DIMENSIONS SETTING
EASYTOUCH
The sensor uses the patent-covered EASY TOUCH
technology that allows a rapid and safe self-setting of the
product.
Two different setting possibilities are available:
- EASYTOUCH: (default programming):
a long pressure of the SET push-button allows self-setting.
- FINE DETECTION:
S40-PH-x-M03 recommended for difficult applications, as for example the
detection of shiny objects.
INSTRUCTION MANUAL Place the target opposite the sensor at the maximum distance
required;
EASYTOUCH (standard detection)
- Press the TEACH-IN push-button until the OUTPUT LED
turns OFF and then release the push-button.
FINE DETECTION
- Press the TEACH-IN push-button and
await the blinking of the OUTPUT
LED, without moving the object.
Release the push-button.
- Remove or further the object.
- Press the TEACH-IN push-button and
wait until the blinking OUTPUT LED
switch OFF, without moving the object.
Release the push-button.
TECHNICAL DATA
The sensor selects the best operating conditions according to
Power supply: 10 … 30 VDC Class 2 UL508 (reverse polarity protection)
the acquired points and adjusts itself in the LIGHT mode
Ripple: 10% max
CONTROLS Consumption
condition. The acquisition sequence has to be inverted to
35 mA max. select the opposite operating modes.
OUTPUT LED (output current excluded): If the OUTPUT LED and the POWER ON LED blink
In the normal operating mode indicates the output status (the Outputs: NPN or PNP (short-circuit protection) contemporarily the detection has failed due to insufficient
yellow LED ON indicates the output activation). Output current: 100 mA max. contrast or setting procedure error. The procedure has to be
In the setting phase indicates the setting steps. Output saturation voltage: 2.4 V max. repeated from the beginning.
Please refer to the “SETTING” paragraph for procedure Response time: 0.5 ms max.
indications during detection or setting phases. Switching frequency: 1 kHz
Data retention: EEPROM non volatile memory REMOTE FUNCTION
POWER ON LED
Indicators: OUTPUT LED (YELLOW) The connection of the REMOTE wire to + Vdc is equivalent to
The green LED signal indicates the sensor functioning.
POWER ON LED (GREEN) pressing the TEACH-IN push-button.
The LED blinks with the yellow LED if the detection is lacking.
Setting: TEACH-IN via push-button and wire Leave the REMOTE wire unconnected and insulated if not
TEACH-IN PUSH-BUTTON Operating temperature: -20 … +60 °C used. If it is connected permanently to 0V, the TEACH-IN
A long pressure on the push-button activates the self-setting Storage temperature: -20 … +80 °C push-button functioning is blocked.
procedure. Electrical protection: Class 2
The REMOTE input allows the external TEACH-IN control.
Spot dimension: < Ø 0.7 mm
Operating distance (min.values)*: 20…60 mm
WARRANTY
Emission type: RED LASER: Class 1 EN 60825-1 (2008) DATALOGIC AUTOMATION warrants its products to be free from
CONNECTIONS Classe II CDRH 21 CFR PART 1040.10 defects.
Avarage power 0.033 mW; Pulse = 3 s; = 645…660nm; Frequency =4.8 kHz DATALOGIC AUTOMATION will repair or replace, free of charge, any
product found to be defective during the warranty period of 36 months
Ambient light rejection: According to EN 60947-5-2
from the manufacturing date.
Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) This warranty does not cover damage or liability deriving from the
Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27) improper application of DATALOGIC AUTOMATION products.
DARK/LIGHT selection: automatic with fine detection setting mode
DATALOGIC AUTOMATION srl
Housing material: ABS UL 94V-O Via Lavino 265 - 40050 Monte S.Pietro - Bologna – Italy
Lens material: Methacrylic PMMA Tel: +39 051 6765611 - Fax: +39 051 6759324 www.datalogic.com
Mechanical protection: IP67 DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
Connections: M8 4-pole connector DATALOGIC AUTOMATION reserves the right to make modifications and
improvements without prior notification.
Weight: 10 g. max. connector vers. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many
countries, including the U.S.A. and the E.U.
*Minimum operating distance refered on the suggested reflector, select the reflector with higher surface area to improve the application tolerance. 8260002852 Rev.D © Copyright Datalogic 2008-2013