Taiwan Main Orthopaedic Biotechnology Co., Ltd.
CADUCEUS S AR NAVIGATION
Revolution on Spine Surgery
SURGLASSES
1
Today’s challenge in spine surgery
Before navigation system
1. Radiation exposure
2. Time consuming : take more than 4 hours to finish
3. Precision : Relies on the surgeon's skill and
experience; precision may vary.
4. Invasiveness : Often involves larger incisions,
leading to more tissue disruption.
5. Slow recovery : Longer recovery periods due to the
invasive nature of the surgery.
2
Caduceus S AR Navigation
Caduceus : World’s first MR surgical platform
3D Organs Superimposed
System can show 3D images of
patient’s data image and can be
put on patient’s body
Focus & AR
Surgeon can focus on the patient,
and smart glasses allows surgeon to
see through the patient’s body
without look up at the external
monitor.
3
Caduceus S AR Navigation
98.2% Clinical
accuracy*
1.5 – 2 mm Navigation
accuracy
Regulatory
FDA 510(k) Dec. 16 Clearance
TFDA Aug. 15, 2022 Clearance
Thailand FDA Dec, 2023
*Chang et al. 2022
4
WHY SHOULD YOU
CHOOSE US?
C-arm Module
No need preoperative CT or intraoperative CT
Compatibility
The system can be registered with any medical
imaging device like C-arm and O-arm. Any C-arm
can be compatible with Caduceus as long it has
video input/output.
Smart AR Glasses
Just focus on the patient’s affected area without
looking up at the screen all the time
Radiation Reduction
It only take 2-4 images of the lateral and AP view at the
beginning of the operation
5
WHY SHOULD YOU
CHOOSE US?
Teaching Application
Operation system is easy and can reduce learning
curve of doctor.
AR and MR Technology
System can show 3D images of patient’s data image
and can be put on patient’s body
Preoperative Simulation
Importing the DICOM data of the patient into the
system can perform preoperative simulation, assist
the surgeon in analyzing the surgical plan.
Simple Workflow
All you need is C-arm device, get the basic configuration
for positioning surgical area (AP and Lateral). Set up time
is about 10-15 minutes.
6
Product Specification
Caduceus S AR Navigation system
TFDA Class II
Clearance 2022.8.12
720p AR
500 g weight
5G WIFI
4 hours battery
Surgical planning
software
TFDA Class II
Toolkits
Headset Workstation
CE Class I TFDA Class II
FDA510K Class II (Q4/2022)
7
Caduceus S AR Navigation System software
8
C-arm Module
Navigation can be used with a single C-arm capturing 2-4 images
for localization.
No preoperative CT scans or intraoperative CT scans are required.
Registration time is less than 15 minutes
Suitable for short-segment spinal surgeries.
Multiple images can be captured at different angles for True
Anterior-Posterior (AP) views targeting various spinal segments.
9
10
Pre-CT module
• DICOM image can be imported into system and
surgeon can be able to do preoperative planning
• Capture 2-4 C-arm images intraoperatively.
• Automatic registration.
• Registration time is less than 15 minutes.
• Applicable for both short and long-segment spinal
surgeries, particularly for surgeries requiring Axial
views.
11
Hybrid Module
Can use 3D C-arm for scanning the surgical area.
Suitable for challenging spinal surgeries involving both long and short segments,
Registration : less than 15 minutes
12
13
Intra-operative CT (MR Module)
Can import patient’s CT image into Caduceus S AR and the data can be viewed as 3D data.
The result of 3D data can be superimposed on the patient’s body. Thus, surgeon can see
through the patient’s body.
Applicable for challenging spinal surgeries involving both long and short segments,
especially those with difficult aspects such as significant spinal curvature or rotation.
Registration : less than 15 minutes
Thank You For Your Attention