26230
3/2 and 5/2 (reversible seal: Modular NAMUR design)
Actuation: Electromagnetic
Indirectly -controlled soft seal spool valves
Connections G 1/4, 1/4 NPT
● For single- and double-acting drives
● Reversible seal for 3/2 or 5/2 function
● Manual override with detent as standard
● Compact design
● Exhaust air silencers
● Simple design of soft spool seal system
● Maintenance-free
● Easily interchangeable solenoid system
● Exhaust air recirculation
Technical data Ordering example
Operating medium: 5/2 directional control valve, connection G 1/4,
Solenoid valve for filtered, lubricated1) or non- actuating magnet 24 V DC, with connector
lubricated air DIN 43650 form B, Protection class IP 65
Actuation: Part No.: 2623079.3051.024.00
Solenoid operated, indirectly controlled
Flow direction: Connectors
Fixed
See data sheet 7503364
Mounting position:
Optional
Nominal size:
6 mm 3/2 5/2
Port size: 42 42
G 1/4, 1/4 NPT
Electrical connection:
Connector interface to DIN 43650 form A and B 513 513
Operating pressure:
Max. 10 bar
Temperature range:
-10* to +50 °C
* With minus temperatures, use conditioned dry air. If installed in the open
protect all connections against the penetration of moisture!
Material:
Housing: Aluminium anodized
Pilot flange: Plastic (PBT)
Seals: NBR (Perbunan)
1) Oil recommendation:: Shell Hydrol DO 32, ESSO Febis K 32 (as of July 1992) or
comparable oils with DVI-values <8 (DIN 53521) and ISO viscosity class 32-46
(DIN 51519).
Our policy is one of continued research and development. We therefore reserve the right
7503369.06-1 to amend, without notice, the specifications given in this document. 8/99
26230 with reversible seal
General information
Valve for solenoid actuator Group ‘A’
Symbol Type * Port size Function Nom. size Operating pressure (bar) kv-value Weight Dimensional
1, 3 ( 5) 2 (4) Min. Max. (Cv (US) ≈ kv x 1,2) (kg) drawing
42
14 12
2623079 G 1/4 Flange Solenoid 6 2 8 1,2 0,4 M01
513 2623080 1/4 NPT Flange indirectly-contr. 6 2 8 1,2 0,4 M01
42
14 12 2623179 G 1/4 Flange 2x solenoid 6 2 8 1,2 0,9 M02
indirectly contr.
513
Valve for solenoid actuator Group ‘B’
42
2636015 G 1/4 Flange Solenoid 6 1 10 1,2 0,55 M03
14 12
2636016 1/4 NPT Flange indirectly-contr. 6 1 10 1,2 0,55 M03
513
* When ordering please indicate solenoid, voltage and current type (frequency).
Solenoid actuator Group ‘A’
Type Current draw Protection class Temperature Weight Dimensional Picture
24 V DC 230 V AC Fluid max. Ambience drawing
(W) (VA) (°C) (°C) (kg)
3050 1,7 5,6/4,3 IP 00 without +50 -15 to +50 0,06 M04 SB01
connector
3051 1,7 5,6/4,3 IP 65 with conn. +50 -15 bis +50 0,08 M04 SB01
to DIN 43650
form B
3036 1,6 4,55/3,5 IP 00 without +50 -15 to +50 0,09 M05 SB01
connector
3037 1,6 4,55/3,5 IP 65 with conn. +50 -15 to +50 0,12 M05 SB01
to DIN 43650
form A
3042 3,3 – EEx m II T6 +80 -15 to +50 0,13 M06 SB01
with cable 3 m
3043 – 3,3 EEx m II T6 +80 -15 to +50 0,13 M06 SB08
with cable 3 m
Standard voltage 24 V DC, 230 V AC. Other voltages on request.
Solenoid actuator Group ‘B’
Type Current draw Current Tolerance (%) Protection class Temperature Weight Dimensional Picture
24 V DC 230 V AC 24 V DC 230 V AC Nominal voltage Fluid max. Ambience drawing
(W) (VA) (mA) (mA) + - (°C) (°C) (kg)
0242 IP00 without conn. 0,15
2,7 - 113 - 10 10 +80 -25 to +60 M07 SB01
0240 IP65 with connector 1) 0,18
0245 IP00 without conn. 0,15
- 10/4,2 - 45/18 10 10 +80 -25 to +60 M07 SB01
0241 IP65 with connector 1) 0,18
EEx m II T4
0278 3,2 - 135 - 10 15 +70 -20 to +70 0,4 M8 SB04
3m cable
EEx m II T4
0279 - 3,5 - 15 10 15 +70 -20 to +70 0,4 M8 SB07
3m cable
-20 to +80 (T5)
3910 3,9 - 161 - 10 20 EEx me II T5/T6 0,85 M9 SB04
-40 to +60 (T6)
-20 to +80 (T5) 0,85 M9 SB07
3911 - 4,9 - 21 10 15 EEx me II T5/T6
-40 to +60 (T6)
Standard voltage 24V DC; 24 V, 110 V, 230 V 50 Hz; 120 V, 220 V 60 Hz. Other voltages on request.
1) Connector DIN 43650 Form A
Our policy is one of continued research and development. We therefore reserve the right
7503369.06-2 to amend, without notice, the specifications given in this document. 8/99
26230 with reversible seal
Dimensional drawings: Valves
M01
14
Manual override
1 1
0 0
143,5
G 1/4
2
Ø 5,5
24
1
12
Ø 19,5
4
Ø 13
24
35
35
5
M5
32 3 5
55 37 5
M02
14
Manual override
1 1
0 0
3
2 G 1/4
Ø 5,5
24
223
1
12
Ø 19,5
4
Ø 13
24
35
35
5
M5
0 0
5
1 1
Manual override
12
32 3 5
55 37
Our policy is one of continued research and development. We therefore reserve the right
7503369.06-3 to amend, without notice, the specifications given in this document. 8/99
26230 with reversible seal
Dimensional drawings: Valves
M03
5 18,5
(14)
Manual override 14
with detend
without detend
1
0
143
G 1/4
Ø 5,5
2
24
12
1
12
4
Ø 19,5
Ø13
24
35
35
5
M5
32 3 5
55 37
Dimensional drawings: Solenoids
M04 M05
29 36
29,5
29,5
11 15
65 12 72 12
30
22
Ø9 Ø9
M06 M07
74
38
36
15,5
40,5
29,5
55
15
Connector rotates
68 4 x 90° 12
Pg 11
29,5
27,5
30
Ø9 18
Our policy is one of continued research and development. We therefore reserve the right
7503369.06-4 to amend, without notice, the specifications given in this document. 8/99
26230 with reversible seal
M08 M09
6
41
41
60
80
82,5
89 Ø16*
* Ø13 (with spacer tube)
63 33
Pg 13,5
33
119
19,5
63,5
73
62
66
Electrical circuit diagrams
SB01 SB04 SB07 SB08
NAMUR interface
32
Thread M5 8 deep
24
Coding stud
M5x10 DIN 913-45 H
12
8
M5
2
G1/4
DIN/ISO 228/1
Mounting accessories
Description Part No. Application Weight See
(kg) data sheet
Flange plate 0559857 Direct mounting on pneumatic linear actuators with NAMUR ribbing and for wall 0.50
mounting, depending on piping position 7502242
Yoke 0540593 In conjunction with flange plate for mounting on pneumatic linear actuators with NAMUR pillar (round) 0.10
Spacer plate 0540109 Direct attachment to pneumatic rotary actuators, e.g. when using a solenoid with a terminal box 0.25
Part Nos. 3910 or 3911
Adapter plate 0559853 Direct mounting on older designs of pneumatic rotary actuators with hole pattern corresponding to valves 0.18
with Part Nos. 2636055, -56, -64
Silencer 0014600 Port size G 1/4, back pressure max. = 6 bar 0.01 7501080
Our policy is one of continued research and development. We therefore reserve the right
7503369.06-5 to amend, without notice, the specifications given in this document. 8/99
26230 with reversible seal
Our policy is one of continued research and development. We therefore reserve the right
7503369.06-6 to amend, without notice, the specifications given in this document. 8/99
26230 with reversible seal
Our policy is one of continued research and development. We therefore reserve the right
7503369.06-7 to amend, without notice, the specifications given in this document. 8/99
26230 with reversible seal
Our policy is one of continued research and development. We therefore reserve the right
7503369.06-8 to amend, without notice, the specifications given in this document. 8/99