0% found this document useful (0 votes)
946 views80 pages

Runxin ManuL F71Q1 55504

The document provides user manuals for multi-functional flow control valves used in water treatment systems, including information on product overview, basic settings, usage instructions, and notices.

Uploaded by

fofo992.milis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
946 views80 pages

Runxin ManuL F71Q1 55504

The document provides user manuals for multi-functional flow control valves used in water treatment systems, including information on product overview, basic settings, usage instructions, and notices.

Uploaded by

fofo992.milis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 80

International Patent Public No.

:
WO 2006/007772
China Patent No.: ZL201520680239.8
US Patent No.: 7549446
India Patent No.: 232582
Russia Patent No.:2349819
South Korea Patent No.:10-0914137
Mexico Patent No.: 268581
Australia Patent No.: 2005263257
Philippine Patent No.: 1-2006-502553
Taiwan Patent No.:M287896

Multi-functional Flow Control Valve for


Water Treatment Systems
55504 (Old Model No.:F67Q1)
55604 (Old Model No.:F67Q3)
55502 (Old Model No.:F71Q1)
55602 (Old Model No.:F71Q3)
75504 (Old Model No.:F68Q1)
75604 (Old Model No.:F68Q3)
75502 (Old Model No.:F69Q1)
75602 (Old Model No.:F69Q3)
65505 (Old Model No.:F116Q1)
65605 (Old Model No.:F116Q3)
65503 (Old Model No.:F117Q1)
65603 (Old Model No.:F117Q3)

User Manual
Please read this manual in details before using the valve and
keep it properly in order to consult in the future.
0WRX.466.212
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Before the valve put into use, please fill in the below content for
future reference.

The Program Type Setting (Operation by professional)

When all symbols light on, press and hold and buttons for 5
seconds to enter the menu of valve model selection. Please set the
program type in accordance with the product type. (Time clock type
by days or meter type, for example,F67Q1 should be set as 67Q1;
F67Q3 should be set as 67Q3 etc., it should not be set to other type.)

Softener System Configuration

Tank Size:Dia. mm,Height mm;


Resin Volume L;Brine Tank Capacity L;
Hardness of Raw water mmol/L;
Pressure of Inlet Water MPa;
Control Valve Model ;Number ;
Specifications of Drain Line Flow Control ;
Injector No. .
Water Source: Ground-water□ Filtered Ground-water □Tap Water □
Other .

Filter System Configuration

Tank Size:Dia. mm,Height mm;


Filter Material Kg; Filter Material Height mm;
Turbidity of Inlet Water FTU;
Pressure of Inlet Water MPa;
Control Valve Model ;Number ;
Water Source: Ground-water□ Filtered Ground-water □Tap Water □
Other .

Parameter Setting
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Factory Actual
Parameter Unit
Default Value
Control Mode A-01/02 (Q3 meter
/ A-01
type available)
Unit Mode HU-1/2 (Q3 meter type
/ HU-1
available)
Water Treatment Capacity (Q3
m3 10
meter type available)
Service Days (Time type by day) D. 03
Regeneration Time / 02:00
Backwash Interval Times
/ F-00
(F68Q/F69Q available)
Rinsing Frequence (F67Q/F71Q
/ F-00
available)
Backwash Time min. 10
Brine & Slow Rinse Time
min. 60
(F67Q/F71Q unavailable)
Brine Refill Time
min. 05
(F67Q/F71Q unavailable)
Fast Rinse Time min. 10
Interval Regeneration Days
D 30
(Q3 meter type available)
Output Mode b-01(02) / b-01
 If there is no special requirement when product purchase, F68Q is
without the drain line flow control,and choose 8# injector as the
standard configuration. We choose 8468077 drain line flow control,
and 4# injector for F69Q as standard configuration. F116Q is without
the drain line flow control,and choose 9# injector as the standard
configuration. We choose 8468062 drain line flow control,and 7#
injector for F69Q as standard configuration.
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Catalogue
Notice ................................................................................................................... 1
1. Product Overview........................................................................................... 3
1.1. Main Application & Applicability .......................................................... 3
1.2. Product Characteristics........................................................................... 3
1.3. Service Conditions ................................................................................. 6
1.4. Product Structure and Technical Parameters .......................................... 7
1.5. Installation ............................................................................................ 12
2. Basic Setting & Usage ................................................................................ 16
2.1. The Function of PC Board ................................................................... 16
2.2. Basic Setting & Usage(F116Q3 A-01 as example) .......................... 20

I
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Notice
 To ensure normal operation of the valve, please consult with
professional installation or maintenance personnel before using it.
  If there is any pipeline engineering and electric works, it must be
finished by professional at the time of installation.
 Do not use the control valve with the unsafe or the quality-unknown
water.
 Depending on the changing of working environment and water
requirement, each parameter of softener should be adjusted accordingly.
 When the water treatment capacity is too low, please check the resin. If
the reason is shortage of resin, please add; if the resin turns to reddish
brown or broken, please replace.
 Test water quality periodically to verify that system is performing
satisfactorily.
 Sodium used in the water softening process should be considered as
part of your overall dietary salt intake. Contact your doctor if you are on a
low sodium diet.
 When this valve is used for softening, please ensure the solid salt is
available in the brine tank all the time during use. The brine tank should
be added by the clean water softening salts only, at least 99.5% pure,
forbidding use the small salt.
 Do not put the valve near the heat resource, high humidity, corrosive,
intense magnetic field or intense librations environment. And do not
leave it outside.
 Forbidden to pull the injector body. Avoid to use injector body as
support to carry the system.
 Forbidden to use the brine tube or other connectors as support to carry
the system.

1
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

 Please use this product under water temperatures between 5~50℃,


water pressure 0.15~0.6MPa. Failure to use this product under such
conditions voids the warranty.
 If the water pressure exceeds 0.6MPa, a pressure reducing valve
must be installed in front of the water inlet. While, if the water pressure
under 0.15MPa, a booster pump must be installed in front of the water
inlet.
 It is suggested to install PPR pipe, corrugated pipe or UPVC pipe,
instead of TTLSG pipe.
 Do not let children touch or play, because carelessness operating may
cause the procedure changed.
 When the attached cables of this product and transformer are changed,
the replaced must come from our factory.

2
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

1. Product Overview

1.1. Main Application & Applicability

Used for intelligent filtering, demineralization and softening in the water


treatment systems.
F67Q/F71Q (Filter)
Residential filtration system
RO pretreatment active carbon and sand filtration system, etc.
F116Q/F117Q (Down-flow regeneration) , F68Q/F69Q (Up-flow
regeneration)
Applicable for the ion exchange equipment which hardness
of the raw water ≤6.5mmol/L
Boiler softening water system
RO pretreatment softening system, etc.

1.2. Product Characteristics

 Simple structure and reliable sealing


The distribution valve adopts hermetic head faces with high degree
pottery and corrosion resistance for opening and closing. It combines
with Service, Backwash, Brine & Slow Rinse, Fast Rinse and Brine Refill.
 No water pass the valve in regeneration in single tank type.
 Manual function
Realize regeneration immediately by pushing manual button at
any time.
 Long outage indicator
If outage overrides 3 days, the time of day indicator “12:12” will flash
to remind people to reset new time of day. The other set parameters do

3
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

not need to reset. The process will continue to work after power on.
 The valve will automatically rotate for more than ten seconds
after it is power on
After the valve power on, it will automatically rotate for more than
ten seconds to turn back to the position when the electricity is cut off.
 Buttons lock
No operations to buttons on the controller within 1 minute, button
lock indicator lights on which represents buttons are locked. Before
operation, press and hold the “ ”and“ ” buttons for 5 seconds to
unlock. This function can avoid incorrect operation.
 Interval backwash times (Suitable for F68Q/F69Q)
It could set up interval backwash times for F68Q/F69Q up-flow
regeneration valve, which means several times of services but one time
of backwash. The setting of interval backwash times depends on the
local water turbidity. (The lower the turbidity is, the longer of the interval
backwash times can be set)
 It can choose time clock type or meter type by program
selection
When all symbols light on, press and hold and buttons for 5
seconds to enter the menu of valve model selection. Please set the
program type in accordance with the product type. (Tim clock type by
days or meter type) (Notice: The meter type product has one flow meter
and flow meter cable, but the time clock type does not).
 Two meter types can be selected (Suitable for
F67Q3,F68Q3,F69Q3,F71Q3,F116Q3,F117Q3)
Model Name Instruction
Regenerate on the day although the available volume
Meter
A-01 of treated water drops to zero (0). Regeneration starts
Delayed
at the regeneration time.
Meter Regenerate immediately when the available volume of
A-02
Immediate treated water drops to zero(0).

4
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

 Interlock function
It has an interlock function to realize only one valve in regeneration
but the others are in service while several valves are in parallel
connection or in series connection in the system. In multi-steps
treatment systems such as RO pre-treatment, when several valves are
in series, there is only one valve in regeneration or washing to ensure
there is water passing all the times while different valves in regeneration
or washing. (Application refer to Figure 3-9)
 Signal Output (F116Q as example)
There is a signal output connector on the main control board. It is for
controlling external wiring (Refer to figures from Figure3-1 to Figure
3-8).
There are two kinds of output modes: b-01 Mode: Turn on when
regeneration started and shut off at the end of regeneration; b-02 Mode:
Signal available only at intervals of regeneration cycles and in service.

 User can set the maximum interval regeneration days (Only


for F67Q3/ F68Q3/F69Q3/F71Q3/F116Q3/F117Q3)
In the situation of service reaching the setting days but the volume
not yet, it could enter into regeneration process forcibly when current
time is the same as regeneration time.
 All parameters can be modified
According to the water quality and usage, the parameters in the
5
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

process can be adjusted.

1.3. Service Conditions

Runxin Valve should be used under the below conditions:


Items Requirement
Working Water pressure 0.15MPa~0.6MPa
Conditions Water temperature 5℃~50℃
Environment
5℃~50℃
Working temperature
Environment Relative humidity ≤95%(25℃)
Electrical facility AC100~240V/50~60Hz
Filter<20FTU
Water turbidity Down-flow regeneration<5FTU;
Up-flow regeneration<2FTU
Inlet Water First Grade Na+<6.5mmol/L;
Water hardness
Quality Second Grade Na+<10mmol/L
Free chlorine <0.1mg/L
Iron2+ <0.3mg/L
CODMn <2mg/L(O2)

In the above table, First Grade Na+ represents First Grade Na+
Exchanger. Second Grade Na+ represents Second Grade Na+
Exchanger.
 When the water turbidity exceeds the conditions, a filter should be
installed on the inlet of control valve.
 When the water hardness is exceeds the conditions, the outlet water
hardness will hardly reach the requirement of boiler feed water
(0.03mmol/L). It is suggested to adopt second grade softener.

6
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

1.4. Product Structure and Technical Parameters

A. Product dimension (The appearance is just for reference. It is


subject to the real product.)
F67Q1 structure chart:

7
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

8
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

9
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

B. Technical Parameters
F71Q1, F71Q3, F69Q1, F69Q3, F117Q1, F117Q3 control valves are
suitable for the power adapter output: DC12V, 1A, other models are
suitable for the power adapter output: DC12V, 1.5 A.
Connector Size
Flow Rate
Model Inlet Drain Brine Line Remark
m3/h
/Outlet Line Connector
Filter, time
F67Q1
clock type
G1 G1 / 4 (@0.3MPa)
Filter, meter
F67Q3
type
Filter, time
F71Q1
clock type
G3/4 G3/4 / 2 (@0.3MPa)
Filter, meter
F71Q3
type
Up-flow, time
F68Q1 G1 NPT3/4 G3/8 4 (@0.3MPa)
clock type

10
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Up-flow,
F68Q3
meter type
Up-flow, time
F69Q1
clock type
G3/4 NPT3/4 G3/8 2 (@0.3MPa)
Up-flow,
F69Q3
meter type
Down-flow,
F116Q1 time clock
G1 NPT3/4 G3/8 4 (@0.15MPa) type
Down-flow,
F116Q3
meter type
Down-flow,
F117Q1 time clock
G3/4 NPT3/4 G3/8 2 (@0.15MPa) type
Down-flow,
F117Q3
meter type

11
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

1.5. Installation

A. Installation notice
Before installation, read all those instructions completely. Then
obtain all materials and tools needed for installation.
The installation of product, pipes and circuits should be
accomplished by professional to ensure the product can operate
normally.
Perform installation according to relative pipeline regulations and
the specification of Water Inlet, Water Outlet, Drain Outlet, Brine Line
Connector.
B. Device location
① The filter or softener should be located close to the drain.
② Ensure the unit is installed in enough space for operating and
maintenance.
③ Brine tank needs to be close to softener.
④ The unit should be kept away from the heater, and not exposed
outdoor. Sunshine or rain will cause the system damage.
⑤ Please avoid to install the system in one acid/alkaline, Magnetic or
strong vibration circumstance, because above factors will cause the
system disorder.
⑥ Do not install the filter or softener, drain pipeline in circumstance
which temperature may drop below 5℃, or above 50℃.
⑦ The system should be installed in a place where there will be the
minimum loss in case of water leakage.

12
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

C. Pipeline installation (F116Q3 as example)


① Install control valve
a. As the Figure 1-1 shows, select the riser pipe with 26.7mm OD, glue
the riser pipe to the bottom strainer and put it into the mineral tank, cut
off the exceeding tube out of tank top opening. Plug the riser tube in case
of mineral entering.
b. Fill a stipulated amount of resin to the tank.
c. Screw the top strainer into the control valve.
d. Insert the riser tube into control valve and screw tight control valve.

13
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Notice:
● The length of riser tube should be neither higher 2mm nor 5mm lower
than the tank top opening, and its top end should be rounded to avoid
damage of O-ring inside the valve.
● Avoid floccules substance together with resin to fill in the mineral tank.
● Avoid O-ring inside control valve falling out while rotate it on the tank.
② Install animated connector
As Figure1-2 shows, put the sealing ring into nut of animated
connector, and screw in
water inlet.
③ Install flow meter
As Figure1-2 shows,
put the seal ring into nut
of flow meter, screw in
water outlet; insert the
sensor into flow meter.
④ Pipeline connection
a. As Figure1-3 shows, install a
pressure gauge in water inlet.
b. Install valve A, B, C and D in the
intermediate pipeline, inlet and
outlet. valve D is a sampling valve.
(Or adopt F70A/F70C bypass
valve).
c. Install a check valve in water
outlet.
d. Inlet pipeline should be in parallel
with outlet pipeline. Support inlet
and outlet pipeline with fixed holder.

Note:

14
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

●If the water outlet or water tank is installed higher than control valve or
parallel interlock system with multi-outlets, a liquid level controller must
be installed in brine tank, or install a check valve in water outlet. Or else,
the water in water outlet or water tank will flow backwards into
brine tank when backwash. The water in water outlet or water tank
will flow backwards into drain when brine refill — Suitable for
F68Q/F69Q/F116Q/F117Q.
●If use a soldered copper to install inlet/outlet pipes, do all sweat
soldering before connecting pipes to the valve. Torch heat will damage
plastic parts.
●When turning threaded pipe fittings onto plastic fitting, do not use
excessive force to make threads misaligned or break valve.
●If the valve belongs to time clock type, there is no step ② and ③
⑤ Install drain pipeline
a. As the Figure 1-4 shows,
slide the drain hose connector
into drain outlet.
b. Locate the drain hose well as
the Figure 1-4 show.

Note:
●Control valve should be higher
than drain outlet, and not far from the drain hose. If drain outlet higher
than control valve, a check valve must be installed in drain outlet. Or
else, the waste water will flow backwards into water outlet when
brine refill—Suitable for F68Q / F69Q / F116Q / F117Q.
● Be sure not to connect drain with sewer, and leave a certain space
between them, avoid waste water being absorbed to the water treatment
equipment, such as showed in the Figure1-4.
⑥ Connect brine tube
a. As Figure 1-5 shows, slide 3/8″ brine tube hose connector over end of

15
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

brine tube.
b. Insert tube bushing into the end of brine tube.
c. Tighten nut onto brine line connector.
d. Connect the other end of brine tube with the brine tank. (The liquid
level controller and air-blocker should be installed in the brine tank.)
Remark: The brine tube and drain pipeline should not be bended or
plugged.

2. Basic Setting & Usage

2.1. The Function of PC Board

Take time clock type valves F67Q1/F68Q1/F116Q1 and meter type


valves F67Q3/F68Q3/F116Q3 as example:

16
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

17
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

A.Button lock indicator


 When the fourth decimal point of digital tube turns on, it indicates the
buttons are locked. At this moment, pressing any single button will not
work (No operation in one minute, the fourth decimal point of the digital
tube will light on and lock the buttons).
 Solution:Press and hold both and for 5 seconds until the decimal
point lights off.
B. Time of day indicator
 When “:” flashes, it indicates the time of day.
C. Program mode indicator
 The third decimal point of digital tube turns on, it indicates the inquiry
mode. Use or to view all values.
 The third decimal point of digital tube flashes, it indicates the set mode.
Use or to adjust all values.
D. Menu/Confirm button
 In menu mode, press to enter inquiry mode, the third decimal point of
digital tube turns on.
 In inquiry mode, press and to enter set mode. Parameter to be set
flashes.
 Press after all program are set successful, and return to inquiry mode.
E. Manual/Return button
 In menu mode, press , it can proceed to next step. (Example: press
in service status, it will start regeneration cycles/washing instantly if
the outlet water is unqualified; Press while it is in
regeneration/washing status, it will end regeneration/washing and go to the
next status at once.)
F. Up and Down
 In program inquiry mode, press or to view all values.
 In program set mode, press or to adjust values.

18
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

 Press and hold both and for 5 seconds to unlock the buttons.
 In program set mode, press to return to program inquiry mode; in
program inquiry mode, press to return to menu mode.
 Press while adjusting the values, then it will return to program
inquiry mode directly without saving values. Press , it will save the
values and return to program inquiry mode.

19
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

2.2. Basic Setting & Usage (F116Q3 A-01 as

example)

A. Parameter specifications
Factory Parameter
Function Indicator Instruction
Default set range
00:00~ When use, enquiry and set,the time of
Time of Day ":"Flashes Random
23:59 day ":" flashes.
Regeneration 00:00~
":"Lighting 02:00 Regeneration time;":" lighting.
Time 23:59
Meter Delayed: Regenerate will not
start although the available volume of
A-01
treated water drops to zero (0) until at
Control the regeneration time.
/ A-01
Mode Meter Immediate : Regenerate
immediately when the available
A-02
volume of treated water drops to
zero(0).
Water
0~99.99 Water treatment capacity in one circle
Treatment m3 10.00m3
m3 (m3)
Capacity
Backwash
2- 10 0~99 Backwash time (minute)
Time
Brine &
Slow Rinse 3- 60 0~99 Brine & slow rinse time (minute)
Time
Fast Rinse
4- 10 0~99 Fast rinse time (minute)
Time
Brine Refill
5- 05 0~99 Brine refill time (minute)
Time
Maximum Regenerate at the regeneration time
H-30 30 0~40
Interval even though the available volume of

20
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Regeneration treated water does not drop to zero


Days (0).
b-01 : Signal turn on when
Output regeneration started and shut off at
Control b-01 01 01 or 02 the end of regeneration.
Mode b-02 : Signal available only in
intervals of each status.

B. Process Display (Take A-01 as example)

Figure A Figure B Figure C

Figure D Figure E Figure F

Figure G Figure H

Illustration:
 In Service status, the figure shows A/B/C/D. Figure C shows time of day, the
middle “:” flashes. Figure D shows regeneration time, the middle “:” turns
on;
 In Backwash status, it shows as figure E/C; In Brine & Slow Rinse status, it

21
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

shows as F/C; In Fast Rinse status, it shows as figure G/C; In Brine Refill
status, it shows as figure H/C. In each status, every figure shows 15 seconds.
 Above displays are taking the Meter Type F116Q3 A-01 for example. For the
Time Clock Type, it shows the rest days, such as 1-03D.
 The display screen will only show “-00-” when the motor is running.
 The time of day figure flashes continuously, such as “12:12” flashes, which
indicates long outage of power. It reminds to reset the time of day.
 The display will show the error code, such as “-E1-” when the system is in
error.
 F117Q/F116Q working process: Service → Backwash → Brine & Slow
Rinse → Fast Rinse → Brine Refill → Service.
 F68Q/F69Q working process: Service → Backwash → Brine & Slow
Rinse → Brine Refill → Fast Rinse → Service.
 F67Q/F71Q working process: Service → Backwash → Fast Rinse →
Service.

22
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

C. Usage

After the accomplishment of installation, parameter setting and trial


running by the professional, the valve can be put into use. In order to ensure
that the quality of outlet water can reach the requirements, the user should
complete the below work:
① Add the salt for regeneration in time to ensure the solid salt is always
available in brine tank. Only clean softening salt can be added to the brine tank,
at least 99.5% pure. It is forbidden to use fine salt and iodized salt.
② Test the outlet water and raw water hardness at regular intervals. When the
outlet water hardness is unqualified, please press the and the valve will
temporarily regenerate again (It will not affect the original set operation cycle)
③ When the feed water hardness changes a lot, you can adjust the water
treatment capacity as below:
Press and hold both and for 5 seconds to unlock the buttons.
Press , the third decimal point of digital tube lights on, then press to
choose the water treatment capacity, the digital area will show the given water
treatment capacity, such as 10.00m3. Press again, the water treatment
capacity “10.00” flashes, then press to reset the value. Press twice
and hear a sound “Di”, the adjustment finished. Press exit and turn back to
the service status.
④ For A-01 control mode (Delayed regeneration type), please pay attention
whether the time is current or not. If the time is not right, you can adjust as
below: After unlocking the buttons, press , the third decimal point of digital
tube lights on. Then press , the ":" and hour value flash. Press or
continuously to reset the hour value; Press again, ":" and minute value
flash. Press or continuously, reset the minute value; Press and hear
a sound “Di”, the adjustment finished. Press exit and turn back to the
service status.
The regeneration parameters have been set when control valve left the
factory. Generally, it does not need resetting. If you want to inquire and
23
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

modify the settings, you can refer to the professional application


specifications.

24
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

3. Applications

3.1. Flow Chart


 A. Filter

25
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Remark:
F68Q, F69Q working process: Service → Backwash → Brine & Slow Rinse
(Up-flow Regeneration ) → Brine Refill → Fast Rinse → Service.
F117Q, F116Q working process: Service → Backwash → Brine & Slow
Rinse (Down-flow Regeneration ) → Fast Rinse → Brine Refill → Service.

3.2. The Function and Connection of PC Board

Opening the front cover of control valve, you will see the main control board
and connection parts as below:

26
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

The main functions on main control board:


Function Application Explanation
Used in strictly requirements regarding no
Outlet solenoid
hard water flowing from outlet or control
valve
Signal output the liquid level in water tank.
connector Increase pressure for regeneration or
b-01 washing.
Inlet pump
Use the liquid level controller to control
inlet pump to ensure there is water in tank.
Signal output Inlet solenoid When inlet pressure is high, it needs to
connector valve or inlet close water inlet to protect motor when
b-02 pump valve is rotating.
To ensure only
Use in RO Pre-treatment, water supply
one control valve
Interlock together but regeneration in turn. Second
in regeneration
connector grade ion exchange equipment, etc.
or washing in
system.

A. Signal Output Connector


1) Control Solenoid Valve (Set as b-01)
①Solenoid Valve on Outlet Controls Water Level in Brine Tank.

27
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Instruction: If system requires no hard water to flow from outlet in regeneration


cycle (Mainly for no hard water flows out when valve is switching or valve in
backwash or brine drawing status), a solenoid valve could be installed on outlet,
the wiring refers to Figure 3-1.

Function:
When valve in service status, if soft water tank is shortage of water,
solenoid valve will open to supply soft water, but if water tank has enough
water, solenoid valve will close, so no soft water will be supplied to the tank.
When the valve is in backwash or other regeneration status, there is no
signal output. So, solenoid valve will close, and no raw water flows into soft
water tank.
② Solenoid Valve on Inlet (Set as b-02)
Instruction: When inlet pressure exceeds 0.6MPa, install a solenoid valve on
inlet. Control mode is b-02. Pressure will be relieved when valve is switching,
the wiring refers to Figure 3-2. As Figure 3-3 shows, it also can use the
pressure relief connector to work.

28
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Function:
When inlet pressure is high, install a solenoid valve on inlet to ensure
valve switching properly. When valve is exactly in status of Service, Backwash,
Brine & Slow Rinse, Fast Rinse and Brine Refill, solenoid valve is open. When
valve is switching, solenoid valve is closed, no water flows into valve to ensure
valve switching properly. It could prevent the problem of mixing water and
water hammer.
Use interlock cable to realize valves in parallel or series connection in the
same system which is suited for RO pretreatment system or second grade Na+
system. The wiring refers to Figure 3-4:

2) Liquid Level Controller Controls Inlet Pump (Two-phase motor) (Set as


b-01)
Instruction: For the system using well or middle-tank supplying water,
switch of liquid level controller and valve together control pump opening or
closing. The wiring refers to Figure 3-5:

29
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Function:
When valve is in service status, if water tank is short of water, pump starts
working. If water tank has enough water, the switch of liquid level controller
is closed, so pump does not work.
When valve is in regeneration cycle, no matter what water condition is in
water tank, open the pump to make sure there is water on inlet. As Runxin
valve no water passes outlet in regeneration cycle, it ensures no water fill into
brine tank.
A liquid switch at the top opening well or in middle water tank in RO
system protects pump from working without water in case of out of raw water.
3) Liquid Level Switch in Water Tank Controls Inlet pump (Three-phase
motor, Figure 3-6) (Set as b-01)

30
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

4) Control Inlet Booster Pump (Set as b-01 or as b-02)


Instruction: If inlet water pressure is less than 0.15MPa, which makes rinse
drawing difficult, a booster pump is suggested to be installed on inlet. Set
Control mode as b-01. When system in regeneration cycle, booster pump is
open, the wiring refers to Figure 3-7. If the booster pump current is bigger than
5A, system needs to install a contactor, the wiring refers to Figure3-8

31
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

B. Interlock

Instruction:
In the parallel water treatment system, it ensures only one valve in
regeneration or washing status and (n-1) valves in service, that is, realizing the
function of supplying water simultaneously and regenerating individually, the
wiring refers to Figure 3-9.
In the series water treatment system (Second grade Na+ Exchanger or RO
pre-treatment system), it ensures only one valve in regeneration or washing
status and there is water in service.

A) The interlock cable connector need to be connected with the same color
of the interlock connector on the main board.
B) The above figure of interlock cable connection takes three valves
interlocking as an example.

32
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Use interlock cable to connect the black socket of one valve with the blue
socket of another valve in series.
One system with several valves, if interlock cable is disconnected, the
system is divided into two individual system.

C. Double (Multiple) Valves, Supply Water Simultaneously

and Regenerate Separately

It only needs to connect the two or more valves by interlock cables. The
wiring refers to Figure3-10.

3.3 System Configuration and Flow Rate Curve


A.Product Configuration
Commonly used tank size and filter material volume configuration for
filter system
Tank Size Volume of Carbon Filter Sand Filter

33
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Filter Filtering Backwash Filtering Backwash


Material Flow Rate Flow Rate Flow Rate Flow Rate
mm L m3/h m3/h m3/h m3/h
φ180×1130 16 0.3 0.9 0.6 1.3
φ205×1300 25 0.4 1.1 0.8 1.7
φ255×1390 40 0.6 1.7 1.2 2.6
φ300×1390 60 0.8 2.5 1.7 3.8
φ355×1670 100 1.2 3.4 2.4 5.2
φ400×1670 120 1.5 4.5 3.1 6.8
Attention: the filtering flow rate of carbon filter is calculated based on the
12m/h operation rate; the backwash flow rate is calculated based on the
10L/(m2*s) backwash intensity; the filtering flow rate of sand filter is
calculated based on the 25m/h operation rate; the backwash flow rate is
calculated based on the 15L/(m2*s) backwash intensity.

Commonly used tank size, resin volume, brine tank and and injector
configuration for softener system

F116Q, F117Q:

Resin Flow Brine Tank The Minimum Salt Control


Tank Size Injector
Volume Rate Size Consumption for Valve
(mm)
(L) (t/h) (mm) Regeneration(Kg) Model Model
φ180×1130 16 0.5 φ250×520 2.40
6303
φ205×1300 25 0.7 φ390×810 4.00
φ255×1390 40 1.2 φ390×810 6.00 6304 F117Q
φ300×1650 60 1.8 φ450×940 9.00
6307
φ355×1650 100 2.5 φ500×1060 15.00
φ255×1390 40 1.2 φ390×810 6.00
6306
φ300×1650 60 1.8 φ450×940 9.00
φ355×1650 100 2.5 φ500×1060 15.00 6308 F116Q
φ400×1650 120 3.5 φ550×1160 18.00
6309
φ450×1650 150 4.5 φ550×1160 22.50
F68Q, F69Q:

34
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Resin Flow Brine Tank The Minimum Salt Control


Tank Size Injector
Volume Rate Size Consumption for Valve
(mm)
(L) (t/h) (mm) Regeneration(Kg) Model Model
φ205×1300 25 0.7 φ390×810 4.00 6301
φ255×1390 40 1.2 φ390×810 6.00 6303 F69Q
φ300×1650 60 1.8 φ450×940 9.00 6304
φ355×1650 100 2.5 φ500×1060 15.00 6306
φ400×1650 120 3.5 φ550×1160 18.00 6307 F68Q
φ450×1650 150 4.5 φ550×1160 22.50 6308

Attention: The flow rate calculation is based on linear velocity


25m/h; the minimum salt consumption for regeneration calculation
is based on salt consumption 150g/L (Resin).

35
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

B. Flow Rate Characteristic


1) Pressure-flow rate curve

36
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

37
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

38
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

2) Injector parameter table


F68Q, F69Q:

Inlet Draw Rate(L/M)


Pressure F69Q F68Q
6301 6303 6304 6306 6307 6308
MPa
Coffee Yellow Blue Black Purple Red

0.15 1.47 2.30 2.80 4.03 4.74 5.24


0.20 1.51 2.60 3.30 4.67 5.46 5.99
0.25 1.59 2.92 3.71 5.07 6.11 6.69
0.30 1.76 3.20 4.08 5.59 6.60 7.32
0.35 1.88 3.45 4.33 6.06 7.03 7.79
0.40 2.00 3.70 4.67 6.44 7.40 8.11

F116Q, F117Q:

Inlet Draw Rate(L/M)


Pressure F117Q F116Q
6303 6304 6307 6306 6308 6309
MPa
Yellow Blue Purple Black Red Green

0.15 1.95 2.37 3.08 3.73 4.78 5.77


0.20 2.28 2.70 3.52 4.27 5.58 6.68
0.25 2.52 3.02 3.88 4.78 6.28 7.37
0.30 2.75 3.33 4.27 5.27 6.80 8.10
0.35 2.95 3.55 4.63 5.67 7.37 9.70
0.40 3.15 3.75 4.92 6.07 7.65 9.18

39
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
3) Configuration for Standard Injector and Drain Line Flow Control
F68Q, F69Q:
Draw Slow Backwash/
Tank Control
Injector Injector Rate Rinse Fast Rinse
Dia. BLFC Optional DLFC Valve
Mode Color
mm L/m L/m L/m Model

8468076, 8468075, 8468057, 8468056, 846804


205 6301 Coffee 1.76 0.92 7.50
8468052 (Standard). 2
8468076, 8468075, 8468057, 8468056, 846806
255 6303 Yellow 3.20 2.01 12.17 F69Q
8468052, 8468053 (Standard). 1
8468076, 8468075, 8468057, 8468056, 846807
300 6304 Blue 4.08 2.66 17.17
8468052, 8468053 (Standard). 7
8468076, 8468075, 8468057, 8468056,
846806
355 6306 Black 5.59 3.33 8468052, 8468053, 8468054, 8468055 24.83
2
(Standard).
8468076, 8468075, 8468057, 8468056,
No
400 6307 Purple 6.60 4.05 8468052, 8468053, 8468054, 8468055 33.17 F68Q
DLFC
(Standard).
8468076, 8468075, 8468057, 8468056,
No
450 6308 Red 7.32 4.42 8468052, 8468053, 8468054, 8468055 33.17
DLFC
(Standard).

40
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

F116Q,F117Q:
Tank Draw Slow Backwash/FastControl
Injector Injector
Dia. Rate Rinse BLFC Optional DLFC Rinse Valve
Mode Color
mm L/m L/m L/m Mode

175~ 8468076, 8468075, 8468057, 8468056,


6303 Yellow 2.75 1.66 8468042 7.33
205 8468052, 8468053 (Standard).
225~ 8468076, 8468075, 8468057, 8468056,
6304 Blue 3.33 2.18 8468060 8.83
255 8468052, 8468053 (Standard). F117Q
8468076, 8468075, 8468057, 8468056,
300~
6307 Purple 4.27 3.03 8468052, 8468053, 8468054, 8468055 8468062 16.83
355
(Standard).
255~ 8468076, 8468075, 8468057, 8468056,
6306 Black 5.27 3.31 8468077 19
300 8468052, 8468053, 8468054 (Standard).
8468076, 8468075, 8468057, 8468056,
325~
6308 Red 6.80 4.28 8468052, 8468053, 8468054, 8468055 8468062 24.83
355 F116Q
(Standard).
8468076, 8468075, 8468057, 8468056,
400~
6309 Green 8.10 5.23 8468052, 8468053, 8468054, 8468055 No DLFC 31.33
450
(Standard).

Remark: Above data for the product configurations and relevant


characteristics are only for reference. When put in practice, please subject
to the different requirements of raw water hardness and application.

4) Configuration for Brine Line Flow Control


F68Q, F69Q:
No. 8468076 8468075 8468057 8468056 8468052 8468053 8468054 8468055
Flow
rate 0.31 0.70 1.03 1.52 2.06 3.25 5.41 6.67
L/m

F116Q, F117Q:
No. 8468076 8468075 8468057 8468056 8468052 8468053 8468054 8468055
Flow
rate 0.30 0.58 0.68 1.32 1.55 2.95 5.00 5.67
L/m

41
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

42
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

3.4 Parameter settlement


① Service Time T1
Water Treatment Capacity:
Q=VR×K÷YD (m3)
Hardness of Inlet Water, mmol/L.
Exchange factor, mmol/L, 400~1000.
Down-flow regeneration, take 400~
750; Up-flow regeneration, take
450 ~ 1000. If the inlet water
hardness is higher, the factor is
smaller.

Resin volume, m3.


By hours:T1=Q÷Qh (Hour)
Average water consumption per hour (m3/h)
Water treatment capacity (m3)
By days: T1=Q÷Qd (Day)
Average water consumption per day (m3/d)
Water treatment capacity (m3)
② Backwash Time T2
Generally, it is suggested to set 10~15 minutes. The higher the
turbidity is, the longer backwash time shall be set. However, if the
turbidity is more than 5FTU, it is better to install a filter in front of the
exchanger.
③ Brine & Slow Rinse Time T3
T3=(40~50)×HR(min)
Generally, T3=45HR(min)
In this formula,HR——The hight of the resin in the exchange tank (m)
④ Brine Tank Refill Time T4
Down flow regeneration:T4=0.45×VR÷Brine refill speed
Up flow regeneration:T4=0.34×VR÷Brine refill speed
43
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

In this formula,VR——Resin volume (m3)


The brine tank brine refill speed is related to the inlet pressure. The real
refill time should be 1 to 2 minutes longer than the calculated time in
order to refill enough water in the brine tank. (The brine tank should be
equipped with liquid level controller)
⑤ Fast Rinse Time T5
T5=12×HR(min)
Generally, the water for fast rinse is 3~6 times of resin volume, and
fast rinse time can be ranged from 10~16 minutes. But it should meet the
requirements of qualified outlet water.
⑥ Exchange Factor
Exchange factor = E/(k×1000)
In this formula, E——Resin working exchange capability (mol/m3), it is
related to the quality of resin. Down-flow
regeneration, take 800 ~ 900. Up-flow
regeneration, take 900~1200.
K——Security factor, always take 1.2~2. It is related
to the hardness of inlet water: the higher the
hardness is, the bigger the K is.
⑦ Set Interval Backwash Times (Only for F68Q/F69Q)
When the turbidity of raw water is higher, the interval backwash time
could be set F-00. That is to say, backwash in each regeneration; when
the turbidity is lower, the interval backwash time could be set F-01 (or
other number value), it is to say that backwash in every two regeneration.
Thus, Service → Brine & Slow rinse → Brine refill → Fast rinse →
Service → Backwash → Brine & Slow rinse → Brine refill → Fast rinse.
⑧ Regeneration Time: The whole cycle for regeneration is about two
hours. Please try to set up the regeneration time when you don’t need to
use water according to the actual situation.
The above calculation of parameters for each step is only for
reference, the actual proper time will be determined after adjusting by
water exchanger supplier. This calculation procedure of softener is only
for industrial application; it is not suitable for small softener in residential

44
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

application.

3.5 Parameter Enquiry and Setting


A. Parameter Enquiry
When the fourth decimal point of the digital tube turning on, press
and hold both and for 5 seconds to unlock the button; then press
until the third decimal point of digital tube turned on, enter to
program inquiry mode. Press or to view each value according
to the following process. (Press to exit.)

45
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

B. Parameter Setting
In program inquiry mode, press and enter into program set
mode. Press or can adjust the value.

46
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

C. The steps of parameter setting (Take F117Q3 A-01 for


Example)
Item Process steps Symbol
1. In time of day viewing status, Press to enter
program set mode, both hour value and “:” flash, press
Time of or to adjust the hour value;
Day 2. Press again, both minute value and “:” flash, press
or to adjust the minute value;
3. Press to finish adjustment, press to return.
1. In regeneration time viewing status, press and
enter into program set mode. Regeneration hour value
Regen flashes, press or to adjust the hour value (“:”
eration lights on);
Time 2. Press again, regeneration minute flashes, press
or to adjust the minute value (“:” lights on);
3. Press to finish adjustment, press to return.
1. In control mode viewing status, press to enter
Control program set mode. Control mode A-01 flashes, press
Mode or to adjust the working mode;
2. Press to finish adjustment, press to return.
1. In water treatment capacity viewing status, press
Water
and enter program set mode. Water treatment capacity
Treatm
value flashes, press or to adjust the valve;
ent
2. Press again, water treatment capacity decimal
Capacit
flashes, press or to adjust the decimal value;
y
3, Press to finish adjustment, press to return.
1. In backwash viewing status, press and enter
Backw
program set mode. Backwash time value flashes, press
ash
or to adjust the backwash time;
Time
2. Press to finish adjustment, press to return.

47
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

1. In brine & slow rinse time viewing status, press and


Brine &
enter program set mode. Brine & slow rinse time value
Slow
flashes, press or to adjust the brine & slow rinse
Rinse
time;
Time
2. Press to finish adjustment, press to return.
1. In fast rinse time viewing status, press and enter
Fast
program set mode. Fast rinse time value flashes, press
Rinse
or to adjust the fast rinse time;
Time
2. Press , finish adjustment, press to return.
1. In brine refill time viewing status, press and enter
Brine
program set mode. Brine refill time value flashes, press
Refill
or to adjust the brine refill time;
Time
2. Press to finish adjustment, press to return.
Maxim
1. In maximum interval regeneration days viewing status,
um
press and enter program set mode. Maximum interval
Interval
regeneration days value flashes, press or to
Regen
adjust the maximum interval regeneration days;
eration
2. Press to finish adjustment, press to return.
Days
1. In signal output mode viewing status, press and
Signal enter program set mode. Signal output mode value
Output flashes, press or to adjust the signal output
Mode mode;
2. Press to finish adjustment, press to return.

For example,a softener has set fast rinse time as 12 minutes. After
regenerating, the chloridion in the outlet water is always higher than
normal, which indicates that the fast rinse is too short. If you want to set
the time as 15 minutes, the modification steps as follows:
① Press and hold both and to unlock the button (The
fourth decimal point of digital tube lights off);
② Press ,the third decimal point of digital tube lights on;

48
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

③ Press or continuously until in service status, the digital


display area shows:4-12M;
④ Press , 12 flashes;
⑤ Press continuously until 12 change to 15;
⑥ Press again and hear a sound “Di” , the frame stop
flickering,the program returns to enquiry status.;
⑦ If you want to adjust other parameters, you can adjust as above
3-5 steps; if not, press to exit the program inquiry status. The display
are shows the current working status.

49
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

3.6 Trial Running


After installing the multi-functional flow control valve on the resin
tank with the connected pipes, as well as setting up the relevant
parameters, please conduct the trail running as follows:
A. Close inlet/outlet valve B and Valve C, open bypass valve A, clean the
impurity in the pipe, and then close bypass valve A (as Figure 1-3).
B. Add calculated-volume water to the brine tank and adjust the air check
valve. Add solid particle salt to the brine tank then dissolve the salt as
much as possible.
C. Power on. Press and enter Backwash status, 2-lights on, slowly
open the inlet valve B to 1/4 position, making the water flows into the
resin tank; you can hear the sound of air-out from the drain pipeline.
After air totally emptied, then open inlet valve B completely and clean the
impurity in the resin tank until the outlet water is clean. It will take 8~10
minutes to finish the whole process.
D. Press , finish the Backwash status and control valve enter into Brine
& Slow Rinse. 3-lights on, enter into the process of Brine & Slow Rinse.
The air check valve closed when control valve finished brine drawing,
then slow rinse starts to work. It is about 60~65 minutes for whole
process.
E. Press , finish Brine & Slow Rinse, and control valve turns to Fast
Rinse. 4-lights on, and start to fast rinse. After 10~15 minutes, take
some outlet water for testing: If the water hardness reaches the
requirement, and the content of chloridion in outlet water is almost the
same as the inlet water, then the valve can go to next step: Brine Refill.
F. Press , finish Fast Rinse, and control valve turns to Brine Refill,
5-lights on, the brine tank is being refilled with water to the required level.
It takes about 5~6 minutes, then add solid salt to the brine tank.
G. Press , finish Brine Refill, and control valve turn the status to
Service status and start running.

Note:
 When the control valve enters into the regeneration status, all
programs can be finished automatically according to the setting
time; if you want one of steps to be terminated early, you can press
.
 If water inflows too fast, the media in tank will be damaged. When
water inflows slowly, there is a sound of air emptying from drain
pipeline.
 After changing resin, please empty air in the resin according to
above step C.
 In the process of trial running, please check the water situation in
50
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
all positions, and ensure there is no resin leakage.
 The time of Backwash, Brine & Slow Rinse, Fast Rinse and Brine
Refill status can be set and executed according to the calculation in
the formula or suggested from the control valve suppliers.

51
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

3.7 Trouble-Shooting

A. Control Valve Fault

Problem Cause Correction


A. Electrical service to unit A. Assure permanent electrical
has been interrupted. service (Check fuse, plug, pull
1. Softener
B. Regeneration cycles set chain or switch).
fails to incorrect. B. Reset regeneration cycles.
regenerate. C. Controller is defective. C. Replace controller.
D. Motor fails to work. D. Replace motor.
2. A. Time of Day does not set A. Check program and reset time
Regeneration correctly. of day.
time is not B. Power failure more than B. Reset the time of day
correct. 3 days.
A. Bypass valve is open or A. Close or repair bypass valve.
leaking. B. Make sure there is solid salt in
B. No salt in brine tank.
the brine tank.
C. Injector is plugged.
D. Insufficient water flows C. Change or clean injector.
into brine tank. D. Check brine tank refill time.
3. Softener E. O-ring on riser pipe E. Make sure riser pipe and O-ring
supply hard leaks. are not cracked.
water. F. Internal valve leaks. F. Repair or replace valve body.
G. Regeneration cycles are G. Set correct regeneration cycles
not correct or deterioration in the program.
of water quality H. Add resin to mineral tank and
H. Shortage of resin. check the reason of resin leaks.
I. Bad quality of raw water I. Reduce the inlet turbidity, clean
or turbine is blocked. or replace turbine.
A. Inlet line pressure is too
low. A. Increase inlet line pressure.
B. Brine line is blocked. B. Clean brine line.
C. Brine line is leaking. C. Check brine line.
4. Softener D. Injector is blocked or D. Clean or replace injector.
damaged. E. Repair or replace valve body.
fails to draw
E. Internal control leaks. F. Check the drain line pipe.
brine. F. Drain line is plugged. G. Select correct injector size and
G. Sizes of injector and DLFC according to user manual.
DLFC are not matched with
tank.

52
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
A. Setting the appropriate amount
5. Unit used A. Improper salt setting.
of salt for primary regeneration.
too much B. Excessive water in brine
B. See problem No.6.
salt. tank.

Control Valve Fault (Continued)


A. Overlong refilling time.
B. Remain too much water A. Reset correct refilling time.
after brine. B. Check the injector and make
sure no stuff in the brine pipe.
6. Excessive C. Foreign material in brine
C. Clean brine valve and brine line.
water in brine valve D. Stop water supplying and restart
tank or D. Not install safety brine or install safety brine valve in salt
valve but power failure tank.
overfall.
while salting.
E. Repair or replace safety brine
E. Safety brine valve
valve.
breakdown.
A. Clean the water supply pipe.
B. Clean valve and add resin
A. Iron in the water supply cleaning chemical, increase
pipe. frequency of regeneration.
7. Pressure
B. Iron mass in the softener. C. Check backwash, brine and
lost or rust in
C. Fouled resin bed. brine tank refill. Increase frequency
pipe line
D. Too much iron in the raw of regeneration and backwash
water. time.
D. Iron removal equipment is
required to install before softening.
A. Air in water system. A. Assure that well system has
8. Loss of
B. Strainer broken. proper air eliminator control.
resin through
C. Improperly sized drain B. Replace new strainer.
drain line.
line control. C. Check for proper drain rate.

9. Control A. Controller is faulty. A. Replace controller.


cycle B. Time of regeneration B. Check program setting and
continuously. steps were set to zero. reset.

A. Check and repair valve body or


10. Drain A. Internal valve leak. replace it.
flows B. Power off when in back B. Adjust valve to service position
continuously. wash or fast rinse. by manual or turn off bypass valve
and restart when electricity supply.
11. A. Water pressure is too low A. Increase water pressure to
Interrupted or or not stable. request.
irregular B. Injector is blocked or B. Clean or replace injector.

53
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
brine. faulty. C. Check and find the reason.
C. Air in resin tank. D. Clean the floccules in resin
D. Floccules in resin tank tank.
during up-flow
regeneration.
A. Foreign material in valve
which makes valve can’t be A. Clean foreign material in valve
closed completely. body.
12. Water B. Hard water mixed in B. Change valve core or sealing
valve body. ring.
flows out
C. Water pressure is too C. Reduce water pressure or use
from drain or
high which results in valve pressure release function.
brine pipe
not getting the right status. D. Add check valve or solenoid
after
D. When in backwash valve in the outlet, or liquid level
regeneration.
status, drain line is controller in the brine tank.
communicated with brine
line.

Control Valve Fault (Continue)


A. Foreign material in
injector or injector fails to
13. Salt work. A. Clean and repair injector.
water in B. Brine valve can’t be B. Repair brine valve and clean it.
outflow pipe. shut-off. C. Extend fast rinse time.
C. Time of fast rinse too
short.
A. Regenerate according to right
way.
A. Regenerate not properly.
B. Increase backwash flow rate
B. Fouled resin bed or
and time, clean or change resin.
polluted.
C. Readjust brine drawing time.
C. Salt setting is not proper.
14. Circle D. According to the test of outlet
D. Softener setting is not
capacity water, recount and reset.
proper.
decreases. E. Regenerate unit by manual
E. Raw water quality
temporary then reset regeneration
deteriorated.
cycle.
F. Turbine has already
F. Disassemble flow meter and
gotten stuck.
clean it or replace a new flow
meter.

54
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

B. Controller Fault
Problem Cause Correction
A. Replace control board.
A. Control board is faulty.
1. All indictors B. Check and replace
B. Transformer damaged.
display on front transformer.
C. Electrical service is not
panel. C. Check and adjust
stable.
electrical service.
A. Wiring of control board with A. Check and replace
transformer fails to work. wiring.
2. No display on
B. Control board damaged. B. Replace control board.
front panel. C. Transformer damaged. C. Replace transformer.
D. Electrical service is off. D. Check electricity.
A. Wiring of locating board with
A. Replace wiring.
control board fails to work.
B. Replace locating board.
B. Locating board damaged.
C. Replace motor gear and
C. Motor gear and big gear
big gear.
damaged.
3. Show E1 D. Replace control board.
D. Control board damaged.
E. Replace wiring.
E. Wiring of motor with control
F. Replace motor.
board is fault.
G. Reset power
F. Motor damaged.
G. Set wrong model.
4. Show E3 or
A. Control board is faulty. A. Replace control board.
E4

3.8 Assembly & Parts


Flow Meter Connector & Animated Connector

55
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

5447018 Flow Meter 5457002 Animated Connector

5447018 Flow Meter 5457002 Animated Connector


Item Quan Item Qua
Description Part No. Description Part No.
No. tity No. ntity
1 Animated Nut 8945001 1 1 Animated Nut 8945001 1
2 O-ring 8378081 1 2 O-ring 8378081 1
Impeller
3 5115022 1 3 Clip 8270004 1
supporter
4 Impeller 5436010 1 4 Connector 8458038 1
Impeller
5 5115021 1
supporter
6 Clip 8270004 1
7 Shell 8002001 1

56
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

5447020 Flow Meter 5457003 Animated Connector

5447020 Flow Meter 5457003 Animated Connector


Item Quan Item Qua
Description Part No. Description Part No.
No. tity No. ntity
1 Connector 8458014 1 1 Connector 8458014 1
2 O-ring 8378064 1 2 O-ring 8378064 1
Impeller
3 5115023 1 3 Clip 8270005 1
supporter
4 Impeller 5436013 1 4 Connector 8458039 1
Impeller
5 5115024 1
supporter
6 Clip 8270005 1
7 Shell 8002006 1

57
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Construction figure of F67Q3:

58
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

F67Q3 Valve Body Components and No.[F67Q1 doesn't have No.17, 30 and 31,
and change No. 10 from 8865174 (630) to 8865175 (631)]
Ite Qu Qu
Item
m Description Part No. anti Description Part No. anti
No.
No. ty ty
638601
1 O-ring 73×5.3 8378143 1 17 Probe Wire 1
4
Screw, Cross 890901
2 O-ring 25.8×2.65 8378078 1 18 1
ST3.9×13 3
Valve Body
8022039
(ABS+GF10) 824103
3 1 19 Gear 1
Valve Body 4
8022040
(PPO+GF20)
Screw, Cross 890900
4 Seal Ring 8371001 4 20 2
ST2.9×16 8
638003
5 Motor 6158021 1 21 Locating Board 1
2
Screw, Cross 809200
6 8909016 4 22 Fitting Nut 1
ST3.9×16 4
837812
7 Small Gear 8241003 1 23 O-ring 73×3.55 2
8
837818
8 Pin 8993003 1 24 O-ring 38.7×3.55 2
4
Anti-friction 821600
9 Wire for Power 5513001 1 25 1
Washer 4
825800
10 Label 8865175(631) 1 26 Shaft 1
4
845901
11 Front Cover 8300060 1 27 Moving Disk 1
4
Wire for Locating 846901
12 5511021 1 28 Fixed Disk 1
Board 3
837002
13 Cable Clip 8126004 2 29 Seal Ring 1
7
845820
14 Control Board 6382159 1 30 Connector 1
5
Screw, Cross 544701
15 8909004 2 31 Flow Meter 1
ST2.2×6.5 8
16 Dust Cover 8005091 1

59
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Construction figure of F68Q3:

60
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

F68Q3 Valve Body Components and No.[F68Q1 doesn't have No.16, 30 and
31, and change No. 9 from 8865174 (630) to 8865175 (631)]
Ite Qu Ite Qu
m Description Part No. anti m Description Part No. anti
No. ty No. ty
1 O-ring 73×5.3 8378143 1 27 Moving Disk 8459078 1
2 O-ring 25.8×2.65 8378078 1 28 Fixed Disk 8469079 1
Valve Body
5022022
(ABS+GF10)
3 1 29 Seal Ring 8370111 1
Valve Body
5022023
(PPO+GF20)
Animated
4 Motor 6158011 1 30 5457002 1
Connector
Screw, Cross
5 8909016 4 31 Flow Meter 5447018 1
ST3.9×16
6 Small Gear 8241003 1 32 Seal Ring 8371001 2
7 Pin 8993003 1 33 Plug 8323002 1
8 Wire for Power 5513001 1 34 Seal Ring 8370003 1
8865175
9 Label 1 35 BLFC 8468055 1
(631)
10 Front Cover 8300060 1 36 O-ring 11×2 8378169 1
Wire for Locating
11 5511021 1 37 Connector 8458068 1
Board
12 Cable Clip 8126004 2 38 Tube 8457004 1
13 Control Board 6382159 1 39 Hex Nut 8940001 1
Screw, Cross
14 8909004 2 40 Animated Nut 8945025 1
ST2.2×6.5
15 Dust Cover 8005091 1 41 Connector 8458064 1
16 Probe Wire 6386014 1 42 O-ring 15×1.8 8378179 1
Screw, Cross Without this
17 8909013 1 43 DLFC 1
ST3.9×13 part
18 Gear 8241053 1 44 Clip 8270010 1
Screw, Cross Screw, Cross
19 8909008 2 45 8902017 2
ST2.9×16 M5×35
20 Locating Board 6380032 1 46 Cover of Injector 8315001 1
21 Fitting Nut 8092004 1 47 O-ring 30×1.8 8378025 1
22 O-ring 73×3.55 8378128 2 48 Nozzle, Injector 8454008 1
23 O-ring 38.7×3.55 8378184 2 49 Throat, Injector 8467008 1
24 Anti-friction Washer 8216004 1 50 Injector Body 8008010 1
O-ring
25 Shaft 8258004 1 51 8378012 1
10.82×1.78

61
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

26 Moving Seal Ring 8370001 1 52 O-ring 7.5×1.8 8378016 2

62
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Construction figure of F69Q3:

63
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

F69Q3 Valve Body Components and No.[F69Q1 doesn't have No.18, 31 and
32, and change No. 10 from 8865176 (632) to 8865177 (633)]
Ite Qu
Item Qua
m Description Part No. anti Description Part No.
No. ntity
No. ty
837814 837005
1 O-ring 73×5.3 1 27 Moving Seal Ring 1
3 3
837807 845901
2 O-ring 25.8×2.65 1 28 Moving Disk 1
8 6
Valve Body 502202
(ABS+GF10) 4 846901
3 1 29 Fixed Disk 1
Valve Body 502202 5
(PPO+GF20) 5
837101 837003
4 Seal Ring 3 30 Seal Ring 1
9 4
832300 545700
5 Plug 1 31 Animated Connector 1
5 3
615800 544702
6 Motor 1 32 Flow Meter 1
6 0
Screw, Cross 890901 832300
7 4 33 Plug 1
ST3.9×16 6 2
824101 837000
8 Small Gear 1 34 Seal Ring 1
0 3
899300 846805
9 Pin 1 35 BLFC 1
3 3
886517 837816
10 Label 1 36 O-ring 11×2 1
7(633) 9
830005 845806
11 Front Cover 1 37 Connector 1
9 8
Wire for Locating 551102 845700
12 1 38 Tube 1
Board 1 4
638215 894000
13 Control Board 1 39 Hex Nut 1
9 1
Screw, Cross 890900 894502
14 2 40 Animated Nut 1
ST2.2×6.5 4 5
800500 845806
15 Dust Cover 1 41 Connector 1
5 4
812600 837817
16 Cable Clip 2 42 O-ring 15×1.8 1
4 9
551300 846807
17 Wire for Power 1 43 DLFC 1
1 7
638601 827001
18 Probe Wire 1 44 Clip 1
4 0
Screw, Cross 890901 Screw, Cross 890201
19 1 45 2
ST3.9×13 3 M5×35 7
824105 831500
20 Gear 1 46 Cover of Injector 1
3 1
21 Screw, Cross 890900 5 47 O-ring 30×1.8 837802 1
64
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
ST2.9×16 8 5
638003 845400
22 Locating Board 1 48 Nozzle, Injector 1
3 4
809200 846700
23 Fitting Nut 1 49 Throat, Injector 1
7 4
837810 800801
24 O-ring 50.39×3.53 1 50 Injector Body 1
7 0
Anti-friction 821601 837801
25 1 51 O-ring 10.82×1.78 1
Washer 0 2
825800 837801
26 Shaft 1 52 O-ring 7.5×1.8 2
9 6

65
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Construction figure of F71Q3:

66
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

F71Q3 Valve Body Components and No.[F71Q1 doesn't have No.16, 28 and 29,
and change No. 8 from 8865176 (632) to 8865177 (633)]
Ite Qu
Item Qua
m Description Part No. anti Description Part No.
No. ntity
No. ty
1 O-ring 73×5.3 8378143 1 16 Probe Wire 6386014 1
Screw, Cross
2 O-ring 25.8×2.65 8378078 1 17 8909013 1
ST3.9×13
Valve Body
8022048
(ABS+GF10)
3 1 18 Gear 8241038 1
Valve Body
8022049
(PPO+GF20)
Screw, Cross
4 Motor 6158006 1 19 8909008 5
ST2.9×9.5
Screw, Cross
5 8909016 4 20 Locating Board 6380033 1
ST3.9×16
6 Small Gear 8241010 1 21 Fitting Nut 8092007 1
O-ring
7 Pin 8993003 1 22 8378107 1
50.39×3.53
8865177 Anti-friction
8 Label 1 23 8216010 1
(633) Washer
9 Front Cover 8300059 1 24 Shaft 8258009 1
Wire for Locating
10 5511021 1 25 Moving Disk 8459019 1
Board
11 Control Board 6382159 1 26 Fixed Disk 8469018 1
Screw, Cross
12 8909004 2 27 Seal Ring 8370038 1
ST2.2×6.5
13 Dust Cover 8005005 1 28 Connector 8458206 1
14 Cable Clip 8126004 2 29 Flow Meter 5447020 1
15 Wire for Power 5513001 1

67
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Construction figure of F116Q3:

68
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

F116Q3 Valve Body Components and No.[F116Q3 doesn't have No.16, 30 and
31, and change No. 9 from 8865174 (630) to 8865175 (631)]

Ite Qu Ite
Qua
m Description Part No. anti m Description Part No.
ntity
No. ty No.

1 O-ring 73×5.3 8378143 1 27 Moving Disk 8459078 1


2 O-ring 25.8×2.65 8378078 1 28 Fixed Disk 8469079 1
Valve Body
5022104
(ABS+GF10)
3 1 29 Seal Ring 8370111 1
Valve Body
5022105
(PPO+GF20)
Animated
4 Motor 6158073 1 30 5457002 1
Connector
Screw, Cross
5 8909016 4 31 Flow Meter 5447018 1
ST3.9×16
6 Small Gear 8241003 1 32 Seal Ring 8371001 2
7 Pin 8993003 1 33 Plug 8323002 1
8 Wire for Power 5513001 1 34 Seal Ring 8370003 1
8865175
9 Label 1 35 BLFC 8468055 1
(631)
10 Front Cover 8300060 1 36 O-ring 11×2 8378169 1
Wire for Locating
11 5511021 1 37 Connector 8458068 1
Board
12 Cable Clip 8126004 2 38 Tube 8457004 1
13 Control Board 6382159 1 39 Hex Nut 8940001 1
Screw, Cross
14 8909004 2 40 Animated Nut 8945025 1
ST2.2×6.5
15 Dust Cover 8005091 1 41 Connector 8458064 1
16 Probe Wire 6386014 1 42 O-ring 15×1.8 8378179 1
Screw, Cross Without this
17 8909013 1 43 DLFC 1
ST3.9×13 part
18 Gear 8241053 1 44 Clip 8270010 1
Screw, Cross Screw, Cross
19 8909008 2 45 8902017 2
ST2.9×16 M5×35
20 Locating Board 6380032 1 46 Cover of Injector 8315001 1
21 Fitting Nut 8092004 1 47 O-ring 30×1.8 8378025 1
22 O-ring 73×3.55 8378128 2 48 Nozzle, Injector 8454009 1
23 O-ring 38.7×3.55 8378184 2 49 Throat, Injector 8467009 1
24 Anti-friction Washer 8216004 1 50 Injector Body 8008010 1
O-ring
25 Shaft 8258004 1 51 8378012 1
10.82×1.78

69
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

26 Moving Seal Ring 8370001 1 52 O-ring 7.5×1.8 8378016 2

70
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

Construction figure of F117Q3:

71
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

F117Q3 Valve Body Components and No.[F117Q1 doesn't have No.18, 31


and 32, and change No. 10 from 8865176 (632) to 8865177 (633)]
Ite Qu
Item Qua
m Description Part No. anti Description Part No.
No. ntity
No. ty
837814 837005
1 O-ring 73×5.3 1 27 Moving Seal Ring 1
3 3
837807 845907
2 O-ring 25.8×2.65 1 28 Moving Disk 1
8 9
Valve Body 502210
(ABS+GF10) 6 Fixed Disk 846908
3 1 29 1
Valve Body 502210 Seal Ring 0
(PPO+GF20) 7
837101 837011
4 Seal Ring 3 30 Seal Ring 1
9 2
832300 545700
5 Plug 1 31 Animated Connector 1
5 3
615800 544702
6 Motor 1 32 Flow Meter 1
6 0
Screw, Cross 890901 832300
7 4 33 Plug 1
ST3.9×16 6 2
824101 837000
8 Small Gear 1 34 Seal Ring 1
0 3
899300 846805
9 Pin 1 35 BLFC 1
3 5
886517 837816
10 Label 1 36 O-ring 11×2 1
7(633) 9
830005 845806
11 Front Cover 1 37 Connector 1
9 8
Wire for Locating 551102 845700
12 1 38 Tube 1
Board 1 4
638215 894000
13 Control Board 1 39 Hex Nut 1
9 1
Screw, Cross 890900 894502
14 2 40 Animated Nut 1
ST2.2×6.5 4 5
800500 845806
15 Dust Cover 1 41 Connector 1
5 4
812600 837817
16 Cable Clip 2 42 O-ring 15×1.8 1
4 9
551300 846806
17 Wire for Power 1 43 DLFC 1
1 2
638601 827001
18 Probe Wire 1 44 Clip 1
4 0
Screw, Cross 890901 Screw, Cross 890201
19 1 45 2
ST3.9×13 3 M5×35 7
824105 831500
20 Gear 1 46 Cover of Injector 1
3 1
21 Screw, Cross 890900 5 47 O-ring 30×1.8 837802 1
72
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
ST2.9×9.5 8 5
638003 845400
22 Locating Board 1 48 Nozzle, Injector 1
3 7
809200 846700
23 Fitting Nut 1 49 Throat, Injector 1
7 7
837810 800801
24 O-ring 50.39×3.53 1 50 Injector Body 1
7 0
Anti-friction 821601 837801
25 1 51 O-ring 10.82×1.78 1
Washer 0 2
825800 837801
26 Shaft 1 52 O-ring 7.5×1.8 2
9 6

73
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

4. Warranty Card
Dear client:
This warranty card is the guarantee proof of Runxin brand
multi-functional flow control valve. It is kept by client self. You could get
the after-sales services from the supplier which is appointed by Runxin
manufacturer. Please keep it properly. It couldn’t be retrieved if lost. It
couldn’t be repaired free of charge under the below conditions:
1. Guarantee period expired. (One year)
2. Damage resulting from using, maintenance, and keeping that are not
in accordance with the instruction.
3. Damage resulting from repairing not by the appointed maintenance
personnel.
4. Content in guarantee proof is unconfirmed with the label on the real
good or be altered.
5. Damage resulting from force majeure.
Product Multi-functional Flow Control Valve
Name for Water Treatment Systems
Code of
Model
Valve Body
Purchase
Company Tel/Cel.
Name

Problem

Solution

Maintenance
Date of Date of
Man
Repairing Examination
Signature
When product needs warranty service, please contact with your
direct supplier first, after got permission, then fill in the below content and

74
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

send this card together with the product to the appointed suppliers or
Runxin company.
End-user
Company Tel/Cel.
Name
Purchase
Company Tel/Cel.
Name
Model Code of Valve Body
Resin Tank Size Raw Water Hardness
Tank Size φ ×
L mmol/L
Water Source:
Water Treatment Backwash Time
Ground-water □ Tap
Capacity m3 min
Water □
Brine & Slow Rinse Time Brine Refill Time Fast Rinse Time
min min min

Problem
Description

WENZHOU RUNXIN MANUFACTURING MACHINE CO., LTD.


ADD.: NO.169, RUNXIN ROAD, SHANFU TOWN, WENZHOU,
ZHEJIANG, CHINA.
TEL.:0086-577-88630038, 88576512, 85956057
FAX:0086-577-88633258
E-MAIL: [email protected] http://www.run-xin.com

Rev.A.1902

75
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q

76

You might also like