B7 / PLC - 1 (CPU 314) / Program Blocks: Main (OB1)
B7 / PLC - 1 (CPU 314) / Program Blocks: Main (OB1)
Automation Portal
Main
Name Data type Offset Default value Comment
Temp
OB1_EV_CLASS Byte 0.0 Bits 0-3 = 1 (Coming event), Bits 4-7 = 1 (Event class 1)
OB1_SCAN_1 Byte 1.0 1 (Cold restart scan 1 of OB 1), 3 (Scan 2-n of OB 1)
OB1_PRIORITY Byte 2.0 Priority of OB Execution
OB1_OB_NUMBR Byte 3.0 1 (Organization block 1, OB1)
OB1_RESERVED_1 Byte 4.0 Reserved for system
OB1_RESERVED_2 Byte 5.0 Reserved for system
OB1_PREV_CYCLE Int 6.0 Cycle time of previous OB1 scan (milliseconds)
OB1_MIN_CYCLE Int 8.0 Minimum cycle time of OB1 (milliseconds)
OB1_MAX_CYCLE Int 10.0 Maximum cycle time of OB1 (milliseconds)
OB1_DATE_TIME Date_And_Time 12.0 Date and time OB1 started
Constant
Network 1:
%M10.1 %Q0.1
"Start" "B1"
S
%Q0.2
"B2"
S
Network 2:
%M20.1 %Q0.1
"S2" "B1"
R
Network 3:
%M20.2 %Q0.2
"S1" "B2"
R
%Q0.3
"DC"
S
Network 4:
%T1
%Q0.3 "Tag_11" %Q0.3
"DC" S_ODT "DC"
S Q R
S5T#5s TV BI ...
... R BCD ... %M20.3
"Vx"
S
Network 5:
Totally Integrated
Automation Portal
%M5.1
"Tag_30"
S
Network 6:
%T2
%M5.1 "Tag_27" %M10.1
"Tag_30" S_ODT "Start"
S Q
S5T#20s TV BI ...
... R BCD ... %M5.1
"Tag_30"
%C1 R
"Tag_29"
S_CU
CU Q
%M5.5 %MW0
"Tag_33" S CV "Tag_31"
C#10 PV CV_BCD ...
%M5.2
"Tag_32" R
Network 7:
%MW0 %M10.1
"Tag_31" "Start"
==
R
Int
5
%M5.1
"Tag_30"
R
%M5.2
"Tag_32"