Industrial Solenoid Valve Guide

This document provides technical specifications for ICO3S 3/2 Exia poppet valves that can be directly operated by solenoids. The valves are available in different port sizes and configurations, with operating pressures up to 12 bar and temperature ranges from -55 to 69 degrees Celsius. Key features and dimensions are outlined.

Uploaded by

kev Y
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views3 pages

Industrial Solenoid Valve Guide

This document provides technical specifications for ICO3S 3/2 Exia poppet valves that can be directly operated by solenoids. The valves are available in different port sizes and configurations, with operating pressures up to 12 bar and temperature ranges from -55 to 69 degrees Celsius. Key features and dimensions are outlined.

Uploaded by

kev Y
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

ICO3S - 3/2 Exia poppet valves

Electromagnetically actuated, direct solenoid operated

> Port size: 1/4” or hydraulic operated


(ISO G/NPT) equipment
> Direct acting - > Global Approvals
intrinsically safe IECEX, ATEX, FM, CSA,
solenoid valve TRCU, NEPSI
> Reliable and long life, > Safety integrity level
ideal for a one time SIL 2 / SIL 3 (SIL 4
installation redundant
> A direct solenoid configuration only)
operated valve for the > Environmental
control of pneumatic protection:
NEMA 4X, IP66/X8

Technical features
Medium: Mounting position: Temperature: Materials:
Hydraulic and pneumatic – Solenoid vertical Media: Valve body, trim, coil housing
customer to specify and confirm Flow: -55 ... +69°C (-67 ... 156°F) and top cover:
compatibility 0,6 Cv (8,7 Kv) Ambient: stainless steel 1.4404 (316 L)
Operation: Port size: See table below O-rings seats & seals: high NBR
Direct solenoid operated 1/4 NPT, G1/4 Air supply must be dry enough to
poppet valves Operating pressure: avoid ice formation at temperatures Other seal materials available on
0 ... 12 bar (0 ... 174 psi) below +2°C (+35°F). request

Technical data - standard models


Symbol Port size Function Operating Manual Conduit ATEX Temperature range Weight Dimension Model
pressure override/ connection Media Ambient (kg) No.
(bar) reset (°C) (°C)
2 1/4 NPT 3/2 NC 0 ... 12 Without M20 x 1,5 Ex II 2 GD, Ex ia IIC -55 … +69°C -60 … +69°C 2,0 1 YX13AA1H1BS
GV-32C-E-F
1/4 3/2 NC 0 ... 12 Without M20 x 1,5 Ex II 2 GD, Ex ia IIC -55 … +69°C -60 … +69°C 2,0 1 YX13AE1H1BS
1 3

2 2 1/4 NPT NAMUR 3/2 NC 0 ... 12 Without M20 x 1,5 Ex II 2 GD, Ex ia IIC -55 … +69°C -60 … +69°C 2,0 3 YX13ANAH1BS
GV-32C-EH-F
1/4 NAMUR 3/2 NC 0 ... 12 Without M20 x 1,5 Ex II 2 GD, Ex ia IIC -55 … +69°C -60 … +69°C 2,0 3 YX13ANEH1BS
1 3

2 1/4 NPT 3/2 NC 0 ... 12 PBMR*1) M20 x 1,5 Ex II 2 GD, Ex ia IIC -55 … +69°C -60 … +69°C 2,5 2 YX13PA1H1BS
2
GV-32C-ER-F
1/4 3/2 NC 0 ... 12 PBMR*1) M20 x 1,5 Ex II 2 GD, Ex ia IIC -55 … +69°C -60 … +69°C 2,5 2 YX13PE1H1BS
1 3
1 3
2 2 1/4 NPT NAMUR 3/2 NC 0 ... 12 PBMR*1) M20 x 1,5 Ex II 2 GD, Ex ia IIC -55 … +69°C -60 … +69°C 2,5 4 YX13PNAH1BS
G 1/4 NAMUR 3/2 NC 0 ... 12 PBMR*1) M20 x 1,5 Ex II 2 GD, Ex ia IIC -55 … +69°C -60 … +69°C 2,5 4 YX13PNEH1BS
1 3

*1) PBMR = Push button manual reset

Technical data – solenoid operators


Nominal voltages 12 V d.c. via an energy limiting barrier Power consumption 0,43 watts typical
Operating current >=32mA Voltage protection Surge suppression diodes fitted as standard
Response times Pull-in 3 ... 4 seconds, drop out < 60 ms Coil encapsulation Class H
Drop out current >=6mA Leak performance Bubble tight at 50°C < 30 cc/m at -55°C
Coil rating 293 ohms Coil duty cycle 100%

05/19
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice,
the specifications given in this document. (2012 - 5196d) © IMI Precision Engineering, Thompson Valves Ltd. en 5.7.530.01
ICO3S - 3/2 Exia poppet valves
Electromagnetically actuated, direct solenoid operated

Dimensions Dimensions in mm
Projection/First angle
1 47 ø 58

28
2

22
157
3
2

39
1
27

26
15

16
6

11 25
27
50

2
47 ø 58

1
28

2
22
157

3
2
39

1
27

26
15

16
6

11 25
3

3
27
50

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 Manual reset

Our policy is one of continued research and development. We therefore reserve the right to amend, without 
en 5.7.530.02 notice, the specifications given in this document. (2012 - 5196d) © IMI Precision Engineering, Thompson Valves Ltd. 05/19
ICO3S - 3/2 Exia poppet valves
Electromagnetically actuated, direct solenoid operated

Dimensions in mm
3 Projection/First angle
47 ø 58

28
2

22

157
1

39
5,5
36

3
14

16
12
12

19,5 1,6 51
32 64

4
47 ø 58

28
2
22

157

1
39
5,5
36

3
14

16
12
12

19,5 1,6 3 51
32 64

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 Manual reset

Warning
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes of all
systems only. Do not use these products where pressures and component parts used in fluid power systems and to provide adequate
temperatures can exceed those listed under safeguards to prevent personal injury or damage to equipment in the
»Technical features/data«. event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in the system
for non-industrial applications, life-support systems or other instructional manual if protection against a failure mode cannot be
applications not within published specifications, consult adequately provided.
IMI Precision Engineering, Thompson Valves Ltd. System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in fluid warnings found in instruction sheets packed and shipped with these
power systems can fail in various modes. products.
For further information please see Functional Safety Manual MI0560.