0% found this document useful (0 votes)
23 views51 pages

【B】30240102201427 - 画册 英文画册 德业 铜版纸 210-285mm 彩色印刷 4.1版本

Ningbo Deye Inverter Technology Co., Ltd is a Chinese company that provides renewable energy solutions including solar inverters and energy storage systems. It has an annual production capacity of over 600,000 square meters and offers products ranging from 1 kW to 136 kW grid-tied inverters, 3 kW to 50 kW hybrid inverters, and 300 W to 2200 W microinverters. The company prioritizes research and development to provide efficient and reliable energy products.

Uploaded by

Camilo Espinosa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views51 pages

【B】30240102201427 - 画册 英文画册 德业 铜版纸 210-285mm 彩色印刷 4.1版本

Ningbo Deye Inverter Technology Co., Ltd is a Chinese company that provides renewable energy solutions including solar inverters and energy storage systems. It has an annual production capacity of over 600,000 square meters and offers products ranging from 1 kW to 136 kW grid-tied inverters, 3 kW to 50 kW hybrid inverters, and 300 W to 2200 W microinverters. The company prioritizes research and development to provide efficient and reliable energy products.

Uploaded by

Camilo Espinosa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 51

Clean Power For You

Ningbo Deye Inverter Technology Co., Ltd.


Add.: No. 26 South YongJiang Road, Daqi, Beilun, NingBo, Zhejiang, China. World-leading
Tel.: 0086-0574-86228841 | Fax.: 0086-0574-86228852

Energy Storage System Provider


Note: The technical data above mentioned may be updated or
revised due to product development. The data in this brochure
is subject to change without notice. The latest datasheet and
catalogue can be acquired via [email protected]

Ver: 4.1 2023


Stock Code: 605117.SH
    
Choose Deye — Choose a Green and Healthy Life 2023
Company
Profile

1 Ningbo Deye Inverter Technology Co., Ltd, founded in 2007 with registered capital
56 million USD, is one of the China’s high-tech enterprises and a subsidiary of Deye Group. With
a plant area over 600,000㎡ and complete production and testing equipment, Deye has become
a major player in the global solar inverter market.

2 Ningbo Deye Inverter Technology Co., Ltd is dedicated to providing complete


photovoltaic power system solutions, including residential and commercial power plants solutions.
Also, Deye offers solar energy storage system solutions. Among them, PV grid-connected inverter
power range from 1-136kW, Hybrid inverter 3kW-50kW, and microinverter 300W-2200W.

3 As a technology-oriented company, Deye has always been committing to research and


develop new cutting-edge technologies to provide efficiency and reliable products. For example,
Deye adopts T-type three-level topology and enhanced SVPWM algorithm to further improve the
conversion efficiency by 0.7% compared with common SPWM. With frequency droop control
technology, Deye string inverter is able to work with diesel generator, which greatly expands the
scope of the product application.

Re a d m o re

1 2
www.deyeinverter.com www.deyeinverter.com
Milestones Core Technology
Deye hybrid inverter 3-50kW with 208/230/240/400Vac
2022
Launched the latest generation of 50kW hybrid inverter, equipped
4 Automatic switching time 4ms

6
with independent two-way battery terminal port.
6 time periods for battery charging/discharging

2021
Deye Group was successfully listed on SSE of China in 2021, Stock 16 V/f droop control, Max. 16pcs in parallel

24
Code 605117.SH.
Supports using diesel generator to charge battery directly,

30,000 pcs + ensuring system energy supply 7* 24H

By the end of 2019, with total shipments 30,000+, Deye hybrid


inverter has become Top 3 in South Africa, Pakistan and Top 1
96.5 Max. conversion efficiency of 97.6%;
Max. battery charge efficiency of 96.5%

290
Chinese brand in USA.

2017
Max. charging/discharging current of 290A

Deye has launched first generation hybrid inverter and attracted


a lot of attention with many unique features such as V/f droop
control technology and battery DC / DC topology etc...

2007
Founded in 2007 with registered capital of 56 million USD.

Capable | Intelligent | User-friendly | Safety


Reduce your electricity bill and improve your energy independence
Your ideal residential solar energy storage solution

3 4
www.deyeinverter.com www.deyeinverter.com
Core Features Main Highlights
Deye grid-connected inverter 1-136kW Deye microinverter 300-2200W
◆ Support reactive power compensation, comply with UL code.
Max. 8 MPP trackers, Max. efficiency up to 98.9%
◆ Module level monitoring, Max. 4 MPPTs design
High DC/AC ratio 1.5 times for more yields
◆ Max. DC input current 13A, adapt to 600W PV module
Wide output voltage range 277-520Vac
◆ Rapid shutdown function, safe and reliable
Zero export application, response speed within 0.5S ◆ Zigbee or WIFI communication

T-type three-level topology and enhanced SVPWM ◆ IP67 protection degree, 10 years warranty

Production Power
Type II DC / AC SPD, frequency droop control technology
W

3600
Max. DC input current of 16A/string, adpat to 600W solar panel
3000

String intelligent monitoring (optional), Ani-PID function (Optional) 2400

1800

1200

600

0
00:00 03:00 06:00 09:00 12:00 15:00 18:00 21:00

Physical Layout

0W 200 180 150


W W W

170 170 280 250


W W W W

270 280 260 240


W W W W

5 6
www.deyeinverter.com www.deyeinverter.com
World-Class
Components Suppliers
Deye chooses world-class suppliers to ensure the high quality of its products.

MOSFET, IGBT

Complete
IC
Manufacturing
System

Capacitor, Inductor Diode

Relay FAN

7 8
www.deyeinverter.com www.deyeinverter.com
Deye
Inverter
Portfolio
Three Phase
String Inverter (LV) Single Phase
Hybrid Inverter

Single Phase
String Inverter

Microinverter

Three Phase Three Phase


Accessory &
String Inverter Hybrid Inverter
monitoring

9 10
www.deyeinverter.com www.deyeinverter.com
Single Phase String Inverter
Technical Data
SUN-1K-G04 SUN-1.5K-G04 SUN-2K-G04 SUN-2.2K-G04 SUN-2.5K-G04 SUN-2.7K-G04 SUN-3K-G04 SUN-3.3K-G04 SUN-3.6K-G04 SUN-4K-G04
Model P1-EU-AM1 P1-EU-AM1 P1-EU-AM1 P1-EU-AM1 P1-EU-AM1 P1-EU-AM1 P1-EU-AM1 P1-EU-AM1 P1-EU-AM1 P1-EU-AM1

SUN-1/1.5/2/2.2/2.5/2.7/3/3.3/3.6/4K-G04P1-EU-AM1
PV String Input Data
Max. PV Input Power (kW) 1.3 2 2.6 2.9 3.3 3.5 3.9 4.3 4.7 5.2
Max. PV Input Voltage (V) 550
Start-up Voltage (V) 80
MPPT Voltage Range (V) 70-500
Rated PV Input Voltage (V) 360 420
Max. Operating PV Input Current (A) 20
Max. Input Short Circuit Current (A) 30
No. of MPPT Trackers/
1/1
No. of Strings per MPPT Trackers
AC Output Side 3
Rated AC Output Active Power (kW) 1 1.5 2 2.2 2.5 2.7 3 3.3 3.6 4
Max. AC Output Apparent Power (kVA) 1.1 1.65 2.2 2.42 2.75 2.97 3.3 3.63 3.96 4.4
Rated AC Output Current (A) 4.6/4.4 6.8/6.5 9.1/8.7 10/9.6 11.4/10.9 12.3/11.8 13.7/13.1 15/14.4 16.4/15.7 18.2/17.4
Max. AC Output Current (A) 5/4.8 7.5/7.2 10/9.6 11/10.6 12.5/12 13.5/13 15/14.4 16.5/15.8 18/17.3 20/19.2
Rated Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Grid Connection Form L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 97.3% 97.5%
Euro Efficiency 96.3% 97.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
1 MPP tracker, Max. efficiency up to 97.5% General Data
Operating Temperature Range (°C) -25 to +65℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 2000m
Zero export application, VSG application
Noise (dB) ≤35 dB (A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
String intelligent monitoring (optional) Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 280×310×184 (Excluding Connectors and Brackets)
Weight (kg) 4.8
Wide output voltage range Warranty 5 Years
Type of Cooling Natural Cooling
Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE-AR-N 4105
Anti-PID function (Optional) Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

80 Low start-up voltage of 80V

11 12
www.deyeinverter.com www.deyeinverter.com
Single Phase String Inverter
Technical Data

Model SUN-3.6K-G04 SUN-4K-G04 SUN-4.2K-G04 SUN-4.6K-G04 SUN-5K-G04 SUN-5.2K-G04 SUN-6K-G04 SUN-6.2K-G04

SUN-3.6/4/4.2/4.6/5/5.2/6/6.2K-G04
PV String Input Data
Max. PV Input Power (kW) 4.7 5.2 5.46 5.98 6.5 6.76 7.8 8.06
Max. PV Input Voltage (V) 550
Start-up Voltage (V) 80
MPPT Voltage Range (V) 70-500
Rated PV Input Voltage (V) 360
Max. Operating PV Input Current (A) 13+13
Max. Input Short Circuit Current (A) 19.5+19.5
No. of MPPT Trackers/
2/1+1
No. of Strings per MPPT Trackers
AC Output Side
Rated AC Output Active Power (kW) 3.6 4 4.2 4.6 5 5.2 6 6.2
Max. AC Output Apparent Power (kVA) 3.96 4.4 4.62 5.06 5.5 5.27 6.6 6.82
Rated AC Output Current (A) 16.4/15.7 18.2/17.4 19.1/18.3 20.9/20 22.7/21.7 23.7/22.7 27.3/26.1 28.2/27
Max. AC Output Current (A) 18/17.2 20/19.1 21/20.1 23/22 25/23.9 26/24.9 30/28.7 31/29.7
Rated Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Grid Connection Form L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 97.3% 97.5%
Euro Efficiency 96.9% 97.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
2 MPP trackers, Max. efficiency up to 97.5% General Data
Operating Temperature Range (°C) -25 to +65℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 2000m
Zero export application, VSG application
Noise (dB) ≤35 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
String intelligent monitoring (optional) Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 330×323×190 (Excluding Connectors and Brackets)
Weight (kg) 8
Wide output voltage range Warranty 5 Years
Type of Cooling Natural Cooling
Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G99, VDE-AR-N 4105
Anti-PID function (Optional) Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

80 Low start-up voltage of 80V

13 14
www.deyeinverter.com www.deyeinverter.com
Single Phase String Inverter
Technical Data

Model SUN-7K-G SUN-7.5K-G SUN-8K-G SUN-9K-G SUN-10K-G

SUN-7/7.5/8/9/10K-G
PV String Input Data
Max. PV Input Power (kW) 9.1 9.8 10.4 11.7 13
Max. PV Input Voltage (V) 550
Start-up Voltage (V) 80
MPPT Voltage Range (V) 70-500
Rated PV Input Voltage (V) 360
Max. Operating PV Input Current (A) 13+26 26+26
Max. Input Short Circuit Current (A) 19.5+39 39+39
No. of MPPT Trackers/
No. of Strings per MPPT Trackers 2/1+2 2/2+2
AC Output Side
Rated AC Output Active Power (kW) 7 7.5 8 9 10
Max. AC Output Apparent Power (kVA) 7.7 8.25 8.8 9.9 11
Rated AC Output Current (A) 31.8/30.4 34.1/32.6 36.4/34.8 40.9/39.1 45.5/43.5
Max. AC Output Current (A) 35/33.5 37.5/35.9 40/38.3 45/43 50/47.8
Rated Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Grid Connection Form L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 97.7%
Euro Efficiency 97.2%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
2 MPP trackers, Max. efficiency up to 97.7% General Data
Operating Temperature Range (°C) -25 to +65℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 2000m
Zero export application, VSG application
Noise (dB) ≤35 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
String intelligent monitoring (optional) Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 330×410×198.5 (Excluding Connectors and Brackets)
Weight (kg) 15.3
Wide output voltage range Warranty 5 Years
Type of Cooling Natural Cooling
Grid Regulation IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99
Anti-PID function (Optional) Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

80 Low start-up voltage of 80V

15 16
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter
Technical Data
SUN-4K-G06P3 SUN-5K-G06P3 SUN-6K-G06P3 SUN-7K-G06P3 SUN-8K-G06P3 SUN-10K-G06P3 SUN-12K-G06P3 SUN-15K-G06P3
Model -EU-AM2 -EU-AM2 -EU-AM2 -EU-AM2 -EU-AM2 -EU-AM2 -EU-AM2 -EU-AM2

SUN-4/5/6/7/8/10/12/15K-G06P3-EU-AM2
PV String Input Data
Max. PV Input Power (kW) 5.2 6.5 7.8 9.1 10.4 13 15.6 19.5
Max. PV Input Voltage (V) 1100
Start-up Voltage (V) 140
MPPT Voltage Range (V) 120-1000
Rated PV Input Voltage (V) 600
Max. Operating PV Input Current (A) 13+13 13+26
Max. Input Short Circuit Current (A) 19.5+19.5 19.5+39
No. of MPPT Trackers/
2/1+1 2/1+2
No. of Strings per MPPT Trackers
AC Output Side 3
Rated AC Output Active Power (kW) 4 5 6 7 8 10 12 15
Max. AC Output Apparent Power (kVA) 4.4 5.5 6.6 7.7 8.8 11 13.2 16.5
Rated AC Output Current (A) 6.1/5.8 7.6/7.3 9.1/8.7 10.7/10.2 12.2/11.6 15.2/14.5 18.2/17.4 22.8/21.8
Max. AC Output Current (A) 6.7/6.4 8.4/8 10/9.6 11.7/11.2 13.4/12.8 16.7/16 20/19.2 25/24
Rated Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.1% 98.2% 98.3% 98.5%
Euro Efficiency 97.5% 97.6% 97.8% 98%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
2 MPP trackers, Max. efficiency up to 98.5% General Data
Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 4000m
Zero export application, VSG application Noise (dB) <45 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)

String intelligent monitoring (optional) Cabinet Size (WxHxD mm) 283×463×178 (Excluding Connectors and Brackets)
Weight (kg) 11
Warranty 5 Years
Type of Cooling Natural Cooling
Wide output voltage range Grid Regulation
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Anti-PID function (Optional)

17 18
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter
Technical Data
SUN-4K-G06P3 SUN-5K-G06P3 SUN-6K-G06P3 SUN-7K-G06P3 SUN-8K-G06P3 SUN-10K-G06P3 SUN-12K-G06P3 SUN-15K-G06P3
Model -EU-AM2-P1 -EU-AM2-P1 -EU-AM2-P1 -EU-AM2-P1 -EU-AM2-P1 -EU-AM2-P1 -EU-AM2-P1 -EU-AM2-P1

SUN-4/5/6/7/8/10/12/15K-G06P3-EU-AM2-P1
PV String Input Data
Max. PV Input Power (kW) 5.2 6.5 7.8 9.1 10.4 13 15.6 19.5
Max. PV Input Voltage (V) 1100
Start-up Voltage (V) 140
MPPT Voltage Range (V) 120-1000
Rated PV Input Voltage (V) 600
Max. Operating PV Input Current (A) 20+20 20+26
Max. Input Short Circuit Current (A) 30+30 30+39
No. of MPPT Trackers/
2/1+1 2/1+2
No. of Strings per MPPT Trackers
AC Output Side 3
Rated AC Output Active Power (kW) 4 5 6 7 8 10 12 15
Max. AC Output Apparent Power (kVA) 4.4 5.5 6.6 7.7 8.8 11 13.2 16.5
Rated AC Output Current (A) 6.1/5.8 7.6/7.3 9.1/8.7 10.7/10.2 12.2/11.6 15.2/14.5 18.2/17.4 22.8/21.8
Max. AC Output Current (A) 6.7/6.4 8.4/8 10/9.6 11.7/11.2 13.4/12.8 16.7/16 20/19.2 25/24
Rated Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.1% 98.2% 98.3% 98.5%
Euro Efficiency 97.5% 97.6% 97.8% 98%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
2 MPP trackers, Max. efficiency up to 98.5% General Data
Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 4000m
Zero export application, VSG application Noise (dB) <45 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)

String intelligent monitoring (optional) Cabinet Size (WxHxD mm) 283×463×178 (Excluding Connectors and Brackets)
Weight (kg) 11
Warranty 5 Years
Intelligent Air
Type of Cooling Natural Cooling
Cooling
Wide output voltage range
Grid Regulation IEC 61727, IEC 62116, EN 50549
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Anti-PID function (Optional)

19 20
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter
Technical Data

Model SUN-15K-G05

SUN-15K-G05
PV String Input Data
Max. PV Input Power (kW) 19.5
Max. PV Input Voltage (V) 1000
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-850
Rated PV Input Voltage (V) 600
Max. Operating PV Input Current (A) 13+26
Max. Input Short Circuit Current (A) 19.5+39
No. of MPPT Trackers/
2/1+2
No. of Strings per MPPT Trackers
AC Output Side 3
Rated AC Output Active Power (kW) 15
Max. AC Output Apparent Power (kVA) 16.5
Rated AC Output Current (A) 22.7/21.7
Max. AC Output Current (A) 25/23.9
Rated Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.5%
Euro Efficiency 98.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
2 MPP trackers, Max. efficiency up to 98.5% General Data
Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 4000m
Zero export application, VSG application Noise (dB) ≤40 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)

String intelligent monitoring (optional) Cabinet Size (WxHxD mm) 332×472×203 (Excluding Connectors and Brackets)
Weight (kg) 15
Warranty 5 Years
Type of Cooling Intelligent Air Cooling
Wide output voltage range Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Anti-PID function (Optional)

21 22
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter
Technical Data

Model SUN-18K-G05 SUN-20K-G05 SUN-22K-G05 SUN-23K-G05 SUN-25K-G05

SUN-18/20/22/23/25K-G05
PV String Input Data
Max. PV Input Power (kW) 23.4 26 28.6 29.9 32.5
Max. PV Input Voltage (V) 1100
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-1000
Rated PV Input Voltage (V) 600
Max. Operating PV Input Current (A) 26+26
Max. Input Short Circuit Current (A) 39+39
No. of MPPT Trackers/
No. of Strings per MPPT Trackers 2/2+2
AC Output Side
Rated AC Output Active Power (kW) 18 20 22 23 25
Max. AC Output Apparent Power (kVA) 19.8 22 24.2 25.3 27.5
Rated AC Output Current (A) 27.3/26.1 30.3/29 33.4/31.9 34.9/33.4 37.9/36.2
Max. AC Output Current (A) 30/28.7 33.3/31.9 36.7/35.1 38.4/36.7 41.7/39.8
Rated Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.5%
Euro Efficiency 98%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
2 MPP trackers, Max. efficiency up to 98.5% General Data
Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 4000m
Zero export application, VSG application Noise (dB) ≤50 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)

String intelligent monitoring (optional) Cabinet Size (WxHxD mm) 362×527×220 (Excluding Connectors and Brackets)
Weight (kg) 20
Warranty 5 Years
Type of Cooling Intelligent Air Cooling
Wide output voltage range Grid Regulation
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Anti-PID function (Optional)

23 24
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter
Technical Data

Model SUN-30K-G04 SUN-33K-G04 SUN-35K-G04 SUN-36K-G04

SUN-30/33/35/36K-G04
PV String Input Data
Max. PV Input Power (kW) 39 42.9 45.5 46.8
Max. PV Input Voltage (V) 1000
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-850
Rated PV Input Voltage (V) 600
Max. Operating PV Input Current (A) 40+40
Max. Input Short Circuit Current (A) 60+60
No. of MPPT Trackers/
No. of Strings per MPPT Trackers 2/3+3
AC Output Side
Rated AC Output Active Power (kW) 30 33 35 36
Max. AC Output Apparent Power (kVA) 33 36.3 38.5 39.6
Rated AC Output Current (A) 45.5/43.5 50/47.8 53/50.7 54.5/52.2
Max. AC Output Current (A) 50/47.9 55/52.6 58.3/55.8 60/57.4
Rated Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.6%
Euro Efficiency 98.1%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
2 MPP trackers, Max. efficiency up to 98.6% General Data
Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 4000m
Zero export application, VSG application Noise (dB) ≤50 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)

String intelligent monitoring (optional) Cabinet Size (WxHxD mm) 362×577×215 (Excluding Connectors and Brackets)
Weight (kg) 23
Warranty 5 Years
Type of Cooling Intelligent Air Cooling
Wide output voltage range Grid Regulation
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Anti-PID function (Optional)

25 26
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter
Technical Data

Model SUN-40K-G04 SUN-45K-G04 SUN-50K-G04

SUN-40/45/50K-G04
PV String Input Data
Max. PV Input Power (kW) 52 58.5 65
Max. PV Input Voltage (V) 1100
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-1000
Rated PV Input Voltage (V) 600
Max. Operating PV Input Current (A) 40+40+40 40+40+40+40
Max. Input Short Circuit Current (A) 60+60+60 60+60+60+60
No. of MPPT Trackers/
No. of Strings per MPPT Trackers 3/3+3+3 4/3+3+3+3

AC Output Side
Rated AC Output Active Power (kW) 40 45 50
Max. AC Output Apparent Power (kVA) 44 49.5 55
Rated AC Output Current (A) 60.6/58 68.2/65.2 75.8/72.5
Max. AC Output Current (A) 66.7/63.8 75/71.7 83.3/79.7
Rated Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.7%
Euro Efficiency 98.1%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
Max. 4 MPP trackers, General Data
Max. efficiency up to 98.7% Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 4000m
Zero export application, VSG application Noise (dB) <50 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)

String intelligent monitoring (optional) Cabinet Size (WxHxD mm) 434×570×243 (Excluding Connectors and Brackets)
Weight (kg) 37.1
Warranty 5 Years
Type of Cooling Intelligent Air Cooling
Wide output voltage range Grid Regulation
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Anti-PID function (Optional)

27 28
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter
Technical Data

Model SUN-60K-G SUN-70K-G SUN-75K-G SUN-80K-G

SUN-60/70/75/80K-G
PV String Input Data
Max. PV Input Power (kW) 78 91 97.5 104
Max. PV Input Voltage (V) 1000
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-850
Rated PV Input Voltage (V) 600
Max. Operating PV Input Current (A) 40+40+40+40
Max. Input Short Circuit Current (A) 60+60+60+60
No. of MPPT Trackers/
No. of Strings per MPPT Trackers 4/3+3+3+3 4/4+4+4+4
AC Output Side
Rated AC Output Active Power (kW) 60 70 75 80
Max. AC Output Apparent Power (kVA) 66 77 82.5 88
Rated AC Output Current (A) 90.9/87 106.1/101.5 113.6/108.7 121.2/115.9
Max. AC Output Current (A) 100/95.7 116.7/111.6 125/119.6 133.3/127.5
Rated Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.6% 98.7%
Euro Efficiency 98.0% 98.1%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
4 MPP trackers, Max. efficiency up to 98.7% General Data
Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 4000m
Zero export application, VSG application
Noise (dB) ≤50 dB(A) ≤55 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
String intelligent monitoring (optional) Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 700×575×297 (Excluding Connectors and Brackets)
Weight (kg) 60
Wide output voltage range Warranty 5 Years
Type of Cooling Intelligent Air Cooling
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
Grid Regulation
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Anti-PID function (Optional)
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Type II DC/AC SPD

29 30
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter
Technical Data

Model SUN-70K-G03 SUN-75K-G03 SUN-80K-G03 SUN-90K-G03 SUN-100K-G03 SUN-110K-G03

SUN-70/75/80/90/100/110K-G03
PV String Input Data
Max. PV Input Power (kW) 91 97.5 104 135 150 150
Max. PV Input Voltage (V) 1000
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-850
Rated PV Input Voltage (V) 600
Max. Operating PV Input Current (A) 40+40+40+40 40+40+40+40+40+40
Max. Input Short Circuit Current (A) 60+60+60+60 60+60+60+60+60+60
No. of MPPT Trackers/
No. of Strings per MPPT Trackers 4/4+4+4+4 6/4+4+4+4+4+4
AC Output Side
Rated AC Output Active Power (kW) 70 75 80 90 100 110
Max. AC Output Apparent Power (kVA) 77 82.5 88 99 110 121
Rated AC Output Current (A) 106.1/101.5 113.6/108.7 121.2/115.9 136.4/130.4 151.5/144.9 166.7/159.4
Max. AC Output Current (A) 116.7/111.6 125/119.6 133.3/127.5 150/143.5 166.7/159.4 183.3/175.4
Rated Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.7% 98.8%
Euro Efficiency 98.1% 98.2%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
Max. 6 MPP trackers, General Data
Max. efficiency up to 98.8% Operating Temperature Range (°C) -25 to +65℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 4000m
Zero export application, VSG application
Noise (dB) ≤55 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
String intelligent monitoring (optional) Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 826×516×312.7 (Excluding Connectors and Brackets)
Weight (kg) 81
Wide output voltage range Warranty 5 Years
Type of Cooling Intelligent Air Cooling
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
Grid Regulation
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Anti-PID function (Optional)
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Type II DC/AC SPD

31 32
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter
Technical Data
SUN-120K-G01P3 SUN-125K-G01P3 SUN-130K-G01P3 SUN-135K-G01P3 SUN-136K-G01P3
Model
-EU-AM8 -EU-AM8 -EU-AM8 -EU-AM8 -EU-AM8

SUN-120/125/130/135/136K-G01P3-EU-AM8
PV String Input Data
Max. PV Input Power (kW) 180 187.5 195 202.5 204
Max. PV Input Voltage (V) 1100
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-1000
Rated PV Input Voltage (V) 600
Max. Operating PV Input Current (A) 40+40+40+40+40+40+40+40
Max. Input Short Circuit Current (A) 60+60+60+60+60+60+60+60
No. of MPPT Trackers/
No. of Strings per MPPT Trackers 8/4+4+4+4+4+4+4+4
AC Output Side
Rated AC Output Active Power (kW) 120 125 130 135 136
Max. AC Output Apparent Power (kVA) 132 135 135 135 136
IEC 61727,IEC 62116,EN 50549,VDE-AR-N 4110,NRS 097 Rated AC Output Current (A) 181.9/174 189.4/181.2 197/188.5 204.6/195.7 206.1/197.2
Max. AC Output Current (A) 200/191.4 204.6/195.7 204.6/195.7 204.6/195.7 206.1/197.2
Rated Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.8%
Euro Efficiency 98.2%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
8 MPP trackers, General Data
Max. efficiency up to 98.8% Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 4000m
Zero export application, VSG application
Noise (dB) ≤65 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
String intelligent monitoring (optional) Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 1006×516×325.5 (Excluding Connectors and Brackets)
Weight (kg) 103
Wide output voltage range Warranty 5 Years
Type of Cooling Intelligent Air Cooling
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
Grid Regulation
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Anti-PID function (Optional)
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Type II DC/AC SPD

33 34
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter(LV)
Technical Data

Model SUN-6K-G05-LV SUN-8K-G05-LV

SUN-6/8K-G05-LV
PV String Input Data
Max. PV Input Power (kW) 7.8 10.4
Max. PV Input Voltage (V) 800
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-700
Rated PV Input Voltage (V) 350
Max. Operating PV Input Current (A) 13+13 13+26
Max. Input Short Circuit Current (A) 19.5+19.5 19.5+39
No. of MPPT Trackers/
2/1+1 2/1+2
No. of Strings per MPPT Trackers
AC Output Side
Rated AC Output Active Power (kW) 6 8
Max. AC Output Apparent Power (kVA) 6 8
Rated AC Output Current (A) 15.8/15.1 21/20.1
Max. AC Output Current (A) 15.8/15.1 21/20.1
Rated Output Voltage/Range (V) 127V/220V, 133V/230V 0.85UN-1.1UN
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.3%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
General Data

LV 127V/220V, 133V/230V and


50/60Hz, Three phase system
Operating Temperature Range (°C)
Permissible Ambient Humidity
-25 to +65℃, >45℃ Derating
0-100%
Permissible Altitude (m) 4000m
Noise (dB) ≤30 dB(A) ≤40 dB(A)
2 MPP trackers, Max. efficiency up to 98.3%
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Zero export application, VSG application Cabinet Size (WxHxD mm) 332×457×203 (Excluding Connectors and Brackets) 332×472×203 (Excluding Connectors and Brackets)
Weight (kg) 11 15
Warranty 5 Years
String intelligent monitoring (optional) Type of Cooling Natural Cooling Intelligent Air Cooling
Grid Regulation NBR 16149, NBR 16150, EN 50549, RD 140
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Wide output voltage range

Anti-PID function (Optional)

35 36
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter(LV)
Technical Data

Model SUN-6K-G06-LV SUN-8K-G06-LV

SUN-6/8K-G06-LV
PV String Input Data
Max. PV Input Power (kW) 7.8 10.4
Max. PV Input Voltage (V) 800
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-700
Rated PV Input Voltage (V) 500
Max. Operating PV Input Current (A) 13+13 13+26
Max. Input Short Circuit Current (A) 19.5+19.5 19.5+39
No. of MPPT Trackers/
2/1+1 2/1+2
No. of Strings per MPPT Trackers
AC Output Side
Rated AC Output Active Power (kW) 6 8
Max. AC Output Apparent Power (kVA) 6 8
Rated AC Output Current (A) 15.8/15.1 21/20.1
Max. AC Output Current (A) 15.8/15.1 21/20.1
Rated Output Voltage/Range (V) 127V/220V, 133V/230V 0.85UN-1.1UN
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.3%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
General Data

LV 127V/220V, 133V/230V and


50/60Hz, Three phase system
Operating Temperature Range (°C)
Permissible Ambient Humidity
-25 to +60℃, >45℃ Derating
0-100%
Permissible Altitude (m) 4000m
Noise (dB) <45 dB(A)
2 MPP trackers, Max. efficiency up to 98.3%
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Zero export application, VSG application Cabinet Size (WxHxD mm) 283×463×178 (Excluding Connectors and Brackets)
Weight (kg) 11
Warranty 5 Years
String intelligent monitoring (optional) Type of Cooling Natural Cooling
Grid Regulation NBR 16149, NBR 16150, EN 50549, RD 140
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Wide output voltage range

Anti-PID function (Optional)

37 38
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter(LV)
Technical Data

Model SUN-10K-G05-LV SUN-12K-G05-LV SUN-15K-G05-LV

SUN-10/12/15K-G05-LV
PV String Input Data
Max. PV Input Power (kW) 13 15.6 19.5
Max. PV Input Voltage (V) 800
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-700
Rated PV Input Voltage (V) 500
Max. Operating PV Input Current (A) 26+26
Max. Input Short Circuit Current (A) 39+39
No. of MPPT Trackers/
2/2+2
No. of Strings per MPPT Trackers
AC Output Side
Rated AC Output Active Power (kW) 10 12 15
Max. AC Output Apparent Power (kVA) 10 12 15
Rated AC Output Current (A) 26.3/25.1 31.5/30.1 39.4/37.6
Max. AC Output Current (A) 26.3/25.1 31.5/30.1 39.4/37.6
Rated Output Voltage/Range (V) 127V/220V, 133V/230V 0.85UN-1.1UN
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
General Data

LV 127V/220V, 133V/230V and


50/60Hz, Three phase system
Operating Temperature Range (°C)
Permissible Ambient Humidity
-25 to +60℃, >45℃ Derating
0-100%
Permissible Altitude (m) 4000m
Noise (dB) ≤50 dB(A)
2 MPP trackers, Max. efficiency up to 98.5%
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Zero export application, VSG application Cabinet Size (WxHxD mm) 362×527×220 (Excluding Connectors and Brackets)
Weight (kg) 20
Warranty 5 Years
String intelligent monitoring (optional) Type of Cooling Intelligent Air Cooling
Grid Regulation NBR 16149, NBR 16150, EN 50549, RD 140
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Wide output voltage range

Anti-PID function (Optional)

39 40
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter(LV)
Technical Data

Model SUN-18K-G04-LV SUN-20K-G04-LV SUN-21K-G04-LV

SUN-18/20/21K-G04-LV
PV String Input Data
Max. PV Input Power (kW) 23.4 26 27.3
Max. PV Input Voltage (V) 800
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-700
Rated PV Input Voltage (V) 350
Max. Operating PV Input Current (A) 40+40
Max. Input Short Circuit Current (A) 60+60
No. of MPPT Trackers/
2/3+3
No. of Strings per MPPT Trackers
AC Output Side
Rated AC Output Active Power (kW) 18 20 21
Max. AC Output Apparent Power (kVA) 18 20 21
Rated AC Output Current (A) 47.3/45.2 52.5/50.2 55.2/52.7
Max. AC Output Current (A) 47.3/45.2 52.5/50.2 55.2/52.7
Rated Output Voltage/Range (V) 127V/220V, 133V/230V 0.85UN-1.1UN
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.6%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
General Data

LV 127V/220V, 133V/230V and


50/60Hz, Three phase system
Operating Temperature Range (°C)
Permissible Ambient Humidity
-25 to +65℃, >45℃ Derating
0-100%
Permissible Altitude (m) 2000m
Noise (dB) ≤50 dB(A)
2 MPP trackers, Max. efficiency up to 98.6%
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Zero export application, VSG application Cabinet Size (WxHxD mm) 362×577×215 (Excluding Connectors and Brackets)
Weight (kg) 23
Warranty 5 Years
String intelligent monitoring (optional) Type of Cooling Intelligent Air Cooling
Grid Regulation NBR 16149, NBR 16150, EN 50549, RD 140
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Wide output voltage range

Anti-PID function (Optional)

41 42
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter(LV)
Technical Data

Model SUN-23K-G04-LV SUN-25K-G04-LV SUN-30K-G04-LV

SUN-23/25/30K-G04-LV
PV String Input Data
Max. PV Input Power (kW) 29.9 32.5 39
Max. PV Input Voltage (V) 800
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-700
Rated PV Input Voltage (V) 400
Max. Operating PV Input Current (A) 40+40+40 40+40+40+40
Max. Input Short Circuit Current (A) 60+60+60 60+60+60+60
No. of MPPT Trackers/
3/3+3+3 4/3+3+3+3
No. of Strings per MPPT Trackers
AC Output Side
Rated AC Output Active Power (kW) 23 25 30
Max. AC Output Apparent Power (kVA) 23 25 30
Rated AC Output Current (A) 60.4/57.7 65.7/62.7 78.8/75.2
Max. AC Output Current (A) 60.4/57.7 65.7/62.7 78.8/75.2
Rated Output Voltage/Range (V) 127V/220V, 133V/230V 0.85UN-1.1UN
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.7%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
General Data

LV 127V/220V, 133V/230V and


50/60Hz, Three phase system
Operating Temperature Range (°C)
Permissible Ambient Humidity
-25 to +65℃, >45℃ Derating
0-100%
Permissible Altitude (m) 4000m
Noise (dB) ≤50 dB(A)
Max. 4 MPP trackers, Max. efficiency up to 98.7%
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Zero export application, VSG application Cabinet Size (WxHxD mm) 434×570×243 (Excluding Connectors and Brackets)
Weight (kg) 37.1
Warranty 5 Years
String intelligent monitoring (optional) Type of Cooling Intelligent Air Cooling
Grid Regulation NBR 16149, NBR 16150, EN 50549, RD 140
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Wide output voltage range

Anti-PID function (Optional)

43 44
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter(LV)
Technical Data

Model SUN-33K-G-LV SUN-35K-G-LV SUN-40K-G-LV SUN-45K-G-LV SUN-50K-G-LV

SUN-33/35/40/45/50K-G-LV
PV String Input Data
Max. PV Input Power (kW) 42.9 45.5 52 58.5 65
Max. PV Input Voltage (V) 800
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-700
Rated PV Input Voltage (V) 400
Max. Operating PV Input Current (A) 40+40+40+40
Max. Input Short Circuit Current (A) 60+60+60+60
No. of MPPT Trackers/
No. of Strings per MPPT Trackers 4/3+3+3+3 4/4+4+4+4
AC Output Side
Rated AC Output Active Power (kW) 33 35 40 45 50
Max. AC Output Apparent Power (kVA) 33 35 40 45 50
Rated AC Output Current (A) 86.7/82.8 91.9/87.8 105/100.3 118.2/112.8 131.3/125.4
Max. AC Output Current (A) 86.7/82.8 91.9/87.8 105/100.3 118.2/112.8 131.3/125.4
Rated Output Voltage/Range (V) 127V/220V, 133V/230V 0.85UN-1.1UN
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.7%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
General Data

LV 127V/220V, 133V/230V and


50/60Hz, Three phase system
Operating Temperature Range (°C)
Permissible Ambient Humidity
-25 to +65℃, >45℃ Derating
0-100%
Permissible Altitude (m) 2000m
Noise (dB) ≤50 dB(A) ≤55 dB(A)
4 MPP trackers, Max. efficiency up to 98.7%
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Zero export application, VSG application Cabinet Size (WxHxD mm) 700×575×297 (Excluding Connectors and Brackets)
Weight (kg) 60
Warranty 5 Years
String intelligent monitoring (optional) Type of Cooling Intelligent Air Cooling
Grid Regulation NBR 16149, NBR 16150, EN 50549, RD 140
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Wide output voltage range

Anti-PID function (Optional)

45 46
www.deyeinverter.com www.deyeinverter.com
Three Phase String Inverter(LV)
Technical Data

Model SUN-60K-G01P3-EU-AM8-LV SUN-70K-G01P3-EU-AM8-LV SUN-75K-G01P3-EU-AM8-LV

SUN-60/70/75K-G01P3-EU-AM8-LV
PV String Input Data
Max. PV Input Power (kW) 90 105 112.5
Max. PV Input Voltage (V) 800
Start-up Voltage (V) 250
MPPT Voltage Range (V) 200-700
Rated PV Input Voltage (V) 500
Max. Operating PV Input Current (A) 40+40+40+40+40+40+40+40
Max. Input Short Circuit Current (A) 60+60+60+60+60+60+60+60
No. of MPPT Trackers/
8/4+4+4+4+4+4+4+4
No. of Strings per MPPT Trackers
AC Output Side
Rated AC Output Active Power (kW) 60 70 75
Max. AC Output Apparent Power (kVA) 60 70 75
Rated AC Output Current (A) 157.5/150.4 183.8/175.5 196.9/188
Max. AC Output Current (A) 157.5/150.4 183.8/175.5 196.9/188
Rated Output Voltage/Range (V) 127V/220V, 133V/230V 0.85UN-1.1UN
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.7%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
DC Component Monitoring Yes
Ground Fault Current Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Residual Current (RCD) Detection Yes
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232 /WiFi/LAN
General Data

LV 120V/208V, 127V/220V, 133V/230V and


50/60Hz, Three phase system
Operating Temperature Range (°C)
Permissible Ambient Humidity
-25 to +60℃, >45℃ Derating
0-100%
Permissible Altitude (m) 4000m
Noise (dB) ≤55 dB(A)
8 MPP trackers, Max. efficiency up to 98.7%
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Zero export application, VSG application Cabinet Size (WxHxD mm) 1006×516×325.5 (Excluding Connectors and Brackets)
Weight (kg) 103
Warranty 5 Years
String intelligent monitoring (optional) Type of Cooling Intelligent Air Cooling
Grid Regulation NBR 16149, NBR 16150, EN 50549, RD 140
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Wide output voltage range

Anti-PID function (Optional)

47 48
www.deyeinverter.com www.deyeinverter.com
Single Phase Hybrid Inverter
Technical Data
SUN-3K SUN-3K SUN-3.6K SUN-5K SUN-6K
Model
-SG04LP1-24-EU -SG04LP1-EU -SG04LP1-EU -SG04LP1-EU -SG04LP1-EU

SUN-3/3.6/5/6K-SG04LP1-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 20-30 40-60 40-60 40-60 40-60
Max. Charging Current (A) 140 70 90 120 135
Max. Discharging Current (A) 140 70 90 120 135
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 3900 3900 4680 6500 7800
Max. DC Input Voltage (V) 500
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Rated DC Input Voltage (V) 370
Max. Operating PV Input Current (A) 13 13+13
Max. Input Short-Circuit Current (A) 17 17+17
No.of MPPT Trackers/
2/1 2/1+1
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 3000 3600 5000 6000
Max. AC Input/Output Apparent Power (VA) 3300 3960 5500 6600
Rated AC Input/Output Current (A) 13.6/13 16.4/15.7 22.7/21.7 27.3/26.1
Max. AC Input/Output Current (A) 15/14.3 18/17.2 25/23.9 30/28.7
Max. Continuous AC Passthrough (grid to load) (A) 35 40
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface WIFI, RS485, CAN
Colorful touch LCD, IP65 protection degree General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
DC AC Normal Alarm

AC couple to retrofit existing solar system Permissible Altitude 2000m


Noise <30 dB(A)
Ingress Protection(IP) Rating IP 65

16 Max. 16 pcs parallel for on-grid and off-grid Inverter Topology Non-Isolated
operation; Support multiple batteries parallel Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 330×433×238 (Excluding Connectors and Brackets)
Weight (kg) 14 15
140 Max. charging/discharging current of 140A Type of Cooling Natural Cooling Intelligent Air Cooling
5 Years/10 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

6 6 time periods for battery charging/discharging Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator

49 50
www.deyeinverter.com www.deyeinverter.com
Single Phase Hybrid Inverter
Technical Data
SUN-3K-SG04LP1 SUN-3K-SG04LP1 SUN-3.6K-SG04LP1 SUN-5K-SG04LP1 SUN-6K-SG04LP1
Model
-24-EU-SM1 -EU-SM1 -EU-SM2 -EU-SM2 -EU-SM2

SUN-3K-SG04LP1-24-EU-SM1
Battery Input Data
Battery Type Lead-acid or Lithium-ion

SUN-3K-SG04LP1-EU-SM1
Battery Voltage Range (V) 20-30 40-60 40-60 40-60 40-60
Max. Charging Current (A) 140 70 90 120 135
Max. Discharging Current (A) 140 70 90 120 135

SUN-3.6/5/6K-SG04LP1-EU-SM2 Charging Strategy for Li-ion Battery


Number of Battery Input
Self-adaption to BMS
1
PV String Input Data
Max. DC Input Power (W) 3900 3900 4680 6500 7800
Max. DC Input Voltage (V) 500
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Rated DC Input Voltage (V) 370
Max. Operating PV Input Current (A) 18 18+18
Max. Input Short-Circuit Current (A) 27 27+27
No.of MPPT Trackers/
2/1 2/1+1
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 3000 3600 5000 6000
Max. AC Input/Output Apparent Power (VA) 3300 3960 5500 6600
Rated AC Input/Output Current (A) 13.7/13.1 16.4/15.7 22.8/21.8 27.3/26.1
Max. AC Input/Output Current (A) 15/14.4 18/17.3 25/24 30/28.7
Max. Continuous AC Passthrough (grid to load) (A) 35 40
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface WIFI, RS485, CAN
Colorful touch LCD, IP65 protection degree General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
DC AC Normal Alarm

AC couple to retrofit existing solar system Permissible Altitude 2000m


Noise <30 dB(A)
Ingress Protection(IP) Rating IP 65

16 Max. 16 pcs parallel for on-grid and off-grid Inverter Topology Non-Isolated
operation; Support multiple batteries parallel Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 376×470×241.5 (Excluding Connectors and Brackets)
Weight (kg) 17.6 19
140 Max. charging/discharging current of 140A Type of Cooling Natural Cooling
5 Years/10 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

6 6 time periods for battery charging/discharging Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator

51 52
www.deyeinverter.com www.deyeinverter.com
Single Phase Hybrid Inverter
Technical Data
SUN-3.6K SUN-5K SUN-6K
Model
-SG03LP1-EU -SG03LP1-EU -SG03LP1-EU

SUN-3.6/5/6K-SG03LP1-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 90 120 135
Max. Discharging Current (A) 90 120 135
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 4680 6500 7800
Max. DC Input Voltage (V) 500
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Rated DC Input Voltage (V) 370
Max. Operating PV Input Current (A) 13+13
Max. Input Short-Circuit Current (A) 17+17
No.of MPPT Trackers/
2/1+1
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 3600 5000 6000
Max. AC Input/Output Apparent Power (VA) 3960 5500 6600
Rated AC Input/Output Current (A) 16.4/15.7 22.7/21.7 27.3/26.1
Max. AC Input/Output Current (A) 18/17.2 25/23.9 30/28.7
Max. Continuous AC Passthrough (grid to load) (A) 35 40
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface WIFI, RS485, CAN
Colorful touch LCD, IP65 protection degree General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
DC AC Normal Alarm

AC couple to retrofit existing solar system


Noise <30 dB(A)
Ingress Protection(IP) Rating IP 65

16 Max. 16 pcs parallel for on-grid and off-grid Inverter Topology Non-Isolated
operation; Support multiple batteries parallel Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 330×580×232 (Excluding Connectors and Brackets)
Weight (kg) 25
135 Max. charging/discharging current of 135A Type of Cooling Intelligent Air Cooling
5 Years/10 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

6 6 time periods for battery charging/discharging Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator

53 54
www.deyeinverter.com www.deyeinverter.com
Single Phase Hybrid Inverter
Technical Data
SUN-3K-SG03LP1 SUN-3.6K-SG03LP1 SUN-5K-SG03LP1 SUN-6K-SG03LP1
Model
-EU-SM2 -EU-SM2 -EU-SM2 -EU-SM2

SUN-3/3.6/5/6K-SG03LP1-EU-SM2
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 70 90 120 135
Max. Discharging Current (A) 70 90 120 135
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 3900 4680 6500 7800
Max. DC Input Voltage (V) 500
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Rated DC Input Voltage (V) 370
Max. Operating PV Input Current (A) 18+18
Max. Input Short-Circuit Current (A) 27+27
No.of MPPT Trackers/
2/1+1
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 3000 3600 5000 6000
Max. AC Input/Output Apparent Power (VA) 3300 3960 5500 6600
Rated AC Input/Output Current (A) 13.7/13.1 16.4/15.7 22.8/21.8 27.3/26.1
Max. AC Input/Output Current (A) 15/14.4 18/17.3 25/24 30/28.7
Max. Continuous AC Passthrough (grid to load) (A) 35 40
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface WIFI, RS485, CAN
Colorful touch LCD, IP65 protection degree General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
DC AC Normal Alarm

AC couple to retrofit existing solar system


Noise <30 dB(A)
Ingress Protection(IP) Rating IP 65

16 Max. 16 pcs parallel for on-grid and off-grid Inverter Topology Non-Isolated
operation; Support multiple batteries parallel Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 366×589.5×237 (Excluding Connectors and Brackets)
Weight (kg) 24.7
135 Max. charging/discharging current of 135A Type of Cooling Natural Cooling
5 Years/10 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

6 6 time periods for battery charging/discharging Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator

55 56
www.deyeinverter.com www.deyeinverter.com
Single Phase Hybrid Inverter
Technical Data
SUN-3.6K SUN-5K SUN-6K SUN-7K SUN-7.6K SUN-8K
Model
-SG05LP1-EU -SG05LP1-EU -SG05LP1-EU -SG05LP1-EU -SG05LP1-EU -SG05LP1-EU

SUN-3.6/5/6/7/7.6/8K-SG05LP1-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 90 120 135 175 190 190
Max. Discharging Current (A) 90 120 135 175 190 190
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 4680 6500 7800 10000 9880 10400
Max. DC Input Voltage (V) 500
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Rated DC Input Voltage (V) 370
Max. Operating PV Input Current (A) 13+13 26+26
Max. Input Short-Circuit Current (A) 17+17 34+34
No.of MPPT Trackers/
2/1+1 2/2+2
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 3600 5000 6000 7000 7600 8000
Max. AC Input/Output Apparent Power (VA) 3960 5500 6600 7700 8360 8800
Rated AC Input/Output Current (A) 16.4/15.7 22.7/21.7 27.3/26.1 31.9/30.5 34.5/33 36.4/34.8
Max. AC Input/Output Current (A) 18/17.2 25/23.9 30/28.7 35/33.5 38/36.3 40/38.3
Max. Continuous AC Passthrough (grid to load) (A) 35 40 50
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface WIFI, RS485, CAN
Colorful touch LCD, IP65 protection degree General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
DC AC Normal Alarm

AC couple to retrofit existing solar system


Noise <30 dB(A)
Ingress Protection(IP) Rating IP 65

16 Max. 16 pcs parallel for on-grid and off-grid Inverter Topology Non-Isolated
operation; Support multiple batteries parallel Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 330×580×232 (Excluding Connectors and Brackets)
Weight (kg) 24.9
190 Max. charging/discharging current of 190A Type of Cooling Intelligent Air Cooling
5 Years/10 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

6 6 time periods for battery charging/discharging Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator

57 58
www.deyeinverter.com www.deyeinverter.com
Single Phase Hybrid Inverter
Technical Data
SUN-3.6K-SG05 SUN-5K-SG05 SUN-6K-SG05 SUN-7K-SG05 SUN-7.6K-SG05 SUN-8K-SG05
Model
LP1-EU-SM2 LP1-EU-SM2 LP1-EU-SM2 LP1-EU-SM2 LP1-EU-SM2 LP1-EU-SM2

SUN-3.6/5/6/7/7.6/8K-SG05LP1-EU-SM2
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 90 120 135 175 190 190
Max. Discharging Current (A) 90 120 135 175 190 190
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 4680 6500 7800 10000 9880 10400
Max. DC Input Voltage (V) 500
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Rated DC Input Voltage (V) 370
Max. Operating PV Input Current (A) 18+18 26+26
Max. Input Short-Circuit Current (A) 27+27 34+34
No.of MPPT Trackers/
2/1+1 2/2+2
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 3600 5000 6000 7000 7600 8000
Max. AC Input/Output Apparent Power (VA) 3960 5500 6600 7700 8360 8800
Rated AC Input/Output Current (A) 16.4/15.7 22.8/21.8 27.3/26.1 31.9/30.5 34.5/33.1 36.4/34.8
Max. AC Input/Output Current (A) 18/17.3 25/24 30/28.7 35/33.5 38/36.4 40/38.3
Max. Continuous AC Passthrough (grid to load) (A) 35 40 50
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface WIFI, RS485, CAN
Colorful touch LCD, IP65 protection degree General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
DC AC Normal Alarm

AC couple to retrofit existing solar system


Noise <30 dB(A)
Ingress Protection(IP) Rating IP 65

16 Max. 16 pcs parallel for on-grid and off-grid Inverter Topology Non-Isolated
operation; Support multiple batteries parallel Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 366×589.5×237 (Excluding Connectors and Brackets)
Weight (kg) 26.8
190 Max. charging/discharging current of 190A Type of Cooling Intelligent Air Cooling
5 Years/10 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

6 6 time periods for battery charging/discharging Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator

59 60
www.deyeinverter.com www.deyeinverter.com
Single Phase Hybrid Inverter
Technical Data

Model SUN-7.6K-SG01LP1-EU SUN-8K-SG01LP1-EU

SUN-7.6/8K-SG01LP1-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 190 190
Max. Discharging Current (A) 190 190
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 9880 10400
Max. DC Input Voltage (V) 500
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Rated DC Input Voltage (V) 370
Max. Operating PV Input Current (A) 26+26
Max. Input Short-Circuit Current (A) 34+34
No.of MPPT Trackers/
2/2+2
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 7600 8000
Max. AC Input/Output Apparent Power (VA) 8360 8800
Rated AC Input/Output Current (A) 34.5/33 36.4/34.8
Max. AC Input/Output Current (A) 38/36.3 40/38.3
Max. Continuous AC Passthrough (grid to load) (A) 50
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface WIFI, RS485, CAN
Colorful touch LCD, IP65 protection degree General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
DC AC Normal Alarm

AC couple to retrofit existing solar system


Noise <30 dB(A)
Ingress Protection(IP) Rating IP 65

16 Max. 16 pcs parallel for on-grid and off-grid Inverter Topology Non-Isolated
operation; Support multiple batteries parallel Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 420×670×233 (Excluding Connectors and Brackets)
Weight (kg) 32
190 Max. charging/discharging current of 190A Type of Cooling Intelligent Air Cooling
5 Years/10 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

6 6 time periods for battery charging/discharging Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator

61 62
www.deyeinverter.com www.deyeinverter.com
Split Phase Hybrid Inverter
Technical Data
SUN-5K SUN-6K SUN-7.6K SUN-8K
Model
-SG01LP1-US -SG01LP1-US -SG01LP1-US -SG01LP1-US

SUN-5/6/7.6/8K-SG01LP1-US
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 120 135 190 190
Max. Discharging Current (A) 120 135 190 190
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 6500 7800 9880 10400
Max. DC Input Voltage (V) 500
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Rated DC Input Voltage (V) 370
Max. Operating PV Input Current (A) 13+13 26+13 26+26
Max. Input Short-Circuit Current (A) 22+22 44+22 44+44
No.of MPPT Trackers/
2/1+1 2/2+1 2/2+2
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 5000 6000 7600 8000
Max. AC Input/Output Apparent Power (VA) 5500 6600 8360 8800
Rated AC Input/Output Current (A) 20.8 25 31.7 33.3
Max. AC Input/Output Current (A) 22.9 27.5 34.8 36.7
Max. Continuous AC Passthrough (grid to load) (A) 40 50
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.9-1
Rated Input/Output Voltage/Range (V) 120/240; 208 0.88Un<U<1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 60/55-65
Grid Connection Form 2L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface WIFI, RS485, CAN
Colorful touch LCD, IP65 protection degree General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
DC AC Normal Alarm

AC couple to retrofit existing solar system


Noise <30 dB(A)
Ingress Protection(IP) Rating TYPE3R

16 Max. 16 pcs parallel for on-grid and off-grid Inverter Topology Non-Isolated
operation; Support multiple batteries parallel Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 420×670×233 (Excluding Connectors and Brackets)
Weight (kg) 30
190 Max. charging/discharging current of 190A Type of Cooling Intelligent Air Cooling
5 Years/10 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

6 6 time periods for battery charging/discharging Grid Regulation


Safety / EMC Standard
EN 50549, UNE 217002, NRS 097, IEEE 1547.1, SRD V2.0
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2, UL 1741

Support storing energy from diesel generator

63 64
www.deyeinverter.com www.deyeinverter.com
Split Phase Hybrid Inverter
Technical Data
SUN-5K-SG02 SUN-6K-SG02 SUN-7.6K-SG02 SUN-8K-SG02 SUN-10K-SG02 SUN-12K-SG02
Model
LP2-US-AM2 LP2-US-AM2 LP2-US-AM2 LP2-US-AM2 LP2-US-AM3 LP2-US-AM3

SUN-5/6/7.6/8K-SG02LP2-US-AM2
Battery Input Data
Battery Type Lead-acid or Lithium-ion

SUN-10/12K-SG02LP2-US-AM3
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 120 135 190 190 220 250
Max. Discharging Current (A) 120 135 190 190 220 250
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 6500 7800 9880 10400 13000 15600
Max. DC Input Voltage (V) 500
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Rated DC Input Voltage (V) 370
Max. Operating PV Input Current (A) 13+13 26+13 26+26 26+26+26
Max. Input Short-Circuit Current (A) 22+22 44+22 44+44 44+44+44
No.of MPPT Trackers/
2/1+1 2/2+1 2/2+2 3/2+2+2
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 5000 6000 7600 8000 10000 12000
Max. AC Input/Output Apparent Power (VA) 5000 6000 7600 8000 10000 12000
Rated AC Input/Output Current (A) 20.9 25 31.7 33.4 41.7 50
Max. AC Input/Output Current (A) 20.9 25 31.7 33.4 41.7 50
Max. Continuous AC Passthrough (grid to load) (A) 35 40 50 60
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 120/240; 208 0.88Un<U<1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 60/55-65
Grid Connection Form 2L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface WIFI, RS485, CAN
Colorful touch LCD, IP65 protection degree General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
DC AC Normal Alarm

AC couple to retrofit existing solar system


Noise <45 dB(A)
Ingress Protection(IP) Rating TYPE 3R

16 Max. 16 pcs parallel for on-grid and off-grid Inverter Topology Non-Isolated
operation; Support multiple batteries parallel Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 420×670×233 (Excluding Connectors and Brackets)
Weight (kg) 35.6
190 Max. charging/discharging current of 190A Type of Cooling Intelligent Air Cooling
5 Years/10 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

6 6 time periods for battery charging/discharging Grid Regulation


Safety / EMC Standard
IEEE 1547.1, SRD V2.0
FCC, UL 1741

Support storing energy from diesel generator

65 66
www.deyeinverter.com www.deyeinverter.com
Single Phase Hybrid Inverter
Technical Data
UN-7.6K-SG02 SUN-8K-SG02 SUN-10K-SG02 SUN-12K-SG02
Model
LP1-EU-AM2 LP1-EU-AM2 LP1-EU-AM3 LP1-EU-AM3

SUN-7.6/8K-SG02LP1-EU-AM2
Battery Input Data
Battery Type Lead-acid or Lithium-ion

SUN-10/12K-SG02LP1-EU-AM3
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 190 190 220 250
Max. Discharging Current (A) 190 190 220 250
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 9880 10400 13000 15600
Max. DC Input Voltage (V) 500
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Rated DC Input Voltage (V) 370
Max. Operating PV Input Current (A) 26+26 26+26+26
Max. Input Short-Circuit Current (A) 44+44 44+44+44
No.of MPPT Trackers/
No.of String Per MPPT Tracker 2/2+2 3/2+2+2
AC Input/Output Data
Rated AC Input/Output Active Power (W) 76000 8000 10000 12000
Max. AC Input/Output Apparent Power (VA) 8360 8800 11000 13200
Rated AC Input/Output Current (A) 34.6/33.1 36.4/34.8 45.5/43.5 54.6/52.2
Max. AC Input/Output Current (A) 38/36.4 40/38.3 50/47.9 60/57.4
Max. Continuous AC Passthrough (grid to load) (A) 50 60
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface WIFI, RS485, CAN
Colorful touch LCD, IP65 protection degree General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
DC AC Normal Alarm

AC couple to retrofit existing solar system


Noise <45 dB(A)
Ingress Protection(IP) Rating IP 65

16 Max. 16 pcs parallel for on-grid and off-grid Inverter Topology Non-Isolated
operation; Support multiple batteries parallel Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 420×670×233 (Excluding Connectors and Brackets)
Weight (kg) 35.6
250 Max. charging/discharging current of 250A Type of Cooling Intelligent Air Cooling
5 Years/10 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

6 6 time periods for battery charging/discharging Grid Regulation VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1,
G98, G99, C10-11, UNE217002, NBR16149/NBR16150
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator

67 68
www.deyeinverter.com www.deyeinverter.com
Single Phase Hybrid Inverter
Technical Data

Model SUN-12K-SG01LP1-EU SUN-14K-SG01LP1-EU SUN-16K-SG01LP1-EU

SUN-12/14/16K-SG01LP1-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 220 250 290
Max. Discharging Current (A) 220 250 290
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 2
PV String Input Data
Max. DC Input Power (W) 15600 18200 20800
Max. DC Input Voltage (V) 500
Start-up Voltage (V) 125
MPPT Voltage Range (V) 150-425
Rated DC Input Voltage (V) 370
Max. Operating PV Input Current (A) 26+26+26
Max. Input Short-Circuit Current (A) 44+44+44
No.of MPPT Trackers/
3/2+2+2
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 12000 14000 16000
Max. AC Input/Output Apparent Power (VA) 13200 15400 17600
Rated AC Input/Output Current (A) 54.5/52.2 63.6/60.9 72.7/69.6
Max. AC Input/Output Current (A) 60/57.4 70/67 80/76.5
Max. Continuous AC Passthrough (grid to load) (A) 100
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
DC AC Normal

05/28/2019 15:34:40
Alarm

Communication Interface WIFI, RS485, CAN


Colorful touch LCD, IP65 protection degree General Data
0 -3.00 16
0 12.00 16 KW
KW ON

25%

0 3.00 16
0 -6.00
KW
16 KW

Esc
Up

Enter
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Down

Permissible Altitude 2000m


DC AC Normal Alarm

AC couple to retrofit existing solar system


Noise <50 dB(A)
Ingress Protection(IP) Rating IP 65

16 Max. 16 pcs parallel for on-grid and off-grid Inverter Topology Non-Isolated
operation; Support multiple batteries parallel Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 464×763×282 (Excluding Connectors and Brackets)
Weight (kg) 52
290 Max. charging/discharging current of 290A Type of Cooling Intelligent Air Cooling
5 Years/10 Years
Warranty
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

6 6 time periods for battery charging/discharging Grid Regulation


Safety / EMC Standard
IEC 61727, IEC 62116, AS 4777.2, NRS 097
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator

69 70
www.deyeinverter.com www.deyeinverter.com
Three Phase Hybrid Inverter
Technical Data
SUN-5K SUN-6K SUN-8K SUN-10K SUN-12K
Model
-SG04LP3-EU -SG04LP3-EU -SG04LP3-EU -SG04LP3-EU -SG04LP3-EU

SUN-5/6/8/10/12K-SG04LP3-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 120 150 190 210 240
Max. Discharging Current (A) 120 150 190 210 240
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 6500 7800 10400 13000 15600
Max. DC Input Voltage (V) 800
Start-up Voltage (V) 160
MPPT Voltage Range (V) 200-650
Rated DC Input Voltage (V) 550
Max. Operating PV Input Current (A) 13+13 26+13
Max. Input Short-Circuit Current (A) 17+17 34+17
No.of MPPT Trackers/
2/1+1 2/2+1
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 5000 6000 8000 10000 12000
Max. AC Input/Output Apparent Power (VA) 5500 6600 8800 11000 13200
Rated AC Input/Output Current (A) 7.6/7.2 9.1/8.7 12.1/11.6 15.2/14.5 18.2/17.4
Max. AC Input/Output Current (A) 8.4/8 10/9.6 13.4/12.8 16.7/15.9 20/19.1
Max. Three-phase Unbalanced Output Current (A) 11.4/10.9 13.6/13 18.2/17.4 22.7/21.7 27.3/26.1
Max. Continuous AC Passthrough (grid to load) (A) 45
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form 3L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 97.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface

100 100% unbalanced output, each phase; Max.


output up to 50% rated power
Communication Interface
General Data
WIFI, RS485, CAN

Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating


DC AC Normal Alarm

AC couple to retrofit existing solar system Permissible Ambient Humidity 0-100%


Permissible Altitude 2000m
Noise ≤55 dB(A)
10 Max. 10 pcs parallel for on-grid and off-grid
operation; Support multiple batteries parallel
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
240 Max. charging/discharging current of 240A Cabinet Size (WxHxD mm) 422×658×254 (Excluding Connectors and Brackets)
Weight (kg) 38
Type of Cooling Intelligent Air Cooling
48V low voltage battery, transformer
48 isolation design Warranty
5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
6 6 time periods for battery charging/discharging
Safety / EMC Standard
OVE-Richtlinie R25, G99, VDE-AR-N 4105
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator


71 72
www.deyeinverter.com www.deyeinverter.com
Three Phase Hybrid Inverter
Technical Data
SUN-5K-SG05 SUN-6K-SG05 SUN-8K-SG05 SUN-10K-SG05 SUN-12K-SG05
Model
LP3-EU-SM2 LP3-EU-SM2 LP3-EU-SM2 LP3-EU-SM2 LP3-EU-SM2

SUN-5/6/8/10/12K-SG05LP3-EU-SM2
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 120 150 190 210 240
Max. Discharging Current (A) 120 150 190 210 240
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 6500 7800 10400 13000 15600
Max. DC Input Voltage (V) 800
Start-up Voltage (V) 160
MPPT Voltage Range (V) 200-650
Rated DC Input Voltage (V) 550
Max. Operating PV Input Current (A) 20+20
Max. Input Short-Circuit Current (A) 30+30
No.of MPPT Trackers/
2/1+1
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 5000 6000 8000 10000 12000
Max. AC Input/Output Apparent Power (VA) 5500 6600 8800 11000 13200
Rated AC Input/Output Current (A) 7.6/7.3 9.1/8.7 12.2/11.6 15.2/14.5 18.2/17.4
Max. AC Input/Output Current (A) 8.4/8 10/9.6 13.4/12.8 16.7/16 20/19.2
Max. Three-phase Unbalanced Output Current (A) 11.4/10.9 13.6/13 18.2/17.4 22.7/21.7 27.3/26.1
Max. Continuous AC Passthrough (grid to load) (A) 45
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form 3L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 97.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface

100 100% unbalanced output, each phase; Max.


output up to 50% rated power
Communication Interface
General Data
WIFI, RS485, CAN

Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating


DC AC Normal Alarm

AC couple to retrofit existing solar system Permissible Ambient Humidity 0-100%


Permissible Altitude 3000m
Noise ≤55 dB(A)
10 Max. 10 pcs parallel for on-grid and off-grid
operation; Support multiple batteries parallel
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
240 Max. charging/discharging current of 240A Cabinet Size (WxHxD mm) 386×660×253 (Excluding Connectors and Brackets)
Weight (kg) 35.2
Type of Cooling Intelligent Air Cooling
48V low voltage battery, transformer
48 isolation design Warranty
5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
6 6 time periods for battery charging/discharging
Safety / EMC Standard
OVE-Richtlinie R25, G99, VDE-AR-N 4105
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator


73 74
www.deyeinverter.com www.deyeinverter.com
Three Phase Hybrid Inverter
Technical Data
SUN-5K-SG01 SUN-6K-SG01 SUN-8K-SG01 SUN-10K-SG01 SUN-12K-SG01 SUN-15K-SG01 SUN-20K-SG01 SUN-25K-SG01
Model HP3-EU-AM2 HP3-EU-AM2 HP3-EU-AM2 HP3-EU-AM2 HP3-EU-AM2 HP3-EU-AM2 HP3-EU-AM2 HP3-EU-AM2

SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2
Battery Input Data
Battery Type Lithium-ion
Battery Voltage Range (V) 160-700
Max. Charging Current (A) 30 30 37 50
Max. Discharging Current (A) 30 30 37 50
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 6500 7800 10400 13000 15600 19500 26000 32500
Max. DC Input Voltage (V) 1000
Start-up Voltage (V) 180
MPPT Voltage Range (V) 150-850
Rated DC Input Voltage (V) 600 700
Max. Operating PV Input Current (A) 20+20 26+20 26+26
Max. Input Short-Circuit Current (A) 30+30 39+30 39+39
No.of MPPT Trackers/
2/1+1 2/2+1 2/2+2
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 5000 6000 8000 10000 12000 15000 20000 25000
Max. AC Input/Output Apparent Power (VA) 5500 6600 8800 11000 13200 16500 22000 27500
Rated AC Input/Output Current (A) 7.6/7.3 9.1/8.7 12.2/11.6 15.2/14.5 18.2/17.4 22.8/21.8 30.4/29 37.9/36.3
Max. AC Input/Output Current (A) 8.4/8 10/9.6 13.4/12.8 16.7/16 20/19.2 25/24 33.4/31.9 41.7/39.9
Max. Three-phase Unbalanced Output Current (A) 13 13 18 22 25 30 35 41.7
Max. Continuous AC Passthrough (grid to load) (A) 40 80
Peak Power (off-grid) (W) 1.5 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form 3L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 97.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface

100 100% unbalanced output, each phase Communication Interface


General Data
WIFI, RS485, CAN

Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating


DC AC Normal Alarm

AC couple to retrofit existing solar system Permissible Ambient Humidity 0-100%


Permissible Altitude 2000m
Noise ≤55 dB(A)
Max. 10 pcs parallel for on-grid and off-grid
10 operation; Support multiple batteries parallel
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
50 Max. charging/discharging current of 50A Cabinet Size (WxHxD mm) 408×638×237 (Excluding Connectors and Brackets)
Weight (kg) 30.5
Type of Cooling Natural Cooling Intelligent Air Cooling
H High voltage battery, higher efficiency Warranty
5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
6 6 time periods for battery charging/discharging
Safety / EMC Standard
OVE-Richtlinie R25, G99, VDE-AR-N 4105
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator


75 76
www.deyeinverter.com www.deyeinverter.com
Split Phase Hybrid Inverter
Technical Data

Model SUN-12K-SG01HP2-US-AM2 SUN-15K-SG01HP2-US-AM2

SUN-12/15K-SG01HP2-US-AM2
Battery Input Data
Battery Type Lithium-ion
Battery Voltage Range (V) 160-500
Max. Charging Current (A) 50
Max. Discharging Current (A) 50
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 15600 19500
Max. DC Input Voltage (V) 550
Start-up Voltage (V) 180
MPPT Voltage Range (V) 150-500
Rated DC Input Voltage (V) 380
Max. Operating PV Input Current (A) 26+26
Max. Input Short-Circuit Current (A) 39+39
No.of MPPT Trackers/
2/2+2
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 12000 15000
Max. AC Input/Output Apparent Power (VA) 12000 15000
Rated AC Input/Output Current (A) 50 62.5
Max. AC Input/Output Current (A) 50 62.5
Max. Three-phase Unbalanced Output Current (A) 50 62.5
Max. Continuous AC Passthrough (grid to load) (A) 150
Peak Power (off-grid) (W) 1.5 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 120/240, 208 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 60/55-65
Grid Connection Form 2L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 97.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface

100 100% unbalanced output, each phase Communication Interface


General Data
WIFI, RS485, CAN

Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating


DC AC Normal Alarm

AC couple to retrofit existing solar system Permissible Ambient Humidity 0-100%


Permissible Altitude 2000m
Noise ≤55 dB(A)
10 Max. 10pcs parallel for on-grid and off-grid
operation; Support multiple batteries parallel
Ingress Protection(IP) Rating TYPE3R
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
50 Max. charging/discharging current of 50A Cabinet Size (WxHxD mm) 408×678×247 (Excluding Connectors and Brackets)
Weight (kg) 30
Type of Cooling Intelligent Air Cooling
H High voltage battery, higher efficiency Warranty
5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Grid Regulation IEEE 1547.1, SRD V2.0
6 6 time periods for battery charging/discharging Safety / EMC Standard FCC, UL 1741

Support storing energy from diesel generator


77 78
www.deyeinverter.com www.deyeinverter.com
Three Phase Hybrid Inverter
Technical Data
SUN-10K-SG01HP3 SUN-12K-SG01HP3 SUN-15K-SG01HP3
Model
-US-AM2 -US-AM2 -US-AM2

SUN-10/12/15K-SG01HP3-US-AM2
Battery Input Data
Battery Type Lithium-ion
Battery Voltage Range (V) 160-500
Max. Charging Current (A) 50
Max. Discharging Current (A) 50
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 13000 15600 19500
Max. DC Input Voltage (V) 550
Start-up Voltage (V) 180
MPPT Voltage Range (V) 150-500
Rated DC Input Voltage (V) 380
Max. Operating PV Input Current (A) 26+26
Max. Input Short-Circuit Current (A) 39+39
No.of MPPT Trackers/
2/2+2
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 10000 12000 15000
Max. AC Input/Output Apparent Power (VA) 10000 12000 15000
Rated AC Input/Output Current (A) 27.8 33.4 41.7
Max. AC Input/Output Current (A) 27.8 33.4 41.7
Max. Three-phase Unbalanced Output Current (A) 30 35 41.7
Max. Continuous AC Passthrough (grid to load) (A) 80
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 120/208 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 60/55-65
Grid Connection Form 3L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 97.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface

100 100% unbalanced output, each phase Communication Interface


General Data
WIFI, RS485, CAN

Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating


DC AC Normal Alarm

AC couple to retrofit existing solar system Permissible Ambient Humidity 0-100%


Permissible Altitude 2000m
Noise ≤55 dB(A)
10 Max. 10pcs parallel for on-grid and off-grid
operation; Support multiple batteries parallel
Ingress Protection(IP) Rating TYPE3R
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
50 Max. charging/discharging current of 50A Cabinet Size (WxHxD mm) 408×678×247 (Excluding Connectors and Brackets)
Weight (kg) 30
Type of Cooling Intelligent Air Cooling
H High voltage battery, higher efficiency Warranty
5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Grid Regulation IEEE 1547.1, SRD V2.0
6 6 time periods for battery charging/discharging Safety / EMC Standard FCC, UL 1741

Support storing energy from diesel generator


79 80
www.deyeinverter.com www.deyeinverter.com
Three Phase Hybrid Inverter
Technical Data
SUN-29.9K-SG01HP3 SUN-30K-SG01HP3 SUN-35K-SG01HP3 SUN-40K-SG01HP3 SUN-50K-SG01HP3
Model
-EU-BM3 -EU-BM3 -EU-BM3 -EU-BM4 -EU-BM4

SUN-29.9/30/35K-SG01HP3-EU-BM3
Battery Input Data
Battery Type Lithium-ion

SUN-40/50K-SG01HP3-EU-BM4
Battery Voltage Range (V) 160-800
Max. Charging Current (A) 50+50
Max. Discharging Current (A) 50+50
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 2
PV String Input Data
Max. DC Input Power (W) 38870 39000 45500 52000 65000
Max. DC Input Voltage (V) 1000
Start-up Voltage (V) 180
MPPT Voltage Range (V) 150-850
Rated DC Input Voltage (V) 600
Max. Operating PV Input Current (A) 36+36+36 36+36+36+36
Max. Input Short-Circuit Current (A) 55+55+55 55+55+55+55
No.of MPPT Trackers/
3/2+2+2 4/2+2+2+2
No.of String Per MPPT Tracker
AC Input/Output Data
Rated AC Input/Output Active Power (W) 29900 30000 35000 40000 50000
Max. AC Input/Output Apparent Power (VA) 29900 33000 38500 44000 55000
Rated AC Input/Output Current (A) 45.4/43.4 45.5/43.5 53.1/50.8 60.7/58 75.8/72.5
Max. AC Input/Output Current (A) 45.4/43.4 50/47.9 58.4/55.8 66.7/63.8 83.4/79.8
Max. Three-phase Unbalanced Output Current (A) 60 60 60 70 83.3
Max. Continuous AC Passthrough (grid to load) (A) 200
Peak Power (off-grid) (W) 1.5 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form 3L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 97.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection
Integrated DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch
Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface

100 100% unbalanced output, each phase Communication Interface


General Data
WIFI, RS485, CAN

05/28/2019 15:34:40

0 12.00
KW

25%
50
ON
0 -3.00
KW

3.00
50

50
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
0
0 -6.00
KW
50 KW

DC AC Normal Alarm

AC couple to retrofit existing solar system Permissible Ambient Humidity 0-100%


Permissible Altitude 2000m
Noise ≤65 dB(A)
10 Max. 10 pcs parallel for on-grid and off-grid
operation; Support multiple batteries parallel
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
100 Max. charging/discharging current of 100A Cabinet Size (WxHxD mm) 527×894×294 (Excluding Connectors and Brackets)
Weight (kg) 80
Type of Cooling Intelligent Air Cooling
H High voltage battery, higher efficiency Warranty
5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
6 6 time periods for battery charging/discharging
Safety / EMC Standard
OVE-Richtlinie R25, G99, VDE-AR-N 4105
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Support storing energy from diesel generator


81 82
www.deyeinverter.com www.deyeinverter.com
Microinverter
Technical Data

Model SUN-M30G4-EU-Q0 SUN-M40G4-EU-Q0 SUN-M50G4-EU-Q0

SUN-M30/40/50G4-EU-Q0
PV String Input Data
Max. PV Input Power (W) 210-420(1 Piece) 210-560(1 Piece) 210-700(1 Piece)
Max. PV Input Voltage (V) 60
Start-up Voltage (V) 20
MPPT Voltage Range (V) 25-55
Rated PV Input Voltage (V) 42.5
Max. Operating PV Input Current (A) 13
Max. Input Short Circuit Current (A) 19.5
No. of MPPT Trackers/
No. of Strings per MPPT Trackers 1/1

AC Output Side
Rated AC Output Active Power (W) 300 400 500
Max. AC Output Apparent Power (VA) 300 400 500
Rated AC Output Current (A) 1.4/1.4 1.9/1.8 2.3/2.2
Max. AC Output Current (A) 1.4/1.4 1.9/1.8 2.3/2.2
Rated Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Grid Connection Form L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Max. Unit per Branch 17 13 10
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 96.5%
Euro Efficiency 96.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Interface
Communication Interface WiFi
General Data
Operating Temperature Range (°C) -40 to +65℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
1 MPP tracker, module level monitoring Permissible Altitude (m) 2000m
Noise (dB) ≤25 dB(A)
IP67 protection degree
Ingress Protection(IP) Rating IP 67
WIFI communication Inverter Topology Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Rapid shutdown function Cabinet Size (WxHxD mm) 248.9×147×38.8 (Excluding Connectors and Brackets)
Easy installation, suitable for quick-plug balcony PV system Weight (kg) 1.85
Warranty 15 Years
<100ms AC fast discharge, compliant with new Type of Cooling Natural Cooling
required standard DIN VDE 0126-95 (<200ms) to IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
Grid Regulation
protect human safety OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Complete NS protection with self-check function
External relay advantage with low temperature, long life,
easier maintenance
25 years design lifetime and 15 years warranty
With integrate WIFI

83 84
www.deyeinverter.com www.deyeinverter.com
Microinverter
Technical Data

Model SUN-M60G4-EU-Q0 SUN-M80G4-EU-Q0 SUN-M100G4-EU-Q0

SUN-M60/80/100G4-EU-Q0
PV String Input Data
Max. PV Input Power (W) 210-420(2 Pieces) 210-560(2 Pieces) 210-700(2 Pieces)
Max. PV Input Voltage (V) 60
Start-up Voltage (V) 20
MPPT Voltage Range (V) 25-55
Rated PV Input Voltage (V) 42.5
Max. Operating PV Input Current (A) 13+13
Max. Input Short Circuit Current (A) 19.5+19.5
No. of MPPT Trackers/
No. of Strings per MPPT Trackers 2/1

AC Output Side
Rated AC Output Active Power (W) 600 800 1000
Max. AC Output Apparent Power (VA) 600 800 1000
Rated AC Output Current (A) 2.8/2.7 3.7/3.5 4.6/4.4
Max. AC Output Current (A) 2.8/2.7 3.7/3.5 4.6/4.4
Rated Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Grid Connection Form L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Max. Unit per Branch 8 6 5
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 96.5%
Euro Efficiency 96.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Interface
Communication Interface WiFi
General Data
Operating Temperature Range (°C) -40 to +65℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
2 MPP trackers, module level monitoring Permissible Altitude (m) 2000m
Noise (dB) ≤25 dB(A)
IP67 protection degree IP 67
Ingress Protection(IP) Rating
WIFI communication Inverter Topology Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Rapid shutdown function Cabinet Size (WxHxD mm) 280.5×190×40 (Excluding Connectors and Brackets)
Easy installation, suitable for quick-plug balcony PV system Weight (kg) 3
Warranty 15 Years
<100ms AC fast discharge, compliant with new Type of Cooling Natural Cooling
required standard DIN VDE 0126-95 (<200ms) to IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
Grid Regulation
protect human safety OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Complete NS protection with self-check function
External relay advantage with low temperature, long life,
easier maintenance
25 years design lifetime and 15 years warranty
With integrate WIFI

85 86
www.deyeinverter.com www.deyeinverter.com
Microinverter
Technical Data
SUN-M130G4 SUN-M160G4 SUN-M180G4 SUN-M200G4 SUN-M220G4
Model
-EU-Q0 -EU-Q0 -EU-Q0 -EU-Q0 -EU-Q0

SUN-M130/160/180/200/220G4-EU-Q0
PV String Input Data
210-460 210-560 210-630 210-700 210-770
Max. PV Input Power (W)
(4 Pieces) (4 Pieces) (4 Pieces) (4 Pieces) (4 Pieces)
Max. PV Input Voltage (V) 60
Start-up Voltage (V) 20
MPPT Voltage Range (V) 25-55
Rated PV Input Voltage (V) 42.5
Max. Operating PV Input Current (A) 18+18+18+18
Max. Input Short Circuit Current (A) 27+27+27+27
No. of MPPT Trackers/
No. of Strings per MPPT Trackers 4/1

AC Output Side
Rated AC Output Active Power (W) 1300 1600 1800 2000 2200
Max. AC Output Apparent Power (VA) 1300 1600 1800 2000 2200
Rated AC Output Current (A) 6/5.7 7.3/7 8.2/7.9 9.1/8.7 10/9.6
Max. AC Output Current (A) 6/5.7 7.3/7 8.2/7.9 9.1/8.7 10/9.6
Rated Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Grid Connection Form L/N/PE
Rated Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Max. Unit per Branch 5 4 3 3 3
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 96.5%
Euro Efficiency 96.0%
MPPT Efficiency >99%
Equipment Protection
DC Polarity Reverse Connection Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
DC Terminal Insulation Impedance Monitoring Yes
Power Network Monitoring Yes
Island Protection Monitoring Yes
Earth Fault Detection Yes
Overvoltage Load Drop Protection Yes
Interface
Communication Interface WiFi
General Data
Operating Temperature Range (°C) -40 to +65℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude (m) 2000m
Noise (dB) ≤25 dB(A)
Ingress Protection(IP) Rating IP 67
Inverter Topology Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 311×250.5×36.5 (Excluding Connectors and Brackets)
Weight (kg) 5.1
Max. DC input current of 18A,
18 adapt to 700W PV module
IP67 protection degree, *10 years warranty Warranty 10 Years
Type of Cooling Natural Cooling
IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
Grid Regulation
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
4 MPP trackers, module level monitoring WIFI communication
*Note: 15 Years Warranty (Only Installed in Germany and Austria)

Rapid shutdown function

87 88
www.deyeinverter.com www.deyeinverter.com
Energy Meter Technical Data
Model CHNT DDSU666 CHNT DTSU666
EASTRON SDM
230 Modbus
EASTRON SDM
630-Modbus V2
EASTRON SDM
630 MCT

Battery Data

Max. direct current measurement (A) 60 80 100 100 1-9999A (with CT)

Direct Voltage measurement 50-950V


/ 176-458V / 147-480V
between phases 50-550V

Direct measurement between 176-264V 100-265V 176-276V 85-480V 20-550V


phase and neutral

Accuracy Class

Active power Class1

Reactive power Class2

Power Supply

Power consumption ≤1W / 8VA ≤1.5W / 6VA ≤2W / 10VA ≤2W / 10VA ≤2W / 10VA

AC power supply input voltage 176-264V 100-265V 176-276V 85-480V 85-275V / 120-380V

AC power supply input frequency 50/60Hz 50Hz 50/60Hz ±2% 50/60Hz ±2%

Generation Specifications

Dimenstions (L/H/W) in mm 36×85×66 100×72×66 36×99×63 72×100×66 72×94.5×65

Weight (kg) 0.21 0.44 0.21 0.42 0.29

Mounting options DIN Rail

Degree of protection IP51

Display LCD

Communication interface RS485

Max. number of devices to connect 32

Regulated working temperature range -25-55℃ -10-45℃ -25-55℃

Limited working temperature range -40-70℃ 25-75℃ /

Humidity ≤75% 0~95%, non-Condensing

Warranty 1.5 years

Typical Application Diagram

PV array Inverter Energy meter Grid

RS485

Home load

89 90
www.deyeinverter.com www.deyeinverter.com
Stick Logger Technical Data
Product Model LSG-3 LSG-4 LSW-3 LS4G-3 LSE-3

GPRS / WIFI / 4G / Ethernet Remote Communication Interface GPRS GPRS WiFi 4G LAN
Monitor your system anywhere in the world.
GSM850 / EGSM900 GSM850 / EGSM900
2.142GHz- 704MHZ-960MHZ Adaptive Network;
Working Frequency / DCS1800 / PCS / DCS1800 / PCS
2.484GHz 1710MHZ-2690MHZ 10M / 100M
1900MHz 1900MHz

Satellite Positioning / GPS / Beidou <15m / / /

External GPRS External GPRS External WiFi External 4G


Antenna /
Stick Antenna Stick Antenna Stick Antenna Stick Antenna

Data Interface RS485 / RS232 / TTL

Working Voltage DC4.7V~DC15V

Working Power 3W 3W 1.5W 5W 1W

SIM Card Chip Card / MicroSIM Chip Card / MicroSIM / MicroSIM /

Memory 2M Flash (2M-16M Optional)

Working Temperature -40℃-85℃

Working Humidity <90% (No Condensing)

No.of Connections One

Serial Communication Rate bps (1200-115200bps Configurable)

Data Acquisition Interval Default 5min (1-15min Configurable)

AT+InstructionSet

User Configuration Remote Server

Bluetooth APP / Web Local Serial Port Web

Firmware Upgrade Remote Upgrade

Others Real-time Control, Data resuming

Stick logger supports GPRS, WIFI, 4G, Ethernet and other communication modes. Its bluetooth function enables local
debugging configuration to collect operation and power generation data from inverters.
It pairs with solarman professional platform to enable remote PV system monitoring and to realize distributed power station
management with lower cost and higher efficiency.

◆ External light indicator, logging status at a glance;

◆ Plug & play, pick power within inverter, no external power needed, easy to install;

◆ Independent from inverter to protect parts inside inverter, eliminate potential


problems;

◆ IP65 water-proof design, resistant to bad weather, enhance stability;

◆ External design, easier to replace faulty equipment;

◆ End-user can monitor yields at any time with SOLARMAN APP.

91 92
www.deyeinverter.com www.deyeinverter.com
Smart PV Management Platform

for distributor account for end user account

Efficiency Safe
· Open station supports one-click · Safe operation, traceable logs, etc;
installation and registration; · Support full lifecycle data storage to
· Problem support one-click ensure data security and reliability.
dispatch and navigation.

Internet

APP PC

Smart PV Monitoring Platform


SOLARMAN Plant deye
Energy-saving and emission-
Monltored Analyzed Networked Solar MAN ID...
reduction
宁波德业—长运房英臻储能电站 Add New Device Plant Settings
2019/03/26 Day Month Year Total
Tree CO 2
Details Plant Info Device Alerts Updated by:2019-03-27 16:49

Internet Internet Internet


Daily Production:26.2kWh Daily Consumption:--
Accumulative tree Accumulative CO 2

Select Paramet... planting emissions


Production P… Daily Product… Monthly Pro… Yearly Produ… Total Prod… Current Power reduction
Generation 0.09 tree(s) 0.03t
11.30kWh 509.10kWh 844.40kWh 31.20kWh
8.00w Decice
Name All Nor... Offl... Aler...
Consumption… Daily Consu… Monthly Con… Yearly Consu… Total Consu…
Interver 1 1 0 0
-- -- -- --
0.00w 宁波德业—长运房英臻储能电站 Logger 1 1 0 0

德业集团(北门)

Electricity Grid Power Daily Grid Fe… Monthly Grid… Yearly Grid F… Total Grid Fe… Plant Type Residential Rooftop
Purchas- 7.70kWh 414.00kWh 675.10kWh 1.13MWh Grid-connected T... Storage System
ing 45.00w Capacity 8kWp
Daily Electri… Monthly Elec… Yearly Electr… Total Electri…
-- -- -- -- Local Weather
Ningbo SOC
Charge Battery Power Daily Charge Monthly Char… Annual Charge Total Charge 18℃
Rain
-- -- -- --
-4.00w Sunrise Sunset
Daily Dischar… Monthly Disc… Annual Disch… Total Discha… 05:49 18:07
-- -- -- --
Energy-saving and emission

Router Base station Router Base station Base station


Wi-Fi/4G
Wi-Fi GPRS/4G Wi-Fi 4G GPRS
Data
collector

Deye residential monitoring solution takes great care to ensure that your PV system is in excellent operation throughout its
DC AC Normal Alarm DC AC Normal Alarm

entire life-cycle. This monitoring solution offer you details information of your power generating plant including Today energy,
Monthly energy, yearly energy, total energy etc, through wireless communication with your router to the internet by a smart Smart energy controller Smart PV controller WiFi Smart PV controller
wifi plug. User can easily access to the monitoring page via PC web or phone APP.

Maximum your energy output while minimizing your costs. Scan the QR code to build your power station !

93 94
www.deyeinverter.com www.deyeinverter.com
Project cases
5KW
Brazil
SUN-5K-G

200KW
Brazil
SUN-50K-G

20KW
Brazil
SUN-10K-G

50KW 200KW
Brazil Vietnam
SUN-25K-G SUN-50K-G

95 96
www.deyeinverter.com www.deyeinverter.com
Project cases
32KW
320KW South Africa
Brazil SUN-8K-SG
SUN-80K-G

16KW
South Africa
SUN-8K-SG

25KW
Brazil 91KW
SUN-5K-SG USA
SUN 1300G2

97 98
www.deyeinverter.com www.deyeinverter.com
Project cases
48KW
Lebanon
SUN-12K-SG

24KW
Philippines
SUN-8K-SG

48KW
Lebanon
SUN-12K-SG
72KW
Lebanon
SUN-12K-SG

99 100
www.deyeinverter.com www.deyeinverter.com