Runxin ManuL F71Q1 55504
Runxin ManuL F71Q1 55504
:
WO 2006/007772
China Patent No.: ZL201520680239.8
US Patent No.: 7549446
India Patent No.: 232582
Russia Patent No.:2349819
South Korea Patent No.:10-0914137
Mexico Patent No.: 268581
Australia Patent No.: 2005263257
Philippine Patent No.: 1-2006-502553
Taiwan Patent No.:M287896
User Manual
Please read this manual in details before using the valve and
keep it properly in order to consult in the future.
0WRX.466.212
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Before the valve put into use, please fill in the below content for
future reference.
When all symbols light on, press and hold and buttons for 5
seconds to enter the menu of valve model selection. Please set the
program type in accordance with the product type. (Time clock type
by days or meter type, for example,F67Q1 should be set as 67Q1;
F67Q3 should be set as 67Q3 etc., it should not be set to other type.)
Parameter Setting
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Factory Actual
Parameter Unit
Default Value
Control Mode A-01/02 (Q3 meter
/ A-01
type available)
Unit Mode HU-1/2 (Q3 meter type
/ HU-1
available)
Water Treatment Capacity (Q3
m3 10
meter type available)
Service Days (Time type by day) D. 03
Regeneration Time / 02:00
Backwash Interval Times
/ F-00
(F68Q/F69Q available)
Rinsing Frequence (F67Q/F71Q
/ F-00
available)
Backwash Time min. 10
Brine & Slow Rinse Time
min. 60
(F67Q/F71Q unavailable)
Brine Refill Time
min. 05
(F67Q/F71Q unavailable)
Fast Rinse Time min. 10
Interval Regeneration Days
D 30
(Q3 meter type available)
Output Mode b-01(02) / b-01
If there is no special requirement when product purchase, F68Q is
without the drain line flow control,and choose 8# injector as the
standard configuration. We choose 8468077 drain line flow control,
and 4# injector for F69Q as standard configuration. F116Q is without
the drain line flow control,and choose 9# injector as the standard
configuration. We choose 8468062 drain line flow control,and 7#
injector for F69Q as standard configuration.
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Catalogue
Notice ................................................................................................................... 1
1. Product Overview........................................................................................... 3
1.1. Main Application & Applicability .......................................................... 3
1.2. Product Characteristics........................................................................... 3
1.3. Service Conditions ................................................................................. 6
1.4. Product Structure and Technical Parameters .......................................... 7
1.5. Installation ............................................................................................ 12
2. Basic Setting & Usage ................................................................................ 16
2.1. The Function of PC Board ................................................................... 16
2.2. Basic Setting & Usage(F116Q3 A-01 as example) .......................... 20
I
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Notice
To ensure normal operation of the valve, please consult with
professional installation or maintenance personnel before using it.
If there is any pipeline engineering and electric works, it must be
finished by professional at the time of installation.
Do not use the control valve with the unsafe or the quality-unknown
water.
Depending on the changing of working environment and water
requirement, each parameter of softener should be adjusted accordingly.
When the water treatment capacity is too low, please check the resin. If
the reason is shortage of resin, please add; if the resin turns to reddish
brown or broken, please replace.
Test water quality periodically to verify that system is performing
satisfactorily.
Sodium used in the water softening process should be considered as
part of your overall dietary salt intake. Contact your doctor if you are on a
low sodium diet.
When this valve is used for softening, please ensure the solid salt is
available in the brine tank all the time during use. The brine tank should
be added by the clean water softening salts only, at least 99.5% pure,
forbidding use the small salt.
Do not put the valve near the heat resource, high humidity, corrosive,
intense magnetic field or intense librations environment. And do not
leave it outside.
Forbidden to pull the injector body. Avoid to use injector body as
support to carry the system.
Forbidden to use the brine tube or other connectors as support to carry
the system.
1
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
2
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
1. Product Overview
3
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
not need to reset. The process will continue to work after power on.
The valve will automatically rotate for more than ten seconds
after it is power on
After the valve power on, it will automatically rotate for more than
ten seconds to turn back to the position when the electricity is cut off.
Buttons lock
No operations to buttons on the controller within 1 minute, button
lock indicator lights on which represents buttons are locked. Before
operation, press and hold the “ ”and“ ” buttons for 5 seconds to
unlock. This function can avoid incorrect operation.
Interval backwash times (Suitable for F68Q/F69Q)
It could set up interval backwash times for F68Q/F69Q up-flow
regeneration valve, which means several times of services but one time
of backwash. The setting of interval backwash times depends on the
local water turbidity. (The lower the turbidity is, the longer of the interval
backwash times can be set)
It can choose time clock type or meter type by program
selection
When all symbols light on, press and hold and buttons for 5
seconds to enter the menu of valve model selection. Please set the
program type in accordance with the product type. (Tim clock type by
days or meter type) (Notice: The meter type product has one flow meter
and flow meter cable, but the time clock type does not).
Two meter types can be selected (Suitable for
F67Q3,F68Q3,F69Q3,F71Q3,F116Q3,F117Q3)
Model Name Instruction
Regenerate on the day although the available volume
Meter
A-01 of treated water drops to zero (0). Regeneration starts
Delayed
at the regeneration time.
Meter Regenerate immediately when the available volume of
A-02
Immediate treated water drops to zero(0).
4
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Interlock function
It has an interlock function to realize only one valve in regeneration
but the others are in service while several valves are in parallel
connection or in series connection in the system. In multi-steps
treatment systems such as RO pre-treatment, when several valves are
in series, there is only one valve in regeneration or washing to ensure
there is water passing all the times while different valves in regeneration
or washing. (Application refer to Figure 3-9)
Signal Output (F116Q as example)
There is a signal output connector on the main control board. It is for
controlling external wiring (Refer to figures from Figure3-1 to Figure
3-8).
There are two kinds of output modes: b-01 Mode: Turn on when
regeneration started and shut off at the end of regeneration; b-02 Mode:
Signal available only at intervals of regeneration cycles and in service.
In the above table, First Grade Na+ represents First Grade Na+
Exchanger. Second Grade Na+ represents Second Grade Na+
Exchanger.
When the water turbidity exceeds the conditions, a filter should be
installed on the inlet of control valve.
When the water hardness is exceeds the conditions, the outlet water
hardness will hardly reach the requirement of boiler feed water
(0.03mmol/L). It is suggested to adopt second grade softener.
6
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
7
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
8
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
9
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
B. Technical Parameters
F71Q1, F71Q3, F69Q1, F69Q3, F117Q1, F117Q3 control valves are
suitable for the power adapter output: DC12V, 1A, other models are
suitable for the power adapter output: DC12V, 1.5 A.
Connector Size
Flow Rate
Model Inlet Drain Brine Line Remark
m3/h
/Outlet Line Connector
Filter, time
F67Q1
clock type
G1 G1 / 4 (@0.3MPa)
Filter, meter
F67Q3
type
Filter, time
F71Q1
clock type
G3/4 G3/4 / 2 (@0.3MPa)
Filter, meter
F71Q3
type
Up-flow, time
F68Q1 G1 NPT3/4 G3/8 4 (@0.3MPa)
clock type
10
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Up-flow,
F68Q3
meter type
Up-flow, time
F69Q1
clock type
G3/4 NPT3/4 G3/8 2 (@0.3MPa)
Up-flow,
F69Q3
meter type
Down-flow,
F116Q1 time clock
G1 NPT3/4 G3/8 4 (@0.15MPa) type
Down-flow,
F116Q3
meter type
Down-flow,
F117Q1 time clock
G3/4 NPT3/4 G3/8 2 (@0.15MPa) type
Down-flow,
F117Q3
meter type
11
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
1.5. Installation
A. Installation notice
Before installation, read all those instructions completely. Then
obtain all materials and tools needed for installation.
The installation of product, pipes and circuits should be
accomplished by professional to ensure the product can operate
normally.
Perform installation according to relative pipeline regulations and
the specification of Water Inlet, Water Outlet, Drain Outlet, Brine Line
Connector.
B. Device location
① The filter or softener should be located close to the drain.
② Ensure the unit is installed in enough space for operating and
maintenance.
③ Brine tank needs to be close to softener.
④ The unit should be kept away from the heater, and not exposed
outdoor. Sunshine or rain will cause the system damage.
⑤ Please avoid to install the system in one acid/alkaline, Magnetic or
strong vibration circumstance, because above factors will cause the
system disorder.
⑥ Do not install the filter or softener, drain pipeline in circumstance
which temperature may drop below 5℃, or above 50℃.
⑦ The system should be installed in a place where there will be the
minimum loss in case of water leakage.
12
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
13
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Notice:
● The length of riser tube should be neither higher 2mm nor 5mm lower
than the tank top opening, and its top end should be rounded to avoid
damage of O-ring inside the valve.
● Avoid floccules substance together with resin to fill in the mineral tank.
● Avoid O-ring inside control valve falling out while rotate it on the tank.
② Install animated connector
As Figure1-2 shows, put the sealing ring into nut of animated
connector, and screw in
water inlet.
③ Install flow meter
As Figure1-2 shows,
put the seal ring into nut
of flow meter, screw in
water outlet; insert the
sensor into flow meter.
④ Pipeline connection
a. As Figure1-3 shows, install a
pressure gauge in water inlet.
b. Install valve A, B, C and D in the
intermediate pipeline, inlet and
outlet. valve D is a sampling valve.
(Or adopt F70A/F70C bypass
valve).
c. Install a check valve in water
outlet.
d. Inlet pipeline should be in parallel
with outlet pipeline. Support inlet
and outlet pipeline with fixed holder.
Note:
14
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
●If the water outlet or water tank is installed higher than control valve or
parallel interlock system with multi-outlets, a liquid level controller must
be installed in brine tank, or install a check valve in water outlet. Or else,
the water in water outlet or water tank will flow backwards into
brine tank when backwash. The water in water outlet or water tank
will flow backwards into drain when brine refill — Suitable for
F68Q/F69Q/F116Q/F117Q.
●If use a soldered copper to install inlet/outlet pipes, do all sweat
soldering before connecting pipes to the valve. Torch heat will damage
plastic parts.
●When turning threaded pipe fittings onto plastic fitting, do not use
excessive force to make threads misaligned or break valve.
●If the valve belongs to time clock type, there is no step ② and ③
⑤ Install drain pipeline
a. As the Figure 1-4 shows,
slide the drain hose connector
into drain outlet.
b. Locate the drain hose well as
the Figure 1-4 show.
Note:
●Control valve should be higher
than drain outlet, and not far from the drain hose. If drain outlet higher
than control valve, a check valve must be installed in drain outlet. Or
else, the waste water will flow backwards into water outlet when
brine refill—Suitable for F68Q / F69Q / F116Q / F117Q.
● Be sure not to connect drain with sewer, and leave a certain space
between them, avoid waste water being absorbed to the water treatment
equipment, such as showed in the Figure1-4.
⑥ Connect brine tube
a. As Figure 1-5 shows, slide 3/8″ brine tube hose connector over end of
15
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
brine tube.
b. Insert tube bushing into the end of brine tube.
c. Tighten nut onto brine line connector.
d. Connect the other end of brine tube with the brine tank. (The liquid
level controller and air-blocker should be installed in the brine tank.)
Remark: The brine tube and drain pipeline should not be bended or
plugged.
16
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
17
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
18
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Press and hold both and for 5 seconds to unlock the buttons.
In program set mode, press to return to program inquiry mode; in
program inquiry mode, press to return to menu mode.
Press while adjusting the values, then it will return to program
inquiry mode directly without saving values. Press , it will save the
values and return to program inquiry mode.
19
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
example)
A. Parameter specifications
Factory Parameter
Function Indicator Instruction
Default set range
00:00~ When use, enquiry and set,the time of
Time of Day ":"Flashes Random
23:59 day ":" flashes.
Regeneration 00:00~
":"Lighting 02:00 Regeneration time;":" lighting.
Time 23:59
Meter Delayed: Regenerate will not
start although the available volume of
A-01
treated water drops to zero (0) until at
Control the regeneration time.
/ A-01
Mode Meter Immediate : Regenerate
immediately when the available
A-02
volume of treated water drops to
zero(0).
Water
0~99.99 Water treatment capacity in one circle
Treatment m3 10.00m3
m3 (m3)
Capacity
Backwash
2- 10 0~99 Backwash time (minute)
Time
Brine &
Slow Rinse 3- 60 0~99 Brine & slow rinse time (minute)
Time
Fast Rinse
4- 10 0~99 Fast rinse time (minute)
Time
Brine Refill
5- 05 0~99 Brine refill time (minute)
Time
Maximum Regenerate at the regeneration time
H-30 30 0~40
Interval even though the available volume of
20
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Figure G Figure H
Illustration:
In Service status, the figure shows A/B/C/D. Figure C shows time of day, the
middle “:” flashes. Figure D shows regeneration time, the middle “:” turns
on;
In Backwash status, it shows as figure E/C; In Brine & Slow Rinse status, it
21
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
shows as F/C; In Fast Rinse status, it shows as figure G/C; In Brine Refill
status, it shows as figure H/C. In each status, every figure shows 15 seconds.
Above displays are taking the Meter Type F116Q3 A-01 for example. For the
Time Clock Type, it shows the rest days, such as 1-03D.
The display screen will only show “-00-” when the motor is running.
The time of day figure flashes continuously, such as “12:12” flashes, which
indicates long outage of power. It reminds to reset the time of day.
The display will show the error code, such as “-E1-” when the system is in
error.
F117Q/F116Q working process: Service → Backwash → Brine & Slow
Rinse → Fast Rinse → Brine Refill → Service.
F68Q/F69Q working process: Service → Backwash → Brine & Slow
Rinse → Brine Refill → Fast Rinse → Service.
F67Q/F71Q working process: Service → Backwash → Fast Rinse →
Service.
22
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
C. Usage
24
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
3. Applications
25
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Remark:
F68Q, F69Q working process: Service → Backwash → Brine & Slow Rinse
(Up-flow Regeneration ) → Brine Refill → Fast Rinse → Service.
F117Q, F116Q working process: Service → Backwash → Brine & Slow
Rinse (Down-flow Regeneration ) → Fast Rinse → Brine Refill → Service.
Opening the front cover of control valve, you will see the main control board
and connection parts as below:
26
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
27
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Function:
When valve in service status, if soft water tank is shortage of water,
solenoid valve will open to supply soft water, but if water tank has enough
water, solenoid valve will close, so no soft water will be supplied to the tank.
When the valve is in backwash or other regeneration status, there is no
signal output. So, solenoid valve will close, and no raw water flows into soft
water tank.
② Solenoid Valve on Inlet (Set as b-02)
Instruction: When inlet pressure exceeds 0.6MPa, install a solenoid valve on
inlet. Control mode is b-02. Pressure will be relieved when valve is switching,
the wiring refers to Figure 3-2. As Figure 3-3 shows, it also can use the
pressure relief connector to work.
28
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Function:
When inlet pressure is high, install a solenoid valve on inlet to ensure
valve switching properly. When valve is exactly in status of Service, Backwash,
Brine & Slow Rinse, Fast Rinse and Brine Refill, solenoid valve is open. When
valve is switching, solenoid valve is closed, no water flows into valve to ensure
valve switching properly. It could prevent the problem of mixing water and
water hammer.
Use interlock cable to realize valves in parallel or series connection in the
same system which is suited for RO pretreatment system or second grade Na+
system. The wiring refers to Figure 3-4:
29
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Function:
When valve is in service status, if water tank is short of water, pump starts
working. If water tank has enough water, the switch of liquid level controller
is closed, so pump does not work.
When valve is in regeneration cycle, no matter what water condition is in
water tank, open the pump to make sure there is water on inlet. As Runxin
valve no water passes outlet in regeneration cycle, it ensures no water fill into
brine tank.
A liquid switch at the top opening well or in middle water tank in RO
system protects pump from working without water in case of out of raw water.
3) Liquid Level Switch in Water Tank Controls Inlet pump (Three-phase
motor, Figure 3-6) (Set as b-01)
30
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
31
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
B. Interlock
Instruction:
In the parallel water treatment system, it ensures only one valve in
regeneration or washing status and (n-1) valves in service, that is, realizing the
function of supplying water simultaneously and regenerating individually, the
wiring refers to Figure 3-9.
In the series water treatment system (Second grade Na+ Exchanger or RO
pre-treatment system), it ensures only one valve in regeneration or washing
status and there is water in service.
A) The interlock cable connector need to be connected with the same color
of the interlock connector on the main board.
B) The above figure of interlock cable connection takes three valves
interlocking as an example.
32
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Use interlock cable to connect the black socket of one valve with the blue
socket of another valve in series.
One system with several valves, if interlock cable is disconnected, the
system is divided into two individual system.
It only needs to connect the two or more valves by interlock cables. The
wiring refers to Figure3-10.
33
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Commonly used tank size, resin volume, brine tank and and injector
configuration for softener system
F116Q, F117Q:
34
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
35
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
36
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
37
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
38
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
F116Q, F117Q:
39
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
3) Configuration for Standard Injector and Drain Line Flow Control
F68Q, F69Q:
Draw Slow Backwash/
Tank Control
Injector Injector Rate Rinse Fast Rinse
Dia. BLFC Optional DLFC Valve
Mode Color
mm L/m L/m L/m Model
40
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
F116Q,F117Q:
Tank Draw Slow Backwash/FastControl
Injector Injector
Dia. Rate Rinse BLFC Optional DLFC Rinse Valve
Mode Color
mm L/m L/m L/m Mode
F116Q, F117Q:
No. 8468076 8468075 8468057 8468056 8468052 8468053 8468054 8468055
Flow
rate 0.30 0.58 0.68 1.32 1.55 2.95 5.00 5.67
L/m
41
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
42
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
44
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
application.
45
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
B. Parameter Setting
In program inquiry mode, press and enter into program set
mode. Press or can adjust the value.
46
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
47
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
For example,a softener has set fast rinse time as 12 minutes. After
regenerating, the chloridion in the outlet water is always higher than
normal, which indicates that the fast rinse is too short. If you want to set
the time as 15 minutes, the modification steps as follows:
① Press and hold both and to unlock the button (The
fourth decimal point of digital tube lights off);
② Press ,the third decimal point of digital tube lights on;
48
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
49
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
Note:
When the control valve enters into the regeneration status, all
programs can be finished automatically according to the setting
time; if you want one of steps to be terminated early, you can press
.
If water inflows too fast, the media in tank will be damaged. When
water inflows slowly, there is a sound of air emptying from drain
pipeline.
After changing resin, please empty air in the resin according to
above step C.
In the process of trial running, please check the water situation in
50
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
all positions, and ensure there is no resin leakage.
The time of Backwash, Brine & Slow Rinse, Fast Rinse and Brine
Refill status can be set and executed according to the calculation in
the formula or suggested from the control valve suppliers.
51
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
3.7 Trouble-Shooting
52
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
A. Setting the appropriate amount
5. Unit used A. Improper salt setting.
of salt for primary regeneration.
too much B. Excessive water in brine
B. See problem No.6.
salt. tank.
53
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
brine. faulty. C. Check and find the reason.
C. Air in resin tank. D. Clean the floccules in resin
D. Floccules in resin tank tank.
during up-flow
regeneration.
A. Foreign material in valve
which makes valve can’t be A. Clean foreign material in valve
closed completely. body.
12. Water B. Hard water mixed in B. Change valve core or sealing
valve body. ring.
flows out
C. Water pressure is too C. Reduce water pressure or use
from drain or
high which results in valve pressure release function.
brine pipe
not getting the right status. D. Add check valve or solenoid
after
D. When in backwash valve in the outlet, or liquid level
regeneration.
status, drain line is controller in the brine tank.
communicated with brine
line.
54
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
B. Controller Fault
Problem Cause Correction
A. Replace control board.
A. Control board is faulty.
1. All indictors B. Check and replace
B. Transformer damaged.
display on front transformer.
C. Electrical service is not
panel. C. Check and adjust
stable.
electrical service.
A. Wiring of control board with A. Check and replace
transformer fails to work. wiring.
2. No display on
B. Control board damaged. B. Replace control board.
front panel. C. Transformer damaged. C. Replace transformer.
D. Electrical service is off. D. Check electricity.
A. Wiring of locating board with
A. Replace wiring.
control board fails to work.
B. Replace locating board.
B. Locating board damaged.
C. Replace motor gear and
C. Motor gear and big gear
big gear.
damaged.
3. Show E1 D. Replace control board.
D. Control board damaged.
E. Replace wiring.
E. Wiring of motor with control
F. Replace motor.
board is fault.
G. Reset power
F. Motor damaged.
G. Set wrong model.
4. Show E3 or
A. Control board is faulty. A. Replace control board.
E4
55
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
56
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
57
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
58
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
F67Q3 Valve Body Components and No.[F67Q1 doesn't have No.17, 30 and 31,
and change No. 10 from 8865174 (630) to 8865175 (631)]
Ite Qu Qu
Item
m Description Part No. anti Description Part No. anti
No.
No. ty ty
638601
1 O-ring 73×5.3 8378143 1 17 Probe Wire 1
4
Screw, Cross 890901
2 O-ring 25.8×2.65 8378078 1 18 1
ST3.9×13 3
Valve Body
8022039
(ABS+GF10) 824103
3 1 19 Gear 1
Valve Body 4
8022040
(PPO+GF20)
Screw, Cross 890900
4 Seal Ring 8371001 4 20 2
ST2.9×16 8
638003
5 Motor 6158021 1 21 Locating Board 1
2
Screw, Cross 809200
6 8909016 4 22 Fitting Nut 1
ST3.9×16 4
837812
7 Small Gear 8241003 1 23 O-ring 73×3.55 2
8
837818
8 Pin 8993003 1 24 O-ring 38.7×3.55 2
4
Anti-friction 821600
9 Wire for Power 5513001 1 25 1
Washer 4
825800
10 Label 8865175(631) 1 26 Shaft 1
4
845901
11 Front Cover 8300060 1 27 Moving Disk 1
4
Wire for Locating 846901
12 5511021 1 28 Fixed Disk 1
Board 3
837002
13 Cable Clip 8126004 2 29 Seal Ring 1
7
845820
14 Control Board 6382159 1 30 Connector 1
5
Screw, Cross 544701
15 8909004 2 31 Flow Meter 1
ST2.2×6.5 8
16 Dust Cover 8005091 1
59
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
60
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
F68Q3 Valve Body Components and No.[F68Q1 doesn't have No.16, 30 and
31, and change No. 9 from 8865174 (630) to 8865175 (631)]
Ite Qu Ite Qu
m Description Part No. anti m Description Part No. anti
No. ty No. ty
1 O-ring 73×5.3 8378143 1 27 Moving Disk 8459078 1
2 O-ring 25.8×2.65 8378078 1 28 Fixed Disk 8469079 1
Valve Body
5022022
(ABS+GF10)
3 1 29 Seal Ring 8370111 1
Valve Body
5022023
(PPO+GF20)
Animated
4 Motor 6158011 1 30 5457002 1
Connector
Screw, Cross
5 8909016 4 31 Flow Meter 5447018 1
ST3.9×16
6 Small Gear 8241003 1 32 Seal Ring 8371001 2
7 Pin 8993003 1 33 Plug 8323002 1
8 Wire for Power 5513001 1 34 Seal Ring 8370003 1
8865175
9 Label 1 35 BLFC 8468055 1
(631)
10 Front Cover 8300060 1 36 O-ring 11×2 8378169 1
Wire for Locating
11 5511021 1 37 Connector 8458068 1
Board
12 Cable Clip 8126004 2 38 Tube 8457004 1
13 Control Board 6382159 1 39 Hex Nut 8940001 1
Screw, Cross
14 8909004 2 40 Animated Nut 8945025 1
ST2.2×6.5
15 Dust Cover 8005091 1 41 Connector 8458064 1
16 Probe Wire 6386014 1 42 O-ring 15×1.8 8378179 1
Screw, Cross Without this
17 8909013 1 43 DLFC 1
ST3.9×13 part
18 Gear 8241053 1 44 Clip 8270010 1
Screw, Cross Screw, Cross
19 8909008 2 45 8902017 2
ST2.9×16 M5×35
20 Locating Board 6380032 1 46 Cover of Injector 8315001 1
21 Fitting Nut 8092004 1 47 O-ring 30×1.8 8378025 1
22 O-ring 73×3.55 8378128 2 48 Nozzle, Injector 8454008 1
23 O-ring 38.7×3.55 8378184 2 49 Throat, Injector 8467008 1
24 Anti-friction Washer 8216004 1 50 Injector Body 8008010 1
O-ring
25 Shaft 8258004 1 51 8378012 1
10.82×1.78
61
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
62
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
63
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
F69Q3 Valve Body Components and No.[F69Q1 doesn't have No.18, 31 and
32, and change No. 10 from 8865176 (632) to 8865177 (633)]
Ite Qu
Item Qua
m Description Part No. anti Description Part No.
No. ntity
No. ty
837814 837005
1 O-ring 73×5.3 1 27 Moving Seal Ring 1
3 3
837807 845901
2 O-ring 25.8×2.65 1 28 Moving Disk 1
8 6
Valve Body 502202
(ABS+GF10) 4 846901
3 1 29 Fixed Disk 1
Valve Body 502202 5
(PPO+GF20) 5
837101 837003
4 Seal Ring 3 30 Seal Ring 1
9 4
832300 545700
5 Plug 1 31 Animated Connector 1
5 3
615800 544702
6 Motor 1 32 Flow Meter 1
6 0
Screw, Cross 890901 832300
7 4 33 Plug 1
ST3.9×16 6 2
824101 837000
8 Small Gear 1 34 Seal Ring 1
0 3
899300 846805
9 Pin 1 35 BLFC 1
3 3
886517 837816
10 Label 1 36 O-ring 11×2 1
7(633) 9
830005 845806
11 Front Cover 1 37 Connector 1
9 8
Wire for Locating 551102 845700
12 1 38 Tube 1
Board 1 4
638215 894000
13 Control Board 1 39 Hex Nut 1
9 1
Screw, Cross 890900 894502
14 2 40 Animated Nut 1
ST2.2×6.5 4 5
800500 845806
15 Dust Cover 1 41 Connector 1
5 4
812600 837817
16 Cable Clip 2 42 O-ring 15×1.8 1
4 9
551300 846807
17 Wire for Power 1 43 DLFC 1
1 7
638601 827001
18 Probe Wire 1 44 Clip 1
4 0
Screw, Cross 890901 Screw, Cross 890201
19 1 45 2
ST3.9×13 3 M5×35 7
824105 831500
20 Gear 1 46 Cover of Injector 1
3 1
21 Screw, Cross 890900 5 47 O-ring 30×1.8 837802 1
64
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
ST2.9×16 8 5
638003 845400
22 Locating Board 1 48 Nozzle, Injector 1
3 4
809200 846700
23 Fitting Nut 1 49 Throat, Injector 1
7 4
837810 800801
24 O-ring 50.39×3.53 1 50 Injector Body 1
7 0
Anti-friction 821601 837801
25 1 51 O-ring 10.82×1.78 1
Washer 0 2
825800 837801
26 Shaft 1 52 O-ring 7.5×1.8 2
9 6
65
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
66
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
F71Q3 Valve Body Components and No.[F71Q1 doesn't have No.16, 28 and 29,
and change No. 8 from 8865176 (632) to 8865177 (633)]
Ite Qu
Item Qua
m Description Part No. anti Description Part No.
No. ntity
No. ty
1 O-ring 73×5.3 8378143 1 16 Probe Wire 6386014 1
Screw, Cross
2 O-ring 25.8×2.65 8378078 1 17 8909013 1
ST3.9×13
Valve Body
8022048
(ABS+GF10)
3 1 18 Gear 8241038 1
Valve Body
8022049
(PPO+GF20)
Screw, Cross
4 Motor 6158006 1 19 8909008 5
ST2.9×9.5
Screw, Cross
5 8909016 4 20 Locating Board 6380033 1
ST3.9×16
6 Small Gear 8241010 1 21 Fitting Nut 8092007 1
O-ring
7 Pin 8993003 1 22 8378107 1
50.39×3.53
8865177 Anti-friction
8 Label 1 23 8216010 1
(633) Washer
9 Front Cover 8300059 1 24 Shaft 8258009 1
Wire for Locating
10 5511021 1 25 Moving Disk 8459019 1
Board
11 Control Board 6382159 1 26 Fixed Disk 8469018 1
Screw, Cross
12 8909004 2 27 Seal Ring 8370038 1
ST2.2×6.5
13 Dust Cover 8005005 1 28 Connector 8458206 1
14 Cable Clip 8126004 2 29 Flow Meter 5447020 1
15 Wire for Power 5513001 1
67
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
68
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
F116Q3 Valve Body Components and No.[F116Q3 doesn't have No.16, 30 and
31, and change No. 9 from 8865174 (630) to 8865175 (631)]
Ite Qu Ite
Qua
m Description Part No. anti m Description Part No.
ntity
No. ty No.
69
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
70
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
71
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
73
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
4. Warranty Card
Dear client:
This warranty card is the guarantee proof of Runxin brand
multi-functional flow control valve. It is kept by client self. You could get
the after-sales services from the supplier which is appointed by Runxin
manufacturer. Please keep it properly. It couldn’t be retrieved if lost. It
couldn’t be repaired free of charge under the below conditions:
1. Guarantee period expired. (One year)
2. Damage resulting from using, maintenance, and keeping that are not
in accordance with the instruction.
3. Damage resulting from repairing not by the appointed maintenance
personnel.
4. Content in guarantee proof is unconfirmed with the label on the real
good or be altered.
5. Damage resulting from force majeure.
Product Multi-functional Flow Control Valve
Name for Water Treatment Systems
Code of
Model
Valve Body
Purchase
Company Tel/Cel.
Name
Problem
Solution
Maintenance
Date of Date of
Man
Repairing Examination
Signature
When product needs warranty service, please contact with your
direct supplier first, after got permission, then fill in the below content and
74
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q
send this card together with the product to the appointed suppliers or
Runxin company.
End-user
Company Tel/Cel.
Name
Purchase
Company Tel/Cel.
Name
Model Code of Valve Body
Resin Tank Size Raw Water Hardness
Tank Size φ ×
L mmol/L
Water Source:
Water Treatment Backwash Time
Ground-water □ Tap
Capacity m3 min
Water □
Brine & Slow Rinse Time Brine Refill Time Fast Rinse Time
min min min
Problem
Description
Rev.A.1902
75
MODEL:F67Q/F71Q/F68Q/F69Q/F116Q/F117Q