-12 Appendix - summary of capacities

1 Hardware architecture
Box with 7 slots for installing communication (COM) boards and input/output (IO)
boards
RS232 115200 bps terminal port
CPU S550 Graphical screen + control thumbwheel
Infrared port
Dedicated 485-I/O port for communication with "S550-I/O” and “S50-I/O” expansion
modules
Box with 4 slots for installing 2 communication (COM) boards and/or 4 input/output
(IO) boards
CPU S530 RS232 115200 bps terminal port
Graphical screen + control thumbwheel
Box with 4 slots for installing 2 communication (COM) boards and/or 4 input/output
CPU S510 (IO) boards
RS232 115200 bps terminal port
10BT: 1 x 10 Mbit Ethernet link
PSTN: 1 x 33600 bps + VOICE PSTN link
GSM: 1 GSM Data (900MHz / 1800 MHz), SMS and GPRS link
DL/HF: up to 6 Radio, DL or PL, multi-point or point-to-point links
RDRTU-2: 1 x 869 MHz license-free Radio link
Communication boards (COM) RS-232
RS-485 up to 6 "1-channel" Serial links
RS-485i for controllers, meters, PLCs, etc.

DALLAS: up to 6 badge reader links


EDF: up to 6 EDF meter remote reading links
BATIBUS: 1 SIEMENS RVL/RWI and LPB controller link
8DI - counting (20 Hz) or rapid counting (300 Hz)
4AI (multistandard inputs) or 2AI (0-20 mA inputs)
Built-in Input/output (I/O) boards
4DO-wdg (max 50 VA outputs + Watchdog) or 2DO (max 50 VA outputs)
4AO (0-10V 4-20 mA outputs)
Up to 20 modules on one RS485 bus
(management of up to 60 “DI-Counter” data via these modules).
S550 I/O modules available:
 S550-16DI : 16 DI - 300 Hz counter inputs,
S550 I/O expansion modules
 S550-6DO : 6 DO - 250V – 1A monostable relay outputs
Watchdog function on terminal strip no. 6,
 S550-8AI-20 : 8 x 4-20 mA inputs – sensor power supply,
 S550-6AI-T° : 6 PT100/1000 or NI1000 inputs – 4-wire probes.

S500-nta_01-01_ANNEXE-CAPACITES -1-
2 Operator interfaces

Data (viewing via configured data groups, archived value curve display, time period
modification, setpoint definition)
Alarms (view log)
Interactive graphical display Operation (view log)
Hardware diagnostics (product, power supply, I/O and COM boards),
Time adjustment of the remote terminal unit

Viewing data groups (or all data), viewing archived value curves, log display (alarms
log, operating log, communications log)
Operation (modification of call numbers or Email addresses of PSTN/GSM/LAN
Browser recipients, setting remote terminal unit time)
Diagnostics (software or hardware), operating simulation, terminal mode,
PSTN/GSM receipt monitoring, TCP/IP communications test, call monitoring,
ST program monitoring, Serial, DL/HF, etc. link monitoring

VOICE server Viewing data groups and voice alarms


(via PSTN modem) Setpoint adjustment

SMS server Viewing data groups and alarms


(via GSM modem) Setpoint adjustment

S500-nta_01-01_ANNEXE-CAPACITES -2-
3 Software capacities
1,000 data (including reports and weekly periods)
50 groups of 20 data
5 voice groups
300 voice data
25 cyclical periods
General 25 weekly periods of 4 time periods
25 universal periods
50 exceptions
20 Look-up tables
10 lists of 10 numerical data labels
20 data archival criteria
25,000 value recording operations per remote terminal unit
last 200 events in the alarms log
last 200 messages in the communications log
Archiving
last 200 events in the operational log
(logical input-output status changes and messages generated by the "Waste
water disposal" and "Person identification" applications)
last 200 events relating to remote terminal unit operation in the diagnostics log
Formulae 50 formulae of 100 characters
255 process control programs
ST process controls 64 Kb maximum per ST program
300 kb (source + executable)
20 automatic call recipients
20 sequences of 8 recipients
PSTN / GSM communications 20 schedules (6 time bands per day)
20 exception periods
5 voice groups
Voice server 1,000 voice data
5 minutes of recording in total
4 LP-BOX or HF-BOX devices per link
SERIAL communications 30 MODBUS peripherals (PLC, RTU, PC, ...)
ETHERNET / DL-PL / RADIO 20 controllers / 500 communication data
100 thermal meters
Data reading from several EDF meters (up to 200 data)
(type YELLOW, BLUE, single-phase or three-phase, REMOTE REPORTING,
EDF remote reading type GREEN and SMC-SMI).

Management of 300 badges at the most


1 badge reader per DALLAS link
Person identification 1 "unrecognized badge" datum
50 groups of 30 badges
1 RS485 UNI-TELWAY serial link
Management of 10 servers
UNI-TELWAY communications Reading / writing of 1,000 communication data
Configuration of 200 data blocks
Writing on value change of 1,000 setpoints
Lifting station process control and management
(4 pumps maximum)
Waste water treatment Hourly reports over 10 days
Daily reports over 35 days
Wastewater network Connection of 2 CSV overflow sensors
self-monitoring Flow assessment via 1 level measurement sensor

S500-nta_01-01_ANNEXE-CAPACITES -3-