Cisco HyperFlex Express HX240C M6 All NVMe, AllFlash and Hybrid Server Nodes
Cisco HyperFlex Express HX240C M6 All NVMe, AllFlash and Hybrid Server Nodes
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Chassis Front View - HXAF240C-M6SN-EXP (All NVMe) . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Chassis Rear View - HXAF240C-M6SN-EXP (All NVMe) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Chassis Front View - HXAF240C-M6SX-EXP (All Flash) . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Chassis Rear View - HXAF240C-M6SX-EXP (All Flash) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Chassis Front View - HX240C-M6SX-EXP (Hybrid) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Chassis Rear View - HX240C-M6SX-EXP (Hybrid) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
BASE SERVER NODE STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . 16
CONFIGURING the SERVER (User Selectable) . . . . . . . . . . . . . . . . . . . . . . . 19
STEP 1 VERIFY SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
STEP 2 SELECT CPU(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
STEP 3 SELECT MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
STEP 4 SELECT DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
STEP 5 ORDER POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
STEP 6 SELECT INPUT POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
STEP 7 SELECT HYPERFLEX DATA PLATFORM SOFTWARE EXPRESS . . . . . . . . . . . . . . . . . . 39
STEP 8 CISCO INTERSIGHT™ SaaS EXPRESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
STEP 9 SELECT SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Risers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Riser Card Configuration and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
SPARE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
UPGRADING or REPLACING CPUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
UPGRADING or REPLACING MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Extended Operating Temperature Hardware Configuration Limits . . . . . . . . . . . . . . . . . . . 69
Compliance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
2 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server
OVERVIEW
OVERVIEW
Cisco HyperFlex™ Systems unlock the full potential of hyperconvergence. The systems are based on an
end-to-end software-defined infrastructure, combining software-defined computing in the form of Cisco
Unified Computing System (Cisco UCS) servers; software-defined storage with’ the powerful Cisco HX Data
Platform and software-defined networking with the Cisco UCS fabric that will integrate smoothly with Cisco
Application Centric Infrastructure (Cisco ACI™). Together with a single point of connectivity and hardware
management, these technologies deliver a preintegrated and adaptable cluster that is ready to provide a
unified pool of resources to power applications as your business needs dictate.
The Cisco HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes extends the capabilities of
Cisco’s HyperFlex portfolio in a 2U form factor with the addition of the 3rd Gen Intel® Xeon® Scalable
Processors (Ice Lake), 16 DIMM slots per CPU for 3200-MHz DDR4 DIMMs with DIMM capacity points up to 64
GB. The maximum memory capacity for 2 CPUs is listed here:
Drive Controller
The server provides one or two internal slots (depending on the server type) for the following:
■ Two slots for Cisco 12G SAS pass-through HBAs. Each HBA controls up to 16 SAS/SATA drives
The HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes has two LOM ports (10Gbase-T
LOM) and a single 1 GbE management port. A modular LAN on motherboard (mLOM) module provides up to
two 100 GbE ports. A connector on the front of the chassis provides KVM functionality.
See Figure 1 on page 4 for front and rear views of all the configurations of the HyperFlex Express HX240C
M6 All NVMe/All Flash/Hybrid Server Nodes.
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 3
OVERVIEW
Figure 1 Cisco HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes
Rear View (all slots shown unpopulated - see Figure 3 on page 7 for details)
4 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
OVERVIEW
Figure 1 Cisco HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes
Rear View (all slots shown unpopulated - see Figure 5 on page 10 for details)
HX240C-M6SX-EXP (Hybrid)
24 Front drives are SAS/SATA HDDS & SSDs and optionally 4 SAS/SATA rear drives
Rear View (all slots shown unpopulated - see Figure 7 on page 14 for details)
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 5
DETAILED VIEWS
DETAILED VIEWS
Chassis Front View - HXAF240C-M6SN-EXP (All NVMe)
Figure 2 shows the front View of the HXAF240C-M6SN-EXP (All NVMe) Server configured with 24 SFF NVMe
front drives and optionally two rear capacity drives. The drives are all NVMe drives.
Notes:
1. When NVMe drives are selected, you must also select 2 CPUs.
6 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
DETAILED VIEWS
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 7
DETAILED VIEWS
8 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
DETAILED VIEWS
1-4 Drive bays 1 – 4 support SAS/SATA solid state 9 System status LED
drives (SSDs) as well as NVMe PCIe drives1
Notes:
1. If NVMe drives are selected, you must also select 2 CPUs.
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 9
DETAILED VIEWS
10 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
DETAILED VIEWS
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 11
DETAILED VIEWS
12 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
DETAILED VIEWS
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 13
DETAILED VIEWS
14 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
DETAILED VIEWS
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 15
DETAILED VIEWS
16 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
BASE SERVER NODE STANDARD CAPABILITIES and FEATURES
Note: Not all risers are available in every server configuration option.
For more details on the variations of riser 1, riser 2, and riser 3, see Riser Card
Configuration and Options, page 48.
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 17
BASE SERVER NODE STANDARD CAPABILITIES and FEATURES
Capability/
Description
Feature
Interfaces ■ Rear panel
• One 1Gbase-T RJ-45 management port
• Two 10Gbase-T LOM ports
• One RS-232 serial port (RJ45 connector)
• One DB15 VGA connector
• Two USB 3.0 port connectors
• One flexible modular LAN on motherboard (mLOM) slot that can accommodate
various interface cards
■ Front panel
• One KVM console connector (supplies two USB 2.0 connectors, one VGA DB15
video connector, and one serial port (RS232) RJ45 connector)
Internal Drive storage:
storage devices
The server is orderable in three different server node:
HX240C-M6SX-EXP (Hybrid):
■ Up to 24 front SFF hard drives (HDDs) and solid state drives (SSDs). 24 Drives are
used as below:
• Six to twenty-two SAS HDD (for capacity)
• One SAS/SATA SSD (for caching)
• One SAS/SATA SSD (system drive for HXDP operations)
■ Up to 4 SFF rear-facing SAS/SATA drives (Optional)
18 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
BASE SERVER NODE STANDARD CAPABILITIES and FEATURES
Capability/
Description
Feature
Other storage:
■ A mini-storage module connector on the motherboard supports a boot-optimized
RAID controller carrier that holds two SATA M.2 SSDs. Mixing different capacity SATA
M.2 SSDs is not supported. This mini storage is for following usage:
• ESXi hypervisor boot and HyperFlex storage controller VM
Integrated Baseboard Management Controller (BMC) running Cisco Integrated Management
management Controller (CIMC) firmware.
processor
Depending on your CIMC settings, the CIMC can be accessed through the 1GE dedicated
management port, the 1GE/10GE LOM ports, or a Cisco virtual interface card (VIC).
CIMC manages certain components within the server, such as the Cisco 12G SAS HBA.
Storage Two 12G SAS HBAs plug into a dedicated slot.
controllers
■ Cisco M6 12G SAS HBA (for Hybrid and All Flash servers):
• No RAID support
• JBOD/Pass-through Mode support
• Each HBA supports up to 16 SAS/SATA internal drives
Modular LAN on The dedicated mLOM slot on the motherboard can flexibly accommodate the following
Motherboard cards:
(mLOM) slot
■ Cisco Virtual Interface Cards
Intersight Intersight provides server management capabilities
CIMC Cisco Integrated Management Controller 4.2(1) or later
Notes:
1. If NVMe drives are selected, you must also select 2 CPUs.
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 19
CONFIGURING the SERVER (User Selectable)
20 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
CONFIGURING the SERVER (User Selectable)
■ Auto Included: Table 4.a, Table 4.b and Table 4.c shows the auto included component
with the respective nodes.
■ User Select: STEP 2 to STEP 9, please select the components that you want to include with
your selected node.
Table 3 PID of the HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 21
CONFIGURING the SERVER (User Selectable)
NOTE:
■ The Cisco HyperFlex Express HyperFlex Express HX240C M6 All NVMe, All Flash
and Hybrid server nodes:
• Includes 24 drive backplane and other components.
• Does not include power supply, CPU.
■ Use the STEP 2 to STEP 9 on the following pages to configure the server with
the components that you want to include.
22 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
CONFIGURING the SERVER (User Selectable)
Table 4.a lists auto included components with the HXAF240C-M6SN-EXP (All NVMe) Server Node
HX-SYSTEMDRIVE Housekeeping 1
HX-NVME2H-I1000 Cisco 2.5" U.2 1,0 TB Intel P4510 NVMe High Perf. Value Endu 1
Boot Drives
HX-M2-BOOT M2 BOOT 1
PCIe MLOM
HX-M-V25-04 Cisco UCS VIC 1467 quad port 25G SFP28 mLOM 1
Security Option
ESXi Option
Heat Sink
DIMM Blanks
Blanking Panel
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 23
CONFIGURING the SERVER (User Selectable)
Rail Kit
HX-RAIL-M6 Ball Bearing Rail Kit for C220 & C240 M6 rack servers 1
Riser Cards
Security Bezel
24 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
CONFIGURING the SERVER (User Selectable)
Table 4.b lists auto included components with the HXAF240C-M6SX-EXP (All Flash) Server Node
Drive Controller
HX-SAS-240M6 Cisco 12G SAS HBA for (16 drives) w/1U Brkt 2
Drive Cables
HX-SYSTEMDRIVE Housekeeping 1
Boot Drives
HX-M2-BOOT M2 BOOT 1
PCIe MLOM
HX-M-V25-04 Cisco UCS VIC 1467 quad port 25G SFP28 mLOM 1
Rail Kit
HX-RAIL-M6 Ball Bearing Rail Kit for C220 & C240 M6 rack servers 1
Security Option
ESXi Option 1
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 25
CONFIGURING the SERVER (User Selectable)
DIMM Blanks
Blanking Panel
Risers
Riser Cables
Security Bezel
26 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
CONFIGURING the SERVER (User Selectable)
Table 4.c lists auto included components with the HX240C-M6SX-EXP (Hybrid) Server Node.
Drive Controller
HX-SAS-240M6 Cisco 12G SAS HBA for (16 drives) w/1U Brkt 2
Drive Cables
HX-SYSTEMDRIVE Housekeeping 1
Boot Drives
HX-M2-BOOT M2 BOOT 1
PCIe MLOM
HX-M-V25-04 Cisco UCS VIC 1467 quad port 25G SFP28 mLOM 1
Rail Kit
HX-RAIL-M6 Ball Bearing Rail Kit for C220 & C240 M6 rack servers 1
Security Option
ESXi Option
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 27
CONFIGURING the SERVER (User Selectable)
Heat Sink
DIMM Blanks
Blanking Panel
Risers
Riser Cables
Security Bezel
28 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
CONFIGURING the SERVER (User Selectable)
Select CPUs
Notes:
1. UPI = Ultra Path Interconnect.
CAUTION: For systems configured with 3rd Gen Intel® Xeon® Scalable
Processors (Ice Lake) operating above 28o C [82.4o F], a fan fault or executing
workloads with extensive use of heavy instructions sets such as Intel® Advanced
Vector Extensions 512 (Intel® AVX-512), may assert thermal and/or performance
faults with an associated event recorded in the System Event Log (SEL).
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 29
CONFIGURING the SERVER (User Selectable)
Supported Configurations
■ Choose two identical CPUs from any one of the rows of Table 5 Available CPUs, page 29
■ You must select two identical CPUs listed in Table 5 Available CPUs, page 29.
■ Dual socket is required with All NVMe server
30 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
CONFIGURING the SERVER (User Selectable)
Select DIMMs
Ranks
Product ID (PID) PID Description Voltage
/DIMM
HXE-MR-X64G2RW Cisco HX Express 64GB RDIMM DRx4 3200 (16Gb) 1.2 V 2
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 31
CONFIGURING the SERVER (User Selectable)
Drive
Product ID (PID) PID Description Capacity
Type
Front Capacity Drive
HXE-NVMEI4-I3840 Cisco HX Express 3.8TB 2.5in U.2 Intel P5500 NVMe HPer MEnd NVMe 3.8 TB
HXE-NVMEI4-I7680 Cisco HX Express 7.6TB 2.5in U.2 Intel P5500 NVMe HPer MEnd NVMe 7.6 TB
HXE-NVMEM6-W15300 15.3TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance NVMe 15.3 TB
HXE-NVME4-3840 Cisco HX Express 3.8TB2.5inU.2 P5520NVMeHighPerf Med Endur NVMe 3.8 TB
HXE-NVME4-7680 Cisco HX Express 7.6TB2.5in U.2 P5520NVMe HighPerf Med Endur NVMe 7.6 TB
HXE-NVMEM6-W15300 Cisco HX Express 15.3TB 2.5in U.2WD SN840NVMeExtrmPerfValEnd NVMe 15.3 TB
Rear Capacity Drive
HXE-NVMEI4-I3840 Cisco HX Express 3.8TB 2.5in U.2 Intel P5500 NVMe HPer MEnd NVMe 3.8 TB
HXE-NVMEI4-I7680 Cisco HX Express 7.6TB 2.5in U.2 Intel P5500 NVMe HPer MEnd NVMe 7.6 TB
HXE-NVMEM6-W15300 15.3TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance NVMe 15.3 TB
HXE-NVME4-3840 Cisco HX Express 3.8TB2.5inU.2 P5520NVMeHighPerf Med Endur NVMe 3.8 TB
HXE-NVME4-7680 Cisco HX Express 7.6TB2.5in U.2 P5520NVMe HighPerf Med Endur NVMe 7.6 TB
HXE-NVMEM6-W15300 Cisco HX Express 15.3TB 2.5in U.2WD SN840NVMeExtrmPerfValEnd NVMe 15.3 TB
Approved Configurations
■ Capacity drive:
— Six to twenty-four (twenty-two front + two rear) capacity drives
32 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
CONFIGURING the SERVER (User Selectable)
Drive
Product ID (PID) PID Description Capacity
Type
Front Capacity Drive
HXE-SD38T61X-EV Cisco HX Express 3.8TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
HXE-SD76T61X-EV Cisco HX Express 7.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 7.6 TB
HXE-SD38T6S1X-EV Cisco HX Express 3.8TB 2.5inch Enterprise Value 6G SATA SSD SATA 3.8 TB
HXE-SD76T6S1X-EV Cisco HX Express 7.6TB 2.5inch Enterprise Value 6G SATA SSD SATA 7.6 TB
Rear Capacity Drive
HXE-SD38T61X-EV Cisco HX Express 3.8TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
HXE-SD76T61X-EV Cisco HX Express 7.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 7.6 TB
HXE-SD38T6S1X-EV Cisco HX Express 3.8TB 2.5inch Enterprise Value 6G SATA SSD SATA 3.8 TB
HXE-SD76T6S1X-EV Cisco HX Express 7.6TB 2.5inch Enterprise Value 6G SATA SSD SATA 7.6 TB
NOTE: Cisco uses solid state drives (SSDs) from a number of vendors. All solid state drives (SSDs) are subject
to physical write limits and have varying maximum usage limitation specifications set by the manufacturer.
Cisco will not replace any solid state drives (SSDs) that have exceeded any maximum usage specifications set
by Cisco or the manufacturer, as determined solely by Cisco.
Approved Configurations
Capacity drive:
NOTE:
■ Rear drives can only be selected once after the front drive slots are filled.
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 33
CONFIGURING the SERVER (User Selectable)
Drive
Product ID (PID) PID Description Capacity
Type
Front Capacity Drive
HXE-HD24TB10K4KN Cisco HX Express 2.4 TB 12G SAS 10K RPM SFF HDD (4K) SAS 2.4 TB
Rear Capacity Drive
HXE-HD24TB10K4KN Cisco HX Express 2.4 TB 12G SAS 10K RPM SFF HDD (4K) SAS 2.4 TB
NOTE: Cisco uses solid state drives (SSDs) from a number of vendors. All solid state drives (SSDs) are subject
to physical write limits and have varying maximum usage limitation specifications set by the manufacturer.
Cisco will not replace any solid state drives (SSDs) that have exceeded any maximum usage specifications set
by Cisco or the manufacturer, as determined solely by Cisco.
Approved Configurations
Capacity drive:
NOTE:
■ Rear drives can only be selected once after the front drive slots are filled
34 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
CONFIGURING the SERVER (User Selectable)
http://ucspowercalc.cisco.com
Notes:
1. The 2300 W power supply uses a different power connector that the rest of the power supplies, so you must
use different power cables to connect it. See Table 11 on page 36 and Table 12 on page 39.
NOTE: In a server with two power supplies, both power supplies must be identical.
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 35
CONFIGURING the SERVER (User Selectable)
NOTE: Table 11 lists the power cords for servers that use power supplies less than
2300 W. Table 12 lists the power cords for servers that use 2300 W power supplies.
Note that the power cords for 2300 W power supplies use a C19 connector so they
only fit the 2300 W power supply connector.
Table 11 Available Power Cords (for server PSUs less than 2300 W)
Connector:
IEC60320/C13
186570
CAB-AC-L620-C13 AC Power Cord, NEMA L6-20 - C13,
2M/6.5ft
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 36
CONFIGURING the SERVER (User Selectable)
Table 11 Available Power Cords (for server PSUs less than 2300 W)
186571
CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug,
Australia
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
Plug: EL 701C
EL 210 (EN 60320/C15)
186580
(BS 1363A) 13 AMP fuse
186576
CAB-250V-10A-ID Power Cord, 250V, 10A, India
OVE
Connector:
EL 701
187490
Connector:
Plug: EL 701B
EL 212 (IEC60320/C13)
186574
(SI-32)
37 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
CONFIGURING the SERVER (User Selectable)
Table 11 Available Power Cords (for server PSUs less than 2300 W)
186575
CAB-9K10A-SW Power Cord, 250VAC 10A MP232
Plug, Switzerland
Cordset rating: 10 A, 250 V
Plug: Length: 8 ft. 2 in (2.5 m)
MP232-R
Connector:
IEC 60320 C15
186578
CAB-9K10A-UK Power Cord, 250VAC 10A BS1363
Plug (13 A fuse), UK
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
Plug: EL 701C
EL 210 (EN 60320/C15)
186580
(BS 1363A) 13 AMP fuse
2,133.6 ± 25
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 38
CONFIGURING the SERVER (User Selectable)
39 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
CONFIGURING the SERVER (User Selectable)
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 40
CONFIGURING the SERVER (User Selectable)
41 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
CONFIGURING the SERVER (User Selectable)
If you have noncritical implementations and choose to have no service contract, the following
coverage is supplied:
For support of the entire HyperFlex System, Cisco offers the Cisco Smart Net Total Care Service.
This service provides expert software and hardware support to help sustain performance and
high availability of the unified computing environment. Access to Cisco Technical Assistance
Center (TAC) is provided around the clock, from anywhere in the world.
For systems that include Unified Computing System Manager, the support service includes
downloads of UCSM upgrades. The Cisco Smart Net Total Care Service includes flexible hardware
replacement options, including replacement in as little as two hours. There is also access to
Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of
the unified computing environment. For more information please refer to the following url:
http://www.cisco.com/c/en/us/services/technical/smart-net-total-care.html?stickynav=1
Note: For PID HXAF240C-M6SN-EXP, select Service SKU with HXANF240 suffix (Exmple: CON-OSP-HXANF240)
For PID HXAF240C-M6SX-EXP, select Service SKU with HXAF2C40 suffix (Example: CON-OSP-HXAF2C40)
Solution Support includes both Cisco product support and solution-level support, resolving
complex issues in multivendor environments, on average, 43% more quickly than product
support alone. Solution Support is a critical element in data center administration, to help
rapidly resolve any issue encountered, while maintaining performance, reliability, and return on
investment.
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 42
CONFIGURING the SERVER (User Selectable)
This service centralizes support across your multivendor Cisco environment for both our
products and solution partner products you’ve deployed in your ecosystem. Whether there is an
issue with a Cisco or solution partner product, just call us. Our experts are the primary point of
contact and own the case from first call to resolution. For more information please refer to the
following url:
http://www.cisco.com/c/en/us/services/technical/solution-support.html?stickynav=1
Note: For PID HXAF240C-M6SN-EXP, select Service SKU with HXANF240 suffix (Exmple: CON-SSC4P-HXANF240)
For PID HXAF240C-M6SX-EXP, select Service SKU with HXAF2C40 suffix (Example: CON-SSC4P-HXAF2C40)
Success Tracks builds on the Smart Net Total Care and Solution Support offers as described above
and provides access to the CX Cloud, a centralized, web-based portal which is a personalized
connection to Cisco for accessing support, knowledge, insights, and recommendations from
Cisco experts to maximize the value of Cisco assets. CX Cloud connects you with Cisco's global
user base to share your expertise, exchange ideas, and discuss best practices.
With Level 1 Support Cisco provides resources that support running and maintaining Products.
You will have access to “Ask the Experts” knowledge sessions. These sessions are led by solution
specialists who teach best practices for operating Products. Access to CX Centers will be
available 24x7 to help resolve Product issues with Solution Support; this access streamlines case
management for solutions comprised of Cisco and Solution Support Alliance Partner products. In
addition, you will have access to case information, up-to-date install base views, and e-learning
courses.
Note: For PID HXAF240C-M6SX, select Service SKU with HXAF24CX suffix (Example: CON-L14OS-HXAF24CX)
For PID HX240C-M6SX, select Service SKU with HX240CMX suffix (Example: CON-L14OS-HX240CMX)
43 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
SUPPLEMENTAL MATERIAL
SUPPLEMENTAL MATERIAL
Chassis
An internal view of the HX240C M6 All NVMe/All Flash/Hybrid Server Nodes chassis with the top
cover removed is shown in Figure 8.
Figure 8 HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes With Top Cover Off
1 2 3 4
309022
1 Front-loading drive bays 2 Cooling fan modules (six, hot-swappable)
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 44
SUPPLEMENTAL MATERIAL
5 PCIe riser 3 (PCIe slots 7 and 8 numbered from 6 PCIe riser 2 (PCIe slots 4, 5, 6 numbered
bottom to top), with the following options: from bottom to top), with the following
options:
■ 3A (Default Option)—Slots 7 (x24
mechanical, x8 electrical), and 8 (x24 ■ 2A (Default Option)—Slot 4 (x24
mechanical, x8 electrical). Both slots can mechanical, x8 electrical) supports
accept a full height, full length GPU card. full height, ¾ length card; Slot 5 (x24
mechanical, x16 electrical) supports
■ 3B (Storage Option)—Slots 7 (x24
full height, full length GPU card; Slot
mechanical, x4 electrical) and 8 (x24
6 (x24 mechanical, x8 electrical)
mechanical, x4 electrical). Both slots can
supports full height, full length card.
accept 2.5-inch SFF universal HDDs.
■ 3C (GPU Option)—Slots 7 (x24 mechanical,
x16 electrical) and 8 empty (NCSI support
limited to one slot at a time). Slot 7 can
support a full height, full length,
double-wide GPU card.
45 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
SUPPLEMENTAL MATERIAL
Risers
Figure 9 shows the locations of the PCIe riser connectors on the HX240C M6 All NVMe/All
Flash/Hybrid Server Nodes motherboard.
Figure 9 HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes Riser Connector
Locations
Riser 3 Connector
(controlled from CPU2)
Riser 2 Connectors
(Riser 2 controlled from CPU2)
Riser 1 Connectors
(Riser 1 controlled from CPU1)
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 46
SUPPLEMENTAL MATERIAL
Figure 10 shows the locations of the PCIe riser connectors on the HX240C M6 All NVMe/All
Flash/Hybrid Server Nodes motherboard.
Figure 10 HX240C M6 All NVMe/All Flash/Hybrid Server Nodes Riser Connector Locations
Riser 3 Connector
FullHeight Riser 3
Riser 2 Connectors
FullHeight Riser 2
FullHeight Riser 1
Riser 1 Connectors
47 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
SUPPLEMENTAL MATERIAL
Riser 1A
Riser 1A mechanical information is shown in Figure 12.
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 48
SUPPLEMENTAL MATERIAL
Riser 1B
Riser 1B mechanical information is shown in Figure 13.
Edge connectors
49 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
SUPPLEMENTAL MATERIAL
Riser 2A
Riser 2A mechanical information is shown in Figure 14.
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 50
SUPPLEMENTAL MATERIAL
Riser 3A
Riser 3A mechanical information is shown in Figure 15.
51 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
SUPPLEMENTAL MATERIAL
Riser 3B
Riser 3B mechanical information is shown in Figure 16.
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 52
SUPPLEMENTAL MATERIAL
Riser 3C
Riser 3C mechanical information is shown in Figure 17.
53 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
SPARE PARTS
SPARE PARTS
This section lists the upgrade and service-related parts for the HyperFlex Express HX240C M6 All NVMe/All
Flash/Hybrid Server Nodes. Some of these parts are configured with every server.
NOTE: Some spare parts you order may also require accessories for full
functionality. For example, drives or RAID controllers may need accompanying
cables. CPUs may need heatsinks, thermal paste, and installation tools. The spares
and their accessory parts are listed in Table 19.
KVM Cable
Risers
CPUs
Note: If you are ordering a second CPU, see the CPU Accessories section in this table for additional
parts you may need to order for the second CPU.
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 54
SPARE PARTS
CPU Accessories
UCS-CPU-TIM= Single CPU thermal interface material syringe for M5 server HS seal1
Memory
3200-MHz DIMMs
DIMM Blank
Drives
Note: When ordering additional SAS/SATA or NVMe front or rear drives, you may need to order a cable to
connect from the drive to the motherboard. See the Drive Cables section in this table.
HX-NVMEI4-I1920= 1.9TB 2.5in U.2 Intel P5500 NVMe High Perf Medium Endurance
HX-NVMEI4-I3840= 3.8TB 2.5in U.2 Intel P5500 NVMe High Perf Medium Endurance
HX-NVMEI4-I7680= 7.6TB 2.5in U.2 Intel P5500 NVMe High Perf Medium Endurance
HX-NVMEM6-W15300= 15.3TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance
55 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
SPARE PARTS
HX-NVMEI4-I1920= 1.9TB 2.5in U.2 Intel P5500 NVMe High Perf Medium Endurance
HX-NVMEI4-I3840= 3.8TB 2.5in U.2 Intel P5500 NVMe High Perf Medium Endurance
HX-NVMEI4-I7680= 7.6TB 2.5in U.2 Intel P5500 NVMe High Perf Medium Endurance
HX-NVMEM6-W15300= 15.3TB 2.5in U.2 WD SN840 NVMe Extreme Perf. Value Endurance
HX-NVME2H-I1000= Cisco 2.5" U.2 1,0 TB Intel P4510 NVMe High Perf. Value Endurance
Boot Drive
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 56
SPARE PARTS
HX-NVMEM6-W1600 1.6TB 2.5in U.2 WD SN840 NVMe Extreme Perf. High Endurance
Boot Drive
HX240C-M6SX-EXP (Hybrid)
Boot Drive
57 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
SPARE PARTS
Extender Board
Cables
HX-SAS-240M6= Cisco 12G SAS HBA (for UCSC-C240-M6S and UCSC-C240-M6SX servers)
UCS-M2-HWRAID= Cisco Boot optimized M.2 RAID controller (holds up to two M.2 SATA
SSDs)
PCI cards
HX-M-V25-04= Cisco UCS VIC 1467 quad port 10/25G SFP28 mLOM
HX-M-V100-04= Cisco UCS VIC 1477 dual port 40/100G QSFP28 mLOM
HX-PCIE-C100-04= Cisco UCS VIC 1495 dual port 40/100G QSFP28 CNA PCIe
HX-PCIE-C25Q-04= Cisco UCS VIC 1455 quad port 10/25G SFP28 PCIe
1 Gb NICs
10 Gb NICs
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 58
SPARE PARTS
25 Gb NICs
Note: If you are adding a GPU, you may need to add cables for the GPU. See the GPU Cables section of
this table.
CBL-GPU-C240M6= Y TYPE GPU POWER Cable for A10 GPU, C240M6 and C245M6
Power Supplies
Power Cables
CAB-48DC-40A-8AWG= C-Series -48VDC PSU Power Cord, 3.5M, 3 Wire, 8AWG, 40A
59 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
SPARE PARTS
CAB-9K12A-NA4= Power Cord, 125VAC 13A NEMA 5-15 Plug, North America
CAB-48DC-40A-AS= C-Series -48VDC PSU PWR Cord, 3.5M, 3Wire, 8AWG, 40A (AS/NZ
CAB-48DC-40A-INT= C-Series -48VDC PSU PWR Cord, 3.5M, 3 Wire, 8AWG, 40A (INT)
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 60
SPARE PARTS
Rail Kit
HX-RAIL-M6= Ball Bearing Rail Kit for C220 & C240 M6 rack servers
CMA
Security
Bezel
HX-VSP-EPL-1A= VMware vSphere 7.x Ent Plus (1 CPU, 32 core), 1-yr, Support Required
HX-VSP-EPL-3A= VMware vSphere 7.x Ent Plus (1 CPU, 32 core), 3-yr, Support Required
HX-VSP-EPL-5A= VMware vSphere 7.x Ent Plus (1 CPU, 32 core), 5-yr, Support Required
HX-VSP-STD-1A= VMware vSphere 7.x Standard (1 CPU, 32 core), 1-yr, Support Required
HX-VSP-STD-3A= VMware vSphere 7.x Standard (1 CPU, 32 core), 3-yr, Support Required
HX-VSP-STD-5A= VMware vSphere 7.x Standard (1 CPU, 32 core), 5-yr, Support Required
Operating system
MSWS-19-DC16C-NS= Windows Server 2019 Data Center (16 Cores/Unlimited VMs) - No Cisco
SVC
MSWS-19-ST16C-NS= Windows Server 2019 Standard (16 Cores/2 VMs) - No Cisco SVC
Notes:
1. This part is included with the purchase of option or spare CPU or CPU processor kits.
61 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
SPARE PARTS
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 62
UPGRADING or REPLACING CPUs
(1) Have the following tools and materials available for the procedure:
(2) Order the appropriate replacement CPU from Table 5 on page 29:
Carefully remove and replace the CPU and heatsink in accordance with the instructions found in
“M5 server Installation and Service Guide” found at:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C240M5/install/C240M
5/C240M5_chapter_010.html?bookSearch=true#concept_bfk_kwp_hz
(1) Have the following tools and materials available for the procedure:
(3) Order one heat sink for each new CPU. Order PID UCSC-HSHP-240M6= for servers with no
GPU. Order PID UCSC-HSLP-M6= for servers with GPUs.
Carefully install the CPU and heatsink in accordance with the instructions found in “M5 server
Installation and Service Guide,” found at:
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 63
UPGRADING or REPLACING MEMORY
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C240M5/install/C240M
5/C240M5_chapter_010.html?bookSearch=true#concept_bfk_kwp_hz
Step 2 Press evenly on both ends of the DIMM until it clicks into place in its slot
Note: Ensure that the notch in the DIMM aligns with the slot. If the notch is misaligned, it is
possible to damage the DIMM, the slot, or both.
Step 3 Press the DIMM connector latches inward slightly to seat them fully.
Step 4 Populate all slots with a DIMM or DIMM blank. A slot cannot be empty.
1
3
2
4
1
306040
For additional details on replacing or upgrading DIMMs, see “Cisco M5 Server Installation and
Service Guide” found at this link:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C240M5/install/C240M
5/C240M5_chapter_010.html?bookSearch=true#concept_c53_tbp_hz
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 64
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Dimensions and Weight
Table 20 HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes Dimensions and Weight
Parameter Value
Height 3.42 in. (8.7 cm)
Width (including slam latches) 16.9 in.(42.9 cm)
Depth 30 in. (76.2 cm)
Front Clearance 3 in. (76 mm)
Side Clearance 1 in. (25 mm)
Rear Clearance 6 in. (152 mm)
Weight
Weight with following options and no rail kit: 35.7 lbs (16.2 kg)
0 HDD, 0 CPU, 0 DIMM, and 1 2300 W power supply
Weight with following options and including rail kit: 44 lbs (20 kg)
0 HDD, 0 CPU, 0 DIMM, and 1 2300 W power supply
Weight with following options and no rail kit: 37.6 lbs (17 kg)
1 HDD, 1 CPU, 1 DIMM, and 1 2300 W power supply
Weight with following options and including rail kit: 45.9 lbs (20.8 kg)
1 HDD, 1 CPU, 1 DIMM, and 1 2300 W power supply
Weight with following options and no rail kit: 44.71 lbs (20.28 kg)
8 HDDs, 2 CPUs, 32 DIMMs, and 2 2300 W power supplies
Weight with following options and including rail kit: 49.2 lbs (22.32 kg)
8 HDDs, 2 CPUs, 32 DIMMs, and 2 2300 W power supplies
Weight with following options and no rail kit: 33.14 lbs (15 kg)
0 HDD, 0 CPU, 0 DIMM, and 1 2300 W power supply
Weight with following options and including rail kit: 41.45 lbs (18.8 kg)
0 HDD, 0 CPU, 0 DIMM, and 1 2300 W power supply
Weight with following options and no rail kit: 40.55 lbs (18.4kg)
1 HDD, 1 CPU, 1 DIMM, and 1 2300 W power supply
Weight with following options and including rail kit: 48.86 lbs (22.2 kg)
1 HDD, 1 CPU, 1 DIMM, and 1 2300 W power supply
Weight with following options and no rail kit: 58.8 lbs (26.7 kg)
24 HDDs, 2 CPUs, 32 DIMMs, and 2 2300 W power supplies
Weight with following options and including rail kit: 61.7 lbs (28 kg)
24 HDDs, 2 CPUs, 32 DIMMs, and 2 2300 W power supplies
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 65
TECHNICAL SPECIFICATIONS
Power Specifications
The server is available with the following types of power supplies:
Table 21 HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes Power Specifications
(1050 W AC power supply)
Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (V rms) 100 to 240
Maximum Allowable Input Voltage Range (V rms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W)1 800 1050
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (V rms) 100 120 208 230
Nominal Input Current (A rms) 9.2 7.6 5.8 5.2
Maximum Input at Nominal Input Voltage (W) 889 889 1167 1154
Maximum Input at Nominal Input Voltage (VA) 916 916 1203 1190
Minimum Rated Efficiency (%)2 90 90 90 91
Minimum Rated Power Factor2 0.97 0.97 0.97 0.97
Maximum Inrush Current (A peak) 15
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)3 12
Notes:
1. Maximum rated output is limited to 800W when operating at low-line input voltage (100-127V)
2. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
3. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 66
TECHNICAL SPECIFICATIONS
Table 22 HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes Power Specifications
(1050 W V2 DC power supply)
Parameter Specification
Input Connector Molex 42820
Input Voltage Range (V rms) -48
Maximum Allowable Input Voltage Range (V rms) -40 to -72
Frequency Range (Hz) NA
Maximum Allowable Frequency Range (Hz) NA
Maximum Rated Output (W) 1050
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (V rms) -48
Nominal Input Current (A rms) 24
Maximum Input at Nominal Input Voltage (W) 1154
Maximum Input at Nominal Input Voltage (VA) 1154
Minimum Rated Efficiency (%)1 91
Minimum Rated Power Factor1 NA
Maximum Inrush Current (A peak) 15
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)2 5
Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
67 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
TECHNICAL SPECIFICATIONS
Table 23 HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes 1600 W (AC) Power
Supply Specifications
Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (V rms) 200 to 240
Maximum Allowable Input Voltage Range (V rms) 180 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W)1 1600
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (V rms) 100 120 208 230
Nominal Input Current (A rms) NA NA 8.8 7.9
Maximum Input at Nominal Input Voltage (W) NA NA 1778 1758
Maximum Input at Nominal Input Voltage (VA) NA NA 1833 1813
Minimum Rated Efficiency (%)2 NA NA 90 91
Minimum Rated Power Factor2 NA NA 0.97 0.97
Maximum Inrush Current (A peak) 30
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)3 12
Notes:
1. Maximum rated output is limited to 800W when operating at low-line input voltage (100-127V)
2. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
3. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 68
TECHNICAL SPECIFICATIONS
Table 24 HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes 2300 W (AC) Power
Supply Specifications
Parameter Specification
Input Connector IEC320 C20
Input Voltage Range (Vrms) 100 to 240
Maximum Allowable Input Voltage Range (Vrms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W)1 2300
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (Vrms) 100 120 208 230
Nominal Input Current (Arms) 13 11 12 10.8
Maximum Input at Nominal Input Voltage (W) 1338 1330 2490 2480
Maximum Input at Nominal Input Voltage (VA) 1351 1343 2515 2505
Minimum Rated Efficiency (%)2 92 92 93 93
Minimum Rated Power Factor2 0.99 0.99 0.97 0.97
Maximum Inrush Current (A peak) 30
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)3 12
Notes:
1. Maximum rated output is limited to 1200W when operating at low-line input voltage (100-127V)
2. This is the minimum rating required to achieve 80 PLUS Titanium certification, see test reports published at
http://www.80plus.org/ for certified values
3. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
http://ucspowercalc.cisco.com
69 Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes
TECHNICAL SPECIFICATIONS
Environmental Specifications
The environmental specifications for the HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server
Nodes are listed in Table 25.
Table 25 Cisco HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes Environmental
Specifications
Parameter Minimum
Operating Temperature Dry bulb temperature of 10°C to 35°C (50°F to 95°F)
Maximum temperature change of 20°C (36°F) per hour
(a temperature change within a specified period of time and not
a rate of change)
Humidity condition: Uncontrolled, not to exceed 50% RH starting
condition
Derate the maximum temperature by 1°C (33.8°F) per every 305
meters of altitude above 900m
Extended Operating Temperature 5°C to 40°C (41°F to 104°F) with no direct sunlight
Humidity condition: Uncontrolled, not to exceed 50% RH starting
condition
Derate the maximum temperature by 1°C (33.8°F) per every 305
meters of altitude above 900m
Non-Operating Temperature Dry bulb temperature of -40°C to 65°C (-40°F to 149°F)
Operating Relative Humidity 10% to 90% and 28°C (82.4°F) maximum dew-point temperature,
non-condensing environment
Minimum to be higher (more moisture) of -12°C (10.4°F) dew
point or 8% relative humidity
Maximum to be 24°C (75.2°F) dew point or 90% relative humidity
Non-Operating Relative Humidity 5% to 93% relative humidity, non-condensing, with a maximum
wet bulb temperature of 28°C across the 20°C to 40°C dry bulb
range.
Maximum Operating Duration Unlimited
Operating Altitude A maximum elevation of 3050 meters (10,006 ft)
Non-Operating Altitude An elevation of 0 to 12,000 meters (39,370 ft)
Sound Power level, Measure 5.5
A-weighted per ISO7779 LWAd (Bels)
Operation at 23°C (73°F)
Sound Pressure level, Measure 40
A-weighted per ISO7779 LpAm (dBA)
Operation at 23°C (73°F)
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 70
TECHNICAL SPECIFICATIONS
Table 26 HyperFlex Express HX240C M6 All NVMe/All Flash/Hybrid Server Nodes Extended Operating
Temperature Hardware Configuration Limits
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 71
TECHNICAL SPECIFICATIONS
Compliance Requirements
The regulatory compliance requirements for HX-Series servers are listed inTable 27
Parameter Description
Cisco HyperFlex Express HX240C M6 All NVMe, All Flash and Hybrid Server Nodes 72