Installation
Manual
Montageanleitung
Instructions de montage
Istruzioni per il montaggio
Product Data 193/4" 43/4"
23/8"
(60)
(500) (120)
Product Specifications
NPT
Geberit Model No. 111.335.00.5 1/2"
Concealed tank and bowl carrier, wall-hung two-hole toilet
bowl and actuator plate.
Tank and carrier system shall fit within a minimum 6 3/4" 263/8"
(170) deep wall with studs placed 19 3/4" (500) apart, 71/8"–9" (670)
(180–230) 22"
water supply shall be 1/2" copper, minimum water 4" 47"–51" (558)
pressure 35 PSI. The bowl shall be an IAMPO listed 1.6 (100) (1195–1297) FRH
gallon (6 l) per flush wall-hung bowl.
The carrier shall have adjustable height for 15" (381) to 19"
(483) bowl rim height. Actuator plates shall be die-cast X
12"–16"
zinc, plastic or stainless steel and plated to preserve the (305–407) Finishd Rim Height (FRH)
material’s integrity. FRH = X plus 3"
FF
Stud Front
Center Pipe
min 4" 31/2"–53/16"
(100) (90–135)
Features Material Determination
• Square structural 16 gauge powder coated steel frame Recommended material for wall surface construction:
• Water consumption: Dual flush system allows for
• Gypsum / green board
0.8 GPF (3 l) or 1.6 GPF (6 l)
• Cement board
• Actuator dimension: 9 5/8" (254) width
• Tile backer board
6 1/2" (165) height
• Ceramic tile surface
• Carrier height adjustable range 15" (381) to 19" (483)
bowl rim height
• Impact resistant high density polyethylene tank HDPE
• Insulated to prevent condensation Wall thickness not to exceed 3"
• Anti-siphon fill valve meets ANSI / ASSE 1002-99
standard
Options
71/16" Sigma01 Dual flush actuator; white 115.770.11.5
(180) 53/16" Sigma01 Dual flush actuator; chrome 115.770.21.5
(135) a01
Sigm
3" (75) Rumba Single flush actuator; white 115.750.11.1
4" (100) Rumba Single flush actuator; chrome 115.750.21.1
ba
Rum
X Tango Single flush actuator; chrome 115.760.21.1
FF Tang
o
Sigma10 Single flush actuator; withe 115.758.KL.1
10
Sigma
Warranty
Sigma20 Dual flush actuator; white 115.778.KH.1
Limited lifetime warranty on tank and carrier.
10 year warranty on fill valve and flush valve.
20
One year warranty on actuator plate. Sigma
Sigma50 Dual flush actuator; white 115.788.11.1
50
Sigma
D54386-001 © 04-2012
Vertical discharge elbow 3" DWV standard
- Horizontal left: 366.914.16.1
- Horizontal right: 366.913.16.1
2
Installation 2
Installation Requirements
To install tank and carrier, a 2 x 6" wood frame or metal
frame construction is required. Studs must be placed 19 3/
4" apart (clearance) where carrier will be positioned inside
the wall.
Bowl Finished Rim Height (FRH)
Remove carrier and installation hardware from its box.
Determine FRH for wall-hung bowl and adjust carrier
height in accordance with requirement. Dimensions can be 3 A B
taken from bowl or carrier specification sheet. Be sure to
allow for finished floor and sole plate height.
Discharge elbow installation
31/2"-43/4" 41/8"-53/16"
(90-120) (105-135)
C D
E F
1 31/2"-43/4" 41/8"-5
"-53/16"
(90-120) (105-135)
4
D54386-001 © 04-2012
3
Tank and carrier installation
3/4"
19
1 Locate carrier supporting studs and reinforce with
additional nails. Ensure rough-in for the carrier is
plumb and square. Wall framework must be affixed
to the floor and ceiling for maximum support. C
2 Position carrier unit in the prepared opening.
Carrier face plate must be flush with the front of the
surrounding studs so that maximum support for
5/16"
the wall sheeting (applied later) will be
accomplished. With carrier still in place, mark all 1"
47"–5
anchor and bolt hole locations on sole plate and
studs. Mark location for the 3" DWV discharge
pipe.
3 Pull out carrier from framework and drill six (6) pilot
holes (3/16") for the supplied lag screws where
5/16"
marked on sole plate. Also drill six (6) bolt holes (5/
16") where marked on both studs. Use hole saw
6"
and bore a 4" hole through sole plate and floor for 12"–1
the discharge stop out pipe.
F.F.
4 Install 3" DWV waste pipe through floor and
connect to waste line (i.e. PVC, copper, cast iron).
5 Set carrier unit sideways back into framework and
bolt in place with hardware provided.
6 Complete waste elbow connection with 3" DWV
shielded coupling (D - provided) to waste pipe.
D
0°− °
45° 45
0°−
A Install 1/2" rods with plastic sleeves,
B pipe plugs and
7 Install two (2) 1/2" x 6" fixture support rods with
plastic sleeves (A), yellow pipe caps (B) and mud C mud guard during the rough-in installation
guard (C) for protection during wall surface D Complete waste elbow connection with 3" DWV
construction. shielded coupling (D - provided) to waste pipe.
For finishing the installation of bowl and actuator
plate see detailed instructions.
D54386-001 © 04-2012
4
Water supply installation
4
1
R½
2 R½
NPT 1/2" elbow
D54386-001 © 04-2012
5
6 A 7
8
B
9 Install wall surface material such as high density
Gypsum / green Board, Cement Board, Tile
2 Backer Board with optional ceramic tile finish
surface as the most suitable materials. Provide cut
outs for the protruding parts like inlet and outlet
pipes and the rectangular access box.
D54386-001 © 04-2012
6
Bowl installation
4 Add dimension X and 1/8". Using that dimension,
mark a line on the pipe measuring from the hub
1 Remove yellow protection plugs and seals from
pipes.
side. Cut off the pipe at the line with a pipe cutter.
1
X
2 +1/8"
+(3 mm)
X
5 Add dimension Y and 1/8". Using that dimension,
mark a line on the pipe measuring from the hub
side. Cut off the pipe at the line with a pipe cutter.
2 Insert discharge pipe into the pipe hub in the wall.
Place a straight edge flush against the wall and
1
2
mark a line on the pipe. Fit finned rubber seal onto +1/8" Y
flush pipe. Repeat same procedure for discharge +(3 mm)
pipe.
Y
2
6 Bevel the sharp edges as shown to assure a
smooth insertion into the pipe hubs in the wall.
2
1
3 Place discharge pipe with gasket into waste outlet
of bowl. Also place flush pipe with fin gasket into
inlet of bowl. Then mark a second line on both
pipes.
2 7 Install both seals into the pipes in the wall.
Lubricate seals with appropriate rubber seal
lubricant.
1 2
1
D54386-001 © 04-2012
7
8 Remove protective sleeves from mounting rods.
Determine protruding rod length for bowl installation.
Install both pipes into the hubs in the wall.
2 A
3
1
2
+13/16"
+(20 mm)
CAUTION
High torque forces
– WC ceramic appliance may break
` Do not overtighten hex nuts.
9 Place bowl onto rods. Attach cap washer with nose
up and facing forwards onto rods. Install washer
and hex nuts, tighten loosely. Level bowl. Tighten
hex nuts. Snap on the bolt caps.
10 Seal gap around bowl with waterproof sealant.
Sound insulation pad is optional or required.
2
Contact
Geberit
2100 Clearwater Drive, Des Plaines, IL 60018-5999
www.geberit.us
Phone: (847) 803 5000 • Fax: 847/803-5454
For Technical Assistance:
800 / TEC-TRUE (800-832-8783)
2
996.506.00.0 (03) Geberit International AG, Schachenstrasse 77, CH-8645 Jona
D54386-001 © 04-2012
[email protected] ➔ www.geberit.com