ABB MEASUREMENT & ANALY TICS | DATA SHEET
LST200
Ultrasonic level transmitter
2 LST200 ULT R AS ON I C LEVEL T R ANSMIT TE R | DS/LST200-E N RE V. A L ST20 0 ULTR A SONIC LE V E L TR A NSMIT TE R | D S/LST2 00- E N RE V. A 3
— —
Overview
Measurement made easy Level measurement is a key requirement in many industries
where accurate data on liquid levels is needed for purposes
The easy choice for intelligent level ranging from managing storage through to reporting. In
water and wastewater treatment applications, where dozens
measurement of level devices may be used, a product that offers simple
commissioning, reliable operation, fast delivery and easy
maintenance offers tremendous customer value.
Developed in conjunction with our customers and drawing on
ABB's extensive experience in level measurement, the LST200
ultrasonic level transmitter offers a simple, smart and reliable
level measurement solution. Featuring a modular design, the
Easy to use LST200 utilizes the latest developments in digital sensing
• Easy setup menu and clear backlight for easy configuration technology, including built-in smart chip and an interface for
upgrading with future modern data acquisition methods such Basic
• Easy installation, maintenance and upgrade with modular design as NB-IoT, offering the full benefits of digitalization for
improved measurement and sharing of data. LCD
Smart and reliable
• Compact transmitter with real-time echo waveform display and
diagnostic messages
• Reliable accuracy with temperature compensation (better than ±3 mm
or 0.25% of full span)
• Reliable and smart algorithm with noise filtering for challenging
applications
• Reliable protection grade IP66/IP68 which is typical for water and
wastewater industry
• Reliable electromagnetic compatibility (IEC CISPR standard) proved by
independent laboratory testing
4 LST200 ULT R AS ON I C LEVEL T R ANSMIT TE R | DS/LST200-E N RE V. A L ST20 0 ULTR A SONIC LE V E L TR A NSMIT TE R | D S/LST2 00- E N RE V. A 5
— —
Typical applications-water & waste water Typical LST200 connection
The LST200 is a two-wire loop-powered device that can be connected directly with a DCS or PLC. Setup can be performed ei-
ther through the LCD display or on a PC or laptop.
Chemical storage Lagoons & settling ponds
• L
ST200’s enclosure is made from polycarbonate • B
acklit display with easy setup menu helps
which is resistant to mild acid and base, chloride, oxidizer. to simplify outdoor installation and
commissioning.
B
ABB FIM Tool
D
FDI Package
A 4~20mA
A DCS or PLC
B Computer with configuration software (through ABB FIM tool with FDI package)
C Interface cable (specially designed for LST200, see order code in page 9)
D LCD
E LST200
—
Terminal connections
Wet wells, lift stations and pumping • Positive polarity of power supply (+)
stations • Negative polarity of power supply (–)
Open channel • Grounding for the shield layer of
• Immune to noise caused by the presence of heavy
• Built-in equations and supporting power supply (GND, Optional)
equipment like variable speed drives, LST200 is the
software for open channel flow save
perfect choice in pumping stations.
you from doing the math manually.
• IP68-rated submersible design provides protection
against flooding.
Interface cable and LCD port
Power supply terminal
Process basins including aeration, chlorine
contact, skimmer tanks, sedimentation and
flotation thickeners
• With advanced diagnostic functions such as detailed signal
q
uality tracking and noise level diagnostics, the LST200
provides an easy to install alternative to remote instruments.
• Works easily in the presence of turbulence and foam using
unique GAP (Gain, Amplitude, and Power) technology.
6 LST200 ULT R AS ON I C LEVEL T R ANSMIT TE R | DS/LST200-E N RE V. A L ST20 0 ULTR A SONIC LE V E L TR A NSMIT TE R | D S/LST2 00- E N RE V. A 7
— Key parameters
Dimensions Should be set ≥ 350 mm, signals
B Blanking area
within this area would be ignored
90.3 mm 81 mm
(3.6 in) (3.2 in) D Distance Distance from sensor surface
Max. 8 m, set according to the
α E Empty distance distance from tank bottom to
B sensor
(S) Level from tank bottom
119.4 mm
(4.7 in)
L Level
(defined by empty distance) sensor
D
Set according to users’ 100% out-
80 mm put point, suggest leave a safety
F Full range (Span)
209.4 mm
(3.1 in)
(8.2 in)
distance “S” from blanking area
E
F r Detection range reference, avoid
obstructions (Filling water,
(1.4 in)
35 mm
switches, weld seam) in this range.
Reference for best perfor-
80 mm L α Emitting angle 10° mance:distance from tank bottom
(3.5 in)
90 mm
to sensor
D=8 m, r=694 mm D=6 m, r=519 mm
M56 × 3.0, length 35 mm D=5 m, r=431 mm D=4 m, r=344 mm
D=2 m, r=169 mm D= 1 m, r=81 mm
— Nozzle installation
For easier installation or keeping a safety distance ‘S’ between the blanking area and upper range limits (URV), you may need
Direct installation the help of a pipe nozzle to install the instrument at a certain height. The interior of the nozzle must be smooth without burrs
or joints and a 45-degree angle edge would be ideal to minimize the disturbance. The limits of the nozzle are as below:
Nozzle dimension Max. length
(Dn) (Ln mm)
Ln
Using the thread Using the nut
DN80 /3" 180
Dn
DN100 /4" 225
— DN150 /6" 345
45°
Open channel or basin mounting DN200 /8" 450
DN250 /10" 800
DN300 /12" 1500
Floor mounting Wall mounting
8 LST200 ULT R AS ON I C LEVEL T R ANSMIT TE R | DS/LST200-E N RE V. A L ST20 0 ULTR A SONIC LE V E L TR A NSMIT TE R | D S/LST2 00- E N RE V. A 9
Technical specifications —
Main Menu
Measurement Language Ordering information
Measurement range Operation Mode
0.35 to 8.00 m (13.78 to 314.96 in) Unit Typical option example: LST200.Y0.S08.M2.P3.L1.A4.CE.LB.M5
Empty Distance LST200 ultrasonic level transmitter LST200· XX XXX XX XX XX XXX XX XX XX
Note:
Operating conditions could attenuate the ultrasound, which
Span Explosion protection certification
may shorten the measurement range. Consult with ABB for Blanking General purpose Y0
Sensor type and range
applications involving bulk material, heavy vapor or dust,
8m S08
strong turbulence or foam.
Mechanical data Process connection type
Beam angle Housing and sensor enclosure: PC M56 x 3.0, Length 35 mm M2
(@ -3 dB, full angle) : 10° (Polycarbonate) Enclosure material/cable entry
Note: The chemical compatibility of the sensors must Polycarbonate/ M20 x 1.5 threaded bore for cable gland P3
Accuracy and repeatability be checked before installation. Power supply
±3 mm or 0.25% of full span, whichever is larger. Loop powered L1
Dimensions Output
Note:
90 × 81 × 209 mm (3.56 × 3.19 × 8.24 in) 4 to 20 mA analog A4
Accuracy and stability are further ensured by algorithm in-
cluding temperature compensation, GAP regulator and noise Certificate
Weight
filter. Calibration report CE
680 g
HMI
Resolution No LCD with blind cover L0
Cable entry LCD with backlight LB
1 mm
M20 × 1.5 threaded bore for cable gland, directly on housing
Language
Update time English M5
Process connection: Chinese M6
2s
M56X3.0, length 35 mm
Electrical data
Terminals Environmental data
—
Max. cable cross section: 1.5 mm (AWG 16)
2
Electromagnetic compatibility (EMC) Accessories and spare parts
· IEC 61326-1 Table 2
Power supply · CISPR Class B
Ordering code Description
LST200-Basic: 15 to 30 VDC.
3KXL065041U0100 Small L-shape bracket assembly,wall mounted(350 mm)
LST200-LCD: 19 to 30 VDC. Protect IP
Ripple: Maximum 5% IP66/67 according to EN 60529 3KXL065041U0200 Extendable bracket assembly,wall mounted(547~732 mm)
IP68-rated up to 2 meters for 24 hours at room temperature 3KXL065041U0400 Small L-shape bracket assembly,floor mounted(350 mm)
Power consumption 3KXL065048U0300 Extendable bracket assembly,floor mounted(547~732 mm)
60 mW to 600 mW Temperature 3KXL065057U0100 Anti-water pad for heavy condensation application
-30 to 60 °C (-22 to 140 °F) according to EN 60068-2-14
3KXL065113U0100 Interface cable for configuring LST200 with computer
Analog output -20 to 60 °C (-4 to 140 °F) for display
3KXL065068U1800 LCD (For configuring LST200 if you choose No LCD option or as spare part)
Two-wire output: 4 to 20 mA related to
level/distance/volume/flow, full Humidity
compensation for temperature effects Relative humidity: up to 100%
Integrated LCD display (Optional) Sensor pressure
Blue backlight, 6 mm height display with percentage bargraph Measurement range from -4 to 44 psi
Simplified two-button programming with easy set up menu (-0.25 to 3.0 bar)
enables fast configuration
Real-time waveform Vibration resistance
Diagnostics messages Random: according to EN 60068-2-64
Totalized and actual flow indication Shock: IEC 60068-2-27
Language: English and Chinese
Climate class
IEC 60068-2-38 Test Z/AD
10 LST200 ULT R AS ON I C LEVEL T R ANSMIT TE R | DS/LST200-E N RE V. A L ST20 0 ULTR A SONIC LE V E L TR A NSMIT TE R | D S/LST2 00- E N RE V. A 11
Notes
Sales Service
—
ABB Engineering (Shanghai) Ltd.
Measurement & Analytics
No. 4528, Kangxin Highway,
Pudong New District Shanghai,
201319, P.R. China
Tel: +86(0) 21 6105 6666
Fax: +86(0) 21 6105 6677
Mail:
[email protected]abb.com/level
DS/LST200-EN Rev. A 07.2020
We reserve the right to make technical changes or modify the contents of this document without
prior notice. With regard to purchase orders, the agreed particulars shall prevail.
ABB does not accept any responsibility whatsoever for potential errors or possible lack
of information in this document.
We reserve all rights in this document and in the subject matter and illustrations contained
therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole
or in parts – is forbidden without prior written consent of ABB.
© 2020 ABB