SM SZ Ducted Outdoor Ducted Cassette VAHU MFL68082948
SM SZ Ducted Outdoor Ducted Cassette VAHU MFL68082948
Air Conditioner
SERVICE MANUAL
(Exploded View)
MODEL : LUU188HV LUU189HV LUU248HV
LUU249HV LUU368HV LUU369HV
LUU428HV LUU429HV LUU488HV
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
Any reproduction, duplication, distribution (including by way of email, facsimile or other electronic means), publication,
modification, copying or transmission of this Service Manual is STRICTLY PROHIBITED unless you have obtained
the prior written consent of the LG Electronics entity from which you received this Service Manual. The material
covered by this prohibition includes, without limitation, any text, graphics or logos in this Service Manual.
Copyright © 2016 - 2019 LG Electronics Inc. All rights reserved. Only training and service purposes.
1. Specification
Outdoor unit LUU188HV / LUU248HV LUU189HV
Heat Exchanger (Row x Column x Fins per inch) x No. - (2 x 38 x 14) x 1 (2 x 38 x 14) x 1
Maximum Height Outdoor Unit ~ Indoor Unit Max. m (ft) 30 (98) 30 (98)
Operation Range Cooling Min. ~ Max. ℃ DB (℉ DB) -20 (-4) ~ 48 (118) -20 (-4) ~ 48 (118)
(Outdoor Temperature) Heating Min. ~ Max. ℃ DB (℉ DB) -20 (-4) ~ 18 (64) -20 (-4) ~ 18 (64)
Note:
1. Wiring cable size must comply with the applicable local and national code.
2. Due to our policy of innovation some specifications may be changed without notification.
3. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased owing to ambient conditions during operation.
4. Cooling Operation Range : -15(5)~48(118)
When applying the Wind Baffle: -20(-4)~
Heat Exchanger (Row x Column x Fins per inch) x No. - (2 x 38 x 14) x 1 (2 x 32 x 14) x 2
Maximum Height Outdoor Unit ~ Indoor Unit Max. m (ft) 30 (98) 30 (98)
Operation Range Cooling Min. ~ Max. ℃ DB (℉ DB) -20 (-4) ~ 48 (118) -20 (-4) ~ 48 (118)
(Outdoor Temperature) Heating Min. ~ Max. ℃ DB (℉ DB) -18(-0.4) ~ 18 (64) -20 (-4) ~ 18 (64)
Note:
1. Wiring cable size must comply with the applicable local and national code.
2. Due to our policy of innovation some specifications may be changed without notification.
3. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased owing to ambient conditions during operation.
4. Cooling Operation Range : -15(5)~48(118)
When applying the Wind Baffle: -20(-4)~
Type - Scroll
Type - R410A
Type - FVC68D
Refrigerant Oil
Charged volume cc x No. 1 000 x 1
Type - Axial
Fan
Air Flow Rate m /min x No.
3
120 x 2
Type - BLDC
Fan Motor
Output W x No. 124 x 2
Cooling Rated dB(A) 52
Sound Pressure Level
Heating Rated dB(A) 54
Note:
1. Wiring cable size must comply with the applicable local and national code.
2. Due to our policy of innovation some specifications may be changed without notification.
3. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased owing to ambient conditions during operation.
4. Cooling Operation Range : -15(5)~48(118)
When applying the Wind Baffle: -20(-4)~
Note:
O : Applied, X : Not applied
Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with sepa-
rate package
Outdoor Unit
Cond-mid pipe
temperature
thermistor
Ø9.52
Flare Connection
M
Strainer Strainer
Electronic
Expansion Valve
Pressure
Sensor
4 way
Ø15.88 Valve
Flare Connection
Fusible Plug Discharge pipe
temperature
thermistor
Accumulator
Suction pipe
temperature
thermistor Inverter
Compressor
CN_UVW_RD
CN_HEATSINK_WH
CN_REACTOR_
OUT2_WH
MAIN PCB
CN_CENTRAL_WH
CN_DISCHARGE_BK
CN_EEV1_WH CN_C_PIPE_VI CN_H_PRESS
CN_COMP_RD CN_FAN_WH CN_LGMV_WH CN_AIR_YL CN_MID_BR
CN_SUCTION_GR CN_INPUT_BROWN
CN_EEPROM_WH CN_INPUT_BLUE
SW1
CN_FLASH_WH
AC_L_BROWN AC_N_BLUE
CN_HEATER_BL CN_INV
CN_POWER_BL
CEN1_WH_J
CN_CNVSS
CEN2_BL_J
CEN2_MID_BR
CN_COMP(WH)
CN_DISCHA_BK
CN_SUCTION_GR
CN_MAIN(WH)
CN_AIR_YL
CN_H_PRESS_RD
AC_L_BROWN AC_N_BLUE
CN_HEATER_BL CN_INV
CN_POWER_BL
CEN1_WH_J
CN_CNVSS
CEN2_BL_J
CEN2_MID_BR
CN_COMP(WH)
CN_DISCHA_BK
CN_SUCTION_GR
CN_MAIN(WH)
CN_AIR_YL
CN_H_PRESS_RD
CN_FAN1_WH
CN_LGMV_WH
CN-FAN2_BL
CN_MAIN_BL
CN_MAIN_WH
559010 546810
435512
447910
137213A
435300
237202
437212
137213B
435301 349480
435513
237205
135500
552200 552203B
268711C
552560 561410
W6631
W6640 552203A 554160
W4986A
W4986B
EBG13BR EBG13YL EBG13VL EBG13GR EBG13BK
550140A
549610
554031 552113
552115
559010 546810
435512
447910
137213A
435300
237202
437212
137213B
435301 349480
435513
237205
135500
649950 430410
165000
152503 561410 Pressure 548490
261704 Sensor
EBG13GR
55211E 148000
EBG13VI 661400
552202
EBG13BR 552560
W0FZZB 552203A 554160
268711B W6640 W6631
EBG13YL W4986B
268711C
W4986A
550140
Models : LUU368HV / LUU428HV / LUU488HV
546810B
559010
435512
554031
437211
135500
Condenser Total Assembly
447910
349480 55211G
661400
435301
548490
552200
W5210D
W52240B
W52240A
552202 561410
137213
552116
237202 435513
148000 165000
Pressure
W4986B sensor 552560
W6631 W1NF
552203B 552203A
554160
430410
550140 W4986A
152503
249950
263230A
263230C Air 261704
Cond-out
268711C
263230E
Cond-mid
268711D
W6200
268711B W6640 263230B
263230D Suction pipe
Discharge pipe
W0FZZ
135500
552203A
W49810
437212
552203B
237205
661400
552200
548490
W4986B
435300
135500B
552116
W4986A
554160
561410
552202
165000
237204
550140
W6631
Total Assembly
Condenser
552111
261704
552115
152503
430410
249950
263230E
554031
W0FZZ
W6200
268711D
263230C
268711B
263230B
268711C
554031
263230A
W6640
263230D
447910
137213
546810A
546810B
549610
237202
437211
559010
349480
559010
435512
349480
435301
435301
Copyright © 2016 - 2019 LG Electronics Inc. All rights reserved. Only training and service purposes.