduction
Minimum Start Voltage 10.5VDC \ 11VDC for 12VDC mode(*2 for 24VDC, *4 for 48VDC)

PV3000 VHM series is very economical pure sine wave inverter, AC charger inbuilt, from 20A to 60A; Solar/AC priority is configurable, when setting Low Battery Alarm 11VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC)
solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current too lower, in this way system Low Battery Cut Off 10.5VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC)
charge is optimazed best. it enables inverter to operate with all kinds of home appliances. BATTERY
High Voltage Alarm 16.0VDC ±0.3V for 12VDC mode(*2 for 24VDC, *4 for 48VDC)

High Battery Voltage Recover 15.5VDC ±0.3V for 12VDC mode

Idie Consumption-Search Mode <25W when power saver on


Back panel printing description Solar system connection
Output Voltage Depends on battery type

Charge AC Input 1KW \12A 2KW \30A 3KW \40A


120V 1.5KW \16A 4-6KW \NC
1. LCD display Solar Panel CHARGER Breaker Rating
2. AC LED
Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
1 3. INV LED
3 4. Fault Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
2 4 5. Menu Input Voltage Waveform Sine wave (grid or generator)
5 8 6. UP
Nominal Input Frequency 50Hz or 60Hz
6 7 7. Down
9
8. Enter Overload Protection (SMPS Load) Circuit breaker
BYPASS
9. Switch ON/OFF & Output Short Circuit Protection Circuit breaker
PROTECTION
Bypass Breaker Rating 120V 1KW \16A 1.5KW \20A 2KW \30A 3KW \40A 4-6KW \63A
1 5 12 11 3 4 AC Input

Max Bypass Current 30Amp


1. BAT -
2. BAT + Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
3. USB AC Output Maximum PV Charge Current 80A±4A
4. Remote port
DC Voltage 12V \ 24V auto work 24V \ 48V auto work
5. FAN SOLAR
8 6. Charger input protect CHARGER MPPT Range @ Operating Voltage 16~100VDC @ 12V/32~145VDC @ 24V 32~145VDC @ 24V/64~145VDC @ 48V

2
7. Inverter output protect Maximum PV Array Open Circuit
145VDC
8. GND Voltage
9. AC input Standby Power Consumption <2W
Battery
10.AC output Mounting Wall Mount
6 7 11. AGS
Dimensions (W*H*D) 423*247*197mm 597*247*197mm
12.BTS
MECHANICAL
13.AC Output 10A(MAX) SPECIFICATIONS
Net Weight (Solar CHG)(kg) 16.5 17 21.1 20 24.5 24.8 38.2 35.8 45 45
14.PV input Shipping Dimensions (W*H*D) 585*387*322mm 758*387*322mm

Shipping Weight (Solar CHG)(kg) 19.3 20 24.1 22.8 29.1 27.5 42.3 40 49.3 49.3

Operation Temperature Range 0℃ to 40℃

Storage Temperature -15℃ to 60℃

OTHER Audible Noise 60dB MAX

8 14 9 10 8 13 Display LED+LCD

Standard Warranty 1 year