S40PH-M03 Miniaturesensors Manual Revd Eng

The document provides instructions for setting and using an Easytouch sensor. It describes the different setting modes, the setting procedure which involves pressing buttons until LEDs turn on/off, and technical specifications for the sensor such as power requirements and output details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views1 page

S40PH-M03 Miniaturesensors Manual Revd Eng

The document provides instructions for setting and using an Easytouch sensor. It describes the different setting modes, the setting procedure which involves pressing buttons until LEDs turn on/off, and technical specifications for the sensor such as power requirements and output details.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

DIMENSIONS SETTING

EASYTOUCH
The sensor uses the patent-covered EASY TOUCH
technology that allows a rapid and safe self-setting of the
product.
Two different setting possibilities are available:
- EASYTOUCH: (default programming):
a long pressure of the SET push-button allows self-setting.
- FINE DETECTION:

S40-PH-x-M03 recommended for difficult applications, as for example the


detection of shiny objects.

INSTRUCTION MANUAL Place the target opposite the sensor at the maximum distance
required;
EASYTOUCH (standard detection)
- Press the TEACH-IN push-button until the OUTPUT LED
turns OFF and then release the push-button.
FINE DETECTION
- Press the TEACH-IN push-button and
await the blinking of the OUTPUT
LED, without moving the object.
Release the push-button.
- Remove or further the object.
- Press the TEACH-IN push-button and
wait until the blinking OUTPUT LED
switch OFF, without moving the object.
Release the push-button.
TECHNICAL DATA
The sensor selects the best operating conditions according to
Power supply: 10 … 30 VDC Class 2 UL508 (reverse polarity protection)
the acquired points and adjusts itself in the LIGHT mode
Ripple: 10% max
CONTROLS Consumption
condition. The acquisition sequence has to be inverted to
35 mA max. select the opposite operating modes.
OUTPUT LED (output current excluded): If the OUTPUT LED and the POWER ON LED blink
In the normal operating mode indicates the output status (the Outputs: NPN or PNP (short-circuit protection) contemporarily the detection has failed due to insufficient
yellow LED ON indicates the output activation). Output current: 100 mA max. contrast or setting procedure error. The procedure has to be
In the setting phase indicates the setting steps. Output saturation voltage: 2.4 V max. repeated from the beginning.
Please refer to the “SETTING” paragraph for procedure Response time: 0.5 ms max.
indications during detection or setting phases. Switching frequency: 1 kHz
Data retention: EEPROM non volatile memory REMOTE FUNCTION
POWER ON LED
Indicators: OUTPUT LED (YELLOW) The connection of the REMOTE wire to + Vdc is equivalent to
The green LED signal indicates the sensor functioning.
POWER ON LED (GREEN) pressing the TEACH-IN push-button.
The LED blinks with the yellow LED if the detection is lacking.
Setting: TEACH-IN via push-button and wire Leave the REMOTE wire unconnected and insulated if not
TEACH-IN PUSH-BUTTON Operating temperature: -20 … +60 °C used. If it is connected permanently to 0V, the TEACH-IN
A long pressure on the push-button activates the self-setting Storage temperature: -20 … +80 °C push-button functioning is blocked.
procedure. Electrical protection: Class 2
The REMOTE input allows the external TEACH-IN control.
Spot dimension: < Ø 0.7 mm
Operating distance (min.values)*: 20…60 mm
WARRANTY
Emission type: RED LASER: Class 1 EN 60825-1 (2008) DATALOGIC AUTOMATION warrants its products to be free from
CONNECTIONS Classe II CDRH 21 CFR PART 1040.10 defects.
Avarage power  0.033 mW; Pulse = 3 s;  = 645…660nm; Frequency =4.8 kHz DATALOGIC AUTOMATION will repair or replace, free of charge, any
product found to be defective during the warranty period of 36 months
Ambient light rejection: According to EN 60947-5-2
from the manufacturing date.
Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) This warranty does not cover damage or liability deriving from the
Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27) improper application of DATALOGIC AUTOMATION products.
DARK/LIGHT selection: automatic with fine detection setting mode
DATALOGIC AUTOMATION srl
Housing material: ABS UL 94V-O Via Lavino 265 - 40050 Monte S.Pietro - Bologna – Italy
Lens material: Methacrylic PMMA Tel: +39 051 6765611 - Fax: +39 051 6759324 www.datalogic.com
Mechanical protection: IP67 DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
Connections: M8 4-pole connector DATALOGIC AUTOMATION reserves the right to make modifications and
improvements without prior notification.
Weight: 10 g. max. connector vers. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many
countries, including the U.S.A. and the E.U.
*Minimum operating distance refered on the suggested reflector, select the reflector with higher surface area to improve the application tolerance. 8260002852 Rev.D © Copyright Datalogic 2008-2013