DIMENSIONS SETTING
EASYTOUCH
The sensor uses the patent-covered EASYTOUCH
technology that allows a rapid self-setting of the product.
- EASYTOUCH (with reflector):
sensor sets the best sensitivity mode for the detection of
transparent objects.
- EASYTOUCH: (without reflector, default setting):
S40-PH-x-B03 sensor sets the maximum sensitivity level without reflector.
This condition is recommended for opaque object detection.
INSTRUCTION MANUAL EASYTOUCH: (with reflector):
Carefully align the sensor and the
reflector. The light spot has to be
inside the reflector area (see
“Installation” section)
- Press the TEACH-IN push-button until
the OUTPUT LED turns OFF and then
release the push-button.
EASYTOUCH (without reflector)
Before aligning the sensor on reflector (see “Installation”
section), set the sensor without reflector, pressing the
TEACH-IN push-button, await the blinking of the OUTPUT
LED and then release the push-button
FINE DETECTION
Recommended for critical detection conditions such as the
CONTROLS detection of objects with shiny surfaces:
Carefully align the sensor and the reflector. The light spot
OUTPUT LED has to be inside the reflector area (see “Installation”
In the normal operating mode indicates the output status (the
section)
yellow LED ON indicates the output activation). TECHNICAL DATA - Insert object to detect between sensor
In the setting phase indicates the setting steps.
Power supply: 10 … 30 VDC Class 2 UL508 (reverse polarity protection) and reflector.
Please refer to the “SETTING” paragraph for procedure
Ripple: 10% max - Press the TEACH-IN push-button and
indications during detection or setting phases.
await the blinking of the OUTPUT
Consumption 35 mA max.
POWER ON LED LED, without moving the object.
(output current excluded):
The green LED signal indicates the sensor functioning. Release the push-button.
Outputs: NPN or PNP (short-circuit protection) - Remove the object.
The LED blinks with the yellow LED if the detection is lacking. Output current: 100 mA max. - Press the TEACH-IN push-button and
TEACH-IN PUSH-BUTTON Output saturation voltage: 2.4 V max. wait until the blinking OUTPUT LED
A long pressure on the push-button activates the self-setting Response time: 125s max. switch OFF, without moving the
procedure. Switching frequency: 4 kHz object.
The REMOTE input allows the external TEACH-IN control. Release the push-button.
Data retention: EEPROM non volatile memory
Indicators: OUTPUT LED (YELLOW) / POWER ON LED (GREEN) The sensor selects the best operating conditions according to
Setting: TEACH-IN via push-button and wire the acquired points and adjusts itself in the DARK mode
condition. The acquisition sequence has to be inverted to
CONNECTIONS Operating temperature: -20 … +60 °C
select the opposite operating modes.
Storage temperature: -20 … +80 °C
If the OUTPUT LED and the POWER ON LED blink
Electric strength 500 Vac / 1 minimum between electric parts and enclosure contemporarily the detection has failed due to insufficient
Insulation resistance > 20 M / 500 Vdc between electric parts and enclosure contrast or setting procedure error. The procedure has to be
Spot dimension: < 1 mm at a distance of 300 mm repeated from the beginning.
Operating distance (min.values)*: 0.1…6 m on R2 reflector / 0.1…3 m on R7 reflector / 0.1…1.5 m on R8 reflector WARRANTY
Emission type: RED LASER: Class 1 EN 60825-1 (2008) DATALOGIC AUTOMATION warrants its products to be free from
defects.
Classe II CDRH 21 CFR PART 1040.10
DATALOGIC AUTOMATION will repair or replace, free of charge, any
Avarage power 0.080 mW; Pulse = 2.2 s; = 645…660nm; Frequency =20 kHz product found to be defective during the warranty period of 36 months
Ambient light rejection: According to EN 60947-5-2 from the manufacturing date.
Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) This warranty does not cover damage or liability deriving from the
improper application of DATALOGIC AUTOMATION products.
Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27)
DARK/LIGHT selection: automatic with fine detection setting mode DATALOGIC AUTOMATION srl
Housing material: ABS UL 94V-O Via Lavino 265 - 40050 Monte S.Pietro - Bologna – Italy
REMOTE FUNCTION Lens material: Methacrylic PMMA
Tel: +39 051 6765611 - Fax: +39 051 6759324 www.datalogic.com
Mechanical protection: IP67 DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
The connection of the REMOTE wire to + Vdc is equivalent to DATALOGIC AUTOMATION reserves the right to make modifications and
pressing the TEACH-IN push-button. Connections: M8 4-pole connector improvements without prior notification.
Leave the REMOTE wire unconnected and insulated if not Weight: 10 g. max. connector vers. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many
countries, including the U.S.A. and the E.U.
used. If it is connected permanently to 0V, the TEACH-IN
push-button functioning is blocked. *Minimum operating distance refered on the suggested reflector, select the reflector with higher surface area to improve the application tolerance. 8260002832 Rev.D © Copyright Datalogic 2008-2013