Concrete Mix Design Report
Concrete Mix Design Report
CHAROLI
TEST FOR AGGREG
AGGREGATE BLENDING -
0.51
IS SIEVE CUM. % PASSING IN MATERIAL CUM. % PASSING
mm 20mm 10mm RS Cr.S 20mm
26%
ALL-IN-AGGREGATE A
ALL-IN-AGGREGATE A
100
80
CUM. % PASSING
60
40
20
0
0 1
IS SEIVE S
CHAROLI
ST FOR AGGREGATES
DATE :
TESTED BY : ZNS
25 30 19 100 100
25 30 19 2 95
25 30 19 85
24 30 19 76
17 30 19 67
2 30 18 4 30
0 23 15 38
0 14 10 24
0 11 6 5 10
0 7 3 10
0 5 2 7 0
0 3 1 4
AGGREGATE ANALYSIS
AGGREGATE ANALYSIS
10 100
IS SEIVE SIZE,mm
Lab incharge
IS : 383
LIMITS
100
100
50
35
6
100
STRONG TECH ENGINEERING SERVICES & RESEARCH (I) PVT. LTD.
Combine Gradation
% Passing % Blending
IS Sieve mm
20mm 10mm 20mm 10mm Actual Total Limits Remark
60% 40% 100
40 100.0 100.00 60.00 40.00 100.00 100
20 95.38 100.00 57.23 40.00 97.23 90-100
10 1.41 75.84 0.85 30.34 31.18 25-55
4.75 0.00 2.84 0.00 1.136 1.14 0-10
Combine Gradation
120
100
80 IS Limit
IS Limit
Percentage
60 Actual Testing
40
20
0
4.75mm 10mm 20mm 40mm
Authorized Signatory
Rajaram Pujari
(Technical Manager)
Home Page
STRONG TECH ENGINEERING SERVICES & RESEARCH (I) PVT. LTD.
All in Aggregate ( IS-383-2016)
Blending for All in Aggregate-As per IS-383-2016 (Nominal Maximum Size is 20mm)
100
IS Limit
80
Percentage
IS Limit
60 Actual Testing
40
20
0
150 mic 600 mic 4.75 mm 20 mm 40 mm
Home Page Design Mode- Auto
Concrete Mix Design
A. DESIGN MIX STIPULATION : B. MATERIAL TEST D
1 ) Grade of designation : M 40
2 ) Type of Concrete : Plain Concrete 1)
3 ) Characteristic Comp. Strength required in field at 28 : 40N/mm² 2)
4 ) Maximum size of aggregate(mm) : 20 3)
5 ) Degree of Quality Control : Good 4)
14 )
1
15 )
16 )
1 ) Admixture use : Yes 17 )
2 ) Flyash / GGBS use Fly Ash : No 18 )
3 ) 10 mm use : Yes 19 )
4 ) Crushed Sand use : Yes 20 )
5 ) River Sand use : No 21 )
6 ) Reduce of Water : 17 22 )
7 ) Percentage of Fly Ash : 0 23 )
24 )
Combine gradition
120
100 120
IS Limit
80 100
centage
IS Limit
60 80
40 Actual Testing 60
Combine gradition
120
100 120
IS Limit
80 100
Percentage
IS Limit
60 80
40 Actual Testing 60
20 6 40
0 20
4.75mm 10mm 20mm 40mm 0
150 mi
All in Aggregate
120
100 IS Limit
centage
80 IS Limit
60 Actual Testing
All in Aggregate
120
100 IS Limit
Percentage
80 IS Limit
60 Actual Testing
40
20
0
150 mic 600 mic 4.75 mm 20 mm 40 mm
Fine agg.
0.438
PM 1:34 AM
OPC 53
196
%
%
%
%
IS Limit
IS Limit
Actual Testing
IS Limit
IS Limit
Actual Testing
40 mm
Fly Ash
Admixture
10 mm
Crushed Sa
River Sand
W/c
Yes 1
No 0
No 0 0
Yes 1 0 1 2 1
Yes 1 0 0 1 1
Yes 1 0 1 1 0 0
No 0 0
1 Hence OK 1
1 Hence OK 1
0 0 Hence NOT 0
CONCRETE MIX DESIGN CALCULATION (IS 10262:2019)
Report No:- ST220204-10-01
Client Name :- PBG Concretes
Site/Project Name &
Location :-
PBG Concretes, Bavdhan, Pune
Sample Condition :- Acceptable
Date of Receipt :- 2/4/2022
Date of Testing :- 3/1/2022
References :- IS10262-2019, IS:456-2000 & IS:383 – 2016
Page 17 of 38
C. TARGET MEAN STRENGTH OF CONCRETE:
Required Target mean strength in 28 days, For a Tolerance Factor of 1.65 (Using IS : 456-2000) and
Standard Deviation equals to 5.0 (Using IS: 456-2000), the Target Mean compressive Strength
for the specified characteristic cube strength is:
a) f'c k = fck + 1.65s b) f'c k = fck + X
= 40 + 1.65 x 5.0 = 40 + 6.5
= 48.25 N/mm² = 46.5 N/mm²
Therefore,Target Mean Strength = 48.25 N/mm²
The higher value is to be adopted.Therefore,target strength will be 48.25N/mm² as 48.25N/mm² > 46.5N/mm²
APPROXIMATE AIR CONTENT
From Table 3,the approximate amount of entrapped air to be expected in normal (non-air-entrained) concrete is 1.0 percent for 20mm
nominal maximum size of aggregate
Grade curve .This is lower than the the maximum value of 0.40 prescribeb for severe' exposure for rainforced
concrete as per Table 5 of IS 456.
0.38<0.4 Hence OK
Page 18 of 38
G. PROPORTION OF VOLUME COARSE AGGREGATE AND FINE AGGREGATE CONTENT :-
From table 5, volume of coarse aggregate corresponding to 20mm size aggregate and fine aggregate
(Zone I) for water cement ratio of 0.50=0.60
In the present case water cement ratio is 0.38 Therefore, volume of coarse aggregate is required to be
increased to decrease the fine aggregate content. As the w/c ratio lower by 0.12 , the proportion of
volume of coarse aggregate is increased by 0.024 .( at the rate of -/+0.01 for every +/-0.05 change in water
cement ratio )
Therefore volume of coarse aggregate is = 0.624
For Pumping or desirable cohesive and workable mix Coarse aggregate Reduce
by 10% Hence = 0.62 x 0.9= 0.562
Volume of fine aggregate = 1 - 0.56 = 0.438
H. MIX CALCULATION :-
A) Volume of concrete = 0.99 m3 { Volume of entrapped air in wet concrete=0.01m3, Net Volume=(1-0.01)m3}
B) Volume of cement = (Mass of cement / Specific gravity of cement ) * 1/1000
= ( 432 / 3.15 ) * 1/1000
= 0.137 m3
= {(1-0.01)-0.137+0.164+0.0036)}
= 0.685 m3
F) Volume of 10mm aggregate = 0.685 x 0.225 x 2.89 x 1000
= 445 kg/m3
G) Volume of 20mm aggregate = 0.68500 x 0.337 x 2.91 x 1000
= 672 kg/m3
H) Volume of C.Sand = 0.685 x 0.438 x 2.75 x 1000
= 826 kg/m3
I) Volume of R.Sand = 0.685 x 0.000 x 2.76 x 1000
= 0 kg/m3
Page 19 of 38
I. INGREDIENT PER CUM :-
Page 20 of 38
Strong Tech Engineering Services & Research (I) Pvt. Ltd.
TRIAL MIX
Report No. ST220204-10-01 DATE OF RECIEPT 2/4/2022 DATE OF TRIAL 3/1/2022
CEMENT TYPE AND GRADE Ultratech OPC 53 TRIAL NO. 1
GRADE OF CONCRETE M 40 BATCH VOLUME 0.025
NAME OF ADMIXTURE BASF 8352 % OF DOSES 1.00%
Cover Letter
Sample ID No. :- 0
Client Name :- PBG Concretes
Site/Project Name & Location :- PBG Concretes, Bavdhan, Pune
Sample :-
1)Condition :-
Acceptable
Date of Receipt .
Date of Testing 3/10/2022
References IS10262-2019, IS:456-2000 & IS:383 – 2016
Note
1) The above mix design requires certain control practices on site to ensure results.
2) Any change in materials like cement, sand or aggregate, and plasticizer would require re-validation of design.
3) This Trial mix is recommended as mix found to be homogeneous, workable and economical in terms of
cement consumption.
4) Design quantities are based on properties of materials as found in laboratory and degree of quality control “
Good ” expected to be followed at site as per design data provided by the customer.
5) The water used for mixing of concrete at site should conform to specification of IS:456-2000.
6) Moisture content corrections in aggregate should be made corrected for water and aggregate and it should
be carried out before preparation of concrete.
7) This mix has been designed for a slump of (Initial)0 , in saturated surface dry condition of the aggregate and if
slump found more at site which indicates excess free water content in the mix and results in lower strength at
specified age as well as concrete mix may be seggregated
Authorized Signatory
Rajaram Pujari
(Technical Manager)
Test Report - Compressive Strength of Concrete Cube
Report No.
Sr.
Size of Cubes C/s Area Volume Weight Density of
Compressive
No. of Cubes of Cubes (gm) Cubes
(mm²) (cm³) (Kg/m³) Load Strength Avg. Strength
L W H (KN) (N/mm²) (N/mm²)
1 150.7 151.6 149.4 22846.1 3413.2 8865 2597.3 254.2 11.13
2 150.8 151.0 149.8 22770.8 3411.1 8965 2628.2 263.1 11.55 11.37
3 149.9 150.3 151.3 22530.0 3408.8 9022 2646.7 257.8 11.44
As per ( IS: 456 -2000 Exp Handbook ) SP 24-1983 required minimum strength of concrete for
Remark :-
M-10 Grade at 7 days is 6.65 N/mm²
Authorized Signatory
Rajaram Pujari
( Technical Manager)
Plastic
For Cement Fly Ash Crushed River Sand 10 mm 20mm Water Admixture Density
Sand
(Kg/m3)
Remark:- 1) Mix observed good cohesive /homogeneous & Workable Authorized Signatory
2) Compressive Strength is satisfactory achived
3) This mix designs is prepared by IS:10262-2019 as well as trials for the same.
4) Before use take a trial and revert us if any
Rajaram Pujari
(Technical Manager)
End of report Page 1 of 1
Test Report - Compressive Strength of Concrete Cube
Accelerated Curing Test (IS: 9013)
Report No. ST220204-10-01
Client name :- PBG Concretes
Project/Site :- PBG Concretes, Bavdhan, Pune
Grade of concrete :- M 40
Date of Report:- 3/2/2022
Date of Receipt 2/4/2022
Date of Casting :- 3/1/2022
Date of Testing :- 3/2/2022
Age of cubes in days :- 1
References :- IS:516-1959 ( Reaffirmed-2013), IS:456-2000, SP24-1983
Authorized Signatory
Rajaram Pujari
(Technical Manager)
Sr.
Size of Cubes
C/s Area of Volume of Weight
Compressive
No. Cubes (mm²) Cubes (cm³) (gm) Load Strength Avg. Strength
L W H (KN) (N/mm²) (N/mm²)
1 150.5 150.6 150.6 22660.8 3413.2 8887 790.2 34.9
2 150.4 150.5 150.7 22633.7 3410.7 8845 760.5 33.6 34.86
3 149.7 149.5 150.1 22378.7 3358.8 8813 807.9 36.1
Authorized Signatory
Rajaram Pujari
(Technical Manager)
Sr.
Size of Cubes
C/s Area of Volume of Weight
Compressive
No. Cubes (mm²) Cubes (cm³) (gm) Load Strength Avg. Strength
L W H (KN) (N/mm²) (N/mm²)
1 151.0 151.1 151.6 22814.6 3458.5 8745 1227.4 53.8
2 150.9 150.9 151.4 22776.8 3449.3 8685 1179.8 51.8 53.23
3 150.2 149.9 150.8 22521.0 3397.1 8587 1218.4 54.1
Authorized Signatory
Rajaram Pujari
(Technical Manager)
1 10.0 mm 0 0 0 100
2 4.75 mm 18 1.69 1.69 98.31
3 2.36 mm 374 35.05 36.74 63.26
4 1.18 mm 307 28.77 65.51 34.49
5 600 µ 77 7.22 72.73 27.27
6 300 µ 70 6.56 79.29 20.71
7 150 µ 50 4.69 83.97 16.03
8 PAN 171 16.03 100 0.00
9 Total Wt. 1067 F.M= 3.40
Obs.No. 9
Inward No. 2776 Sample ID No. 1162/1
Date of Receipt 1/2/2017 Date of Testing 1/5/2017
Sample Description C.A (20mm)
63-50 - - - - - - - -
50-40 0 0 0.00 0 0 0 0
40-31.5 0 0 0.00 0 0 0 0
31.5-25 0 0 0.00 0 0 0 0
25-20 270 270 5.40 20 7 0 0
20-16 2754 1968 39.36 56 2.85 1.12 133
16-12.5 1803 1092 21.84 25 2.29 0.50 215
12.5-10 173 173 3.46 8 4.62 0.16 54
10-6.3 - - - - -
Total 5000 2.18 402
Flakiness Index 2.18 %
Elongation Index 8.04 %
Combine Index 10.22 %
STRONG TECH ENGINEERING SERVICES & RESEARCH (I) PVT. LTD.
Coarse Aggregate Physical Test(10mm) - IS : 2386-1963 (Part -1)
Obs.No.
Inward No. Sample ID No. 619/2
Date of Receipt Date of Testing
Sample Description
63-50 - - - - - - - -
50-40 - - - - - - - -
40-31.5 - - - - - - - -
31.5-25 - - - - - - - -
25-20 - - - - - - - -
20-16 #VALUE! 0 #VALUE! -
16-12.5 #VALUE! 0 #VALUE! -
12.5-10 #VALUE! 0 #VALUE! -
10-6.3 #VALUE! 0 #VALUE! -
Total 0 #VALUE! 0 -
Flakiness Index #VALUE! %
Elongation Index #DIV/0! %
Combine Index #VALUE! %
STRONG TECH ENGINEERING SERVICES & RESEARCH (I) PVT. LTD.
Home Page
Coarse Aggregate(20mm) Physical Test Form
Obs.No. 94
Inward No. 2776 Sample ID No. 1162/1
Date of Receipt 1/2/2017 Date of Testing 1/5/2017
Sample Description C.A (20mm)
3 Weight of Saturated Surface Dry (SSD) Sample in Water (A) =(A1- A2 ) 1439
1 Weight of oven dried sample passing though 25mm and retained on 3320
20mm IS Sieve (A)
2 Weight of fraction passing though _______mm IS sieve (B) 575
3 Aggregate Crushing Value (%) = (B/A) × 100 17.32
STRONG TECH ENGINEERING SERVICES & RESEARCH (I) PVT. LTD. Home Page
Coarse Aggregate(10mm) Physical Test Form
Obs.No. 52
Inward No. 1298/76 Sample ID No. 619/2
Date of Receipt 7/12/2016 Date of Testing 7/14/2016
Sample Description C.A (10mm)
3 Weight of Saturated Surface Dry (SSD) Sample in Water (A) =(A1- A2 ) 1384
1 Weight of oven dried sample passing though 12.5 mm and retained 3208
on 10 mm IS Sieve (A)
2 Weight of fraction passing though _______mm IS sieve (B) 459
3 Aggregate Crushing Value (%) = (B/A) × 100 14.31
All in Aggregate Gradation ( IS: 383-1970 Table - 5 )
Crushed
Aggregates River Sand 20 mm 10 mm
Sand Specific
Combined
Proportion in % 23.00 23.00 33.48 20.52 % Passing
Limits MSA
Ratio 0.23 0.23 0.33 0.21 20 mm
IS Sieve (mm) % Passing
80 100 100 100 100 100 --
40 100 100 100 100 100 100
20 100 100 94.62 100 98.20 95-100
4.75 98.31 79.13 0.24 #VALUE! #VALUE! 30-50
0.600 27.27 18.27 - - 10.47 10-35
0.150 16.03 2.21 - - 4.19 0-6
STRONG TECH ENGINEERING SERVICES & RESEARCH (I) PVT. LTD.
CONCRETE MIX PROPORTIONING (IS 10262:2009)
F. CALCULATION OF CEMENT :-
Cement Content = 431 kg/m3
For Pumping Coarse aggregate Reduce by 10% Hence = 0.60 x 0.9 = 0.54
Volume of fine aggregate = 1 - 0.54 = 0.46
H. MIX CALCULATION :-
A) Volume of concrete = 1 m3
B) Volume of cement = (Mass of cement / Specific gravity of cement ) * 1/1000
= ( 431 / 3.15 ) * 1/1000
= 0.137 m3